메뉴 건너뛰기




Volumn 202, Issue , 2014, Pages 1200-1208

Novel superparamagnetic PFu@Fe3O4 conductive nanocomposite as a suitable host for hemoglobin immobilization

Author keywords

Biosensor; Hemoglobin; Hydrogen peroxide; Nanocomposite

Indexed keywords

BIOCOMPATIBILITY; FIELD EMISSION MICROSCOPES; HEMOGLOBIN; HYDROGEN PEROXIDE; NANOCOMPOSITES; PEROXIDES; RATE CONSTANTS; SUPERPARAMAGNETISM; SYNTHESIS (CHEMICAL); X RAY DIFFRACTION;

EID: 84903973458     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2014.06.019     Document Type: Article
Times cited : (64)

References (49)
  • 1
    • 0035822871 scopus 로고    scopus 로고
    • Synthesis and characterization of novel film-forming vinyl polymer/silica colloidal nanocomposites
    • DOI 10.1021/la010138a
    • J.I. Amalvy, M.J. Percy, S.P. Armes, and H. Wiese Synthesis and characterization of novel film-forming vinyl polymer/silica colloidal nanocomposites Langmuir 17 2001 4770 4778 (Pubitemid 35330196)
    • (2001) Langmuir , vol.17 , Issue.16 , pp. 4770-4778
    • Amalvy, J.I.1    Percy, M.J.2    Armes, S.P.3    Wiese, H.4
  • 2
    • 0142027907 scopus 로고    scopus 로고
    • Electrochemical study of methylene blue incorporated into mordenite type zeolite and its application for amperometric determination of ascorbic acid in real samples
    • DOI 10.1016/S0003-2670(03)00790-6
    • M. Arvand, S. Sohrabnezhad, M.F. Mousavi, M. Shamsipur, and M.A. Zanjanchi Electrochemical study of methylene blue incorporated into mordenite type zeolite and its application for amperometric determination of ascorbic acid in real samples Anal. Chim. Acta 491 2003 193 201 (Pubitemid 37297779)
    • (2003) Analytica Chimica Acta , vol.491 , Issue.2 , pp. 193-201
    • Arvand, M.1    Sohrabnezhad, Sh.2    Mousavi, M.F.3    Shamsipur, M.4    Zanjanchi, M.A.5
  • 3
    • 84865754591 scopus 로고    scopus 로고
    • Biomimetic sensor for certain catecholamines employing copper (II) complex and silver nanoparticle modified glassy carbon paste electrode
    • B.J. Sanghavi, S.M. Mobin, P. Mathur, G.K. Lahiri, and A.K. Srivastava Biomimetic sensor for certain catecholamines employing copper (II) complex and silver nanoparticle modified glassy carbon paste electrode Biosens. Bioelectron. 39 2013 124 132
    • (2013) Biosens. Bioelectron. , vol.39 , pp. 124-132
    • Sanghavi, B.J.1    Mobin, S.M.2    Mathur, P.3    Lahiri, G.K.4    Srivastava, A.K.5
  • 4
    • 78049244463 scopus 로고    scopus 로고
    • Simultaneous voltammetric determination of acetaminophen, aspirin and caffeine using an in situ surfactant-modified multiwalled carbon nanotube paste electrode
    • B.J. Sanghavi, and A.K. Srivastava Simultaneous voltammetric determination of acetaminophen, aspirin and caffeine using an in situ surfactant-modified multiwalled carbon nanotube paste electrode Electrochim. Acta 55 2010 8638 8648
    • (2010) Electrochim. Acta , vol.55 , pp. 8638-8648
    • Sanghavi, B.J.1    Srivastava, A.K.2
  • 5
    • 0030578871 scopus 로고    scopus 로고
    • Peroxidase-modified electrodes: Fundamentals and application
    • DOI 10.1016/0003-2670(96)00169-9
    • T. Ruzgas, E. Csoregi, J. Emneus, and L. Gorton Peroxidase-modified electrodes: fundamentals and application Anal. Chim. Acta 330 1996 123 138 (Pubitemid 26294813)
    • (1996) Analytica Chimica Acta , vol.330 , Issue.2-3 , pp. 123-138
    • Ruzgas, T.1    Csoregi, E.2    Emneus, J.3    Gorton, L.4    Marko-Varga, G.5
