-
1
-
-
0024469533
-
Retrospective cardiac gating: A review of technical aspects and future directions
-
DOI 10.1016/0730-725X(89)90399-8
-
Lenz GW, Haacke E, White RD,. Retrospective cardiac gating: a review of technical aspects and future directions. Magn Reson Med 1989; 7: 445-455. (Pubitemid 19247786)
-
(1989)
Magnetic Resonance Imaging
, vol.7
, Issue.5
, pp. 445-455
-
-
Lenz, G.W.1
Haacke, E.M.2
White, R.D.3
-
3
-
-
0023684480
-
Suppression of radiofrequency interference in cardiac gated MRI: A simple design
-
Shetty AN,. Suppression of radiofrequency interference in cardiac gated MRI: a simple design. Magn Reson Med 1988; 8: 84-88.
-
(1988)
Magn Reson Med
, vol.8
, pp. 84-88
-
-
Shetty, A.N.1
-
4
-
-
0025696493
-
Wireless retrospective gating: Application to cine cardiac imaging
-
Spraggins TA,. Wireless retrospective gating: application to cine cardiac imaging. Magn Reson Imaging 1990; 8: 675-681.
-
(1990)
Magn Reson Imaging
, vol.8
, pp. 675-681
-
-
Spraggins, T.A.1
-
5
-
-
4744352768
-
Automated rectilinear self-gated cardiac cine imaging
-
DOI 10.1002/mrm.20212
-
Crowe ME, Larson AC, Zhang Q, et al. Automated rectilinear self-gated cardiac cine imaging. Magn Reson Med 2004; 52: 782-788. (Pubitemid 39314980)
-
(2004)
Magnetic Resonance in Medicine
, vol.52
, Issue.4
, pp. 782-788
-
-
Crowe, M.E.1
Larson, A.C.2
Zhang, Q.3
Carr, J.4
White, R.D.5
Li, D.6
Simonetti, O.P.7
-
6
-
-
0346373771
-
Self-Gated Cardiac Cine MRI
-
DOI 10.1002/mrm.10664
-
Larson AC, White RD, Laub G, McVeigh ER, Li D, Simonetti OP,. Self-gated cardiac cine MRI. Magn Reson Med 2004; 51: 93-102. (Pubitemid 38095706)
-
(2004)
Magnetic Resonance in Medicine
, vol.51
, Issue.1
, pp. 93-102
-
-
Larson, A.C.1
White, R.D.2
Laub, G.3
McVeigh, E.R.4
Li, D.5
Simonetti, O.P.6
-
7
-
-
33847749977
-
Whole-heart cine MRI using real-time respiratory self-gating
-
DOI 10.1002/mrm.21156
-
Uribe S, Muthurangu V, Boubertakh R, et al. Whole-heart cine MRI using real-time respiratory self-gating. Magn Reson Med 2007; 57: 606-613. (Pubitemid 46385872)
-
(2007)
Magnetic Resonance in Medicine
, vol.57
, Issue.3
, pp. 606-613
-
-
Uribe, S.1
Muthurangu, V.2
Boubertakh, R.3
Schaeffter, T.4
Razavi, R.5
Hill, D.L.G.6
Hansen, M.S.7
-
8
-
-
51449086858
-
2D free-breathing dual navigator-gated cardiac function validated against the 2D breath-hold acquisition
-
Peters DC, Nezafat R, Eggers H, Stehning C, Manning WJ,. 2D free-breathing dual navigator-gated cardiac function validated against the 2D breath-hold acquisition. J Magn Reson Imaging 2008; 28: 773-777.
