메뉴 건너뛰기




Volumn 31, Issue 8, 2014, Pages 404-410

Performance of acceleromyography with a short and light TOF-tube compared with mechanomyography: A clinical comparison

Author keywords

[No Author keywords available]

Indexed keywords

ACCELEROMYOGRAPHY; ACCURACY; ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; HUMAN; INTERMETHOD COMPARISON; ISOMETRICS; LIGHT; MALE; MECHANOMYOGRAPHY; MYOGRAPHY; NEUROMUSCULAR TRANSMISSION; OUTCOME ASSESSMENT; PERFORMANCE; PROTECTIVE EQUIPMENT; SHORT AND LIGHT TRAIN OF FOUR TUBE; ACCELEROMETRY; ADOLESCENT; CALIBRATION; CLINICAL TRIAL; COMPARATIVE STUDY; DEVICES; DRUG EFFECTS; GENERAL ANESTHESIA; LEG; MIDDLE AGED; MUSCLE CONTRACTION; MUSCLE ISOMETRIC CONTRACTION; NEUROMUSCULAR BLOCKING; ORTHOPEDIC SURGERY; PATIENT MONITORING; PHYSIOLOGY; PROCEDURES; REPRODUCIBILITY; SURGERY; VERY ELDERLY; YOUNG ADULT;

EID: 84905438857     PISSN: 02650215     EISSN: 13652346     Source Type: Journal    
DOI: 10.1097/EJA.0b013e3283645691     Document Type: Article
Times cited : (14)