  • 6
    • 1042267396 scopus 로고    scopus 로고
    • A novel hydrogen peroxide sensor based on horseradish peroxidase immobilized on colloidal Au modified ITO electrode
    • L. Wang A novel hydrogen peroxide sensor based on horseradish peroxidase immobilized on colloidal Au modified ITO electrode Electrochem. Commun. 6 2004 225 229
    • (2004) Electrochem. Commun. , vol.6 , pp. 225-229
    • Wang, L.1
  • 7
    • 51849096758 scopus 로고    scopus 로고
    • Spectrophotometric determination of hydrogen peroxide in water and cream samples
    • K. Sunil, and B. Narayana Spectrophotometric determination of hydrogen peroxide in water and cream samples Bull. Environ. Contam. Toxicol. 81 2008 422 426
    • (2008) Bull. Environ. Contam. Toxicol. , vol.81 , pp. 422-426
    • Sunil, K.1    Narayana, B.2
  • 8
    • 5644236659 scopus 로고    scopus 로고
    • Complexities in horseradish peroxidase-catalyzed oxidation of dihydroxyphenoxazine derivatives: Appropriate ranges for pH values and hydrogen peroxide concentrations in quantitative analysis
    • DOI 10.1016/j.ab.2004.07.037, PII S0003269704006499
    • V. Towne, M. Will, B. Oswald, and Q. Zhao Complexities in horseradish peroxidase-catalyzed oxidation of dihydroxyphenoxazine derivatives: appropriate ranges for pH values and hydrogen peroxide concentrations in quantitative analysis Anal. Biochem. 334 2004 290 296 (Pubitemid 39370964)
    • (2004) Analytical Biochemistry , vol.334 , Issue.2 , pp. 290-296
    • Towne, V.1    Will, M.2    Oswald, B.3    Zhao, Q.4
  • 9
    • 33947609932 scopus 로고    scopus 로고
    • A coulometric biosensor to determine hydrogen peroxide using a monomolecular layer of horseradish peroxidase immobilized on a glass surface
    • DOI 10.1016/j.bios.2006.11.007, PII S095656630600546X
    • F. Vianello, L. Zennaro, and A. Rigo A coulometric biosensor to determine hydrogen peroxide using a monomolecular layer of horseradish peroxidase immobilized on a glass surface Biosens. Bioelectron. 22 2007 2694 2699 (Pubitemid 46484267)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.11 , pp. 2694-2699
    • Vianello, F.1    Zennaro, L.2    Rigo, A.3
  • 10
    • 82555181619 scopus 로고    scopus 로고
    • Recent advances in electrochemical sensing for hydrogen peroxide: A review
    • W. Chen, S. Cai, Q.-Q. Ren, W. Wen, and Y.-D. Zhao Recent advances in electrochemical sensing for hydrogen peroxide: a review Analyst 137 2012 49 58
    • (2012) Analyst , vol.137 , pp. 49-58
    • Chen, W.1    Cai, S.2    Ren, Q.-Q.3    Wen, W.4    Zhao, Y.-D.5
  • 11
    • 4043114793 scopus 로고    scopus 로고
    • A superoxide sensor based on a multilayer cytochrome c electrode
    • DOI 10.1021/ac049738f
    • M.K. Beissenhirtz, F.W. Scheller, and F. Lisdat A superoxide sensor based on a multilayer cytochrome c electrode Anal. Chem. 76 2004 4665 4671 (Pubitemid 39079460)
    • (2004) Analytical Chemistry , vol.76 , Issue.16 , pp. 4665-4671
    • Beissenhirtz, M.K.1    Scheller, F.W.2    Lisdat, F.3
  • 12
    • 0037426368 scopus 로고    scopus 로고
    • Peptide-protein interactions: Photoinduced electron-transfer within the preformed and encounter complexes of a designed metallopeptide and cytochrome c
    • DOI 10.1021/bi027055t
    • R.C. Lasey, L. Liu, L. Zang, and M.Y. Ogawa Peptide-protein interactions: photoinduced electron-transfer within the preformed and encounter complexes of a designed metallopeptide and cytochrome c Biochemistry 42 2003 3904 3910 (Pubitemid 36402683)