-
(2008)
J Magn Reson Imaging
, vol.28
, pp. 773-777
-
-
Peters, D.C.1
Nezafat, R.2
Eggers, H.3
Stehning, C.4
Manning, W.J.5
-
9
-
-
0030884045
-
Real-time interactive MRI on a conventional scanner
-
DOI 10.1002/mrm.1910380303
-
Kerr AB, Pauly JM, Hu BS, et al. Real-time interactive MRI on a conventional scanner. Magn Reson Med 1997; 38: 355-367. (Pubitemid 27386333)
-
(1997)
Magnetic Resonance in Medicine
, vol.38
, Issue.3
, pp. 355-367
-
-
Kerr, A.B.1
Pauly, J.M.2
Hu, B.S.3
Li, K.C.4
Hardy, C.J.5
Meyer, C.H.6
Macovski, A.7
Nishimura, D.G.8
-
10
-
-
78651498681
-
Real-time MRI at a resolution of 20 ms
-
Uecker M, Zhang S, Voit D, Karaus A, Merboldt KD, Frahm J,. Real-time MRI at a resolution of 20 ms. NMR Biodmed 2010; 23: 986-994.
-
(2010)
NMR Biodmed
, vol.23
, pp. 986-994
-
-
Uecker, M.1
Zhang, S.2
Voit, D.3
Karaus, A.4
Merboldt, K.D.5
Frahm, J.6
-
11
-
-
79251579662
-
Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging
-
Seiberlich N, Ehses P, Duerk J, Gilkeson R, Griswold M,. Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging. Magn Reson Med 2011; 65: 492-505.
-
(2011)
Magn Reson Med
, vol.65
, pp. 492-505
-
-
Seiberlich, N.1
Ehses, P.2
Duerk, J.3
Gilkeson, R.4
Griswold, M.5
-
12
-
-
77952692860
-
Nonlinear inverse reconstruction for real-time MRI of the human heart using undersampled radial FLASH
-
Uecker M, Zhang S, Frahm J,. Nonlinear inverse reconstruction for real-time MRI of the human heart using undersampled radial FLASH. Magn Reson Med 2010; 63: 1456-1462.
-
(2010)
Magn Reson Med
, vol.63
, pp. 1456-1462
-
-
Uecker, M.1
Zhang, S.2
Frahm, J.3
-
13
-
-
84904568988
-
Cardiac functional assessment without electrocardiogram using physiological self-navigation
-
[Epub ahead of print].
-
Kolbitsch C, Prieto C, Schaeffter T,. Cardiac functional assessment without electrocardiogram using physiological self-navigation. Magn Reson Med 2013. [Epub ahead of print].
-
(2013)
Magn Reson Med
-
-
Kolbitsch, C.1
Prieto, C.2
Schaeffter, T.3
-
14
-
-
84881188787
-
Motion corrected compressed sensing for free-breathing dynamic cardiac MRI
-
Usman M, Atkinson D, Odille F, et al. Motion corrected compressed sensing for free-breathing dynamic cardiac MRI. Magn Reson Med 2013; 70: 504-516.
-
(2013)
Magn Reson Med
, vol.70
, pp. 504-516
-
-
Usman, M.1
Atkinson, D.2
Odille, F.3
-
15
-
-
84865478167
-
Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction
-
Hansen MS, Sorensen TS, Arai AE, Kellman P,. Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction. Magn Reson Med 2012; 68: 741-750.
