메뉴 건너뛰기




Volumn 7, Issue , 2014, Pages 183-207

Light-emitting diodes for analytical chemistry

Author keywords

Absorbance detection; Capillary separations; Fluorescence detection; Microfluidic chip; Optical methods of analysis; Sensors

Indexed keywords

ANALYTICAL GEOCHEMISTRY; CHEMISTRY; SENSORS;

EID: 84904335158     PISSN: 19361327     EISSN: 19361335     Source Type: Book Series    
DOI: 10.1146/annurev-anchem-071213-020059     Document Type: Review
Times cited : (111)

References (178)
  • 1
    • 84904359201 scopus 로고    scopus 로고
    • Going deep for UV sterilization LEDs
    • Cooke M. 2010. Going deep for UV sterilization LEDs. Semicond. Today 5(3):82-88
    • (2010) Semicond. Today , vol.5 , Issue.3 , pp. 82-88
    • Cooke, M.1
  • 2
    • 84870899551 scopus 로고    scopus 로고
    • Optimization of solid-state lamps for photobiologically friendly mesopic lighting
    • Zukauskas A, Vaicekauskas R, Vitta P. 2012. Optimization of solid-state lamps for photobiologically friendly mesopic lighting. Appl. Opt. 51:8423-32
    • (2012) Appl. Opt. , vol.51 , pp. 8423-8432
    • Zukauskas, A.1    Vaicekauskas, R.2    Vitta, P.3
  • 3
    • 78449251157 scopus 로고    scopus 로고
    • White LEDs as broad spectrum light sources for spectrophotometry: Demonstration in the visible spectrum range in a diode-array spectrophotometric detector
    • Piasecki T, Breadmore MC, Macka M. 2010. White LEDs as broad spectrum light sources for spectrophotometry: demonstration in the visible spectrum range in a diode-array spectrophotometric detector. Electrophoresis 31:3737-44
    • (2010) Electrophoresis , vol.31 , pp. 3737-3744
    • Piasecki, T.1    Breadmore, M.C.2    Macka, M.3
  • 5
    • 84867347699 scopus 로고    scopus 로고
    • 50 years ago: HowHolonyak won the race to invent visible LEDs
    • PaluckaT. 2012. 50 years ago: HowHolonyak won the race to invent visible LEDs. MRS Bull. 37:963-66
    • (2012) MRS Bull. , vol.37 , pp. 963-966
    • Palucka, T.1
  • 6
    • 0042099114 scopus 로고    scopus 로고
    • Cambridge, UK: Cambridge Univ. Press
    • Schubert EF. 2006. Light-Emitting Diodes. Cambridge, UK: Cambridge Univ. Press. 431 pp.
    • (2006) Light-Emitting Diodes , pp. 431
    • Schubert, E.F.1
  • 8
    • 0001935021 scopus 로고
    • Light emitting diode based flowthrough optical absorption detectors
    • Dasgupta PK, Bellamy HS, Liu H, Lopez JL, Loree EL, et al. 1993. Light emitting diode based flowthrough optical absorption detectors. Talanta 40:53-74
    • (1993) Talanta , vol.40 , pp. 53-74
    • Dasgupta, P.K.1    Bellamy, H.S.2    Liu, H.3    Lopez, J.L.4    Loree, E.L.5
  • 9
    • 0344413684 scopus 로고    scopus 로고
    • Light emitting diode-based detectors: Absorbance, fluorescence and spectroelectrochemical measurements in a planar flow-through cell
    • DOI 10.1016/S0003-2670(03)00575-0
    • Dasgupta PK, Eom IY, Morris KJ, Li J. 2003. Light emitting diode-based detectors: absorbance, fluorescence and spectroelectrochemical measurements in a planar flow-through cell. Anal. Chim. Acta 500:337-64 (Pubitemid 37487790)
    • (2003) Analytica Chimica Acta , vol.500 , Issue.1-2 , pp. 337-364
    • Dasgupta, P.K.1    Eom, I.-Y.2    Morris, K.J.3    Li, J.4
  • 10
    • 0035450435 scopus 로고    scopus 로고
    • Application of semiconductor light sources for investigations of photochemical reactions
    • Landgraf S. 2001. Application of semiconductor light sources for investigations of photochemical reactions. Spectrochim. Acta A 57:2029-48
    • (2001) Spectrochim. Acta A , vol.57 , pp. 2029-2048
    • Landgraf, S.1
  • 11
    • 9344266550 scopus 로고    scopus 로고
    • Application of laser diodes and ultrabright light emitting diodes for static and time resolved optical methods in physical chemistry
    • ed. HS Nalwa, LS Rohwer Stevenson Ranch, CA: Am. Sci. Publ.
    • Landgraf S. 2003. Application of laser diodes and ultrabright light emitting diodes for static and time resolved optical methods in physical chemistry. In Handbook of Luminescence, Display Materials and Devices, Vol. 3, ed. HS Nalwa, LS Rohwer, pp. 371-98. Stevenson Ranch, CA: Am. Sci. Publ.
    • (2003) Handbook of Luminescence, Display Materials and Devices , vol.3 , pp. 371-398
    • Landgraf, S.1
  • 12
    • 84904341344 scopus 로고    scopus 로고
    • Semiconductor lights sources in modulation fluorometry using digital storage oscilloscopes
    • ed CD Geddes, JR Lakowicz New York: Kluwer Acad./ Plenum
    • Landgraf S. 2004. Semiconductor lights sources in modulation fluorometry using digital storage oscilloscopes. In Reviews in Fluorescence 2004, ed. CD Geddes, JR Lakowicz, pp. 341-63. New York: Kluwer Acad./Plenum
    • (2004) Reviews in Fluorescence 2004 , pp. 341-363
    • Landgraf, S.1
  • 13
    • 33845674687 scopus 로고    scopus 로고
    • Recent developments in optical detection methods for microchip separations
    • DOI 10.1007/s00216-006-0820-8
    • G otz S, Karst U. 2007. Recent developments in optical detection methods for microchip separations. Anal. Bioanal. Chem. 387:183-92 (Pubitemid 44956271)
    • (2007) Analytical and Bioanalytical Chemistry , vol.387 , Issue.1 , pp. 183-192
    • Gotz, S.1    Karst, U.2
  • 15
    • 33846616370 scopus 로고    scopus 로고
    • CE detector based on light-emitting diodes
    • DOI 10.1002/elps.200600473
    • Xiao D, Zhao SL, Yuan HY, Yang XP. 2007. CE detector based on light-emitting diodes. Electrophoresis 28:233-42 (Pubitemid 46178962)
    • (2007) Electrophoresis , vol.28 , Issue.1-2 , pp. 233-242
    • Xiao, D.1    Zhao, S.2    Yuan, H.3    Yang, X.4
  • 16
    • 84863000713 scopus 로고    scopus 로고
    • A comparative study of LED-induced fluorescence and laser-induced fluorescence in SDS-CGE: Application to the analysis of antibodies
    • Rodat-Boutonnet A, Naccache P, Morin A, Fabre J, Feurer B, Couderc F. 2012. A comparative study of LED-induced fluorescence and laser-induced fluorescence in SDS-CGE: application to the analysis of antibodies. Electrophoresis 33:1709-14
    • (2012) Electrophoresis , vol.33 , pp. 1709-1714
    • Rodat-Boutonnet, A.1    Naccache, P.2    Morin, A.3    Fabre, J.4    Feurer, B.5    Couderc, F.6
  • 18
    • 84932435168 scopus 로고
    • Laser beams and resonators
    • Kogelnik H, Li T. 1966. Laser beams and resonators. Appl. Opt. 5:1550-67
    • (1966) Appl. Opt. , vol.5 , pp. 1550-1567
    • Kogelnik, H.1    Li, T.2
  • 21
    • 13144294081 scopus 로고    scopus 로고
    • Wavelength demodulation of ultrabright green light-emitting diodes for electrical current sensing
    • DOI 10.1109/JSEN.2004.838663
    • Ribeiro RM, Martins L, Werneck MM. 2005. Wavelength demodulation of ultrabright green lightemitting diodes for electrical current sensing. IEEE 5:38-47 (Pubitemid 40178483)
    • (2005) IEEE Sensors Journal , vol.5 , Issue.1 , pp. 38-47
    • Ribeiro, R.M.1    Martins, L.2    Werneck, M.M.3
  • 22
    • 0032830101 scopus 로고    scopus 로고
    • Optical fiber coupled light emitting diode based absorbance detector with a reflective flow cell
    • Jambunathan S, Dasgupta PK, Wolcott DK, Marshall GD, Olson DC. 1999. Optical fiber coupled light emitting diode based absorbance detector with a reflective flow cell. Talanta 50:481-90
    • (1999) Talanta , vol.50 , pp. 481-490
    • Jambunathan, S.1    Dasgupta, P.K.2    Wolcott, D.K.3    Marshall, G.D.4    Olson, D.C.5
  • 23
    • 0031274583 scopus 로고    scopus 로고
    • Development of a novel fluorimeter based on superluminescent light-emitting diodes and acousto-optic tunable filter and its application in the determination of chlorophylls a and b
    • Alexander TA, Gao G-H, Tran CD. 1997. Development of a novel fluorimeter based on superluminescent light-emitting diodes and acousto-optic tunable filter and its application in the determination of chlorophylls a and b. Appl. Spectrosc. 51:1603-6 (Pubitemid 127662629)
    • (1997) Applied Spectroscopy , vol.51 , Issue.11 , pp. 1603-1606
    • Alexander, T.A.1    Gao, G.-H.2    Tran, C.D.3
  • 24
    • 0141654828 scopus 로고    scopus 로고
    • Enhancement of detection sensitivity for indirect photometric detection of anions and cations in capillary electrophoresis
    • Johns C, Macka M, Haddad PR. 2003. Enhancement of detection sensitivity for indirect photometric detection of anions and cations in capillary electrophoresis. Electrophoresis 24:2150-67 (Pubitemid 38088997)
    • (2003) Electrophoresis , vol.24 , Issue.12-13 , pp. 2150-2167
    • Johns, C.1    Macka, M.2    Haddad, P.R.3
  • 25
    • 8344285761 scopus 로고    scopus 로고
    • Design and performance of a light-emitting diode detector compatible with a commercial capillary electrophoresis instrument
    • DOI 10.1002/elps.200405913
    • Johns C, Macka M, Haddad PR. 2004. Design and performance of a light-emitting diode detector compatible with a commercial capillary electrophoresis instrument. Electrophoresis 25:3145-52 (Pubitemid 39480882)
    • (2004) Electrophoresis , vol.25 , Issue.18-19 , pp. 3145-3152
    • Johns, C.1    Macka, M.2    Haddad, P.R.3
  • 26
    • 0030967654 scopus 로고    scopus 로고
    • Determination of barium and strontium by capillary zone electrophoresis using an electrolyte containing sulfonazo III
    • DOI 10.1016/S0021-9673(96)01066-7, PII S0021967396010667
    • MackaM, Paull B, Andersson P, Haddad PR. 1997. Determination of barium and strontium by capillary zone electrophoresis using an electrolyte containing Sulfonazo III. J. Chromatogr. A 767:303-10 (Pubitemid 27199270)
    • (1997) Journal of Chromatography A , vol.767 , Issue.1-2 , pp. 303-310
    • Macka, M.1    Paull, B.2    Andersson, P.3    Haddad, P.R.4
  • 27
    • 0027678987 scopus 로고
    • Double-beam laser indirect absorption detection in capillary electrophoresis
    • Xue Y, Yeung ES. 1993. Double-beam laser indirect absorption detection in capillary electrophoresis. Anal. Chem. 65:2923-27
    • (1993) Anal. Chem. , vol.65 , pp. 2923-2927
    • Xue, Y.1    Yeung, E.S.2
  • 28
    • 0004292309 scopus 로고    scopus 로고
    • Newburyport, MA: Int. Light
    • Ryer A, ed. 2000. Light Measurement Handbook. Newburyport, MA: Int. Light. http://www.dfisica. ubi.pt/?hgil/Fotometria/HandBook/ch07.html
    • (2000) Light Measurement Handbook
    • Ryer, A.1
  • 29
    • 84904302092 scopus 로고    scopus 로고
    • Labsphere North Sutton, NH: Labsphere
    • Labsphere, ed. 2008. The Radiometry of Light Emitting Diodes. North Sutton, NH: Labsphere. http://www.labsphere.com/uploads/technical-guides/ The%20Radiometry%20of%20Light% 20Emitting%20Diodes%20-%20LEDs.pdf
    • (2008) The Radiometry of Light Emitting Diodes
  • 30
    • 46749095575 scopus 로고    scopus 로고
    • History, development, and applications of high-brightness visible lightemitting diodes
    • Dupuis RD, Krames MR. 2008. History, development, and applications of high-brightness visible lightemitting diodes. J. Lightwave Technol. 26:1154-71
    • (2008) J. Lightwave Technol. , vol.26 , pp. 1154-1171
    • Dupuis, R.D.1    Krames, M.R.2
  • 31
    • 84857368758 scopus 로고    scopus 로고
    • Light-emitting diodes in modern microscopy-from David to Goliath?
