메뉴 건너뛰기




Volumn 40, Issue 2, 2014, Pages 413-422

Retrospective reconstruction of cardiac cine images from golden-ratio radial MRI using one-dimensional navigators

Author keywords

cardiac cine imaging; projection reconstruction; radial acquisition; real time imaging

Indexed keywords

ADULT; ARTICLE; ARTIFACT; BREATH HOLDING; CARDIOVASCULAR MAGNETIC RESONANCE; CONTRAST TO NOISE RATIO; CORRELATION ANALYSIS; ELECTROCARDIOGRAPHY; GOLDEN RATIO RADIAL CARDIAC CINE NUCLEAR MAGNETIC RESONANCE IMAGING; HEART LEFT VENTRICLE; HEART MOVEMENT; HEART MUSCLE; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; NORMAL HUMAN; PRIORITY JOURNAL; RETROSPECTIVE IMAGE RECONSTRUCTION; SIGNAL NOISE RATIO; WHOLE BODY SCANNER; ALGORITHM; ANATOMY AND HISTOLOGY; AUTOMATED PATTERN RECOGNITION; COMPUTER ASSISTED DIAGNOSIS; FEMALE; HEART; IMAGE ENHANCEMENT; IMAGE SUBTRACTION; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PROCEDURES; REPRODUCIBILITY; RETROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY;

EID: 84904556126     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.24364     Document Type: Article
Times cited : (21)