-
(2012)
Magn Reson Med
, vol.68
, pp. 741-750
-
-
Hansen, M.S.1
Sorensen, T.S.2
Arai, A.E.3
Kellman, P.4
-
16
-
-
0027093023
-
Projection reconstruction techniques for reduction of motion effects in MRI
-
DOI 10.1002/mrm.1910280209
-
Glover GH, Pauly JM,. Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med 1992; 28: 275-289. (Pubitemid 23027667)
-
(1992)
Magnetic Resonance in Medicine
, vol.28
, Issue.2
, pp. 275-289
-
-
Glover, G.H.1
Pauly, J.M.2
-
17
-
-
0033971791
-
Undersampled projection reconstruction applied to MR angiography
-
DOI 10.1002/(SICI)1522-2594(200001)43: 1<91:: AID-MRM11>3.0.CO;2-4
-
Peters DC, Korosec FR, Grist TM, et al. Undersampled projection reconstruction applied to MR angiography. Magn Reson Med 2000; 43: 91-101. (Pubitemid 30027116)
-
(2000)
Magnetic Resonance in Medicine
, vol.43
, Issue.1
, pp. 91-101
-
-
Peters, D.C.1
Korosec, F.R.2
Grist, T.M.3
Block, W.F.4
Holden, J.E.5
Vigen, K.K.6
Mistretta, C.A.7
-
18
-
-
32544437989
-
Characterizing radial undersampling artifacts for cardiac applications
-
DOI 10.1002/mrm.20782
-
Peters DC, Rohatgi P, Botnar RM, Yeon SB, Kissinger KV, Manning WJ,. Characterizing radial undersampling artifacts for cardiac applications. Magn Reson Med 2006; 55: 396-403. (Pubitemid 43238109)
-
(2006)
Magnetic Resonance in Medicine
, vol.55
, Issue.2
, pp. 396-403
-
-
Peters, D.C.1
Rohatgi, P.2
Botnar, R.M.3
Yeon, S.B.4
Kissinger, K.V.5
Manning, W.J.6
-
19
-
-
0023740742
-
MR fluoroscopy: Technical feasibility
-
Riederer SJ, Tasciyan T, Farzaneh F, Lee JN, Wright RC, Herfkens RJ,. MR fluoroscopy: technical feasibility. Magn Reson Med 1988; 8: 1-15.
-
(1988)
Magn Reson Med
, vol.8
, pp. 1-15
-
-
Riederer, S.J.1
Tasciyan, T.2
Farzaneh, F.3
Lee, J.N.4
Wright, R.C.5
Herfkens, R.J.6
-
20
-
-
33846246695
-
An optimal radial profile order based on the golden ratio for time-resolved MRI
-
DOI 10.1109/TMI.2006.885337
-
Winkelmann S, Schaeffter T, Koehler T, Eggers H, Doessel O,. An optimal radial profile order based on the golden ratio for time-resolved MRI. IEEE Trans Med Imaging 2007; 26: 68-76. (Pubitemid 46096351)
-
(2007)
IEEE Transactions on Medical Imaging
, vol.26
, Issue.1
, pp. 68-76
-
-
Winkelmann, S.1
Schaeffter, T.2
Koehler, T.3
Eggers, H.4
Doessel, O.5
-
21
-
-
46149135128
-
FLASH imaging. Rapid NMR imaging using low flip-angle pulses
-
Haase A, Frahm J, Matthaei D, Hanicke W, Merboldt KD,. FLASH imaging. Rapid NMR imaging using low flip-angle pulses. J Magn Reson 1986; 67: 258-266.
-
(1986)
J Magn Reson
, vol.67
, pp. 258-266
-
-
Haase, A.1
Frahm, J.2
Matthaei, D.3
Hanicke, W.4
Merboldt, K.D.5
-
22
-
-
4243179125
-
ODIN - Object-oriented development interface for NMR
-
Jochimsen TH, von Mengershausen M,. ODIN-object-oriented development interface for NMR. J Magn Reson 2004; 170: 67-78.
-
(2004)
J Magn Reson
, vol.170
, pp. 67-78
-
-
Jochimsen, T.H.1
Von Mengershausen, M.2
-
23
-
-
84857358528
-
Efficient sample density estimation by combining gridding and an optimized kernel
-
Zwart NR, Johnson KO, Pipe JG,. Efficient sample density estimation by combining gridding and an optimized kernel. Magn Reson Med 2012; 67: 701-710.
