메뉴 건너뛰기




Volumn 14, Issue 4, 2014, Pages 241-248

Diagnostic performance of dedicated positron emission mammography using fluorine-18-fluorodeoxyglucose in women with suspicious breast lesions: A meta-analysis

Author keywords

Accuracy of diagnostic studies; Breast malignancy; PEM; Sensitivity and specificity; Statistical pooled evaluation

Indexed keywords

FLUORODEOXYGLUCOSE F 18; RADIOPHARMACEUTICAL AGENT;

EID: 84904706478     PISSN: 15268209     EISSN: 19380666     Source Type: Journal    
DOI: 10.1016/j.clbc.2013.12.004     Document Type: Article
Times cited : (52)

References (30)
  • 2
    • 70449575388 scopus 로고    scopus 로고
    • Improved breast cancer survival following introduction of an organized mammography screening program among both screened and unscreened women: A population-based cohort study
    • M. Kalager, T. Haldorsen, and M. Bretthauer et al. Improved breast cancer survival following introduction of an organized mammography screening program among both screened and unscreened women: a population-based cohort study Breast Cancer Res 11 2009 R44
    • (2009) Breast Cancer Res , vol.11 , pp. 44
    • Kalager, M.1    Haldorsen, T.2    Bretthauer, M.3
  • 3
    • 0032004716 scopus 로고    scopus 로고
    • Estimating the accuracy of screening mammography: A meta-analysis
    • DOI 10.1016/S0749-3797(97)00019-6, PII S0749379797000196
    • A.I. Mushlin, R.W. Kouides, and D.E. Shapiro Estimating the accuracy of screening mammography: a meta-analysis Am J Prev Med 14 1998 143 153 (Pubitemid 28360950)
    • (1998) American Journal of Preventive Medicine , vol.14 , Issue.2 , pp. 143-153
    • Mushlin, A.I.1    Kouides, R.W.2    Shapiro, D.E.3
  • 4
    • 84868152438 scopus 로고    scopus 로고
    • Breast cancer mortality in mammographic screening in Europe: A review of incidence-based mortality studies
    • S. Njor, L. Nyström, and S. Moss et al. Breast cancer mortality in mammographic screening in Europe: a review of incidence-based mortality studies J Med Screen 19 suppl 1 2012 33 41
    • (2012) J Med Screen , vol.19 , Issue.SUPPL. 1 , pp. 33-41
    • Njor, S.1    Nyström, L.2    Moss, S.3
  • 6
    • 67651009480 scopus 로고    scopus 로고
    • The challenge of imaging dense breast parenchyma: Is magnetic resonance mammography the technique of choice? A comparative study with x-ray mammography and whole-breast ultrasound
    • F. Pediconi, C. Catalano, and A. Roselli et al. The challenge of imaging dense breast parenchyma: is magnetic resonance mammography the technique of choice? A comparative study with x-ray mammography and whole-breast ultrasound Invest Radiol 44 2009 412 421
    • (2009) Invest Radiol , vol.44 , pp. 412-421
    • Pediconi, F.1    Catalano, C.2    Roselli, A.3
  • 7
    • 84875421162 scopus 로고    scopus 로고
    • Unilateral breast cancer: Screening of contralateral breast by using preoperative MR imaging reduces incidence of metachronous cancer
    • J.Y. Kim, N. Cho, and H.R. Koo et al. Unilateral breast cancer: screening of contralateral breast by using preoperative MR imaging reduces incidence of metachronous cancer Radiology 267 2013 57 66
    • (2013) Radiology , vol.267 , pp. 57-66
    • Kim, J.Y.1    Cho, N.2    Koo, H.R.3
  • 8
    • 84874726114 scopus 로고    scopus 로고
    • Impact of presurgical breast magnetic resonance imaging (MRI) on surgical planning - A retrospective analysis from a private radiology group
    • X.C. Fan, T. Nemoto, and K. Blatto et al. Impact of presurgical breast magnetic resonance imaging (MRI) on surgical planning - a retrospective analysis from a private radiology group Breast J 19 2013 134 141
    • (2013) Breast J , vol.19 , pp. 134-141
    • Fan, X.C.1    Nemoto, T.2    Blatto, K.3
  • 9
    • 79551513576 scopus 로고    scopus 로고
    • Magnetic resonance mammography in small vs. Advanced breast lesions - Systematic comparison reveals significant impact of lesion size on diagnostic accuracy in 936 histologically verified breast lesions
    • M. Dietzel, P.A. Baltzer, and T. Vag et al. Magnetic resonance mammography in small vs. advanced breast lesions - systematic comparison reveals significant impact of lesion size on diagnostic accuracy in 936 histologically verified breast lesions Rofo 183 2011 126 135
    • (2011) Rofo , vol.183 , pp. 126-135
    • Dietzel, M.1    Baltzer, P.A.2    Vag, T.3
  • 10
    • 84858291324 scopus 로고    scopus 로고
