메뉴 건너뛰기




Volumn 38, Issue 6, 2014, Pages 1125-1129

A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess wether a dual mobility cup has a decreased dislocation risk

Author keywords

Arthroplasty replacement hip; Charnley total hip arthroplasty; Dislocation; Dual mobility cup; Joint instability prevention and control; Prosthesis design

Indexed keywords

ACETABULUM PROSTHESIS; ADULT; AGED; ARTICLE; COMPARATIVE EFFECTIVENESS; COMPARATIVE STUDY; DUAL MOBILITY CUP; FEMALE; FOLLOW UP; FRACTURE REDUCTION; HIP DISLOCATION; HIP PROSTHESIS DISLOCATION; HUMAN; MAJOR CLINICAL STUDY; MALE; OUTCOME ASSESSMENT; POLYETHYLENE CUP; PRIORITY JOURNAL; PROSTHESIS FAILURE; PROSTHESIS LOOSENING; RANGE OF MOTION; RECURRENT DISLOCATION; REOPERATION; RETROSPECTIVE STUDY; RISK REDUCTION; TOTAL HIP PROSTHESIS; VERY ELDERLY; CEMENTATION; DEVICES; HIP; HIP ARTHROPLASTY; HIP PROSTHESIS; JOINT DISEASES; MIDDLE AGED;

EID: 84904540258     PISSN: 03412695     EISSN: 14325195     Source Type: Journal    
DOI: 10.1007/s00264-014-2313-2     Document Type: Article
Times cited : (109)

