메뉴 건너뛰기




Volumn 98, Issue , 2014, Pages 379-386

Quantification of 2'-deoxy-2'-β-fluoro-4'-azidocytidine in rat and dog plasma using liquid chromatography-quadrupole time-of-flight and liquid chromatography-triple quadrupole mass spectrometry: Application to bioavailability and pharmacokinetic studies

Author keywords

2' Deoxy 2' fluoro 4' azidocytidine; Bioavailability; High performance liquid chromatography quadrupole time of flight mass spectrometry; High performance liquid chromatography triple quadrupole mass spectrometry; Pharmacokinetics

Indexed keywords

2' DEOXY 2' BETA FLUORO 4' AZIDOCYTIDINE; 4' AZIDOCYTIDINE; AMMONIUM ACETATE; FORMIC ACID; LAMIVUDINE; METHANOL; UNCLASSIFIED DRUG; 2'-DEOXY-2'-FLUORO-4'-AZIDOCYTIDINE; 4'-AZIDOCYTIDINE; CYTIDINE; DEOXYCYTIDINE;

EID: 84903829560     PISSN: 07317085     EISSN: 1873264X     Source Type: Journal    
DOI: 10.1016/j.jpba.2014.06.019     Document Type: Article
Times cited : (21)

References (21)
  • 1
    • 80052500137 scopus 로고    scopus 로고
    • Current nucleos(t)ide analogue therapy for chronic hepatitis B
    • Kim S.S., Cheong J.Y., Cho S.W. Current nucleos(t)ide analogue therapy for chronic hepatitis B. Gut Liver 2011, 5:278-287.
    • (2011) Gut Liver , vol.5 , pp. 278-287
    • Kim, S.S.1    Cheong, J.Y.2    Cho, S.W.3
  • 2
    • 73549089480 scopus 로고    scopus 로고
    • Current status and challenges of antiretroviral research and therapy
    • Este J.A., Cihlar T. Current status and challenges of antiretroviral research and therapy. Antivir. Res. 2010, 85:25-33.
    • (2010) Antivir. Res. , vol.85 , pp. 25-33
    • Este, J.A.1    Cihlar, T.2
  • 3
    • 84884257232 scopus 로고    scopus 로고
    • Treatment of hepatitis C virus infection in the future
    • Kanda T., Yokosuka O., Omata M. Treatment of hepatitis C virus infection in the future. Clin. Transl. Med. 2013, 2:9.
    • (2013) Clin. Transl. Med. , vol.2 , pp. 9
    • Kanda, T.1    Yokosuka, O.2    Omata, M.3
  • 4
    • 84903828851 scopus 로고    scopus 로고
    • Preparation of 2'-fluoro-4'-substituted nucleoside analogs as antiviral agents. Chinese Patent Application No: CN 2007-10137548, 20070807. Chinese Patent No: CN 101177442A, 20080514.
    • J. Chang, X. Bao, Q. Wang, X. Guo, W. Wang, X. Qi (2008) Preparation of 2'-fluoro-4'-substituted nucleoside analogs as antiviral agents. Chinese Patent Application No: CN 2007-10137548, 20070807. Chinese Patent No: CN 101177442A, 20080514.
    • (2008)
    • Chang, J.1    Bao, X.2    Wang, Q.3    Guo, X.4    Wang, W.5    Qi, X.6
  • 5
    • 84903830948 scopus 로고    scopus 로고
    • 2'-Fluoro-4'-substituted nucleosides, the preparation and use. International Application No: PCT/CN2008/001239, 20080627. International Patent No: WO2009009951, 20090122.
    • J. Chang (2009) 2'-Fluoro-4'-substituted nucleosides, the preparation and use. International Application No: PCT/CN2008/001239, 20080627. International Patent No: WO2009009951, 20090122.
    • (2009)
    • Chang, J.1
  • 6
    • 84903852514 scopus 로고    scopus 로고
    • 2'-Fluorine-4'-substituted nucleoside analogues, preparation methods and uses thereof. US Patent No: US 2010/0234584A1, 20100916.
    • J. Chang (2009) 2'-Fluorine-4'-substituted nucleoside analogues, preparation methods and uses thereof. US Patent No: US 2010/0234584A1, 20100916.