References (26)
  • 1
    • 77954661848 scopus 로고    scopus 로고
    • Evidence-based management of neuromuscular block
    • Viby-Mogensen J, Claudius C. Evidence-based management of neuromuscular block. Anesth Analg 2010; 111:1-2.
    • (2010) Anesth Analg , vol.111 , pp. 1-2
    • Viby-Mogensen, J.1    Claudius, C.2
  • 2
    • 77954667679 scopus 로고    scopus 로고
    • Residual neuromuscular block: Lessons unlearned. Part ii: Methods to reduce the risk of residual weakness
    • Brull SJ, Murphy GS. Residual neuromuscular block: lessons unlearned. Part II: methods to reduce the risk of residual weakness. Anesth Analg 2010; 111:129-140.
    • (2010) Anesth Analg , vol.111 , pp. 129-140
    • Brull, S.J.1    Murphy, G.S.2
  • 3
    • 45149131371 scopus 로고    scopus 로고
    • Acceleromyography for use in scientific and clinical practice. A systematic review of the evidence
    • Claudius C, Viby-Mogensen J. Acceleromyography for use in scientific and clinical practice. A systematic review of the evidence. Anesthesiology 2008; 108:1117-1140.
    • (2008) Anesthesiology , vol.108 , pp. 1117-1140
    • Claudius, C.1    Viby-Mogensen, J.2
  • 6
    • 36649031268 scopus 로고    scopus 로고
    • Clinical validation of electromyography and acceleromyography as sensors for muscle relaxation
    • Hänzi P, Leibundgur D, Wessendorf R, et al. Clinical validation of electromyography and acceleromyography as sensors for muscle relaxation. Eur J Anaesthesiol 2007; 24:882-888.
    • (2007) Eur J Anaesthesiol , vol.24 , pp. 882-888
    • Hänzi, P.1    Leibundgur, D.2    Wessendorf, R.3
  • 7
    • 77954684148 scopus 로고    scopus 로고
    • A survey of current management of neuromuscular block in the united states and europe
    • Naguib M, Kopman A, Lien C, et al. A survey of current management of neuromuscular block in the United States and Europe. Anesth Analg 2010; 111:110-119.
    • (2010) Anesth Analg , vol.111 , pp. 110-119
    • Naguib, M.1    Kopman, A.2    Lien, C.3
  • 8
    • 15944424341 scopus 로고    scopus 로고
    • Acceleromyography vs. Electromyography: An ipsilateral comparison of the indirectly evoked neuromuscular response to train-of-four stimulation
    • Kopman AF, Chin W, Cyriac J. Acceleromyography vs. electromyography: an ipsilateral comparison of the indirectly evoked neuromuscular response to train-of-four stimulation. Acta Anaesthesiol Scand 2005; 49:316-322.
    • (2005) Acta Anaesthesiol Scand , vol.49 , pp. 316-322
    • Kopman, A.F.1    Chin, W.2    Cyriac, J.3
  • 9
    • 0036187013 scopus 로고    scopus 로고
    • The relationship between acceleromyographic train-of-four fade and single twitch depression
    • Kopman AF, Klewicka MM, Neuman GG. The relationship between acceleromyographic train-of-four fade and single twitch depression. Anesthesiology 2002; 96:583-587.
    • (2002) Anesthesiology , vol.96 , pp. 583-587
    • Kopman, A.F.1    Klewicka, M.M.2    Neuman, G.G.3
  • 10
    • 2142641605 scopus 로고    scopus 로고
    • Can acceleromyography detect low levels of residual paralysis? A probability approach to detect a mechanomyographic train-of-four ratio of 0.9
    • Capron F, Alla F, Hottier C, et al. Can acceleromyography detect low levels of residual paralysis? A probability approach to detect a mechanomyographic train-of-four ratio of 0.9. Anesthesiology 2004; 100:1119-1124.
    • (2004) Anesthesiology , vol.100 , pp. 1119-1124
    • Capron, F.1    Alla, F.2    Hottier, C.3
  • 11
    • 67049117489 scopus 로고    scopus 로고
    • Is the performance of acceleromyography improved with preload and normalization? A comparison with mechanomyography
    • Claudius C, Skovgaard LT, Viby-Mogensen J. Is the performance of acceleromyography improved with preload and normalization? A comparison with mechanomyography. Anesthesiology 2009; 110:1261-11270.
    • (2009) Anesthesiology , vol.110 , pp. 1261-11270
    • Claudius, C.1    Skovgaard, L.T.2    Viby-Mogensen, J.3
  • 13
    • 0036370662 scopus 로고    scopus 로고
    • Tof-tube: A new protection for acceleromyography. A comparison with the organon tof-guard/tofwatch arm board
    • Dubois PE, Broka SM, Jamart J, Joucken KL. TOF-Tube: a new protection for acceleromyography. A comparison with the Organon TOF-Guard/TOFWatch arm board. Acta Anaesth Belg 2002; 53:33-38.
    • (2002) Acta Anaesth Belg , vol.53 , pp. 33-38
    • Dubois, P.E.1    Broka, S.M.2    Jamart, J.3    Joucken, K.L.4
  • 14
    • 21744461123 scopus 로고    scopus 로고
    • Installation of the hand influences acceleromyography measurement. A comparison with mechanomyography during neuromuscular block recovery
    • Dubois PE, Gourdin M, Russell K, Jamart J. Installation of the hand influences acceleromyography measurement. A comparison with mechanomyography during neuromuscular block recovery. Acta Anaesth Belg 2005; 56:163-166.
    • (2005) Acta Anaesth Belg , vol.56 , pp. 163-166
    • Dubois, P.E.1    Gourdin, M.2    Russell, K.3    Jamart, J.4