    • Wessels JT, Pliquett U, Wouters FS. 2012. Light-emitting diodes in modern microscopy-from David to Goliath? Cytometry A 81A:188-97
    • (2012) Cytometry A , vol.81 A , pp. 188-197
    • Wessels, J.T.1    Pliquett, U.2    Wouters, F.S.3
  • 33
    • 39849094594 scopus 로고    scopus 로고
    • Effects of continuous-wave (670-nm) red light on wound healing
    • DOI 10.1111/j.1524-4725.2007.34065.x
    • Erdle BJ, Brouxhon S, Kaplan M, VanBuskirk J, Pentland AP. 2008. Effects of continuous-wave (670-nm) red light on wound healing. Dermatol. Surg. 34:320-25 (Pubitemid 351316822)
    • (2008) Dermatologic Surgery , vol.34 , Issue.3 , pp. 320-325
    • Erdle, B.J.1    Brouxhon, S.2    Kaplan, M.3    Vanbuskirk, J.4    Pentland, A.P.5
  • 34
    • 0001635177 scopus 로고    scopus 로고
    • Resolution improvement in optical coherence tomography by optimal synthesis of light-emitting diodes
    • Zhang Y, SatoM, Tanno N. 2001. Resolution improvement in optical coherence tomography by optimal synthesis of light-emitting diodes. Opt. Lett. 26:205-7 (Pubitemid 33693292)
    • (2001) Optics Letters , vol.26 , Issue.4 , pp. 205-207
    • Zhang, Y.1    Sato, M.2    Tanno, N.3
  • 37
    • 33846296241 scopus 로고    scopus 로고
    • Solid state pH sensor based on light emitting diodes (LED) as detector platform
    • Lau KT, Shepherd R, Diamond D. 2006. Solid state pH sensor based on light emitting diodes (LED) as detector platform. Sensors 6:848-59
    • (2006) Sensors , vol.6 , pp. 848-859
    • Lau, K.T.1    Shepherd, R.2    Diamond, D.3
  • 41
    • 0030883429 scopus 로고    scopus 로고
    • A fluorescence lifetime-based solid sensor for water
    • DOI 10.1016/S0003-2670(97)00298-5, PII S0003267097002985
    • Chang Q, Murtaza Z, Lakowicz JR, Rao G. 1997. A fluorescence lifetime-based solid sensor for water. Anal. Chim. Acta 350:97-104 (Pubitemid 27385396)
    • (1997) Analytica Chimica Acta , vol.350 , Issue.1-2 , pp. 97-104
    • Chang, Q.1    Murtaza, Z.2    Lakowicz, J.R.3    Rao, G.4
  • 42
    • 34250786595 scopus 로고    scopus 로고
    • An optical sensor for analysis of soil nutrients by using LED light sources
    • DOI 10.1088/0957-0233/18/7/052, PII S095702330746060X, 052
    • Yokota M, Okada T, Yamaguchi I. 2007. An optical sensor for analysis of soil nutrients by using LED light sources. Meas. Sci. Technol. 18:2197-201 (Pubitemid 46950800)
    • (2007) Measurement Science and Technology , vol.18 , Issue.7 , pp. 2197-2201
    • Yokota, M.1    Okada, T.2    Yamaguchi, I.3
  • 43
    • 27744505529 scopus 로고    scopus 로고
    • Multiwavelength sensing of smoke using a polychromatic LED: Mie extinction characterization using HLS analysis
    • DOI 10.1109/JSEN.2005.845207
    • Aspey RA, Brazier KJ, Spencer JW. 2005. Multiwavelength sensing of smoke using a polychromatic LED: Mie extinction characterization using HLS analysis. IEEE 5:1050-56 (Pubitemid 41583946)
    • (2005) IEEE Sensors Journal , vol.5 , Issue.5 , pp. 1050-1056
    • Aspey, R.A.1    Brazier, K.J.2    Spencer, J.W.3
  • 44
    • 84922686644 scopus 로고    scopus 로고
    • Metal-deposited optical fiber sensors based on surface plasmon resonance
    • MitsushioM, HigoM. 2012. Metal-deposited optical fiber sensors based on surface plasmon resonance. Bunseki Kagaku 61:999-1011
    • (2012) Bunseki Kagaku , vol.61 , pp. 999-1011
    • Mitsushio, M.1    Higo, M.2
  • 45
    • 0016919141 scopus 로고
    • Probe photometer based on optoelectronic components for the determination of total alkalinity in seawater
    • Anfalt T, Granéli A, Strandberg M. 1976. Probe photometer based on optoelectronic components for the determination of total alkalinity in seawater. Anal. Chem. 48:357-60
    • (1976) Anal. Chem. , vol.48 , pp. 357-360
    • Anfalt, T.1    Granéli, A.2    Strandberg, M.3
  • 46
    • 0025357972 scopus 로고
    • How to monitor ultraviolet radiation from the sun
    • Mims FM III. 1990. How to monitor ultraviolet radiation from the sun. Sci. Am. 263:106-9
    • (1990) Sci. Am. , vol.263 , pp. 106-109
    • Mims Iii., F.M.1
  • 47
    • 0142187731 scopus 로고    scopus 로고
    • Very low-cost sensing and communication using bidirectional LEDs
    • ed. AK Dey, A Schmidt, JF McCarthy Berlin/Heidelberg: Springer
    • Dietz P, Yerazunis W, Leigh D. 2003. Very low-cost sensing and communication using bidirectional LEDs. In UbiComp 2003: Ubiquitous Computing, ed. AK Dey, A Schmidt, JF McCarthy, pp. 175-91. Berlin/Heidelberg: Springer
    • (2003) UbiComp 2003: Ubiquitous Computing , pp. 175-191
    • Dietz, P.1    Yerazunis, W.2    Leigh, D.3
  • 48
    • 57649220825 scopus 로고    scopus 로고
    • Paired emitter-detector diode detection with dual wavelength monitoring for enhanced sensitivity to transition metals in ion chromatography with post-column reaction
    • OToole M, Barron L, Shepherd R, Paull B, Nesterenko P, Diamond D. 2009. Paired emitter-detector diode detection with dual wavelength monitoring for enhanced sensitivity to transition metals in ion chromatography with post-column reaction. Analyst 134:124-30
    • (2009) Analyst , vol.134 , pp. 124-130
    • Otoole, M.1    Barron, L.2    Shepherd, R.3    Paull, B.4    Nesterenko, P.5    Diamond, D.6
  • 50
    • 34547517498 scopus 로고    scopus 로고
    • Determination of phosphate using a highly sensitive paired emitter-detector diode photometric flow detector
    • DOI 10.1016/j.aca.2007.06.048, PII S0003267007010896
    • OToole M, Lau KT, Shepherd R, Slater C, Diamond D. 2007. Determination of phosphate using a highly sensitive paired emitter-detector diode photometric flow detector. Anal. Chim. Acta 597:290-94 (Pubitemid 47187823)
    • (2007) Analytica Chimica Acta , vol.597 , Issue.2 , pp. 290-294
    • O'Toole, M.1    Lau, K.T.2    Shepherd, R.3    Slater, C.4    Diamond, D.5
  • 51
    • 33645137576 scopus 로고    scopus 로고
    • Quantitative colorimetric analysis of dye mixtures using an optical photometer based on LED array
    • Lau KT, Yerazunis WS, Shepherd RL, Diamond D. 2006. Quantitative colorimetric analysis of dye mixtures using an optical photometer based on LED array. Sens. Actuators B 114:819-25
    • (2006) Sens. Actuators B , vol.114 , pp. 819-825
    • Lau, K.T.1    Yerazunis, W.S.2    Shepherd, R.L.3    Diamond, D.4
  • 52
    • 33746581696 scopus 로고    scopus 로고
    • Novel integrated paired emitter-detector diode (PEDD) as a miniaturized photometric detector in HPLC
    • DOI 10.1039/b602846b
    • OToole M, Lau KT, Shazmann B, Shepherd R, Nesterenko PN, et al. 2006. Novel integrated paired emitter-detector diode (PEDD) as a miniaturized photometric detector in HPLC. Analyst 131:938-43 (Pubitemid 44131399)
    • (2006) Analyst , vol.131 , Issue.8 , pp. 938-943
    • O'Toole, M.1    Lau, K.-T.2    Shazmann, B.3    Shepherd, R.4    Nesterenko, P.N.5    Paull, B.6    Diamond, D.7
  • 53
    • 54249157840 scopus 로고    scopus 로고
    • Paired emitter detector diode (PEDD)-based photometry-an alternative approach
    • Tymeckic L., Pokrzywnicka M, Koncki R. 2008. Paired emitter detector diode (PEDD)-based photometry-an alternative approach. Analyst 133:1501-4
    • (2008) Analyst , vol.133 , pp. 1501-1504
    • Tymeckic, L.1    Pokrzywnicka, M.2    Koncki, R.3
  • 54
    • 63349085157 scopus 로고    scopus 로고
    • Simplified paired-emitter-detector-diodes-based photometry with improved sensitivity
    • Tymecki L., Koncki R. 2009. Simplified paired-emitter-detector-diodes- based photometry with improved sensitivity. Anal. Chim. Acta 639:73-77
    • (2009) Anal. Chim. Acta , vol.639 , pp. 73-77
    • Tymeckic, L.1    Koncki, R.2
  • 55
    • 69949156528 scopus 로고    scopus 로고
    • A very simple photometer based on paired-emitterdetector diodes
    • Pokrzywnicka M, Koncki R, Tymecki L. 2009. A very simple photometer based on paired-emitterdetector diodes. Chem. Anal. 54:427-35
    • (2009) Chem. Anal. , vol.54 , pp. 427-435
    • Pokrzywnicka, M.1    Koncki, R.2    Tymecki, L.3
  • 56
    • 67649832374 scopus 로고    scopus 로고
    • UV-PEDD photometry dedicated for bioanalytical uses
    • Tymecki L, Brodacka L, Rozum B, Koncki R. 2009. UV-PEDD photometry dedicated for bioanalytical uses. Analyst 134:1333-37
    • (2009) Analyst , vol.134 , pp. 1333-1337
    • Tymecki, L.1    Brodacka, L.2    Rozum, B.3    Koncki, R.4
  • 57
    • 67549114848 scopus 로고    scopus 로고
    • A single standard calibration module for flow analysis systems based on solenoid microdevices
    • Tymecki L, Strzelak K, Koncki R. 2009. A single standard calibration module for flow analysis systems based on solenoid microdevices. Talanta 79:205-10
    • (2009) Talanta , vol.79 , pp. 205-210
    • Tymecki, L.1    Strzelak, K.2    Koncki, R.3
  • 58