    • (2003) Biochemistry , vol.42 , Issue.13 , pp. 3904-3910
    • Lasey, R.C.1    Liu, L.2    Zang, L.3    Ogawa, M.Y.4
  • 14
    • 49049113124 scopus 로고    scopus 로고
    • Electrochemical glucose sensors and their applications in diabetes management
    • A. Heller, and B. Feldman Electrochemical glucose sensors and their applications in diabetes management Chem. Rev. 108 2008 2482 2505
    • (2008) Chem. Rev. , vol.108 , pp. 2482-2505
    • Heller, A.1    Feldman, B.2
  • 15
    • 0032646986 scopus 로고    scopus 로고
    • Ordered electrochemically active films of hemoglobin, didodecyldimethylammonium ions, and clay
    • X. Chen, N. Hu, Y. Zeng, J.F. Rusling, and J. Yang Ordered electrochemically active films of hemoglobin, didodecyldimethylammonium ions, and clay Langmuir 15 1999 7022 7030
    • (1999) Langmuir , vol.15 , pp. 7022-7030
    • Chen, X.1    Hu, N.2    Zeng, Y.3    Rusling, J.F.4    Yang, J.5
  • 16
    • 34250201784 scopus 로고    scopus 로고
    • Direct electrochemistry and electrocatalysis of hemoglobin immobilized in bimodal mesoporous silica and chitosan inorganic-organic hybrid film
    • DOI 10.1016/j.elecom.2007.02.015, PII S1388248107000756
    • L. Zhang, Q. Zhang, and J. Li Direct electrochemistry and electrocatalysis of hemoglobin immobilized in bimodal mesoporous silica and chitosan inorganic-organic hybrid film Electrochem. Commun. 9 2007 1530 1535 (Pubitemid 46907750)
    • (2007) Electrochemistry Communications , vol.9 , Issue.7 , pp. 1530-1535
    • Zhang, L.1    Zhang, Q.2    Li, J.3
  • 17
    • 0035199788 scopus 로고    scopus 로고
    • The direct electrochemistry of myoglobin at a DL-homocysteine self-assembled gold electrode
    • H. Zhang, and N. Li The direct electrochemistry of myoglobin at a DL-homocysteine self-assembled gold electrode Bioelectrochemistry 53 2000 97 101
    • (2000) Bioelectrochemistry , vol.53 , pp. 97-101
    • Zhang, H.1    Li, N.2
  • 19
    • 84883472003 scopus 로고    scopus 로고
    • Real-time electrochemical monitoring of adenosine triphosphate in the picomolar to micromolar range using graphene-modified electrodes
    • B.J. Sanghavi, S. Sitaula, M.H. Griep, S.P. Karna, M.F. Ali, and N.S. Swami Real-time electrochemical monitoring of adenosine triphosphate in the picomolar to micromolar range using graphene-modified electrodes Anal. Chem. 85 2013 8158 8165
    • (2013) Anal. Chem. , vol.85 , pp. 8158-8165
    • Sanghavi, B.J.1    Sitaula, S.2    Griep, M.H.3    Karna, S.P.4    Ali, M.F.5    Swami, N.S.6
  • 20
    • 84899788551 scopus 로고    scopus 로고
    • Electrokinetic preconcentration and detection of neuropeptides at patterned graphene-modified electrodes in a nanochannel
    • B.J. Sanghavi, W. Varhue, J.L. Chavez, C.-F. Chou, and N.S. Swami Electrokinetic preconcentration and detection of neuropeptides at patterned graphene-modified electrodes in a nanochannel Anal. Chem. 86 2014 4120 4125
    • (2014) Anal. Chem. , vol.86 , pp. 4120-4125
    • Sanghavi, B.J.1    Varhue, W.2    Chavez, J.L.3    Chou, C.-F.4    Swami, N.S.5
  • 21
    • 68949180089 scopus 로고    scopus 로고
    • Palladium nanoclusters-coated polyfuran as a novel sensor for catecholamine neurotransmitters and paracetamol
    • N.F. Atta, M.F. El-Kady, and A. Galal Palladium nanoclusters-coated polyfuran as a novel sensor for catecholamine neurotransmitters and paracetamol Sens. Actuators B 141 2009 566 574