  • 15
    • 34447312844 scopus 로고    scopus 로고
    • Good clinical research practice in pharmacodynamic studies of neuromuscular blocking agents ii: The stockholm revision
    • Fuchs-Buder T, Claudius C, Skovgaard LT, et al. Good clinical research practice in pharmacodynamic studies of neuromuscular blocking agents II: the Stockholm revision. Acta Anaesthesiol Scand 2007; 51:789-808.
    • (2007) Acta Anaesthesiol Scand , vol.51 , pp. 789-808
    • Fuchs-Buder, T.1    Claudius, C.2    Skovgaard, L.T.3
  • 16
    • 84905506681 scopus 로고    scopus 로고
    • Mustimeg: A new device for polytopic emg as perioperative neuromuscular monitoring
    • Cantraine F, De Bel M, Baurain M, et al. MUSTIMEG: A new device for polytopic EMG as perioperative neuromuscular monitoring. Eur J Anaesthesiol 2009; 26 (Suppl 45):31.
    • (2009) Eur J Anaesthesiol , vol.26 , Issue.SUPPL. 45 , pp. 31
    • Cantraine, F.1    De Bel, M.2    Baurain, M.3
  • 17
    • 31144449856 scopus 로고    scopus 로고
    • Normalization of acceleromyographic train-of-four ratio by baseline value for detecting residual neuromuscular block
    • Suzuki T, Fukano N, Kitajima O, et al. Normalization of acceleromyographic train-of-four ratio by baseline value for detecting residual neuromuscular block. Br J Anaesth 2006; 96:44-47.
    • (2006) Br J Anaesth , vol.96 , pp. 44-47
    • Suzuki, T.1    Fukano, N.2    Kitajima, O.3
  • 18
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Meth Med Res 1999; 8:135-160.
    • (1999) Stat Meth Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 34547145165 scopus 로고    scopus 로고
    • G-power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences
    • Faul F, Erdfelder E, Lang AG, Buchner A. G-Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Meth 2007; 39:175-191.
    • (2007) Behav Res Meth , vol.39 , pp. 175-191
    • Faul, F.1    Erdfelder, E.2    Lang, A.G.3    Buchner, A.4
  • 20
    • 0031981803 scopus 로고    scopus 로고
    • New equipment for neuromuscular transmission monitoring: A comparison of the tof-guard with the myograph 2000
    • Kirkegaard-Nielsen H, Helbo-Hansen HS, Lindholm P, et al. New equipment for neuromuscular transmission monitoring: a comparison of the TOF-Guard with the Myograph 2000. J Clin Monit Comput 1998; 14:19-27.
    • (1998) J Clin Monit Comput , vol.14 , pp. 19-27
    • Kirkegaard-Nielsen, H.1    Helbo-Hansen, H.S.2    Lindholm, P.3
  • 21
    • 77956050425 scopus 로고    scopus 로고
    • Arm-to-arm variation when evaluating neuromuscular block: An analysis of the precision and the bias and agreement between arms when using mechanomyography or acceleromyography
    • Claudius C, Skovgaard LT, Viby-Mogensen J. Arm-to-arm variation when evaluating neuromuscular block: an analysis of the precision and the bias and agreement between arms when using mechanomyography or acceleromyography. Br J Anaesth 2010; 105:310-317.
    • (2010) Br J Anaesth , vol.105 , pp. 310-317
    • Claudius, C.1    Skovgaard, L.T.2    Viby-Mogensen, J.3
  • 22
    • 0036076987 scopus 로고    scopus 로고
    • Measurement and monitoring of neuromuscular blockade
    • Kopman AF. Measurement and monitoring of neuromuscular blockade. Curr Opin Anaesthesiol 2002; 15:415-420.
    • (2002) Curr Opin Anaesthesiol , vol.15 , pp. 415-420
    • Kopman, A.F.1
  • 23
    • 0028920168 scopus 로고
    • Real time versus slow motion train-of-four monitoring: A theory to explain the inaccuracy of visual assessment
    • Brull SJ, Silverman DS. Real time versus slow motion train-of-four monitoring: a theory to explain the inaccuracy of visual assessment. Anesth Analg 1995; 80:548-551.
    • (1995) Anesth Analg , vol.80 , pp. 548-551
    • Brull, S.J.1    Silverman, D.S.2
  • 24
    • 79751499577 scopus 로고    scopus 로고
    • Acceleromyography to assess neuromuscular recovery: Is calibration before measurement mandatory?
    • Schreiber JU, Mucha E, Fuchs-Buder T. Acceleromyography to assess neuromuscular recovery: is calibration before measurement mandatory? Acta Anaesthesiol Scand 2011; 55:328-331.
    • (2011) Acta Anaesthesiol Scand , vol.55 , pp. 328-331
    • Schreiber, J.U.1    Mucha, E.2    Fuchs-Buder, T.3
  • 25
    • 77954675796 scopus 로고    scopus 로고
    • Monitoring and pharmacological reversal of a nondepolarizing neuromuscular blockade should be routine
    • Miller RD, Ward TA. Monitoring and pharmacological reversal of a nondepolarizing neuromuscular blockade should be routine. Anesth Analg 2010; 111:3-5.
    • (2010) Anesth Analg , vol.111 , pp. 3-5
    • Miller, R.D.1    Ward, T.A.2
  • 26
    • 84905499111 scopus 로고    scopus 로고
    • Clinical evaluation of the tof-tube
    • A128
    • Dubois PE. Clinical evaluation of the TOF-Tube. Eur J Anaesthesiol 2005; 22 (Suppl 34):35; (A128).
    • (2005) Eur J Anaesthesiol , vol.22 , Issue.SUPPL. 34 , pp. 35
    • Dubois, P.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.