    • 77649180003 scopus 로고    scopus 로고
    • Poly(vinyl chloride) tubing with covalently bound alkaline phosphatase and alternative approach for investigations of open-tubular bioreactors
    • Rozum B, GajownikK, Tymecki L, Koncki R. 2010. Poly(vinyl chloride) tubing with covalently bound alkaline phosphatase and alternative approach for investigations of open-tubular bioreactors. Anal. Biochem. 400:151-53
    • (2010) Anal. Biochem. , vol.400 , pp. 151-153
    • Rozum, B.1    Gajownik, K.2    Tymecki, L.3    Koncki, R.4
  • 59
    • 79954442750 scopus 로고    scopus 로고
    • Hemoglobin determination with paired emitter detector diode
    • Mieczkowska E, Koncki R, Tymecki L. 2011. Hemoglobin determination with paired emitter detector diode. Anal. Bioanal. Chem. 399:3293-97
    • (2011) Anal. Bioanal. Chem. , vol.399 , pp. 3293-3297
    • Mieczkowska, E.1    Koncki, R.2    Tymecki, L.3
  • 61
    • 84864287901 scopus 로고    scopus 로고
    • Serum alkaline phosphatase assay with paired emitter detector diode
    • Strzelak K, Koncki R, Tymecki L. 2012. Serum alkaline phosphatase assay with paired emitter detector diode. Talanta 96:127-31
    • (2012) Talanta , vol.96 , pp. 127-131
    • Strzelak, K.1    Koncki, R.2    Tymecki, L.3
  • 62
    • 84864287047 scopus 로고    scopus 로고
    • Low-cost optical detectors and flow systems for protein determination
    • Pokrzywnicka M, Tymecki L, Koncki R. 2012. Low-cost optical detectors and flow systems for protein determination. Talanta 96:121-26
    • (2012) Talanta , vol.96 , pp. 121-126
    • Pokrzywnicka, M.1    Tymecki, L.2    Koncki, R.3
  • 64
    • 84879880542 scopus 로고    scopus 로고
    • Multicommutated flow analysis system for determination of creatinine in physiological fluids by Jaffe method
    • Tymecki L, Korszun J, Strzelak K, Koncki R. 2013. Multicommutated flow analysis system for determination of creatinine in physiological fluids by Jaffe method. Anal. Chim. Acta 787:118-25
    • (2013) Anal. Chim. Acta , vol.787 , pp. 118-125
    • Tymecki, L.1    Korszun, J.2    Strzelak, K.3    Koncki, R.4
  • 65
    • 84884135001 scopus 로고    scopus 로고
    • Biparametric multicommutated flow analysis system for determination of human serum phosphoesterase activity
    • Tymecki L, Strzelak K, Koncki R. 2013. Biparametric multicommutated flow analysis system for determination of human serum phosphoesterase activity. Anal. Chim. Acta 797:57-63
    • (2013) Anal. Chim. Acta , vol.797 , pp. 57-63
    • Tymecki, L.1    Strzelak, K.2    Koncki, R.3
  • 66
    • 80755190113 scopus 로고    scopus 로고
    • A novel direct-injection photometric detector integrated with solenoid pulse-pump flow system
    • Koronkiewicz S, Kalinowski S. 2011. A novel direct-injection photometric detector integrated with solenoid pulse-pump flow system. Talanta 86:436-41
    • (2011) Talanta , vol.86 , pp. 436-441
    • Koronkiewicz, S.1    Kalinowski, S.2
  • 67
    • 84864288013 scopus 로고    scopus 로고
    • Application of direct-injection detector integrated with the multipumping flow system to photometric stop-flow determination of total iron
    • Koronkiewicz S, Kalinowski S. 2012. Application of direct-injection detector integrated with the multipumping flow system to photometric stop-flow determination of total iron. Talanta 96:68-74
    • (2012) Talanta , vol.96 , pp. 68-74
    • Koronkiewicz, S.1    Kalinowski, S.2
  • 68
    • 84879108107 scopus 로고    scopus 로고
    • Sequential injection system for simultaneous determination of sucrose and phosphate in cola drinks using paired emitterdetector diode sensor
    • SaetearP, Khamtau K, Ratanawimarnwong N, Sereenonchai K, NacaprichaD. 2013. Sequential injection system for simultaneous determination of sucrose and phosphate in cola drinks using paired emitterdetector diode sensor. Talanta 115:361-66
    • (2013) Talanta , vol.115 , pp. 361-366
    • Saetear, P.1    Khamtau, K.2    Ratanawimarnwong, N.3    Sereenonchai, K.4    Nacapricha, D.5
  • 69
    • 84884222794 scopus 로고    scopus 로고
    • Absorbance measurements with light-emitting diodes as sources: Silicon photodiodes or light-emitting diodes as detectors?
    • Bui DA, Hauser PC. 2013. Absorbance measurements with light-emitting diodes as sources: silicon photodiodes or light-emitting diodes as detectors? Talanta 116:1073-78
    • (2013) Talanta , vol.116 , pp. 1073-1078
    • Bui, D.A.1    Hauser, P.C.2
  • 70
    • 0015341104 scopus 로고
    • A light emitting diode skin reflectance oximeter
    • Cohen A, Wadsworth N. 1972. A light emitting diode skin reflectance oximeter. Med. Biol. Eng. 10:385-91
    • (1972) Med. Biol. Eng. , vol.10 , pp. 385-391
    • Cohen, A.1    Wadsworth, N.2
  • 71
    • 0004060924 scopus 로고
    • Light emitting diodes and phototransistors in photometric modules
    • Flaschka H, McKeithan C, Barnes RM. 1973. Light emitting diodes and phototransistors in photometric modules. Anal. Lett. 6:585-94
    • (1973) Anal. Lett. , vol.6 , pp. 585-594
    • Flaschka, H.1    McKeithan, C.2    Barnes, R.M.3
  • 72
    • 4444256976 scopus 로고    scopus 로고
    • Light at the end of the tunnel: Recent analytical applications of liquid-core waveguides
    • DOI 10.1016/S0165-9936(04)00522-9, PII S0165993604005229
    • Dallas T, Dasgupta PK. 2004. Light at the end of the tunnel: recent analytical applications of liquid-core waveguides. TrAC Trends Anal. Chem. 23:385-92 (Pubitemid 39177604)
    • (2004) TrAC - Trends in Analytical Chemistry , vol.23 , Issue.5 , pp. 385-392
    • Dallas, T.1    Dasgupta, P.K.2
  • 73
    • 0034306961 scopus 로고    scopus 로고
    • Continuous on-line true titrations by feedback-based flow ratiometry. The principle of compensating errors
    • Tanaka H, Dasgupta PK, Huang J. 2000. Continuous on-line true titrations by feedback-based flow ratiometry. The principle of compensating errors. Anal. Chem. 72:4713-20
    • (2000) Anal. Chem. , vol.72 , pp. 4713-4720
    • Tanaka, H.1    Dasgupta, P.K.2    Huang, J.3
  • 75
    • 4444282981 scopus 로고    scopus 로고
    • A multichannel photometer based on an array of light emitting diodes for use in multivariate calibration
    • DOI 10.1016/j.aca.2004.06.063, PII S0003267004008116
    • Fonseca A, Raimundo IMJ. 2004. A multichannel photometer based on an array of light-emitting diodes for use in multivariate calibration. Anal. Chim. Acta 522:223-29 (Pubitemid 39179979)
    • (2004) Analytica Chimica Acta , vol.522 , Issue.2 , pp. 223-229
    • Fonseca, A.1    Raimundo Jr., I.M.2
  • 76
    • 77951049898 scopus 로고    scopus 로고
    • Hand-held photometer based on liquid-core waveguide absorption detection for nanoliter-scale samples
    • Pan JZ, Yao B, Fang Q. 2010. Hand-held photometer based on liquid-core waveguide absorption detection for nanoliter-scale samples. Anal. Chem. 82:3394-98
    • (2010) Anal. Chem. , vol.82 , pp. 3394-3398
    • Pan, J.Z.1    Yao, B.2    Fang, Q.3
  • 77
    • 33947411275 scopus 로고    scopus 로고
    • A novel type of tri-colour light-emitting-diode-based spectrometric detector for lowbudget flow-injection analysis
    • Gros N. 2007. A novel type of tri-colour light-emitting-diode-based spectrometric detector for lowbudget flow-injection analysis. Sensors 7:166-84
    • (2007) Sensors , vol.7 , pp. 166-184
    • Gros, N.1
  • 78
    • 0033761279 scopus 로고    scopus 로고
    • A portable spectrophotometer using a whitecolour light-emitting diode and a charge-coupled device and its application to on-site determination of iron
    • Shimazaki Y, Watanabe S, Takahashi M, Iwatsuki M. 2000. A portable spectrophotometer using a whitecolour light-emitting diode and a charge-coupled device and its application to on-site determination of iron. Anal. Sci. 16:1091-93
    • (2000) Anal. Sci. , vol.16 , pp. 1091-1093
    • Shimazaki, Y.1    Watanabe, S.2    Takahashi, M.3    Iwatsuki, M.4
  • 79
    • 0037430258 scopus 로고    scopus 로고
    • Portable flow-injection analyzer with liquid-core waveguide based fluorescence, luminescence, and long path length absorbance detector
    • DOI 10.1016/S0003-2670(02)01531-3
    • Li Q, Morris KJ, Dasgupta PK, Raimundo IM Jr, Temkin H. 2003. Portable flow-injection analyzer with liquid-core waveguide based fluorescence, luminescence, and long path length absorbance detector. Anal. Chim. Acta 479:151-65 (Pubitemid 36173921)
    • (2003) Analytica Chimica Acta , vol.479 , Issue.2 , pp. 151-165
    • Li, Q.1    Morris, K.J.2    Dasgupta, P.K.3    Raimundo Jr., I.M.4    Temkin, H.5
  • 80
    • 56749185565 scopus 로고    scopus 로고
    • Automated measurement of urinary creatinine by multichannel kinetic spectrophotometry