References (31)
  • 1
    • 0024469533 scopus 로고
    • Retrospective cardiac gating: A review of technical aspects and future directions
    • DOI 10.1016/0730-725X(89)90399-8
    • Lenz GW, Haacke E, White RD,. Retrospective cardiac gating: a review of technical aspects and future directions. Magn Reson Med 1989; 7: 445-455. (Pubitemid 19247786)
    • (1989) Magnetic Resonance Imaging , vol.7 , Issue.5 , pp. 445-455
    • Lenz, G.W.1    Haacke, E.M.2    White, R.D.3
  • 3
    • 0023684480 scopus 로고
    • Suppression of radiofrequency interference in cardiac gated MRI: A simple design
    • Shetty AN,. Suppression of radiofrequency interference in cardiac gated MRI: a simple design. Magn Reson Med 1988; 8: 84-88.
    • (1988) Magn Reson Med , vol.8 , pp. 84-88
    • Shetty, A.N.1
  • 4
    • 0025696493 scopus 로고
    • Wireless retrospective gating: Application to cine cardiac imaging
    • Spraggins TA,. Wireless retrospective gating: application to cine cardiac imaging. Magn Reson Imaging 1990; 8: 675-681.
    • (1990) Magn Reson Imaging , vol.8 , pp. 675-681
    • Spraggins, T.A.1
  • 8
    • 51449086858 scopus 로고    scopus 로고
    • 2D free-breathing dual navigator-gated cardiac function validated against the 2D breath-hold acquisition
    • Peters DC, Nezafat R, Eggers H, Stehning C, Manning WJ,. 2D free-breathing dual navigator-gated cardiac function validated against the 2D breath-hold acquisition. J Magn Reson Imaging 2008; 28: 773-777.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 773-777
    • Peters, D.C.1    Nezafat, R.2    Eggers, H.3    Stehning, C.4    Manning, W.J.5
  • 11
    • 79251579662 scopus 로고    scopus 로고
    • Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging
    • Seiberlich N, Ehses P, Duerk J, Gilkeson R, Griswold M,. Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging. Magn Reson Med 2011; 65: 492-505.
    • (2011) Magn Reson Med , vol.65 , pp. 492-505
    • Seiberlich, N.1    Ehses, P.2    Duerk, J.3    Gilkeson, R.4    Griswold, M.5
  • 12
    • 77952692860 scopus 로고    scopus 로고
    • Nonlinear inverse reconstruction for real-time MRI of the human heart using undersampled radial FLASH
    • Uecker M, Zhang S, Frahm J,. Nonlinear inverse reconstruction for real-time MRI of the human heart using undersampled radial FLASH. Magn Reson Med 2010; 63: 1456-1462.
    • (2010) Magn Reson Med , vol.63 , pp. 1456-1462
    • Uecker, M.1    Zhang, S.2    Frahm, J.3
  • 13
    • 84904568988 scopus 로고    scopus 로고
    • Cardiac functional assessment without electrocardiogram using physiological self-navigation
    • [Epub ahead of print].
    • Kolbitsch C, Prieto C, Schaeffter T,. Cardiac functional assessment without electrocardiogram using physiological self-navigation. Magn Reson Med 2013. [Epub ahead of print].
    • (2013) Magn Reson Med
    • Kolbitsch, C.1    Prieto, C.2    Schaeffter, T.3
  • 14
    • 84881188787 scopus 로고    scopus 로고
    • Motion corrected compressed sensing for free-breathing dynamic cardiac MRI
    • Usman M, Atkinson D, Odille F, et al. Motion corrected compressed sensing for free-breathing dynamic cardiac MRI. Magn Reson Med 2013; 70: 504-516.
    • (2013) Magn Reson Med , vol.70 , pp. 504-516
    • Usman, M.1    Atkinson, D.2    Odille, F.3
  • 15
    • 84865478167 scopus 로고    scopus 로고
    • Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction
    • Hansen MS, Sorensen TS, Arai AE, Kellman P,. Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction. Magn Reson Med 2012; 68: 741-750.
    • (2012) Magn Reson Med , vol.68 , pp. 741-750
    • Hansen, M.S.1    Sorensen, T.S.2    Arai, A.E.3    Kellman, P.4
  • 16
    • 0027093023 scopus 로고
    • Projection reconstruction techniques for reduction of motion effects in MRI
    • DOI 10.1002/mrm.1910280209
    • Glover GH, Pauly JM,. Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med 1992; 28: 275-289. (Pubitemid 23027667)
    • (1992) Magnetic Resonance in Medicine , vol.28 , Issue.2 , pp. 275-289
    • Glover, G.H.1    Pauly, J.M.2
  • 22
    • 4243179125 scopus 로고    scopus 로고
    • ODIN - Object-oriented development interface for NMR
    • Jochimsen TH, von Mengershausen M,. ODIN-object-oriented development interface for NMR. J Magn Reson 2004; 170: 67-78.
    • (2004) J Magn Reson , vol.170 , pp. 67-78
    • Jochimsen, T.H.1    Von Mengershausen, M.2
  • 23
    • 84857358528 scopus 로고    scopus 로고
    • Efficient sample density estimation by combining gridding and an optimized kernel
    • Zwart NR, Johnson KO, Pipe JG,. Efficient sample density estimation by combining gridding and an optimized kernel. Magn Reson Med 2012; 67: 701-710.
    • (2012) Magn Reson Med , vol.67 , pp. 701-710
    • Zwart, N.R.1    Johnson, K.O.2    Pipe, J.G.3
  • 24
    • 84858708733 scopus 로고    scopus 로고
    • Comparison of retrospectively self-gated and prospectively triggered FLASH sequences for cine imaging of the aorta in mice at 9.4 Tesla
    • Fries P, Mamann A, Seidel R, et al. Comparison of retrospectively self-gated and prospectively triggered FLASH sequences for cine imaging of the aorta in mice at 9.4 Tesla. Invest Radiol 2012; 47: 259-266.
    • (2012) Invest Radiol , vol.47 , pp. 259-266
    • Fries, P.1    Mamann, A.2    Seidel, R.3
  • 25
    • 84870066487 scopus 로고    scopus 로고
    • Free-breathing cardiac MR with a fixed navigator efficiency using adaptive gating window size
    • Moghari MH, Chan RH, Hong SN, et al. Free-breathing cardiac MR with a fixed navigator efficiency using adaptive gating window size. Magn Reson Med 2012; 68: 1866-1875.
    • (2012) Magn Reson Med , vol.68 , pp. 1866-1875
    • Moghari, M.H.1    Chan, R.H.2    Hong, S.N.3
  • 26
    • 0032701253 scopus 로고    scopus 로고
    • Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography
    • Stuber M, Botnar RM, Danias PG, et al. Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography. J Am Coll Cardiol 1999; 34: 524-531.
    • (1999) J Am Coll Cardiol , vol.34 , pp. 524-531
    • Stuber, M.1    Botnar, R.M.2    Danias, P.G.3
  • 27
    • 84904573803 scopus 로고    scopus 로고
    • Three-dimensional heart locator for whole-heart coronary magnetic resonance angiography
    • [Epub ahead of print].
    • Moghari MH, Roujol S, Henningsson M, et al. Three-dimensional heart locator for whole-heart coronary magnetic resonance angiography. Magn Reson Med 2013. [Epub ahead of print].
    • (2013) Magn Reson Med
    • Moghari, M.H.1    Roujol, S.2    Henningsson, M.3
  • 28
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • DOI 10.1002/mrm.21391
    • Lustig M, Donoho D, Pauly JM,. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182-1195. (Pubitemid 350234205)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.6 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 29
    • 80054774301 scopus 로고    scopus 로고
    • Accelerating cine-MR imaging in mouse hearts using compressed sensing
    • Wech T, Lemke A, Medway D, et al. Accelerating cine-MR imaging in mouse hearts using compressed sensing. J Magn Reson Imaging 2011; 34: 1072-1079.
    • (2011) J Magn Reson Imaging , vol.34 , pp. 1072-1079
    • Wech, T.1    Lemke, A.2    Medway, D.3
  • 30
    • 84856277712 scopus 로고    scopus 로고
    • Free-breathing imaging of the heart using 2D cine-GRICS (generalized reconstruction by inversion of coupled systems) with assessment of ventricular volumes and function
    • Vuissoz PA, Odille F, Fernandez B, et al. Free-breathing imaging of the heart using 2D cine-GRICS (generalized reconstruction by inversion of coupled systems) with assessment of ventricular volumes and function. J Magn Reson Imaging 2012; 35: 340-351.
    • (2012) J Magn Reson Imaging , vol.35 , pp. 340-351
    • Vuissoz, P.A.1    Odille, F.2    Fernandez, B.3
  • 31
    • 79959621699 scopus 로고    scopus 로고
    • New respiratory gating technique for whole heart cine imaging: Integration of a navigator slice in steady state free precession sequences
    • Uribe S, Tejos C, Razavi R, Schaeffter T,. New respiratory gating technique for whole heart cine imaging: integration of a navigator slice in steady state free precession sequences. J Magn Reson Imaging 2011; 34: 211-219.
    • (2011) J Magn Reson Imaging , vol.34 , pp. 211-219
    • Uribe, S.1    Tejos, C.2    Razavi, R.3    Schaeffter, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.