    • (2009) Sens. Actuators B , vol.141 , pp. 566-574
    • Atta, N.F.1    El-Kady, M.F.2    Galal, A.3
  • 22
    • 79954573777 scopus 로고    scopus 로고
    • 2 nanoparticles and their application to the highly effective immobilization of myoglobin for direct electrochemistry
    • 2 nanoparticles and their application to the highly effective immobilization of myoglobin for direct electrochemistry Electrochim. Acta 56 2011 4231 4236
    • (2011) Electrochim. Acta , vol.56 , pp. 4231-4236
    • Peng, H.1    Liang, R.2    Zhang, L.3    Qiu, J.4
  • 26
    • 84864920149 scopus 로고    scopus 로고
    • 4NPs/cMWCNT/PANI/Au electrode for determination of phenolic content in tea leaves extract
    • 4NPs/cMWCNT/PANI/Au electrode for determination of phenolic content in tea leaves extract Enzyme Microb. Technol. 51 2012 179 185
    • (2012) Enzyme Microb. Technol. , vol.51 , pp. 179-185
    • Rawal, R.1    Chawla, S.2    Devender3    Pundir, C.S.4
  • 27
    • 79551546322 scopus 로고    scopus 로고
    • Magnetite-graphene for the direct electrochemistry of hemoglobin and its biosensing application
    • Y. He, Q. Sheng, J. Zheng, M. Wang, and B. Liu Magnetite-graphene for the direct electrochemistry of hemoglobin and its biosensing application Electrochim. Acta 56 2011 2471 2476
    • (2011) Electrochim. Acta , vol.56 , pp. 2471-2476
    • He, Y.1    Sheng, Q.2    Zheng, J.3    Wang, M.4    Liu, B.5
  • 28
    • 41949085082 scopus 로고    scopus 로고
    • Polyfuran conducting polymers: Synthesis, properties, and applications
    • M.J. González-Tejera, E.S. de la Blanca, and I. Carrillo Polyfuran conducting polymers: synthesis, properties, and applications Synth. Met. 158 2008 165 189
    • (2008) Synth. Met. , vol.158 , pp. 165-189
    • González-Tejera, M.J.1    De La Blanca, E.S.2    Carrillo, I.3
  • 29
    • 84903958608 scopus 로고    scopus 로고
    • Novel polyfuran/functionalized multiwalled carbon nanotubes composites with improved conductivity: Chemical synthesis, characterization, and antioxidant activity
    • E.N. Zare, M.M. Lakouraj, P.N. Moghadam, and R. Azimi Novel polyfuran/functionalized multiwalled carbon nanotubes composites with improved conductivity: chemical synthesis, characterization, and antioxidant activity Polym. Compos. 145 2013 299 310
    • (2013) Polym. Compos. , vol.145 , pp. 299-310
    • Zare, E.N.1    Lakouraj, M.M.2    Moghadam, P.N.3    Azimi, R.4
  • 30
    • 33750053889 scopus 로고    scopus 로고
    • Optimization of polymerization conditions of furan with aniline for variable conducting polymers
    • DOI 10.1021/cc060014m
    • X.-G. Li, Y. Kang, and M.-R. Huang Optimization of polymerization conditions of furan with aniline for variable conducting polymers J. Comb. Chem. 8 2006 670 678 (Pubitemid 44578623)
    • (2006) Journal of Combinatorial Chemistry , vol.8 , Issue.5 , pp. 670-678
    • Li, X.-G.1    Kang, Y.2    Huang, M.-R.3
  • 31
    • 84859426829 scopus 로고    scopus 로고
    • Modeling porosity of high surface area nanopowders of the gallium nitride GaN semiconductor
    • M. Drygas, and J.F. Janik Modeling porosity of high surface area nanopowders of the gallium nitride GaN semiconductor Mater. Chem. Phys. 133 2012 932 940
    • (2012) Mater. Chem. Phys. , vol.133 , pp. 932-940
    • Drygas, M.1    Janik, J.F.2
  • 32
    • 0018011730 scopus 로고
    • Measurements of particle size distribution parameters in ferrofluids
