메뉴 건너뛰기




Volumn 10, Issue 3, 2014, Pages 339-346

Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement

Author keywords

Aortic annulus; Sizing; Transcatheter aortic valve replacement

Indexed keywords

AGED; AORTA VALVE; AORTIC ANNULUS AREA; AORTIC ANNULUS MAXIMUM DIAMETER; AORTIC ANNULUS MINIMUM DIAMETER; AORTIC ANNULUS PERIMETER; AORTIC ANNULUS VIRTUAL DIAMETER; AORTIC ROOT SURGERY; ARTICLE; BLOOD VESSEL PARAMETERS; CONTROLLED STUDY; CONVENTIONAL ANGIOGRAPHY; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MEASUREMENT ACCURACY; MULTIDETECTOR COMPUTED TOMOGRAPHY; PREDICTIVE VALUE; PREOPERATIVE EVALUATION; REPRODUCIBILITY; THREE DIMENSIONAL IMAGING; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; AORTIC VALVE STENOSIS; COMPUTER ASSISTED DIAGNOSIS; COMPUTER PROGRAM; DEVICES; ECHOGRAPHY; HEART CATHETERIZATION; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; LABORATORY AUTOMATION; OBSERVER VARIATION; PROCEDURES; PROSPECTIVE STUDY; PROSTHESIS; RADIOGRAPHY; RETROSPECTIVE STUDY; VERY ELDERLY;

EID: 84905442041     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV10I3A59     Document Type: Article
Times cited : (27)

References (20)
  • 4
    • 70349396032 scopus 로고    scopus 로고
    • Determinants of significant paravalvular regurgitation after transcatheter aortic valve: Implantation impact of device and annulus discongruence
    • Détaint D, Lepage L, Himbert D, Brochet E, Messika-Zeitoun D, Iung B, Vahanian A. Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence. JACC Cardiovasc Interv. 2009;2:821-7.
    • (2009) JACC Cardiovasc Interv , vol.2 , pp. 821-827
    • Détaint, D.1    Lepage, L.2    Himbert, D.3    Brochet, E.4    Messika-Zeitoun, D.5    Iung, B.6    Vahanian, A.7
  • 11
    • 84855403987 scopus 로고    scopus 로고
    • Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: Insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy
    • Hamdan A, Guetta V, Konen E, Goitein O, Segev A, Raanani E, Spiegelstein D, Hay I, Di Segni E, Eldar M, Schwammenthal E. Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy. J Am Coll Cardiol. 2012;59:119-27.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 119-127
    • Hamdan, A.1    Guetta, V.2    Konen, E.3    Goitein, O.4    Segev, A.5    Raanani, E.6    Spiegelstein, D.7    Hay, I.8    Di Segni, E.9    Eldar, M.10    Schwammenthal, E.11
  • 17
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989;45:255-68.
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.1
  • 19
    • 84859164235 scopus 로고    scopus 로고
    • Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation
    • Jilaihawi H, Kashif M, Fontana G, Furugen A, Shiota T, Friede G, Makhija R, Doctor N, Leon MB, Makkar RR. Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol. 2012;59:1275-86.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1275-1286
    • Jilaihawi, H.1    Kashif, M.2    Fontana, G.3    Furugen, A.4    Shiota, T.5    Friede, G.6    Makhija, R.7    Doctor, N.8    Leon, M.B.9    Makkar, R.R.10
  • 20
    • 84863616730 scopus 로고    scopus 로고
    • Evaluation of aortic root for definition of prosthesis size by magnetic resonance imaging and cardiac computed tomography: Implications for transcatheter aortic valve implantation
    • Koos R, Altiok E, Mahnken AH, Neizel M, Dohmen G, Marx N, Kühl H, Hoffmann R. Evaluation of aortic root for definition of prosthesis size by magnetic resonance imaging and cardiac computed tomography: implications for transcatheter aortic valve implantation. Int J Cardiol. 2012;158:353-8.
    • (2012) Int J Cardiol , vol.158 , pp. 353-358
    • Koos, R.1    Altiok, E.2    Mahnken, A.H.3    Neizel, M.4    Dohmen, G.5    Marx, N.6    Kühl, H.7    Hoffmann, R.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.