    • Preoperative breast MRI in the surgical treatment of ductal carcinoma in situ
    • L.C. Kropcho, S.T. Steen, and A.P. Chung et al. Preoperative breast MRI in the surgical treatment of ductal carcinoma in situ Breast J 18 2012 151 156
    • (2012) Breast J , vol.18 , pp. 151-156
    • Kropcho, L.C.1    Steen, S.T.2    Chung, A.P.3
  • 11
    • 0031080698 scopus 로고    scopus 로고
    • Contrast-enhanced MRI of the breast: Accuracy, value, controversies, solutions
    • DOI 10.1016/S0720-048X(96)01142-4, PII S0720048X96011424
    • S.H. Heywang-Köbrunner, P. Viehweg, and A. Heinig et al. Contrast-enhanced MRI of the breast: accuracy, value, controversies, solutions Eur J Radiol 24 1997 94 108 (Pubitemid 27165349)
    • (1997) European Journal of Radiology , vol.24 , Issue.2 , pp. 94-108
    • Heywang-Kobrunner, S.H.1    Viehweg, P.2    Heinig, A.3    Kuchler, Ch.4
  • 12
    • 34547824534 scopus 로고    scopus 로고
    • F-18 Fluorodeoxyglucose-Positron Emission Tomography Imaging for Primary Breast Cancer and Loco-Regional Staging
    • DOI 10.1016/j.rcl.2007.05.004, PII S0033838907000565, Update on PET/CT Imaging
    • N. Avril, and L.P. Adler F-18 fluorodeoxyglucose-positron emission tomography imaging for primary breast cancer and loco-regional staging Radiol Clin North Am 45 2007 645 657 (Pubitemid 47238389)
    • (2007) Radiologic Clinics of North America , vol.45 , Issue.4 , pp. 645-657
    • Avril, N.1    Adler, L.P.2
  • 13
    • 84884742209 scopus 로고    scopus 로고
    • The current status of positron emission mammography in breast cancer diagnosis
    • V. Kalles, G.C. Zografos, and X. Provatopoulou et al. The current status of positron emission mammography in breast cancer diagnosis Breast Cancer 20 2013 123 130
    • (2013) Breast Cancer , vol.20 , pp. 123-130
    • Kalles, V.1    Zografos, G.C.2    Provatopoulou, X.3
  • 14
    • 33645499658 scopus 로고    scopus 로고
    • Evaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
    • P.F. Whiting, M.E. Weswood, and A.W. Rutjes et al. Evaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies BMC Med Res Methodol 6 2006 9
    • (2006) BMC Med Res Methodol , vol.6 , pp. 9
    • Whiting, P.F.1    Weswood, M.E.2    Rutjes, A.W.3
  • 15
    • 33747851721 scopus 로고    scopus 로고
    • Meta-DiSc: A software for meta-analysis of test accuracy data
    • J. Zamora, V. Abraira, and A. Muriel et al. Meta-DiSc: a software for meta-analysis of test accuracy data BMC Med Res Methodol 6 2006 31
    • (2006) BMC Med Res Methodol , vol.6 , pp. 31
    • Zamora, J.1    Abraira, V.2    Muriel, A.3
  • 16
    • 0033763260 scopus 로고    scopus 로고
    • Results of preliminary clinical trials of the positron emission mammography system PEM-I: A dedicated breast imaging system producing glucose metabolic images using FDG
    • K. Murthy, M. Aznar, and C.J. Thompson et al. Results of preliminary clinical trials of the positron emission mammography system PEM-I: a dedicated breast imaging system producing glucose metabolic images using FDG J Nucl Med 41 2000 1851 1858
    • (2000) J Nucl Med , vol.41 , pp. 1851-1858
    • Murthy, K.1    Aznar, M.2    Thompson, C.J.3
  • 17
    • 0037263417 scopus 로고    scopus 로고
    • Positron emission mammography: Initial clinical results
    • E.A. Levine, R.I. Freimanis, and N.D. Perrier et al. Positron emission mammography: initial clinical results Ann Surg Oncol 10 2003 86 91
    • (2003) Ann Surg Oncol , vol.10 , pp. 86-91
    • Levine, E.A.1    Freimanis, R.I.2    Perrier, N.D.3
  • 18
    • 12344265712 scopus 로고    scopus 로고
    • Detection of primary breast carcinoma with a dedicated, large-field-of-view FDG PET mammography device: Initial experience
    • DOI 10.1148/radiol.2342040654
    • E.L. Rosen, T.G. Turkington, and M.S. Soo et al. Detection of primary breast carcinoma with a dedicated, large-field-of-view FDG PET mammography device: initial experience Radiology 234 2005 527 534 (Pubitemid 40139925)
    • (2005) Radiology , vol.234 , Issue.2 , pp. 527-534
    • Rosen, E.L.1    Turkington, T.G.2    Soo, M.S.3    Baker, J.A.4    Coleman, R.E.5
  • 21
    • 78650607448 scopus 로고    scopus 로고
    • Breast cancer: Comparative effectiveness of positron emission mammography and MR imaging in presurgical planning for the ipsilateral breast
    • W.A. Berg, K.S. Madsen, and K. Schilling et al. Breast cancer: comparative effectiveness of positron emission mammography and MR imaging in presurgical planning for the ipsilateral breast Radiology 258 2011 59 72