    • Ohira SI, Kirk AB, Dasgupta PK. 2009. Automated measurement of urinary creatinine by multichannel kinetic spectrophotometry. Anal. Biochem. 384:238-44
    • (2009) Anal. Biochem. , vol.384 , pp. 238-244
    • Ohira, S.I.1    Kirk, A.B.2    Dasgupta, P.K.3
  • 81
    • 84855335537 scopus 로고    scopus 로고
    • Design and development of novel sensors for the determination of fluoride in water
    • Pillai AB, Varghese B, Madhusoodanan KN. 2012. Design and development of novel sensors for the determination of fluoride in water. Environ. Sci. Technol. 46:404-9
    • (2012) Environ. Sci. Technol. , vol.46 , pp. 404-409
    • Pillai, A.B.1    Varghese, B.2    Madhusoodanan, K.N.3
  • 82
    • 84864851007 scopus 로고    scopus 로고
    • A simplemicrofluidic integrated with an optical sensor for micro flow injection colorimetric determination of glutathione
    • Supharoek S-A, Youngvises N, Jakmunee J. 2012. A simplemicrofluidic integrated with an optical sensor for micro flow injection colorimetric determination of glutathione. Anal. Sci. 28:651-56
    • (2012) Anal. Sci. , vol.28 , pp. 651-656
    • Supharoek, S.-A.1    Youngvises, N.2    Jakmunee, J.3
  • 83
    • 84867223731 scopus 로고    scopus 로고
    • Miniaturized optical system for detection of ammonia nitrogen in water based on gas-phase colorimetry
    • Yao YQ, Lu DF, Qi ZM, Xia SH. 2012. Miniaturized optical system for detection of ammonia nitrogen in water based on gas-phase colorimetry. Anal. Lett. 45:2176-84
    • (2012) Anal. Lett. , vol.45 , pp. 2176-2184
    • Yao, Y.Q.1    Lu, D.F.2    Qi, Z.M.3    Xia, S.H.4
  • 84
    • 33748797933 scopus 로고    scopus 로고
    • A membraneless gas diffusion unit: Design and its application to determination of ethanol in liquors by spectrophotometric flow injection
    • DOI 10.1016/j.aca.2006.07.018, PII S0003267006015054
    • Choengchan N, Mantim T, Wilairat P, DasguptaPK, Motomizu S, NacaprichaD. 2006.Amembraneless gas diffusion unit: design and its application to determination of ethanol in liquors by spectrophotometric flow injection. Anal. Chim. Acta 579:33-37 (Pubitemid 44416379)
    • (2006) Analytica Chimica Acta , vol.579 , Issue.1 , pp. 33-37
    • Choengchan, N.1    Mantim, T.2    Wilairat, P.3    Dasgupta, P.K.4    Motomizu, S.5    Nacapricha, D.6
  • 85
    • 34047257974 scopus 로고    scopus 로고
    • Thin layer distillation for matrix isolation in flow analysis
    • DOI 10.1016/j.talanta.2006.12.002, PII S0039914006007818
    • Mornane P, van den Haak J, Cardwell TJ, Cattrall RW, Dasgupta PK, Kolev SD. 2007. Thin layer distillation for matrix isolation in flow analysis. Talanta 72:741-46 (Pubitemid 46550641)
    • (2007) Talanta , vol.72 , Issue.2 , pp. 741-746
    • Mornane, P.1    Van Den Haak, J.2    Cardwell, T.J.3    Cattrall, R.W.4    Dasgupta, P.K.5    Kolev, S.D.6
  • 86
    • 0033562612 scopus 로고    scopus 로고
    • Automated measurement of lipid hydroperoxides in oil and fat samples by flow injection photometry
    • DOI 10.1021/ac9813181
    • Tian K, Dasgupta PK. 1999. Automated measurement of lipid hydroperoxides in oil and fat samples by flow injection photometry. Anal. Chem. 71:2053-58 (Pubitemid 29233171)
    • (1999) Analytical Chemistry , vol.71 , Issue.10 , pp. 2053-2058
    • Tian, K.1    Dasgupta, P.K.2
  • 87
    • 84873372361 scopus 로고    scopus 로고
    • Using a flow-batch analyzer for photometric determination of Fe(III) in edible and lubricating oils without external pretreatment
    • Barreto IS, Lima MB, Andrade SIE, Araujo MCU, Almeida LF. 2013. Using a flow-batch analyzer for photometric determination of Fe(III) in edible and lubricating oils without external pretreatment. Anal. Methods 5:1040-45
    • (2013) Anal. Methods , vol.5 , pp. 1040-1045
    • Barreto, I.S.1    Lima, M.B.2    Andrade, S.I.E.3    Araujo, M.C.U.4    Almeida, L.F.5
  • 88
    • 34347352276 scopus 로고    scopus 로고
    • A novel long path length absorbance spectroscopy for the determination of ultra trace organophosphorus pesticides in vegetables and fruits
    • DOI 10.1016/j.saa.2006.10.018, PII S1386142506005889
    • ChengX, Zhang Z, Tian S. 2007.Anovel long path length absorbance spectroscopy for the determination of ultra trace organophosphorus pesticides in vegetables and fruits. Spectrochim. Acta A 67:1270-75 (Pubitemid 47017768)
    • (2007) Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy , vol.67 , Issue.5 , pp. 1270-1275
    • Cheng, X.1    Zhang, Z.2    Tian, S.3
  • 89
    • 15744399889 scopus 로고    scopus 로고
    • Determination of acetone in breath
    • DOI 10.1016/j.aca.2004.12.018, PII S0003267004016538
    • Teshima N, Li J, Toda K, Dasgupta PK. 2005. Determination of acetone in breath. Anal. Chim. Acta 535:189-99 (Pubitemid 40410512)
    • (2005) Analytica Chimica Acta , vol.535 , Issue.1-2 , pp. 189-199
    • Teshima, N.1    Li, J.2    Toda, K.3    Dasgupta, P.K.4
  • 90
    • 0038218253 scopus 로고    scopus 로고
    • Selective measurement of gaseous hydrogen peroxide with light emitting diode-based liquid-core waveguide absorbance detector
    • Li J, Dasgupta PK. 2003. Selective measurement of gaseous hydrogen peroxide with light emitting diode-based liquid-core waveguide absorbance detector. Anal. Sci. 19:517-23
    • (2003) Anal. Sci. , vol.19 , pp. 517-523
    • Li, J.1    Dasgupta, P.K.2
  • 91
    • 23044470831 scopus 로고    scopus 로고
    • Speciation-capable field instrument for the measurement of arsenite and arsenate in water
    • DOI 10.1021/ac050193e
    • Toda K, Ohba T, Takaki M, Karthikeyan S, Hirata S, Dasgupta PK. 2005. Speciation-capable field instrument for the measurement of arsenite and arsenate in water. Anal. Chem. 77:4765-73 (Pubitemid 41076665)
    • (2005) Analytical Chemistry , vol.77 , Issue.15 , pp. 4765-4773
    • Toda, K.1    Ohba, T.2    Takaki, M.3    Karthikeyan, S.4    Hirata, S.5    Dasgupta, P.K.6
  • 92
    • 67649381652 scopus 로고    scopus 로고
    • Liquid-waveguide spectrophotometric measurement of low silicate in natural waters
    • Amornthammarong N, Zhang JZ. 2009. Liquid-waveguide spectrophotometric measurement of low silicate in natural waters. Talanta 79:621-26
    • (2009) Talanta , vol.79 , pp. 621-626
    • Amornthammarong, N.1    Zhang, J.Z.2
  • 93
    • 77954642382 scopus 로고    scopus 로고
    • Cobinamide-based cyanide analysis by multiwavelength spectrometry in a liquid core waveguide
    • Ma J, Dasgupta PK, Blackledge W, Boss GR. 2010. Cobinamide-based cyanide analysis by multiwavelength spectrometry in a liquid core waveguide. Anal. Chem. 82:6244-50
    • (2010) Anal. Chem. , vol.82 , pp. 6244-6250
    • Ma, J.1    Dasgupta, P.K.2    Blackledge, W.3    Boss, G.R.4
  • 94
    • 84863448397 scopus 로고    scopus 로고
    • Cobinamide chemistries for photometric cyanide determination. A merging zone liquid core waveguide cyanide analyzer using cyanoaquacobinamide
    • Ma J, Dasgupta PK, Zelder FH, Boss GR. 2012. Cobinamide chemistries for photometric cyanide determination. A merging zone liquid core waveguide cyanide analyzer using cyanoaquacobinamide. Anal. Chim. Acta 736:78-84
    • (2012) Anal. Chim. Acta , vol.736 , pp. 78-84
    • Ma, J.1    Dasgupta, P.K.2    Zelder, F.H.3    Boss, G.R.4
  • 95
    • 79957946747 scopus 로고    scopus 로고
    • Rapid point of care analyzer for the measurement of cyanide in blood
    • Ma J, Ohira SI, Mishra SK, Puanngam M, Dasgupta PK, et al. 2011. Rapid point of care analyzer for the measurement of cyanide in blood. Anal. Chem. 83:4319-24
    • (2011) Anal. Chem. , vol.83 , pp. 4319-4324
    • Ma, J.1    Ohira, S.I.2    Mishra, S.K.3    Puanngam, M.4    Dasgupta, P.K.5
  • 97
    • 66149096643 scopus 로고    scopus 로고
    • Broadband cavity enhanced absorption spectroscopy as a detector for HPLC
    • Seetohul LN, Ali Z, Islam M. 2009. Broadband cavity enhanced absorption spectroscopy as a detector for HPLC. Anal. Chem. 81:4106-12
    • (2009) Anal. Chem. , vol.81 , pp. 4106-4112
    • Seetohul, L.N.1    Ali, Z.2    Islam, M.3
  • 98
    • 84874101745 scopus 로고    scopus 로고
    • Wavelength-resolved optical extinction measurements of aerosols using broad-band cavity-enhanced absorption spectroscopy over the spectral range of 445-480 nm
    • Zhao WX, Dong ML, Chen WD, Gu XJ, Hu CJ, et al. 2013. Wavelength-resolved optical extinction measurements of aerosols using broad-band cavity-enhanced absorption spectroscopy over the spectral range of 445-480 nm. Anal. Chem. 85:2260-68
    • (2013) Anal. Chem. , vol.85 , pp. 2260-2268
    • Zhao, W.X.1    Dong, M.L.2    Chen, W.D.3    Gu, X.J.4    Hu, C.J.5
  • 99
    • 84859435235 scopus 로고    scopus 로고
    • A portable photometer based on LED for the determination of aromatic hydrocarbons in water