-
(2012)
Magn Reson Med
, vol.67
, pp. 701-710
-
-
Zwart, N.R.1
Johnson, K.O.2
Pipe, J.G.3
-
24
-
-
84858708733
-
Comparison of retrospectively self-gated and prospectively triggered FLASH sequences for cine imaging of the aorta in mice at 9.4 Tesla
-
Fries P, Mamann A, Seidel R, et al. Comparison of retrospectively self-gated and prospectively triggered FLASH sequences for cine imaging of the aorta in mice at 9.4 Tesla. Invest Radiol 2012; 47: 259-266.
-
(2012)
Invest Radiol
, vol.47
, pp. 259-266
-
-
Fries, P.1
Mamann, A.2
Seidel, R.3
-
25
-
-
84870066487
-
Free-breathing cardiac MR with a fixed navigator efficiency using adaptive gating window size
-
Moghari MH, Chan RH, Hong SN, et al. Free-breathing cardiac MR with a fixed navigator efficiency using adaptive gating window size. Magn Reson Med 2012; 68: 1866-1875.
-
(2012)
Magn Reson Med
, vol.68
, pp. 1866-1875
-
-
Moghari, M.H.1
Chan, R.H.2
Hong, S.N.3
-
26
-
-
0032701253
-
Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography
-
Stuber M, Botnar RM, Danias PG, et al. Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography. J Am Coll Cardiol 1999; 34: 524-531.
-
(1999)
J Am Coll Cardiol
, vol.34
, pp. 524-531
-
-
Stuber, M.1
Botnar, R.M.2
Danias, P.G.3
-
27
-
-
84904573803
-
Three-dimensional heart locator for whole-heart coronary magnetic resonance angiography
-
[Epub ahead of print].
-
Moghari MH, Roujol S, Henningsson M, et al. Three-dimensional heart locator for whole-heart coronary magnetic resonance angiography. Magn Reson Med 2013. [Epub ahead of print].
-
(2013)
Magn Reson Med
-
-
Moghari, M.H.1
Roujol, S.2
Henningsson, M.3
-
28
-
-
36849088522
-
Sparse MRI: The application of compressed sensing for rapid MR imaging
-
DOI 10.1002/mrm.21391
-
Lustig M, Donoho D, Pauly JM,. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182-1195. (Pubitemid 350234205)
-
(2007)
Magnetic Resonance in Medicine
, vol.58
, Issue.6
, pp. 1182-1195
-
-
Lustig, M.1
Donoho, D.2
Pauly, J.M.3
-
29
-
-
80054774301
-
Accelerating cine-MR imaging in mouse hearts using compressed sensing
-
Wech T, Lemke A, Medway D, et al. Accelerating cine-MR imaging in mouse hearts using compressed sensing. J Magn Reson Imaging 2011; 34: 1072-1079.
-
(2011)
J Magn Reson Imaging
, vol.34
, pp. 1072-1079
-
-
Wech, T.1
Lemke, A.2
Medway, D.3
-
30
-
-
84856277712
-
Free-breathing imaging of the heart using 2D cine-GRICS (generalized reconstruction by inversion of coupled systems) with assessment of ventricular volumes and function
-
Vuissoz PA, Odille F, Fernandez B, et al. Free-breathing imaging of the heart using 2D cine-GRICS (generalized reconstruction by inversion of coupled systems) with assessment of ventricular volumes and function. J Magn Reson Imaging 2012; 35: 340-351.
-
(2012)
J Magn Reson Imaging
, vol.35
, pp. 340-351
-
-
Vuissoz, P.A.1
Odille, F.2
Fernandez, B.3
-
31
-
-
79959621699
-
New respiratory gating technique for whole heart cine imaging: Integration of a navigator slice in steady state free precession sequences
-
Uribe S, Tejos C, Razavi R, Schaeffter T,. New respiratory gating technique for whole heart cine imaging: integration of a navigator slice in steady state free precession sequences. J Magn Reson Imaging 2011; 34: 211-219.
-
(2011)
J Magn Reson Imaging
, vol.34
, pp. 211-219
-
-
Uribe, S.1
Tejos, C.2
Razavi, R.3
Schaeffter, T.4
|