References (22)
  • 1
    • 79955937198 scopus 로고    scopus 로고
    • Over 25 years survival after Charnley's total hip arthroplasty
    • Caton J, Prudhon JL (2011) Over 25 years survival after Charnley's total hip arthroplasty. Int Orthop 35:185-188
    • (2011) Int Orthop , vol.35 , pp. 185-188
    • Caton, J.1    Prudhon, J.L.2
  • 2
    • 85014800677 scopus 로고    scopus 로고
    • Hip dislocation and outcome
    • MCI France (ed) Lyon
    • Caton J, Merabet Z (2004) Hip dislocation and outcome. In: MCI France (ed) La prothèse totale de hanche, pp 223-227. Lyon
    • (2004) La Prothèse Totale de Hanche , pp. 223-227
    • Caton, J.1    Merabet, Z.2
  • 5
    • 84890442910 scopus 로고    scopus 로고
    • What are the causes for failures of primary hip arthroplasties in France?
    • SoFCOT Group
    • Delaunay C, Hamadouche M, Girard J, Duhamel A, SoFCOT Group (2013) What are the causes for failures of primary hip arthroplasties in France? Clin Orthop Relat Res 471:3863-3869
    • (2013) Clin Orthop Relat Res , vol.471 , pp. 3863-3869
    • Delaunay, C.1    Hamadouche, M.2    Girard, J.3    Duhamel, A.4
  • 6
    • 0027754673 scopus 로고
    • Study of Bousquet's noncemented acetabular implant in 100 hybrid total hip prostheses (Charnley type cemented femoral component). Average 5-year follow-up
    • Aubriot JH, Lesimple P, Leclercq S (1993) Study of Bousquet's noncemented acetabular implant in 100 hybrid total hip prostheses (Charnley type cemented femoral component). Average 5-year follow-up. Acta Orthop Belg 59(Suppl 1):267-271
    • (1993) Acta Orthop Belg , vol.59 , Issue.SUPPL. 1 , pp. 267-271
    • Aubriot, J.H.1    Lesimple, P.2    Leclercq, S.3
  • 8
    • 84890566301 scopus 로고    scopus 로고
    • Dual mobility cup: Dislocation rate and survivorship at ten years of follow-up
    • Prudhon JL, Ferreira A, Verdier R (2013) Dual mobility cup: dislocation rate and survivorship at ten years of follow-up. Int Orthop 37:2345-2350
    • (2013) Int Orthop , vol.37 , pp. 2345-2350
    • Prudhon, J.L.1    Ferreira, A.2    Verdier, R.3
  • 9
    • 77049159486 scopus 로고
    • Functional results of hip arthroplasty with acrylic prosthesis
    • D'Aubigne RM, Postel M (1954) Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am 36:451-475
    • (1954) J Bone Joint Surg Am , vol.36 , pp. 451-475
    • D'Aubigne, R.M.1    Postel, M.2
  • 10
    • 0031544132 scopus 로고    scopus 로고
    • Three-dimensional polyethylene wear of a press-fit titanium prosthesis: Factors influencing generation of polyethylene debris
    • DOI 10.1016/S0883-5403(97)90021-8
    • Devane PA, Horne JG, Martin K, Coldham G, Krause B (1997) Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris. J Arthroplasty 12:256-266 (Pubitemid 29021325)
    • (1997) Journal of Arthroplasty , vol.12 , Issue.3 , pp. 256-266
    • Devane, P.A.1    Horne, J.G.2    Martin, K.3    Coldham, G.4    Krause, B.5
  • 11
    • 0032833192 scopus 로고    scopus 로고
    • Risk factors for dislocation during the first 3 months after primary total hip replacement
    • DOI 10.1016/S0883-5403(99)90219-X
    • Woolson ST, Rahimtoola ZO (1999) Risk factors for dislocation during the first 3 months after primary total hip replacement. J Arthroplasty 14:662-668 (Pubitemid 29448779)
    • (1999) Journal of Arthroplasty , vol.14 , Issue.6 , pp. 662-668
    • Woolson, S.T.1    Rahimtoola, Z.O.2
  • 12
    • 80755135505 scopus 로고    scopus 로고
    • Cup size and risk of dislocation after primary total hip arthroplasty
    • Peter R, Lübbeke A, Stern R, Hoffmeyer P (2011) Cup size and risk of dislocation after primary total hip arthroplasty. J Arthroplasty 26: 1305-1309
    • (2011) J Arthroplasty , vol.26 , pp. 1305-1309
    • Peter, R.1    Lübbeke, A.2    Stern, R.3    Hoffmeyer, P.4
  • 13
    • 34548432931 scopus 로고    scopus 로고
    • Unconstrained Tripolar Implants for Primary Total Hip Arthroplasty in Patients at Risk for Dislocation
    • DOI 10.1016/j.arth.2006.11.014, PII S0883540306008291
    • Guyen O, Pibarot V, Vaz G, Chevillotte C, Carret JP, Bejui-Hugues J (2007) Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation. J Arthroplasty 22: 849-858 (Pubitemid 47361663)
    • (2007) Journal of Arthroplasty , vol.22 , Issue.6 , pp. 849-858
    • Guyen, O.1    Pibarot, V.2    Vaz, G.3    Chevillotte, C.4    Carret, J.-P.5    Bejui-Hugues, J.6
  • 17
    • 68349086967 scopus 로고    scopus 로고
    • The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: Analysis of 384 cases at a mean follow-up of 15 years
    • Philippot R, Camilleri JP, Boyer B, Adam P, Farizon F (2009) The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years. Int Orthop 33:927-932
    • (2009) Int Orthop , vol.33 , pp. 927-932
    • Philippot, R.1    Camilleri, J.P.2    Boyer, B.3    Adam, P.4    Farizon, F.5
  • 19
  • 20
    • 84865979786 scopus 로고    scopus 로고
    • The use of dual-mobility components in total hip arthroplasty
    • Lachiewicz PF, Watters TS (2012) The use of dual-mobility components in total hip arthroplasty. J Am Acad Orthop Surg 20: 481-486
    • (2012) J Am Acad Orthop Surg , vol.20 , pp. 481-486
    • Lachiewicz, P.F.1    Watters, T.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.