    • R. Chantrell, J. Popplewell, and S. Charles Measurements of particle size distribution parameters in ferrofluids IEEE Trans. Magn. 14 1978 975 977 (Pubitemid 9435995)
    • (1978) IEEE Trans Magn , vol.MAG-14 , Issue.5 , pp. 975-977
    • Chantrell, R.W.1    Popplewell, J.2    Charles, S.W.3
  • 33
    • 33748316663 scopus 로고    scopus 로고
    • Direct voltammetry and electrocatalytic properties of hemoglobin immobilized on a glassy carbon electrode modified with nickel oxide nanoparticles
    • DOI 10.1016/j.elecom.2006.06.017, PII S1388248106002529
    • A. Salimi, E. Sharifi, A. Noorbakhsh, and S. Soltanian Direct voltammetry and electrocatalytic properties of hemoglobin immobilized on a glassy carbon electrode modified with nickel oxide nanoparticles Electrochem. Commun. 8 2006 1499 1508 (Pubitemid 44331696)
    • (2006) Electrochemistry Communications , vol.8 , Issue.9 , pp. 1499-1508
    • Salimi, A.1    Sharifi, E.2    Noorbakhsh, A.3    Soltanian, S.4
  • 34
    • 84881304971 scopus 로고    scopus 로고
    • Direct electrochemistry and electrocatalysis of hemoglobin immobilized on biocompatible poly (styrene-alternative-maleic acid)/functionalized multi-wall carbon nanotubes blends
    • M. Baghayeri, E.N. Zare, and M. Namadchian Direct electrochemistry and electrocatalysis of hemoglobin immobilized on biocompatible poly (styrene-alternative-maleic acid)/functionalized multi-wall carbon nanotubes blends Sens. Actuators B 188 2013 227 234
    • (2013) Sens. Actuators B , vol.188 , pp. 227-234
    • Baghayeri, M.1    Zare, E.N.2    Namadchian, M.3
  • 35
  • 36
    • 84871646529 scopus 로고    scopus 로고
    • Synthesis of a conductive network of crosslinked carbon nanotube/hemoglobin on a thiol-modified Au surface and its application to biosensing
    • A.K.M. Kafi, and M.J. Crossley Synthesis of a conductive network of crosslinked carbon nanotube/hemoglobin on a thiol-modified Au surface and its application to biosensing Biosens. Bioelectron. 42 2013 273 279
    • (2013) Biosens. Bioelectron. , vol.42 , pp. 273-279
    • Kafi, A.K.M.1    Crossley, M.J.2
  • 37
    • 33645504413 scopus 로고    scopus 로고
    • Composite system based on chitosan and room-temperature ionic liquid: Direct electrochemistry and electrocatalysis of hemoglobin
    • X. Lu, J. Hu, X. Yao, Z. Wang, and J. Li Composite system based on chitosan and room-temperature ionic liquid: direct electrochemistry and electrocatalysis of hemoglobin Biomacromolecules 7 2006 975 980
    • (2006) Biomacromolecules , vol.7 , pp. 975-980
    • Lu, X.1    Hu, J.2    Yao, X.3    Wang, Z.4    Li, J.5
  • 38
    • 49249148639 scopus 로고
    • General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems
    • E. Laviron General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems J. Electroanal. Chem. 101 1979 19 28
    • (1979) J. Electroanal. Chem. , vol.101 , pp. 19-28
    • Laviron, E.1
  • 39
    • 34249071887 scopus 로고    scopus 로고
    • 6 modified carbon paste electrode
    • DOI 10.1021/jp067933n
    • 3 film on a new ionic liquid BPPF6 modified carbon paste electrode J. Phys. Chem. B 111 2007 4560 4567 (Pubitemid 46787653)
    • (2007) Journal of Physical Chemistry B , vol.111 , Issue.17 , pp. 4560-4567
    • Sun, W.1    Gao, R.2    Jiao, K.3
  • 41
    • 33846579141 scopus 로고    scopus 로고
    • Novel amperometric biosensor based on composite film assembled by polyelectrolyte-surfactant polymer, carbon nanotubes and hemoglobin
