메뉴 건너뛰기




Volumn 53, Issue 1, 2002, Pages 33-38

TOF-tube, a new protection for acceleromyography, compared with the TOF-Guard®/TOF-Watch® arm board

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DRUG EFFECT; FEMALE; GENERAL ANESTHESIA; HAND; HUMAN; INSTRUMENTATION; MALE; MIDDLE AGED; MOTOR ACTIVITY; MOVEMENT (PHYSIOLOGY); NEUROMUSCULAR BLOCKING; PATIENT MONITORING; PHYSIOLOGY; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; SKIN TEMPERATURE;

EID: 0036370662     PISSN: 00015164     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (8)
  • 1
    • 0023855388 scopus 로고
    • Measurement of acceleration : A new method of monitoring neuromuscular function
    • Viby-Mogensen J., Jensen E., Werner M., et al., Measurement of acceleration : a new method of monitoring neuromuscular function, ACTA ANAESTHESIOL. SCAND., 32, 45-8, 1988.
    • (1988) Acta Anaesthesiol. Scand. , vol.32 , pp. 45-48
    • Viby-Mogensen, J.1    Jensen, E.2    Werner, M.3
  • 2
    • 0025049192 scopus 로고
    • Accurate monitoring of neuromuscular blockade using a peripheral nerve stimulator - A review
    • Beemer G. H., Reeves J. H., Bjorksten A. R., Accurate monitoring of neuromuscular blockade using a peripheral nerve stimulator - a review, ANAESTH INTENS CARE, 18, 490-6, 1990.
    • (1990) Anaesth Intens Care , vol.18 , pp. 490-496
    • Beemer, G.H.1    Reeves, J.H.2    Bjorksten, A.R.3
  • 4
    • 0030050370 scopus 로고    scopus 로고
    • Good clinical research practice in pharmacodynamic studies of neuromuscular blocking agents
    • Viby-Mogensen J., Engbaek J., Eriksson L. I., et al., Good clinical research practice in pharmacodynamic studies of neuromuscular blocking agents, ACTA ANAESTHESIOL. SCAND., 40, 59-74, 1996.
    • (1996) Acta Anaesthesiol. Scand. , vol.40 , pp. 59-74
    • Viby-Mogensen, J.1    Engbaek, J.2    Eriksson, L.I.3
  • 5
    • 0029133897 scopus 로고
    • Pulse width, stimulus intensity, electrode placement, and polarity during assessment of neuromuscular block
    • Brull S. J., Silverman D. G., Pulse width, stimulus intensity, electrode placement, and polarity during assessment of neuromuscular block, ANESTHESIOLOGY, 83, 702-9, 1995.
    • (1995) Anesthesiology , vol.83 , pp. 702-709
    • Brull, S.J.1    Silverman, D.G.2
  • 6
    • 0021183543 scopus 로고
    • Milliamperage requirements for supramaximal stimulation of the ulnar nerve with surface electrodes
    • Kopman A. F., Lawson D., Milliamperage requirements for supramaximal stimulation of the ulnar nerve with surface electrodes, ANESTHESIOLOGY, 61, 83-5, 1984.
    • (1984) Anesthesiology , vol.61 , pp. 83-85
    • Kopman, A.F.1    Lawson, D.2
  • 7
    • 0041151089 scopus 로고    scopus 로고
    • Hypothermia and neuromuscular block
    • Butterworth Heinemann, Oxford
    • Feldman S. A., Hypothermia and neuromuscular block. In : Neuromuscular block. Butterworth Heinemann, Oxford, 128-40, 1996.
    • (1996) Neuromuscular Block , pp. 128-140
    • Feldman, S.A.1
  • 8
    • 0028920168 scopus 로고
    • Real time versus slow-motion train-of-four monitoring: A theory to explain the inaccuracy of visual assessment
    • Brull S. J., Silverman D. G., Real time versus slow-motion train-of-four monitoring: a theory to explain the inaccuracy of visual assessment, ANESTH. ANALG., 80, 548-51, 1995.
    • (1995) Anesth. Analg. , vol.80 , pp. 548-551
    • Brull, S.J.1    Silverman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.