메뉴 건너뛰기




Volumn 8, Issue 2, 2013, Pages

Whole-Brain CT Perfusion and CT Angiography Assessment of Moyamoya Disease before and after Surgical Revascularization: Preliminary Study with 256-Slice CT

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BRAIN ARTERY BYPASS; BRAIN BLOOD FLOW; BRAIN BLOOD VOLUME; BRAIN PERFUSION; BRAIN RADIOGRAPHY; BRAIN REGION; BRAIN SLICE; CEREBRAL REVASCULARIZATION; CLINICAL ARTICLE; CLINICAL ASSESSMENT; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; FEMALE; GRAFT PATENCY; HEMODYNAMICS; HUMAN; HUMAN TISSUE; IMAGE ANALYSIS; IMAGE DISPLAY; MALE; MIDDLE CEREBRAL ARTERY; MOYAMOYA DISEASE; NEUROIMAGING; POSTOPERATIVE PERIOD; PREOPERATIVE PERIOD;

EID: 84874305360     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0057595     Document Type: Article
Times cited : (53)

References (17)
  • 1
    • 0014477593 scopus 로고
    • Cerebrovascular "moyamoya" disease.Disease showing abnormal net-like vessels in base of brain
    • Suzuki J, Takaku A, (1969) Cerebrovascular "moyamoya" disease.Disease showing abnormal net-like vessels in base of brain. Arch Neurol 20: 288-299.
    • (1969) Arch Neurol , vol.20 , pp. 288-299
    • Suzuki, J.1    Takaku, A.2
  • 2
    • 62749176396 scopus 로고    scopus 로고
    • Moyamoya Disease and Moyamoya Syndrome
    • Scott RM, Smith ER, (2009) Moyamoya Disease and Moyamoya Syndrome. N Engl J Med 360: 1226-1237.
    • (2009) N Engl J Med , vol.360 , pp. 1226-1237
    • Scott, R.M.1    Smith, E.R.2
  • 3
    • 58149359754 scopus 로고    scopus 로고
    • Whole-brain perfusion CT performed with a prototype 256-detector row CT system: initial experience
    • Murayama K, Katada K, Nakane M, Toyama H, Anno H, et al. (2009) Whole-brain perfusion CT performed with a prototype 256-detector row CT system: initial experience. Radiology 250: 202-211.
    • (2009) Radiology , vol.250 , pp. 202-211
    • Murayama, K.1    Katada, K.2    Nakane, M.3    Toyama, H.4    Anno, H.5
  • 4
    • 0942290728 scopus 로고    scopus 로고
    • Long-term outcome in children with moyamoya syndrome after cranial revascularization by pial synangiosis
    • Scott RM, Smith JL, Robertson RL, Madsen JR, Soriano SG, et al. (2004) Long-term outcome in children with moyamoya syndrome after cranial revascularization by pial synangiosis. J Neurosurg 100Suppl: 142-149.
    • (2004) J Neurosurg , vol.100 , pp. 142-149
    • Scott, R.M.1    Smith, J.L.2    Robertson, R.L.3    Madsen, J.R.4    Soriano, S.G.5
  • 5
    • 0035037004 scopus 로고    scopus 로고
    • Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable xenon CT: a validation study
    • Wintermark M, Thiran JP, Maeder P, Schnyder P, Meuli R, (2001) Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable xenon CT: a validation study. AJNR Am J Neuroradiol 22: 905-914.
    • (2001) AJNR Am J Neuroradiol , vol.22 , pp. 905-914
    • Wintermark, M.1    Thiran, J.P.2    Maeder, P.3    Schnyder, P.4    Meuli, R.5
  • 6
    • 22044451700 scopus 로고    scopus 로고
    • Prediction of the clinical outcome of pediatric moyamoya disease with postoperative basal/acetazolamide stress brain perfusion SPECT after revascularization surgery
    • So Y, Lee HY, Kim SK, Lee JS, Wang KC, et al. (2005) Prediction of the clinical outcome of pediatric moyamoya disease with postoperative basal/acetazolamide stress brain perfusion SPECT after revascularization surgery. Stroke 36: 1485-1489.
    • (2005) Stroke , vol.36 , pp. 1485-1489
    • So, Y.1    Lee, H.Y.2    Kim, S.K.3    Lee, J.S.4    Wang, K.C.5
  • 7
    • 54249092982 scopus 로고    scopus 로고
    • Which CT perfusion parameter best reflects cerebrovascular reserve?: correlation of acetazolamide-challenged CT perfusion with single-photon emission CT in Moyamoya patients
    • Rim NJ, Kim HS, Shin YS, Kim SY, (2008) Which CT perfusion parameter best reflects cerebrovascular reserve?: correlation of acetazolamide-challenged CT perfusion with single-photon emission CT in Moyamoya patients. AJNR Am J Neuroradiol 29: 1658-1663.
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 1658-1663
    • Rim, N.J.1    Kim, H.S.2    Shin, Y.S.3    Kim, S.Y.4
  • 8
    • 51649104351 scopus 로고    scopus 로고