    • DOI 10.1016/j.snb.2006.04.067, PII S0925400506003364
    • L. Chen, and G. Lu Novel amperometric biosensor based on composite film assembled by polyelectrolyte-surfactant polymer, carbon nanotubes and hemoglobin Sens. Actuators B 121 2007 423 429 (Pubitemid 46186888)
    • (2007) Sensors and Actuators, B: Chemical , vol.121 , Issue.2 , pp. 423-429
    • Chen, L.1    Lu, G.2
  • 42
    • 58249132510 scopus 로고    scopus 로고
    • Comparative studies of interactions of hemoglobin with single-chain and with gemini surfactants
    • Y. Wang, R. Guo, and J. Xi Comparative studies of interactions of hemoglobin with single-chain and with gemini surfactants J. Colloid Interface Sci. 331 2009 470 475
    • (2009) J. Colloid Interface Sci. , vol.331 , pp. 470-475
    • Wang, Y.1    Guo, R.2    Xi, J.3
  • 43
    • 84861841380 scopus 로고    scopus 로고
    • Direct electrochemistry and electrocatalytic properties of hemoglobin immobilized on carbon nanotubes ionic liquid electrode
    • N. Moheimanian, J.B. Raoof, A. Safavi, and R. Ojani Direct electrochemistry and electrocatalytic properties of hemoglobin immobilized on carbon nanotubes ionic liquid electrode Electroanalysis 24 2012 1386 1393
    • (2012) Electroanalysis , vol.24 , pp. 1386-1393
    • Moheimanian, N.1    Raoof, J.B.2    Safavi, A.3    Ojani, R.4
  • 44
    • 84887480561 scopus 로고    scopus 로고
    • Direct electron transfer and electrocatalytic properties of immobilized hemoglobin onto glassy carbon electrode modified with ionic-liquid/titanium- nitride nanoparticles: Application to nitrite detection
    • S. Saadati, A. Salimi, R. Hallaj, and A. Rostami Direct electron transfer and electrocatalytic properties of immobilized hemoglobin onto glassy carbon electrode modified with ionic-liquid/titanium-nitride nanoparticles: application to nitrite detection Sens. Actuators B 191 2014 625 633
    • (2014) Sens. Actuators B , vol.191 , pp. 625-633
    • Saadati, S.1    Salimi, A.2    Hallaj, R.3    Rostami, A.4
  • 45
    • 0030579569 scopus 로고    scopus 로고
    • Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide
    • DOI 10.1016/S0003-2670(96)00337-6, PII S0003267096003376
    • J. Li, S.N. Tan, and H. Ge Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide Anal. Chim. Acta 335 1996 137 145 (Pubitemid 26402918)
    • (1996) Analytica Chimica Acta , vol.335 , Issue.1-2 , pp. 137-145
    • Li, J.1    Tan, S.N.2    Ge, H.3
  • 48
    • 84879582525 scopus 로고    scopus 로고
    • Fullerene-nitrogen doped carbon nanotubes for the direct electrochemistry of hemoglobin and its application in biosensing
    • Q. Sheng, R. Liu, and J. Zheng Fullerene-nitrogen doped carbon nanotubes for the direct electrochemistry of hemoglobin and its application in biosensing Bioelectrochemistry 94 2013 39 46
    • (2013) Bioelectrochemistry , vol.94 , pp. 39-46
    • Sheng, Q.1    Liu, R.2    Zheng, J.3
  • 49
    • 2342531063 scopus 로고    scopus 로고
    • Hydrogen peroxide biosensor based on direct electrochemistry of hemoglobin immobilized on carbon paste electrode by a silica sol-gel film
    • Q. Wang, G. Lu, and B. Yang Hydrogen peroxide biosensor based on direct electrochemistry of hemoglobin immobilized on carbon paste electrode by a silica sol-gel film Sens. Actuators B 99 2004 50 57
    • (2004) Sens. Actuators B , vol.99 , pp. 50-57
    • Wang, Q.1    Lu, G.2    Yang, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.