    • (2011) Radiology , vol.258 , pp. 59-72
    • Berg, W.A.1    Madsen, K.S.2    Schilling, K.3
  • 22
    • 79551531671 scopus 로고    scopus 로고
    • Positron emission mammography in breast cancer presurgical planning: Comparisons with magnetic resonance imaging
    • K. Schilling, D. Narayanan, and J.E. Kalinyak et al. Positron emission mammography in breast cancer presurgical planning: comparisons with magnetic resonance imaging Eur J Nucl Med Mol Imaging 38 2011 23 36
    • (2011) Eur J Nucl Med Mol Imaging , vol.38 , pp. 23-36
    • Schilling, K.1    Narayanan, D.2    Kalinyak, J.E.3
  • 23
    • 84856328477 scopus 로고    scopus 로고
    • Imaging sensitivity of dedicated positron emission mammography in relation to tumor size
    • J.S. Eo, I.K. Chun, and J.C. Paeng et al. Imaging sensitivity of dedicated positron emission mammography in relation to tumor size Breast 21 2012 66 71
    • (2012) Breast , vol.21 , pp. 66-71
    • Eo, J.S.1    Chun, I.K.2    Paeng, J.C.3
  • 24
    • 77956869636 scopus 로고    scopus 로고
    • Positive predictive value of mammography: Comparison of interpretations of screening and diagnostic images by the same radiologist and by different radiologists
    • J.R. Halladay, B.C. Yankaskas, and J.M. Bowling et al. Positive predictive value of mammography: comparison of interpretations of screening and diagnostic images by the same radiologist and by different radiologists AJR Am J Roentgenol 195 2010 782 785
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 782-785
    • Halladay, J.R.1    Yankaskas, B.C.2    Bowling, J.M.3
  • 25
    • 0028805669 scopus 로고
    • Screening mammography in community practice: Positive predictive value of abnormal findings and yield of follow-up diagnostic procedures
    • M.L. Brown, F. Houn, and E.A. Sickles et al. Screening mammography in community practice: positive predictive value of abnormal findings and yield of follow-up diagnostic procedures AJR Am J Roentgenol 165 1995 1373 1377
    • (1995) AJR Am J Roentgenol , vol.165 , pp. 1373-1377
    • Brown, M.L.1    Houn, F.2    Sickles, E.A.3
  • 26
    • 0027279806 scopus 로고
    • Imaging of the radiographically dense breast
    • V.P. Jackson, R.E. Hendrick, and S.A. Feig et al. Imaging of the radiographically dense breast Radiology 188 1993 297 301 (Pubitemid 23216242)
    • (1993) Radiology , vol.188 , Issue.2 , pp. 297-301
    • Jackson, V.P.1    Hendrick, R.E.2    Feig, S.A.3    Kopans, D.B.4
  • 27
    • 84861624819 scopus 로고    scopus 로고
    • Should breast MRI be performed with adjustment for the phase in patients' menstrual cycle? Correlation between mammographic density, age, and background enhancement on breast MRI without adjusting for the phase in patients' menstrual cycle
    • T. Uematsu, M. Kasami, and J. Watanabe Should breast MRI be performed with adjustment for the phase in patients' menstrual cycle? Correlation between mammographic density, age, and background enhancement on breast MRI without adjusting for the phase in patients' menstrual cycle Eur J Radiol 81 2012 1539 1542
    • (2012) Eur J Radiol , vol.81 , pp. 1539-1542
    • Uematsu, T.1    Kasami, M.2    Watanabe, J.3
  • 28
    • 80053907592 scopus 로고    scopus 로고
    • Does the degree of background enhancement in breast MRI affect the detection and staging of breast cancer?
    • T. Uematsu, M. Kasami, and J. Watanabe Does the degree of background enhancement in breast MRI affect the detection and staging of breast cancer? Eur Radiol 21 2011 2261 2267
    • (2011) Eur Radiol , vol.21 , pp. 2261-2267
    • Uematsu, T.1    Kasami, M.2    Watanabe, J.3
  • 29
    • 1842610652 scopus 로고    scopus 로고
    • The size of metastatic foci and lymph nodes yielding false-negative and false-positive lymph node staging with positron emission tomography in patients with lung cancer
    • DOI 10.1016/j.jtcvs.2003.08.010
    • H. Nomori, K. Watanabe, and T. Ohtsuka et al. The size of metastatic foci and lymph nodes yielding false-negative and false-positive lymph node staging with positron emission tomography in patients with lung cancer J Thorac Cardiovasc Surg 127 2004 1087 1092 (Pubitemid 38451942)
    • (2004) Journal of Thoracic and Cardiovascular Surgery , vol.127 , Issue.4 , pp. 1087-1092
    • Nomori, H.1    Watanabe, K.2    Ohtsuka, T.3    Naruke, T.4    Suemasu, K.5    Uno, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.