    • Quantitative cerebrovascular reserve measured by acetazolamide-challenged dynamic CT perfusion in ischemic adult Moyamoya disease: initial experience with angiographic correlation
    • Kang KH, Kim HS, Kim SY, (2008) Quantitative cerebrovascular reserve measured by acetazolamide-challenged dynamic CT perfusion in ischemic adult Moyamoya disease: initial experience with angiographic correlation. AJNR Am J Neuroradiol 29: 1487-1493.
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 1487-1493
    • Kang, K.H.1    Kim, H.S.2    Kim, S.Y.3
  • 9
    • 0036135297 scopus 로고    scopus 로고
    • CT perfusion scanning with deconvolution analysis: pilot study in patients with acute middle cerebral artery stroke
    • Eastwood JD, Lev MH, Azhari T, Lee TY, Barboriak DP, et al. (2002) CT perfusion scanning with deconvolution analysis: pilot study in patients with acute middle cerebral artery stroke. Radiology 222: 227-236.
    • (2002) Radiology , vol.222 , pp. 227-236
    • Eastwood, J.D.1    Lev, M.H.2    Azhari, T.3    Lee, T.Y.4    Barboriak, D.P.5
  • 11
    • 41149138233 scopus 로고    scopus 로고
    • How accurate is CT angiography in evaluating intracranial atherosclerotic disease?
    • Nguyen-Huynh MN, Wintermark M, English J, Lam J, Vittinghoff E, et al. (2008) How accurate is CT angiography in evaluating intracranial atherosclerotic disease? Stroke 39: 1184-1188.
    • (2008) Stroke , vol.39 , pp. 1184-1188
    • Nguyen-Huynh, M.N.1    Wintermark, M.2    English, J.3    Lam, J.4    Vittinghoff, E.5
  • 12
    • 33645744261 scopus 로고    scopus 로고
    • Cerebral hemodynamics in Moyamoya disease: correlation between perfusion-weighted MR imaging and cerebral angiography
    • Togao O, Mihara F, Yoshiura T, Tanaka A, Noguchi T, et al. (2006) Cerebral hemodynamics in Moyamoya disease: correlation between perfusion-weighted MR imaging and cerebral angiography. AJNR Am J Neuroradiol 27: 391-397.
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 391-397
    • Togao, O.1    Mihara, F.2    Yoshiura, T.3    Tanaka, A.4    Noguchi, T.5
  • 13
    • 0035137614 scopus 로고    scopus 로고
    • Quantitative assessment of the ischemic brain by means of perfusion-related parameters derived from perfusion CT
    • Koenig M, Kraus M, Theek C, Klotz E, Gehlen W, et al. (2001) Quantitative assessment of the ischemic brain by means of perfusion-related parameters derived from perfusion CT. Stroke 32: 431-437.
    • (2001) Stroke , vol.32 , pp. 431-437
    • Koenig, M.1    Kraus, M.2    Theek, C.3    Klotz, E.4    Gehlen, W.5
  • 14
    • 80051517687 scopus 로고    scopus 로고
    • Combination of a low-tube-voltage technique with hybrid iterative reconstruction (iDose) algorithm at coronary computed tomographic angiography
    • Funama Y, Taguchi K, Utsunomiya D, Oda S, Yanaga Y, et al. (2011) Combination of a low-tube-voltage technique with hybrid iterative reconstruction (iDose) algorithm at coronary computed tomographic angiography. J Comput Assist Tomogr 35: 480-485.
    • (2011) J Comput Assist Tomogr , vol.35 , pp. 480-485
    • Funama, Y.1    Taguchi, K.2    Utsunomiya, D.3    Oda, S.4    Yanaga, Y.5
  • 16
    • 34248676588 scopus 로고    scopus 로고
    • Reproducibility of Quantitative CT Brain Perfusion Measurements in Patients with Symptomatic Unilateral Carotid Artery Stenosis.AJNR Am J Neuroradiol
    • Waaijer A, van der Schaaf IC, Velthuis BK, Quist M, van Osch MJ, et al. (2007) Reproducibility of Quantitative CT Brain Perfusion Measurements in Patients with Symptomatic Unilateral Carotid Artery Stenosis.AJNR Am J Neuroradiol. 28: 927-932.
    • (2007) , vol.28 , pp. 927-932
    • Waaijer, A.1    van der Schaaf, I.C.2    Velthuis, B.K.3    Quist, M.4    van Osch, M.J.5
  • 17
    • 36148980024 scopus 로고    scopus 로고
    • Variability of clinical CT perfusion measurements in patients with carotid stenosis
    • Turk AS, Grayev A, Rowley HA, Field AS, Turski P, et al. (2007) Variability of clinical CT perfusion measurements in patients with carotid stenosis. Neuroradiology 49: 955-961.
    • (2007) Neuroradiology , vol.49 , pp. 955-961
    • Turk, A.S.1    Grayev, A.2    Rowley, H.A.3    Field, A.S.4    Turski, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.