-
1
-
-
61849183509
-
Monitoring neuromuscular block
-
Anaesthesia.
-
Fuchs-Buder T, Schreiber JU, Meistelman C., Monitoring neuromuscular block: an update. Anaesthesia 2009; 64 (Suppl. 1): 82-9.
-
(2009)
An Update
, vol.64
, Issue.SUPPL. 1
, pp. 82-89
-
-
Fuchs-Buder, T.1
Schreiber, J.U.2
Meistelman, C.3
-
2
-
-
34447312844
-
Good clinical research practice in pharmacodynamic studies of neuromuscular blocking agents II: The Stockholm revision
-
DOI 10.1111/j.1399-6576.2007.01352.x
-
Fuchs-Buder T, Claudius C, Skovgaard LT, Eriksson LI, Mirakhur RK, Viby-Mogensen J., Good clinical research practice in pharmacodynamic studies of neuromuscular blocking agents II: the Stockholm revision. Acta Anaesthesiol Scand 2007; 51: 789-808. (Pubitemid 47063004)
-
(2007)
Acta Anaesthesiologica Scandinavica
, vol.51
, Issue.7
, pp. 789-808
-
-
Fuchs-Buder, T.1
Claudius, C.2
Skovgaard, L.T.3
Eriksson, L.I.4
Mirakhur, R.K.5
Viby-Mogensen, J.6
-
3
-
-
11444255589
-
Single acceleromyographic train-of-four, 100-Hertz tetanus or double-burst stimulatio
-
Anesthesiology.
-
Samet A, Capron F, Alla F, Meistelman C, Fuchs-Buder T., Single acceleromyographic train-of-four, 100-Hertz tetanus or double-burst stimulatio: which test performs better to detect residual paralysis? Anesthesiology 2005; 102: 51-6.
-
(2005)
Which Test Performs Better to Detect Residual Paralysis?
, vol.102
, pp. 51-56
-
-
Samet, A.1
Capron, F.2
Alla, F.3
Meistelman, C.4
Fuchs-Buder, T.5
-
4
-
-
33646200763
-
Tactile fade detection with hand or wrist stimulation using train-of-four, double-burst stimulation, 50-hertz tetanus, 100-hertz tetanus, and acceleromyography
-
Capron F, Fortier LP, Racine S, Donati F., Tactile fade detection with hand or wrist stimulation using train-of-four, double-burst stimulation, 50-hertz tetanus, 100-hertz tetanus, and acceleromyography. Anesth Analg 2006; 102: 1578-84.
-
(2006)
Anesth Analg
, vol.102
, pp. 1578-1584
-
-
Capron, F.1
Fortier, L.P.2
Racine, S.3
Donati, F.4
-
5
-
-
50849154436
-
Neostigmine but not sugammadex impairs upper airway dilator muscle activity and breathing
-
Eikermann M, Zaremba S, Malhotra A, Jordan AS, Rosow C, Chamberlin NL., Neostigmine but not sugammadex impairs upper airway dilator muscle activity and breathing. Br J Anaesth 2008; 101: 344-9.
-
(2008)
Br J Anaesth
, vol.101
, pp. 344-349
-
-
Eikermann, M.1
Zaremba, S.2
Malhotra, A.3
Jordan, A.S.4
Rosow, C.5
Chamberlin, N.L.6
-
7
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
PII S0140673686908378
-
Bland JM, Altman DG., Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-10. (Pubitemid 16134762)
-
(1986)
Lancet
, vol.1
, Issue.8476
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
8
-
-
0036197210
-
Postoperative muscle paralysis after rocuronium
-
Acta Anaesthesiol Scand.
-
Gatke MR, Viby-Mogensen J, Rosenstock C, Jensen FS, Skovgaard LT., Postoperative muscle paralysis after rocuronium: less residual block when acceleromyography is used. Acta Anaesthesiol Scand 2002; 46: 207-13.