    • Gomes de Lima KM. 2012. A portable photometer based on LED for the determination of aromatic hydrocarbons in water. Microchem. J. 103:62-67
    • (2012) Microchem. J. , vol.103 , pp. 62-67
    • Gomes De Lima, K.M.1
  • 100
    • 84862510969 scopus 로고    scopus 로고
    • Short-wave near-infrared spectrometer for alcohol determination and temperature correction
    • Fu QB, Wang JM, Lin GN, Suo H, Zhao C. 2012. Short-wave near-infrared spectrometer for alcohol determination and temperature correction. J. Anal. Methods Chem. 2012:728128
    • (2012) J. Anal. Methods Chem. , vol.2012 , pp. 728128
    • Fu, Q.B.1    Wang, J.M.2    Lin, G.N.3    Suo, H.4    Zhao, C.5
  • 101
    • 0345708293 scopus 로고    scopus 로고
    • Multi-reflection photometric flow cell for use in flow injection analysis of estuarine waters
    • DOI 10.1016/S0003-2670(03)00682-2
    • Ellis PS, Lyddy-Meaney AJ, Worsfold PJ, McKelvie ID. 2003. Multi-reflection photometric flow cell for use in flow injection analysis of estuarine waters. Anal. Chim. Acta 499:81-89 (Pubitemid 37487800)
    • (2003) Analytica Chimica Acta , vol.499 , Issue.1-2 , pp. 81-89
    • Ellis, P.S.1    Lyddy-Meaney, A.J.2    Worsfold, P.J.3    McKelvie, I.D.4
  • 102
    • 84860727605 scopus 로고    scopus 로고
    • Sequential injection system exploring the standard addition method for phosphate determination in high salinity samples: Interstitial, transitional and coastal waters
    • Mesquita RBR, Santos IC, Bordalo AA, Rangel AOSS. 2012. Sequential injection system exploring the standard addition method for phosphate determination in high salinity samples: interstitial, transitional and coastal waters. Anal. Methods 4:1452-57
    • (2012) Anal. Methods , vol.4 , pp. 1452-1457
    • Mesquita, R.B.R.1    Santos, I.C.2    Bordalo, A.A.3    Rangel, A.O.S.S.4
  • 103
    • 36148981820 scopus 로고    scopus 로고
    • Capillary scale light emitting diode based multi-reflection absorbance detector
    • DOI 10.1016/j.aca.2007.10.030, PII S0003267007017606
    • Mishra SK, Dasgupta PK. 2007. Capillary scale light emitting diode based multi-reflection absorbance detector. Anal. Chim. Acta 605:166-74 (Pubitemid 350116755)
    • (2007) Analytica Chimica Acta , vol.605 , Issue.2 , pp. 166-174
    • Mishra, S.K.1    Dasgupta, P.K.2
  • 104
    • 33646564028 scopus 로고    scopus 로고
    • Frequency-selective absorbance detection: Refractive index and turbidity compensation with dual-wavelength measurement
    • DOI 10.1016/j.talanta.2005.11.033, PII S0039914005007617
    • Eom IY, Dasgupta PK. 2006. Frequency-selective absorbance detection: refractive index and turbidity compensation with dual-wavelength measurement. Talanta 69:906-13 (Pubitemid 43729899)
    • (2006) Talanta , vol.69 , Issue.4 , pp. 906-913
    • Eom, I.-Y.1    Dasgupta, P.K.2
  • 105
    • 0030994924 scopus 로고    scopus 로고
    • An affordable high-performance optical absorbance detector for capillary systems
    • DOI 10.1016/S0003-2670(96)00571-5, PII S0003267096005715
    • Boring CB, DasguptaPK. 1997. An affordable high-performance optical absorbance detector for capillary systems. Anal. Chim. Acta 342:123-32 (Pubitemid 27223307)
    • (1997) Analytica Chimica Acta , vol.342 , Issue.2-3 , pp. 123-132
    • Boring, C.B.1    Dasgupta, P.K.2
  • 106
    • 33750319684 scopus 로고    scopus 로고
    • Non-aqueous capillary electrophoresis with red light emitting diode absorbance detection for the analysis of basic dyes
    • DOI 10.1016/j.aca.2006.07.066, PII S0003267006016436
    • Fakhari AR, Breadmore MC, Macka M, Haddad PR. 2006. Non-aqueous capillary electrophoresis with red light emitting diode absorbance detection for the analysis of basic dyes. Anal. Chim. Acta 580:188-93 (Pubitemid 44633843)
    • (2006) Analytica Chimica Acta , vol.580 , Issue.2 , pp. 188-193
    • Fakhari, A.R.1    Breadmore, M.C.2    Macka, M.3    Haddad, P.R.4
  • 107
    • 0036452749 scopus 로고    scopus 로고
    • Separation and determination of vanadium in fertiliser by capillary electrophoresis with a light-emitting diode detector
    • DOI 10.1007/s00216-002-1564-8
    • Vachirapatama N, Macka M, Haddad PR. 2002. Separation and determination of vanadium in fertilizer by capillary electrophoresis with a light-emitting diode detector. Anal. Bioanal. Chem. 374:1082-85 (Pubitemid 35447440)
    • (2002) Analytical and Bioanalytical Chemistry , vol.374 , Issue.6 , pp. 1082-1085
    • Vachirapatama, N.1    Macka, M.2    Haddad, P.R.3
  • 108
    • 0035843864 scopus 로고    scopus 로고
    • Separation of niobium(V) and tantalum(V) as ternary complexes with citrate and metallochromic ligands by capillary electrophoresis
    • DOI 10.1016/S0003-2670(01)00833-9, PII S0003267001008339
    • Vachirapatama N, Doble P, Yu Z, Macka M, Haddad PR. 2001. Separation of niobium(V) and tantalum( V) as ternary complexes with citrate and metallochromic ligands by capillary electrophoresis. Anal. Chim. Acta 434:301-7 (Pubitemid 32411543)
    • (2001) Analytica Chimica Acta , vol.434 , Issue.2 , pp. 301-307
    • Vachirapatama, N.1    Doble, P.2    Yu, Z.3    Macka, M.4    Haddad, P.R.5
  • 109
    • 0034077193 scopus 로고    scopus 로고
    • Indirect photomeric detection of anions in capillary electrophoresis using dyes as probes and electrolytes buffered with an isoelectric ampholyte
    • DOI 10.1002/(SICI)1522-2683(20000401)21:7<1312::AID-ELPS1312>3.0. CO;2-9
    • Johns C, MackaM, HaddadPR. 2000. Indirect photomeric detection of anions in capillary electrophoresis using dyes as probes and electrolytes buffered with an isoelectric ampholyte. Electrophoresis 21:1312-19 (Pubitemid 30304146)
    • (2000) Electrophoresis , vol.21 , Issue.7 , pp. 1312-1319
    • Johns, C.1    Macka, M.2    Haddad, P.R.3
  • 110
    • 0030474502 scopus 로고    scopus 로고
    • Linearity evaluation in absorbance detection: The use of light-emitting diodes for on-capillary detection in capillary electrophoresis
    • DOI 10.1002/elps.1150171215
    • Macka M, Andersson P, Haddad PR. 1996. Linearity evaluation in absorbance detection: the use of light-emitting diodes for on-capillary detection in capillary electrophoresis. Electrophoresis 17:1898-905 (Pubitemid 27046456)
    • (1996) Electrophoresis , vol.17 , Issue.12 , pp. 1898-1905
    • Macka, M.1    Andersson, P.2    Haddad, P.R.3
  • 111
    • 0035943491 scopus 로고    scopus 로고
    • Practical method for evaluation of linearity and effective pathlength of on-capillary photometric detectors in capillary electrophoresis
    • DOI 10.1016/S0021-9673(01)01095-0, PII S0021967301010950
    • Johns C, MackaM, Haddad PR, King M, Paull B. 2001. Practical method for evaluation of linearity and effective pathlength of on-capillary photometric detectors in capillary electrophoresis. J. Chromatogr. A 927:237-41 (Pubitemid 32778421)
    • (2001) Journal of Chromatography A , vol.927 , Issue.1-2 , pp. 237-241
    • Johns, C.1    Macka, M.2    Haddad, P.R.3    King, M.4    Paull, B.5
  • 112
    • 72449132962 scopus 로고    scopus 로고
    • Deep-UV-LEDs in photometric detection: A 255 nm LED on-capillary detector in capillary electrophoresis
    • Krcmová L, Stjernlof A, Mehlen S, Hauser PC, Abele S, et al. 2009. Deep-UV-LEDs in photometric detection: a 255 nm LED on-capillary detector in capillary electrophoresis. Analyst 134: 2394-96
    • (2009) Analyst , vol.134 , pp. 2394-2396
    • Krcmová L, S.1
  • 113
    • 75749094033 scopus 로고    scopus 로고
    • Combined contactless conductometric, photometric, and fluorimetric single point detector for capillary separationmethods
    • Ryvolová M, Preisler J, Foret F, Hauser PC, Krásensky P, et al. 2010. Combined contactless conductometric, photometric, and fluorimetric single point detector for capillary separationmethods. Anal. Chem. 82:129-35
    • (2010) Anal. Chem. , vol.82 , pp. 129-135
    • Ryvolová, M.1    Preisler, J.2    Foret, F.3    Hauser, P.C.4    Krásensky, P.5
  • 114
    • 38349164816 scopus 로고    scopus 로고
    • Investigations on LED illumination for micro-PIV including a novel front-lit configuration
    • Hagsater SM, Westergaard CH, Bruus H, Kutter JP. 2008. Investigations on LED illumination for micro-PIV including a novel front-lit configuration. Exp. Fluids 44:211-19
    • (2008) Exp. Fluids , vol.44 , pp. 211-219
    • Hagsater, S.M.1    Westergaard, C.H.2    Bruus, H.3    Kutter, J.P.4
  • 116
    • 10944225183 scopus 로고    scopus 로고
    • Recent developments in detection for microfluidic systems
    • DOI 10.1002/elps.200406108
    • Mogensen KB, Klank H, Kutter JP. 2004. Recent developments in detection for microfluidic systems. Electrophoresis 25:3498-512 (Pubitemid 40012109)
    • (2004) Electrophoresis , vol.25 , Issue.21-22 , pp. 3498-3512
    • Mogensen, K.B.1    Klank, H.2    Kutter, J.P.3
