메뉴 건너뛰기




Volumn 32, Issue 11, 2011, Pages 1994-1999

Image quality and radiation dose of dual-energy CT of the head and neck compared with a standard 120-kVp acquisition

Author keywords

[No Author keywords available]

Indexed keywords

IOMEPROL;

EID: 84455188649     PISSN: 01956108     EISSN: 1936959X     Source Type: Journal    
DOI: 10.3174/ajnr.A2654     Document Type: Article
Times cited : (118)

References (25)
  • 1
    • 77953532930 scopus 로고    scopus 로고
    • Dual-energy CT: Clinical applications in various pulmonary diseases
    • Kang MJ, Park CM, Lee CH, et al. Dual-energy CT: clinical applications in various pulmonary diseases. Radiographics 2010;30:685-98
    • (2010) Radiographics , vol.30 , pp. 685-698
    • Kang, M.J.1    Park, C.M.2    Lee, C.H.3
  • 3
    • 74049135424 scopus 로고    scopus 로고
    • Characterization of urinary stones with dual-energy CT: Improved differentiation using a tin filter
    • Stolzmann P, Leschka S, Scheffel H, et al. Characterization of urinary stones with dual-energy CT: improved differentiation using a tin filter. Invest Radiol 2010;45:1-6
    • (2010) Invest Radiol , vol.45 , pp. 1-6
    • Stolzmann, P.1    Leschka, S.2    Scheffel, H.3
  • 4
    • 67650306387 scopus 로고    scopus 로고
    • Dual-energy CT for the assessment of contrast material distribution in the pulmonary parenchyma
    • Thieme SF, Johnson TR, Lee C, et al. Dual-energy CT for the assessment of contrast material distribution in the pulmonary parenchyma. AJR Am J Roentgenol 2009;193:144-49
    • (2009) AJR Am J Roentgenol , vol.193 , pp. 144-149
    • Thieme, S.F.1    Johnson, T.R.2    Lee, C.3
  • 5
    • 67651037373 scopus 로고    scopus 로고
    • Cervical and cranial computed tomographic angiography with automated bone removal: Dual energy computed tomography versus standard computed tomography
    • Morhard D, Fink C, Graser A, et al. Cervical and cranial computed tomographic angiography with automated bone removal: dual energy computed tomography versus standard computed tomography. Invest Radiol 2009;44:293-97
    • (2009) Invest Radiol , vol.44 , pp. 293-297
    • Morhard, D.1    Fink, C.2    Graser, A.3
  • 6
    • 67651047052 scopus 로고    scopus 로고
    • The value of dual-energy bone removal in maximum intensity projections of lower extremity computed tomography angiography
    • Sommer WH, Johnson TR, Becker CR, et al. The value of dual-energy bone removal in maximum intensity projections of lower extremity computed tomography angiography. Invest Radiol 2009;44:285-92
    • (2009) Invest Radiol , vol.44 , pp. 285-292
    • Sommer, W.H.1    Johnson, T.R.2    Becker, C.R.3
  • 7
    • 65349110338 scopus 로고    scopus 로고
    • Image fusion in dual energy computed tomography: Effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography
    • Behrendt FF, Schmidt B, Plumhans C, et al. Image fusion in dual energy computed tomography: effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography. Invest Radiol 2009;44:1-6
    • (2009) Invest Radiol , vol.44 , pp. 1-6
    • Behrendt, F.F.1    Schmidt, B.2    Plumhans, C.3
  • 8
    • 77249102129 scopus 로고    scopus 로고
    • Image fusion in dual energy computed tomography for detection of hypervascular liver hepatocellular carcinoma: Phantom and preliminary studies
    • Kim KS, Lee JM, Kim SH, et al. Image fusion in dual energy computed tomography for detection of hypervascular liver hepatocellular carcinoma: phantom and preliminary studies. Invest Radiol 2010;45:149-57
    • (2010) Invest Radiol , vol.45 , pp. 149-157
    • Kim, K.S.1    Lee, J.M.2    Kim, S.H.3
  • 9
    • 56349125645 scopus 로고    scopus 로고
    • Evaluation of non-linear blending in dual-energy computed tomography
    • HolmesDR3rd, Fletcher JG, Apel A, et al. Evaluation of non-linear blending in dual-energy computed tomography. Eur J Radiol 2008;3:409-13
    • (2008) Eur J Radiol , vol.3 , pp. 409-413
    • Holmes III, D.R.1    Fletcher, J.G.2    Apel, A.3
  • 10
    • 70249111173 scopus 로고    scopus 로고
    • Dual-energy CT in patients suspected of having renal masses: Can virtual nonenhanced images replace true nonenhanced images?
    • Graser A, Johnson TR, Hecht EM, et al. Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images? Radiology 2009;252:433-40
    • (2009) Radiology , vol.252 , pp. 433-440
    • Graser, A.1    Johnson, T.R.2    Hecht, E.M.3
  • 11
    • 74749095789 scopus 로고    scopus 로고
    • Dual-source dual-energy MDCT of pancreatic adenocarcinoma: Initial observations with data generated at 80 kVp and at simulated weighted-average 120 kVp
    • Macari M, Spieler B, Kim D, et al. Dual-source dual-energy MDCT of pancreatic adenocarcinoma: initial observations with data generated at 80 kVp and at simulated weighted-average 120 kVp. AJR Am J Roentgenol 2010;194:27-32
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 27-32
    • Macari, M.1    Spieler, B.2    Kim, D.3
  • 12
    • 76449085563 scopus 로고    scopus 로고