-
(2002)
Less Residual Block When Acceleromyography Is Used
, vol.46
, pp. 207-213
-
-
Gatke, M.R.1
Viby-Mogensen, J.2
Rosenstock, C.3
Jensen, F.S.4
Skovgaard, L.T.5
-
9
-
-
0347363660
-
Antagonism of cisatracurium and rocuronium block at a tactile train-of-four count of 2
-
Anesth Analg.
-
Kopman AF, Zank LM, Ng J, Neuman GG., Antagonism of cisatracurium and rocuronium block at a tactile train-of-four count of 2: should quantitative assessment of neuromuscular function be mandatory? Anesth Analg 2004; 98: 102-6.
-
(2004)
Should Quantitative Assessment of Neuromuscular Function Be Mandatory?
, vol.98
, pp. 102-106
-
-
Kopman, A.F.1
Zank, L.M.2
Ng, J.3
Neuman, G.G.4
-
10
-
-
45149131371
-
Acceleromyography for use in scientific and clinical practice
-
Anesthesiology.
-
Claudius C, Viby-Mogensen J., Acceleromyography for use in scientific and clinical practice: a systematic review of the evidence. Anesthesiology 2008; 108: 1117-40.
-
(2008)
A Systematic Review of the Evidence
, vol.108
, pp. 1117-1140
-
-
Claudius, C.1
Viby-Mogensen, J.2
-
11
-
-
2142641605
-
Can Acceleromyography Detect Low Levels of Residual Paralysis? A Probability Approach to Detect a Mechanomyographic Train-of-four Ratio of 0.9
-
DOI 10.1097/00000542-200405000-00013
-
Capron F, Alla F, Hottier C, Meistelman C, Fuchs-Buder T., Can acceleromyography detect low levels of residual paralysis A probability approach to detect a mechanomyographic train-of-four ratio of 0.9. Anesthesiology 2004; 100: 1119-24. (Pubitemid 38541966)
-
(2004)
Anesthesiology
, vol.100
, Issue.5
, pp. 1119-1124
-
-
Capron, F.1
Alla, F.2
Hottier, C.3
Meistelman, C.4
Fuchs-Buder, T.5
-
12
-
-
31144449856
-
Normalization of acceleromyographic train-of-four ratio by baseline value for detecting residual neuromuscular block
-
DOI 10.1093/bja/aei273
-
Suzuki T, Fukano N, Kitajima O, Saeki S, Ogawa S., Normalization of acceleromyographic train-of-four ratio by baseline value for detecting residual neuromuscular block. Br J Anaesth 2006; 96: 44-7. (Pubitemid 43124529)
-
(2006)
British Journal of Anaesthesia
, vol.96
, Issue.1
, pp. 44-47
-
-
Suzuki, T.1
Fukano, N.2
Kitajima, O.3
Saeki, S.4
Ogawa, S.5
-
13
-
-
0026546922
-
The accuracy of train-of-four monitoring at varying stimulating currents
-
Helbo-Hansen HS, Bang U, Nielsen HK, Skovgaard LT., The accuracy of train-of-four monitoring at varying stimulating currents. Anesthesiology 1992; 76: 199-203.
-
(1992)
Anesthesiology
, vol.76
, pp. 199-203
-
-
Helbo-Hansen, H.S.1
Bang, U.2
Nielsen, H.K.3
Skovgaard, L.T.4
-
14
-
-
67049117489
-
Is the performance of acceleromyography improved with preload and normalization? A comparison with mechanomyography
-
Claudius C, Skovgaard LT, Viby-Mogensen J., Is the performance of acceleromyography improved with preload and normalization? A comparison with mechanomyography. Anesthesiology 2009; 110: 1261-70.
-
(2009)
Anesthesiology
, vol.110
, pp. 1261-1270
-
-
Claudius, C.1
Skovgaard, L.T.2
Viby-Mogensen, J.3
|