  • 118
    • 34848830411 scopus 로고    scopus 로고
    • Optical sensing systems for microfluidic devices: A review
    • DOI 10.1016/j.aca.2007.08.046, PII S0003267007014444
    • Kuswandi B, Nuriman, Huskens J, Verboom W. 2007. Optical sensing systems for microfluidic devices: a review. Anal. Chim. Acta 601:141-55 (Pubitemid 47505229)
    • (2007) Analytica Chimica Acta , vol.601 , Issue.2 , pp. 141-155
    • Kuswandi, B.1    Nuriman2    Huskens, J.3    Verboom, W.4
  • 119
    • 41349088392 scopus 로고    scopus 로고
    • Broadband quantum dot micro-light-emitting diodes with parabolic sidewalls
    • Tanriseven S, Maaskant P, Corbett B. 2008. Broadband quantum dot micro-light-emitting diodes with parabolic sidewalls. Appl. Phys. Lett. 92:123501
    • (2008) Appl. Phys. Lett. , vol.92 , pp. 123501
    • Tanriseven, S.1    Maaskant, P.2    Corbett, B.3
  • 121
    • 0033892278 scopus 로고    scopus 로고
    • Micro- and sub-nanosecond lifetime measurements using a UV light-emitting diode
    • Szmacinski H, Chang Q. 2000. Micro-and sub-nanosecond lifetime measurements using a UV lightemitting diode. Appl. Spectrosc. 54:106-9 (Pubitemid 30549785)
    • (2000) Applied Spectroscopy , vol.54 , Issue.1 , pp. 106-109
    • Szmacinski, H.1    Chang, Q.2
  • 122
    • 0034921426 scopus 로고    scopus 로고
    • Frequency-domain fluorescence microscopy with the LED as a light source
    • DOI 10.1046/j.1365-2818.2001.00943.x
    • Herman P, Maliwal BP, Lin HJ, Lakowicz JR. 2001. Frequency-domain fluorescence microscopy with the LED as a light source. J. Microsc. 203:176-81 (Pubitemid 32701826)
    • (2001) Journal of Microscopy , vol.203 , Issue.2 , pp. 176-181
    • Herman, P.1    Maliwal, B.P.2    Lin, H.-J.3    Lakowicz, J.R.4
  • 123
    • 47249085126 scopus 로고    scopus 로고
    • Frequency domain fluorometry with pulsed light-emitting diodes
    • DOI 10.1196/annals.1430.026, Fluorescence Methods and Applications: Spectroscopy, Imaging, and Probes
    • Herman P, Vecer J. 2008. Frequency domain fluorometry with pulsed light-emitting diodes. Ann. NY Acad. Sci. 1130:56-61 (Pubitemid 351990248)
    • (2008) Annals of the New York Academy of Sciences , vol.1130 , pp. 56-61
    • Herman, P.1    Vecer, J.2
  • 124
    • 33745627020 scopus 로고    scopus 로고
    • An aluminium nitride light-emitting diode with a wavelength of 210 nanometres
    • DOI 10.1038/nature04760, PII NATURE04760
    • Taniyasu Y, Kasu M, Makimoto T. 2006. An aluminium nitride light-emitting diode with a wavelength of 210 nanometres. Nature 441:325-28 (Pubitemid 44050193)
    • (2006) Nature , vol.441 , Issue.7091 , pp. 325-328
    • Taniyasu, Y.1    Kasu, M.2    Makimoto, T.3
  • 125
    • 31144437154 scopus 로고    scopus 로고
    • Long-lived visible luminescence of UV LEDs and impact on LED excited time-resolved fluorescence applications
    • DOI 10.1088/0022-3727/39/3/006, PII S0022372706102934
    • Jin D, Connally R, Piper J. 2006. Long-lived visible luminescence of UV LEDs and impact on LED excited time-resolved fluorescence applications. J. Phys. D 39:461-65 (Pubitemid 43133803)
    • (2006) Journal of Physics D: Applied Physics , vol.39 , Issue.3 , pp. 461-465
    • Jin, D.1    Connally, R.2    Piper, J.3
  • 126
    • 33745685449 scopus 로고    scopus 로고
    • Low-picomolar limits of detection using high-power light-emitting diodes for fluorescence
    • de Jong EP, Lucy CA. 2006. Low-picomolar limits of detection using high-power light-emitting diodes for fluorescence. Analyst 131:664-69
    • (2006) Analyst , vol.131 , pp. 664-669
    • De Jong, E.P.1    Lucy, C.A.2
  • 127
    • 21744441490 scopus 로고    scopus 로고
    • Spectral filtering of light-emitting diodes for fluorescence detection
    • DOI 10.1016/j.aca.2005.05.005, PII S0003267005008019
    • de Jong EP, Lucy CA. 2005. Spectral filtering of light-emitting diodes for fluorescence detection. Anal. Chim. Acta 546:37-45 (Pubitemid 40943372)
    • (2005) Analytica Chimica Acta , vol.546 , Issue.1 , pp. 37-45
    • De Jong, E.P.1    Lucy, C.A.2
  • 128
    • 0037296796 scopus 로고    scopus 로고
    • Ultrafast analysis of oligosaccharides on microchip with light-emitting diode confocal fluorescence detection
    • DOI 10.1002/elps.200390086
    • Dang F, Zhang L, Hagiwara H, Mishina Y, Baba Y. 2003. Ultrafast analysis of oligosaccharides on microchip with light-emitting diode confocal fluorescence detection. Electrophoresis 24:714-21 (Pubitemid 36336397)
    • (2003) Electrophoresis , vol.24 , Issue.4 , pp. 714-721
    • Dang, F.1    Zhang, L.2    Hagiwara, H.3    Mishina, Y.4    Baba, Y.5
  • 129
    • 33644822835 scopus 로고    scopus 로고
    • Rapid analysis of oligosaccharides derived from glycoproteins by microchip electrophoresis
    • DOI 10.1016/j.chroma.2005.11.133, PII S0021967305023745, 19th International Symposium on MicroScale Bioseparations
    • Dang F, Kakehi K, Nakajima K, Shinohara Y, IshikawaM, et al. 2006. Rapid analysis of oligosaccharides derived from glycoproteins by microchip electrophoresis. J. Chromatogr. A 1109:138-43 (Pubitemid 43358034)
    • (2006) Journal of Chromatography A , vol.1109 , Issue.2 , pp. 138-143
    • Dang, F.1    Kakehi, K.2    Nakajima, K.3    Shinohara, Y.4    Ishikawa, M.5    Kaji, N.6    Tokeshi, M.7    Baba, Y.8
  • 130
    • 0037953093 scopus 로고    scopus 로고
    • Characterization of electrophoretic behavior of sugar isomers by microchip electrophoresis coupled with videomicroscopy
    • DOI 10.1021/ac034110a
    • Dang F, Zhang L, Jabasini M, Kaji N, Baba Y. 2003. Characterization of electrophoretic behavior of sugar isomers by microchip electrophoresis coupled with videomicroscopy. Anal. Chem. 75:2433-39 (Pubitemid 36582829)
    • (2003) Analytical Chemistry , vol.75 , Issue.10 , pp. 2433-2439
    • Dang, F.1    Zhang, L.2    Jabasini, M.3    Kaji, N.4    Baba, Y.5
  • 134
    • 84876138716 scopus 로고    scopus 로고
    • Development of a field-portable fluorometer based on deep ultraviolet LEDs for the detection of phenanthrene-and tryptophan-like compounds in natural waters
    • Tedetti M, Joffre P, Goutx M. 2013. Development of a field-portable fluorometer based on deep ultraviolet LEDs for the detection of phenanthrene-and tryptophan-like compounds in natural waters. Sens. Actuators B 182:416-23
    • (2013) Sens. Actuators B , vol.182 , pp. 416-423
    • Tedetti, M.1    Joffre, P.2    Goutx, M.3
  • 135
    • 0035577932 scopus 로고    scopus 로고
    • Fluorometric field instrument for continuous measurement of atmospheric hydrogen sulfide
    • DOI 10.1021/ac010602g
    • Toda K, Dasgupta PK, Li J, Tarver GA, Zarus GM. 2001. Fluorometric field instrument for continuous measurement of atmospheric hydrogen sulfide. Anal. Chem. 73:5716-24 (Pubitemid 33126729)
    • (2001) Analytical Chemistry , vol.73 , Issue.23 , pp. 5716-5724
    • Toda, K.1    Dasgupta, P.K.2    Li, J.3    Tarver, G.A.4    Zarus, G.M.5
  • 137
    • 13844299046 scopus 로고    scopus 로고
    • Measurement of gaseous and aqueous trace formaldehyde: Revisiting the pentanedione reaction and field applications
    • DOI 10.1016/j.aca.2004.09.087, PII S0003267004012826
    • Li J, Dasgupta PK, LukeW. 2005. Measurement of gaseous and aqueous trace formaldehyde: revisiting the pentanedione reaction and field applications. Anal. Chim. Acta 531:51-68 (Pubitemid 40255173)
    • (2005) Analytica Chimica Acta , vol.531 , Issue.1 , pp. 51-68
    • Li, J.1    Dasgupta, P.K.2    Luke, W.3
  • 140
    • 68849125273 scopus 로고    scopus 로고
    • Micro gas analyzermeasurement of nitric oxide in breath by direct wet scrubbing and fluorescence detection
    • Toda K, Koga T, Kosuge J, KashiwagiM, Oguchi H, ArimotoT. 2009. Micro gas analyzermeasurement of nitric oxide in breath by direct wet scrubbing and fluorescence detection. Anal. Chem. 81:7031-37
    • (2009) Anal. Chem. , vol.81 , pp. 7031-7037
    • Toda, K.1    Koga, T.2    Kosuge, J.3    Kashiwagi, M.4    Oguchi, H.5    Arimoto, T.6
  • 141
    • 39449091321 scopus 로고    scopus 로고
    • Shipboard fluorometric flow analyzer for high-resolution underway measurement of ammonium in seawater
    • DOI 10.1021/ac701942f
    • Amornthammarong N, Zhang JZ. 2008. Shipboard fluorometric flow analyzer for high-resolution underway measurement of ammonium in seawater. Anal. Chem. 80:1019-26 (Pubitemid 351272333)
    • (2008) Analytical Chemistry , vol.80 , Issue.4 , pp. 1019-1026
    • Amornthammarong, N.1    Zhang, J.-Z.2
  • 143
    • 79960369713 scopus 로고    scopus 로고
    • Anautonomous batch analyzer for the determination of trace ammonium in natural waters using fluorometric detection