    • Dual-energy computed tomographic pulmonary angiography: A pilot study to assess the effect on image quality and diagnostic confidence
    • Sangwaiya, Kalra MK, Sharma A, et al. Dual-energy computed tomographic pulmonary angiography: a pilot study to assess the effect on image quality and diagnostic confidence. J Comput Assist Tomogr 2010;34:46-51
    • (2010) J Comput Assist Tomogr , vol.34 , pp. 46-51
    • Sangwaiya1    Kalra, M.K.2    Sharma, A.3
  • 13
    • 33751228740 scopus 로고    scopus 로고
    • Optimization of Z-axis automatic exposure control for multidetector row CT evaluation of neck and comparison with fixed tube current technique for image quality and radiation dose
    • Namasivayam S, Kalra MK, Pottala KM, et al. Optimization of Z-axis automatic exposure control for multidetector row CT evaluation of neck and comparison with fixed tube current technique for image quality and radiation dose. AJNR Am J Neuroradiol 2006;27:2221-25 (Pubitemid 44788661)
    • (2006) American Journal of Neuroradiology , vol.27 , Issue.10 , pp. 2221-2225
    • Namasivayam, S.1    Kalra, M.K.2    Pottala, K.M.3    Waldrop, S.M.4    Hudgins, P.A.5
  • 14
    • 22544435185 scopus 로고    scopus 로고
    • Comparison of different body size parameters for individual dose adaptation in body CT of adults
    • DOI 10.1148/radiol.2362041327
    • Menke J. Comparison of different body size parameters for individual dose adaptation in body CT of adults. Radiology 2005;236:565-71 (Pubitemid 41023441)
    • (2005) Radiology , vol.236 , Issue.2 , pp. 565-571
    • Menke, J.1
  • 17
    • 84855676937 scopus 로고    scopus 로고
    • 5 August 5, Accessed January 15, 2011
    • Bundesamt für Strahlenschutz. Bundesanzeiger No. 143. 5 August 5, 2003: 17503. http://www.bfs.de/de/ion/medizin/referenzwerte02.pdf. Accessed January 15, 2011
    • (2003) Bundesanzeiger No. 143 , pp. 17503
  • 18
    • 62849105461 scopus 로고    scopus 로고
    • Comparison of the image quality of various fixed and dose modulated protocols for soft tissue neck CT on a GE Lightspeed scanner
    • Epub 2008 Jan 7
    • Weidemann J, Stamm G, Galanski M, et al. Comparison of the image quality of various fixed and dose modulated protocols for soft tissue neck CT on a GE Lightspeed scanner. Eur J Radiol 2009;69:473-77. Epub 2008 Jan 7
    • (2009) Eur J Radiol , vol.69 , pp. 473-477
    • Weidemann, J.1    Stamm, G.2    Galanski, M.3
  • 19
    • 25144433343 scopus 로고    scopus 로고
    • Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: Clinical evaluation
    • DOI 10.1148/radiol.2363041220
    • Mulkens TH, Bellinck P, Baeyaert M, et al. Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. Radiology 2005;237:213-23 (Pubitemid 41346166)
    • (2005) Radiology , vol.237 , Issue.1 , pp. 213-223
    • Mulkens, T.H.1    Bellinck, P.2    Baeyaert, M.3    Ghysen, D.4    Van Dijck, X.5    Mussen, E.6    Venstermans, C.7    Termote, J.-L.8
  • 20
    • 0037448795 scopus 로고    scopus 로고
    • Radiation dose in computed tomography of the heart
    • DOI 10.1161/01.CIR.0000048965.56529.C2
    • Morin RL, Gerber TC, McCollough CH. Radiation dose in computed tomography of the heart. Circulation 2003;107:917-22 (Pubitemid 36241053)
    • (2003) Circulation , vol.107 , Issue.6 , pp. 917-922
    • Morin, R.L.1    Gerber, T.C.2    McCollough, C.H.3
  • 21
    • 59249098264 scopus 로고    scopus 로고
    • Dual energy CT: Preliminary observations and potential clinical applications in the abdomen
    • Graser A, Johnson TR, Chandarana H, et al. Dual energy CT: preliminary observations and potential clinical applications in the abdomen. Eur Radiol 2009;19:13-23
    • (2009) Eur Radiol , vol.19 , pp. 13-23
    • Graser, A.1    Johnson, T.R.2    Chandarana, H.3
  • 23
    • 70349759467 scopus 로고    scopus 로고
    • Dual energy versus single energy MDCT: Measurement of radiation dose using adult abdominal imaging protocols
    • Ho LM, Yoshizumi TT, Hurwitz LM, et al. Dual energy versus single energy MDCT: measurement of radiation dose using adult abdominal imaging protocols. Acad Radiol 2009;16:1400-07
    • (2009) Acad Radiol , vol.16 , pp. 1400-1407
    • Ho, L.M.1    Yoshizumi, T.T.2    Hurwitz, L.M.3
  • 24
    • 77952481687 scopus 로고    scopus 로고
    • Dual energy CT of the chest: How about the dose?
    • Schenzle JC, Sommer WH, Neumaier K, et al. Dual energy CT of the chest: how about the dose? Invest Radiol 2010;45:347-53
    • (2010) Invest Radiol , vol.45 , pp. 347-353
    • Schenzle, J.C.1    Sommer, W.H.2    Neumaier, K.3
  • 25
    • 67049172574 scopus 로고    scopus 로고
    • Hypervascular liver tumors: Low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection - Initial clinical experience
    • Marin D, Nelson RC, Samei E, et al. Hypervascular liver tumors: low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection - initial clinical experience. Radiology 2009;251:771-79
    • (2009) Radiology , vol.251 , pp. 771-779
    • Marin, D.1    Nelson, R.C.2    Samei, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.