    • Amornthammarong N, Zhang JZ, Ortner PB. 2011.Anautonomous batch analyzer for the determination of trace ammonium in natural waters using fluorometric detection. Anal. Methods 3:1501-6
    • (2011) Anal. Methods , vol.3 , pp. 1501-1506
    • Amornthammarong, N.1    Zhang, J.Z.2    Ortner, P.B.3
  • 144
    • 77955723296 scopus 로고    scopus 로고
    • Amultiple processing hybrid flow system for analysis of formaldehyde contamination in food
    • Teerasong S, Amornthammarong N, GrudpanK, Teshima N, SakaiT, et al. 2010. Amultiple processing hybrid flow system for analysis of formaldehyde contamination in food. Anal. Sci. 26:629-33
    • (2010) Anal. Sci. , vol.26 , pp. 629-633
    • Teerasong, S.1    Amornthammarong, N.2    Grudpan, K.3    Teshima, N.4    Sakai, T.5
  • 145
    • 84859436488 scopus 로고    scopus 로고
    • Compact optoelectronic flow-through device for fluorometric determination of calcium ions
    • Pokrzywnicka M, Fiedoruk M, Koncki R. 2012. Compact optoelectronic flow-through device for fluorometric determination of calcium ions. Talanta 93:106-10
    • (2012) Talanta , vol.93 , pp. 106-110
    • Pokrzywnicka, M.1    Fiedoruk, M.2    Koncki, R.3
  • 146
    • 0032641508 scopus 로고    scopus 로고
    • Fluorescence measurements with liquid core waveguide
    • Lacki P, Nowakowski A, Dress P, Franke H. 1999. Fluorescence measurements with liquid core waveguide. Proc. SPIE 3730:112-17
    • (1999) Proc. SPIE , vol.3730 , pp. 112-117
    • Lacki, P.1    Nowakowski, A.2    Dress, P.3    Franke, H.4
  • 148
    • 84880045404 scopus 로고    scopus 로고
    • Nephelometry and turbidimetry with paired emitter detector diodes and their application for determination of total urinary protein
    • Strzelak K, Koncki R. 2013. Nephelometry and turbidimetry with paired emitter detector diodes and their application for determination of total urinary protein. Anal. Chim. Acta 788:68-73
    • (2013) Anal. Chim. Acta , vol.788 , pp. 68-73
    • Strzelak, K.1    Koncki, R.2
  • 149
    • 84864976035 scopus 로고    scopus 로고
    • A simple colorimetric device for rapid detection of Hg2+ in water
    • Ye TX, He CY, Qu YQ, Deng Z, Jiang YQ, et al. 2012. A simple colorimetric device for rapid detection of Hg2+ in water. Analyst 137:4131-34
    • (2012) Analyst , vol.137 , pp. 4131-4134
    • Ye, T.X.1    He, C.Y.2    Qu, Y.Q.3    Deng, Z.4    Jiang, Y.Q.5
  • 150
    • 84872028434 scopus 로고    scopus 로고
    • Reusable light-emitting-diode induced chemiluminescence aptasensor for highly sensitive and selective detection of riboflavin
    • Xu SX, Zhang XF, Liu WW, Sun YH, Zhang HL. 2013. Reusable light-emitting-diode induced chemiluminescence aptasensor for highly sensitive and selective detection of riboflavin. Biosens. Bioelectron. 43:160-64
    • (2013) Biosens. Bioelectron. , vol.43 , pp. 160-164
    • Xu, S.X.1    Zhang, X.F.2    Liu, W.W.3    Sun, Y.H.4    Zhang, H.L.5
  • 151
    • 0037355047 scopus 로고    scopus 로고
    • Pulsed excitation source multiplexed fluorometry for the simultaneous measurement of multiple analytes. Continuous measurement of atmospheric hydrogen peroxide and methyl hydroperoxide
    • DOI 10.1021/ac026234d
    • Li J, Dasgupta PK, Tarver GA. 2003. Pulsed excitation source multiplexed fluorometry for the simultaneous measurement of multiple analytes. Continuous measurement of atmospheric hydrogen peroxide and methyl hydroperoxide. Anal. Chem. 75:1203-10 (Pubitemid 36402651)
    • (2003) Analytical Chemistry , vol.75 , Issue.5 , pp. 1203-1210
    • Li, J.1    Dasgupta, P.K.2    Tarver, G.A.3
  • 152
    • 0035884162 scopus 로고    scopus 로고
    • A miniaturized liquid core waveguide-capillary electrophoresis system with flow injection sample introduction and fluorometric detection using light-emitting diodes
    • DOI 10.1021/ac010341a
    • Wang SL, Huang XJ, Fang ZL, Dasgupta PK. 2001. A miniaturized liquid core waveguide-capillary electrophoresis system with flow injection sample introduction and fluorometric detection using lightemitting diodes. Anal. Chem. 73:4545-49 (Pubitemid 32868258)
    • (2001) Analytical Chemistry , vol.73 , Issue.18 , pp. 4545-4549
    • Wang, S.-L.1    Huang, X.-J.2    Fang, Z.-L.3    Dasgupta, P.K.4
  • 153
    • 23944469238 scopus 로고    scopus 로고
    • Integrating functional components into capillary electrophoresis systems using liquid-core waveguides
    • Wang SL, Fang ZL. 2005. Integrating functional components into capillary electrophoresis systems using liquid-core waveguides. Anal. Bioanal. Chem. 382:1747-50
    • (2005) Anal. Bioanal. Chem. , vol.382 , pp. 1747-1750
    • Wang, S.L.1    Fang, Z.L.2
  • 154
    • 54349110854 scopus 로고    scopus 로고
    • Capillary scale liquid core waveguide based fluorescence detectors for liquid chromatography and flow analysis
    • Song G, Villanueva-Fierro I, Ohira SI, Mishra S, Bailiff H, et al. 2008. Capillary scale liquid core waveguide based fluorescence detectors for liquid chromatography and flow analysis. Talanta 77:901-8
    • (2008) Talanta , vol.77 , pp. 901-908
    • Song, G.1    Villanueva-Fierro, I.2    Ohira, S.I.3    Mishra, S.4    Bailiff, H.5
  • 155
    • 61449259764 scopus 로고    scopus 로고
    • Separation of tyrosine enantiomer derivatives by capillary electrophoresis with light-emitting diode-induced fluorescence detection
    • BiWW, Lei SR, Yang XP, XuZM, Yuan HY, et al. 2009. Separation of tyrosine enantiomer derivatives by capillary electrophoresis with light-emitting diode-induced fluorescence detection. Talanta 78:1167-72
    • (2009) Talanta , vol.78 , pp. 1167-1172
    • Bi, W.W.1    Lei, S.R.2    Yang, X.P.3    Xu, Z.M.4    Yuan, H.Y.5
  • 156
    • 69449104829 scopus 로고    scopus 로고
    • Light-emitting-diode-induced chemiluminescence detection for capillary electrophoresis
    • Zhang XF, Zhang JY, Wu X, Lv Y, Hou XD. 2009. Light-emitting-diode- induced chemiluminescence detection for capillary electrophoresis. Electrophoresis 30:1937-42
    • (2009) Electrophoresis , vol.30 , pp. 1937-1942
    • Zhang, X.F.1    Zhang, J.Y.2    Wu, X.3    Lv, Y.4    Hou, X.D.5
  • 157
    • 61449157633 scopus 로고    scopus 로고
    • A low-cost light-emitting diode induced fluorescence detector for capillary electrophoresis based on an orthogonal optical arrangement
    • Yang FB, Pan JZ, Zhang T, Fang Q. 2009. A low-cost light-emitting diode induced fluorescence detector for capillary electrophoresis based on an orthogonal optical arrangement. Talanta 78:1155-58
    • (2009) Talanta , vol.78 , pp. 1155-1158
    • Yang, F.B.1    Pan, J.Z.2    Zhang, T.3    Fang, Q.4
  • 158
    • 77954965546 scopus 로고    scopus 로고
    • Multi-wavelength light emitting diode array as an excitation source for light emitting diode-induced fluorescence detection in capillary electrophoresis
    • Huo F, Yuan HY, Breadmore MC, Xiao D. 2010. Multi-wavelength light emitting diode array as an excitation source for light emitting diode-induced fluorescence detection in capillary electrophoresis. Electrophoresis 31:2589-95
    • (2010) Electrophoresis , vol.31 , pp. 2589-2595
    • Huo, F.1    Yuan, H.Y.2    Breadmore, M.C.3    Xiao, D.4
  • 159
    • 72949091719 scopus 로고    scopus 로고
    • Analysis of amino acids and biogenic amines in breast cancer cells by capillary electrophoresis using polymer solutions containing sodium dodecyl sulfate
    • Kao YY, Liu KT, HuangMF, Chiu TC, Chang HT. 2010. Analysis of amino acids and biogenic amines in breast cancer cells by capillary electrophoresis using polymer solutions containing sodium dodecyl sulfate. J. Chromatogr. A 1217:582-87
    • (2010) J. Chromatogr. A , vol.1217 , pp. 582-587
    • Kao, Y.Y.1    Liu, K.T.2    Huang, M.F.3    Chiu, T.C.4    Chang, H.T.5
  • 160
    • 84904368743 scopus 로고    scopus 로고
    • Determination of IgG by capillary electrophoresis with optical fiber light-emitting diode induced fluorescence detection
    • Gan J, Zhang D, Luo YP, Hu J, Huang DQ. 2010. Determination of IgG by capillary electrophoresis with optical fiber light-emitting diode induced fluorescence detection. Fenxi Ceshi Xuebao 29:257-61
    • (2010) Fenxi Ceshi Xuebao , vol.29 , pp. 257-261
    • Gan, J.1    Zhang, D.2    Luo, Y.P.3    Hu, J.4    Huang, D.Q.5
  • 161
    • 84904306507 scopus 로고    scopus 로고
    • Determination of epinephrine and dopamine by capillary electrophoresis with optical fiber light-emitting diode induced fluorescence detection
    • Gan J, Zhao SL, Wang SC, Wan XZ, Hu J. 2010. Determination of epinephrine and dopamine by capillary electrophoresis with optical fiber light-emitting diode induced fluorescence detection. Fenxi Shiyanshi 29:93-97
    • (2010) Fenxi Shiyanshi , vol.29 , pp. 93-97
    • Gan, J.1    Zhao, S.L.2    Wang, S.C.3    Wan, X.Z.4    Hu, J.5
  • 162
    • 79961129012 scopus 로고    scopus 로고
    • A simple and sensitive CE method for the simultaneous determination of catecholamines in urine with in-column optical fiber light-emitting diode-induced fluorescence detection
    • Diao PY, Yuan HY, Huo F, Chen LF, Xiao D, et al. 2011. A simple and sensitive CE method for the simultaneous determination of catecholamines in urine with in-column optical fiber light-emitting diode-induced fluorescence detection. Talanta 85:1279-84
    • (2011) Talanta , vol.85 , pp. 1279-1284
    • Diao, P.Y.1    Yuan, H.Y.2    Huo, F.3    Chen, L.F.4    Xiao, D.5
  • 163
    • 79956095884 scopus 로고    scopus 로고
    • Dual wavelength excitation fluorescence detector for capillary electrophoresis using a pulsed bi-colour light emitting diode
    • Huo F, Guijt R, Xiao D, Breadmore MC. 2011. Dual wavelength excitation fluorescence detector for capillary electrophoresis using a pulsed bi-colour light emitting diode. Analyst 136:2234-41
    • (2011) Analyst , vol.136 , pp. 2234-2241
    • Huo, F.1    Guijt, R.2    Xiao, D.3    Breadmore, M.C.4
  • 164
    • 84904360670 scopus 로고    scopus 로고
    • Determination of ephedrine and pseudoephedrine in Ephedra herb by capillary electrophoresis/LED induced fluorescence detector
    • Xu J, Li J, Hu Q, Chen R, Li Y, Cao JJ. 2012. Determination of ephedrine and pseudoephedrine in Ephedra herb by capillary electrophoresis/LED induced fluorescence detector. Fenxi Ceshi Xuebao 31:977-81
    • (2012) Fenxi Ceshi Xuebao , vol.31 , pp. 977-981
    • Xu, J.1    Li, J.2    Hu, Q.3    Chen, R.4    Li, Y.5    Cao, J.J.6
  • 165
    • 84860283387 scopus 로고    scopus 로고
    • Determination of RNA degradation by capillary electrophoresis with cyan light-emitted diode-induced fluorescence
    • Yang TH, Chang PL. 2012. Determination of RNA degradation by capillary electrophoresis with cyan light-emitted diode-induced fluorescence. J. Chromatogr. A 1239:78-84
    • (2012) J. Chromatogr. A , vol.1239 , pp. 78-84
    • Yang, T.H.1    Chang, P.L.2
  • 166
    • 84855930365 scopus 로고    scopus 로고
    • A compact and highly sensitive light-emitting diode-induced fluorescence detector for capillary flow systems
    • Geng XH, Wu DP, Guan YF. 2012. A compact and highly sensitive light-emitting diode-induced fluorescence detector for capillary flow systems. Talanta 88:463-67
    • (2012) Talanta , vol.88 , pp. 463-467
    • Geng, X.H.1    Wu, D.P.2    Guan, Y.F.3
  • 167
    • 84875512696 scopus 로고    scopus 로고
    • Ultrafast haplotyping of putative microRNA-binding sites in the WFS1 gene by multiplex polymerase chain reaction and capillary gel electrophoresis
    • Kerekgyarto M, Nemeth N, Kerekes T, Ronai Z, Guttman A. 2013. Ultrafast haplotyping of putative microRNA-binding sites in the WFS1 gene by multiplex polymerase chain reaction and capillary gel electrophoresis. J. Chromatogr. A 1286:229-34
    • (2013) J. Chromatogr. A , vol.1286 , pp. 229-234
    • Kerekgyarto, M.1    Nemeth, N.2    Kerekes, T.3    Ronai, Z.4    Guttman, A.5
  • 168
    • 79955523196 scopus 로고    scopus 로고
    • A facile light-emitting-diode induced fluorescence detector coupled to an integrated microfluidic device formicrochip electrophoresis
    • Yang F, Li XC, Zhang W, Pan JB, Chen ZG. 2011. A facile light-emitting-diode induced fluorescence detector coupled to an integrated microfluidic device formicrochip electrophoresis. Talanta 84:1099-106
    • (2011) Talanta , vol.84 , pp. 1099-1106
    • Yang, F.1    Li, X.C.2    Zhang, W.3    Pan, J.B.4    Chen, Z.G.5
  • 169
    • 84867996067 scopus 로고    scopus 로고
    • Rapid determination of creatinine in human urine by microchip electrophoresis with LED induced fluorescence detection
    • Wang SP, Li XC, Yang JP, Yang XJ, Hou FH, Chen Z. 2012. Rapid determination of creatinine in human urine by microchip electrophoresis with LED induced fluorescence detection. Chromatographia 75:1287-93
    • (2012) Chromatographia , vol.75 , pp. 1287-1293
    • Wang, S.P.1    Li, X.C.2    Yang, J.P.3    Yang, X.J.4    Hou, F.H.5    Chen, Z.6
  • 170
    • 84879785617 scopus 로고    scopus 로고
    • Determination of sulfonamides in pharmaceuticals and rabbit plasma by microchip electrophoresis with LED-IF detection
    • Zhang BB, Chen ZG, Yu YY, Yang JP, Pan JB. 2013. Determination of sulfonamides in pharmaceuticals and rabbit plasma by microchip electrophoresis with LED-IF detection. Chromatographia 76:821-29
    • (2013) Chromatographia , vol.76 , pp. 821-829
    • Zhang, B.B.1    Chen, Z.G.2    Yu, Y.Y.3    Yang, J.P.4    Pan, J.B.5
  • 171
    • 78449248586 scopus 로고    scopus 로고
    • Chip-based CE for rapid separation of 8-aminopyrene-1,3, 6-trisulfonic acid (APTS) derivatized glycans
    • Smejkal P, Szekrenyes A , Ryvolova M, Foret F, Guttman A, et al. 2010. Chip-based CE for rapid separation of 8-aminopyrene-1, 3, 6-trisulfonic acid (APTS) derivatized glycans. Electrophoresis 31:3783-86
    • (2010) Electrophoresis , vol.31 , pp. 3783-3786
    • Smejkal, P.1    Szekrenyes, A.2    Ryvolova, M.3    Foret, F.4    Guttman, A.5
  • 172
    • 84875540852 scopus 로고    scopus 로고
    • Exploring chip-capillary electrophoresis-laser-induced fluorescence field-deployable platform flexibility: Separations of fluorescent dyes by chip-based non-aqueous capillary electrophoresis
    • Nuchtavorn N, Smejkal P, Breadmore MC, Guijt RM, Doble P, et al. 2013. Exploring chip-capillary electrophoresis-laser-induced fluorescence field-deployable platform flexibility: separations of fluorescent dyes by chip-based non-aqueous capillary electrophoresis. J. Chromatogr. A 1286:216-21
    • (2013) J. Chromatogr. A , vol.1286 , pp. 216-221
    • Nuchtavorn, N.1    Smejkal, P.2    Breadmore, M.C.3    Guijt, R.M.4    Doble, P.5
  • 173
    • 84869089754 scopus 로고    scopus 로고
    • Separation of carboxylic acids in human serum by isotachophoresis using a commercial field-deployable analytical platform combined with in-house glass microfluidic chips
    • Smejkal P, Breadmore MC, Guijt RM, Grym J, Foret F, et al. 2012. Separation of carboxylic acids in human serum by isotachophoresis using a
    • (2012) Anal. Chim. Acta , vol.755 , pp. 115-120
    • Smejkal, P.1    Breadmore, M.C.2    Guijt, R.M.3    Grym, J.4    Foret, F.5
  • 174
    • 84868020751 scopus 로고    scopus 로고
    • Isotachophoresis on a chip with indirect fluorescence detection as a field deployable system for analysis of carboxylic acids
    • Smejkal P, Breadmore MC, Guijt RM, Foret F, Bek F, MackaM. 2012. Isotachophoresis on a chip with indirect fluorescence detection as a field deployable system for analysis of carboxylic acids. Electrophoresis 33:3166-72
    • (2012) Electrophoresis , vol.33 , pp. 3166-3172
    • Smejkal, P.1    Breadmore, M.C.2    Guijt, R.M.3    Foret, F.4    Bek, F.5    Macka, M.6
  • 175
    • 84887403293 scopus 로고    scopus 로고
    • Analytical isotachophoresis of lactate in human serum using dry film photoresist microfluidic chips compatible with a commercially available field-deployable instrument platform
    • Smejkal P, Breadmore MC, Guijt RM, Foret F, Bek F, Macka M. 2013. Analytical isotachophoresis of lactate in human serum using dry film photoresist microfluidic chips compatible with a commercially available field-deployable instrument platform. Anal. Chim. Acta 803:135-42
    • (2013) Anal. Chim. Acta , vol.803 , pp. 135-142
    • Smejkal, P.1    Breadmore, M.C.2    Guijt, R.M.3    Foret, F.4    Bek, F.5    Macka, M.6
  • 176
    • 84922687557 scopus 로고    scopus 로고
    • Development of an LED-induced fluorescence analysis system using a compact disk-typemicrofluidic device and its application to enzymelinked immunosorbent assay
    • Morioka K, Nakajima H, Hemmi A, Zeng HL, Uchiyama K. 2013. Development of an LED-induced fluorescence analysis system using a compact disk-typemicrofluidic device and its application to enzymelinked immunosorbent assay. Bunseki Kagaku 62:65-71
    • (2013) Bunseki Kagaku , vol.62 , pp. 65-71
    • Morioka, K.1    Nakajima, H.2    Hemmi, A.3    Zeng, H.L.4    Uchiyama, K.5
  • 178
    • 84866008018 scopus 로고    scopus 로고
    • Light-emitting diode induced fluorescence (LED-IF) detection design for a pen-shaped cartridge based single capillary electrophoresis system
    • Kerekgyarto M, Kerekes T, Tsai E, Amirkhanian VD, Guttman A. 2012. Light-emitting diode induced fluorescence (LED-IF) detection design for a pen-shaped cartridge based single capillary electrophoresis system. Electrophoresis 33:2752-58
    • (2012) Electrophoresis , vol.33 , pp. 2752-2758
    • Kerekgyarto, M.1    Kerekes, T.2    Tsai, E.3    Amirkhanian, V.D.4    Guttman, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.