    • (2009)
    • Chang, J.1
  • 7
    • 84903829789 scopus 로고    scopus 로고
    • 2'-fluoro-4'-substituted nucleoside analogs and application. Chinese Patent Application No: CN 200910227556.3. Chinese Patent No: CN 201010506595X.
    • J. Chang, Q. Wang, Q. Wang (2010) 2'-fluoro-4'-substituted nucleoside analogs and application. Chinese Patent Application No: CN 200910227556.3. Chinese Patent No: CN 201010506595X.
    • (2010)
    • Chang, J.1    Wang, Q.2    Wang, Q.3
  • 9
    • 84871915422 scopus 로고    scopus 로고
    • Novel nucleoside analogue FNC is effective against both wild-type and lamivudine-resistant HBV clinical isolates
    • Zhou Y., Zhang Y., Yang X., Zhao J., Zheng L., Sun C., Jiang J., Yang Q., Wang Q., Chang J. Novel nucleoside analogue FNC is effective against both wild-type and lamivudine-resistant HBV clinical isolates. Antivir. Ther. 2012, 17:1593-1599.
    • (2012) Antivir. Ther. , vol.17 , pp. 1593-1599
    • Zhou, Y.1    Zhang, Y.2    Yang, X.3    Zhao, J.4    Zheng, L.5    Sun, C.6    Jiang, J.7    Yang, Q.8    Wang, Q.9    Chang, J.10
  • 13
    • 84875933666 scopus 로고    scopus 로고
    • Design, synthesis, and biological evaluation of new 2'-deoxy-2'-fluoro-4'-triazole cytidine nucleosides as potent antiviral agents
    • Wu J., Yu W., Fu L., He W., Wang Y., Chai B., Song C., Chang J. Design, synthesis, and biological evaluation of new 2'-deoxy-2'-fluoro-4'-triazole cytidine nucleosides as potent antiviral agents. Eur. J. Med. Chem. 2013, 63C:739-745.
    • (2013) Eur. J. Med. Chem. , vol.63 C , pp. 739-745
    • Wu, J.1    Yu, W.2    Fu, L.3    He, W.4    Wang, Y.5    Chai, B.6    Song, C.7    Chang, J.8
  • 14
    • 42649088073 scopus 로고    scopus 로고
    • Performance optimisation of a new-generation orthogonal-acceleration quadrupole-time-of-flight mass spectrometer
    • Bristow T., Constantine J., Harrison M., Cavoit F. Performance optimisation of a new-generation orthogonal-acceleration quadrupole-time-of-flight mass spectrometer. Rapid Commun. Mass Spectrom. 2008, 22:1213-1222.
    • (2008) Rapid Commun. Mass Spectrom. , vol.22 , pp. 1213-1222
    • Bristow, T.1    Constantine, J.2    Harrison, M.3    Cavoit, F.4
  • 15
    • 84858427546 scopus 로고    scopus 로고
    • Using high-resolution quadrupole TOF technology in DMPK analyses
    • Campbell J.L., Le Blanc J.C. Using high-resolution quadrupole TOF technology in DMPK analyses. Bioanalysis 2012, 4:487-500.
    • (2012) Bioanalysis , vol.4 , pp. 487-500
    • Campbell, J.L.1    Le Blanc, J.C.2
  • 16
    • 79955522559 scopus 로고    scopus 로고
    • A discriminant based charge deconvolution analysis pipeline for protein profiling of whole cell extracts using liquid chromatography-electrospray ionization-quadrupole time-of-flight mass spectrometry
    • Lu W., Callahan J.H., Fry F.S., Andrzejewski D., Musser S.M., Harrington P.B. A discriminant based charge deconvolution analysis pipeline for protein profiling of whole cell extracts using liquid chromatography-electrospray ionization-quadrupole time-of-flight mass spectrometry. Talanta 2011, 84:1180-1187.
    • (2011) Talanta , vol.84 , pp. 1180-1187
    • Lu, W.1    Callahan, J.H.2    Fry, F.S.3    Andrzejewski, D.4    Musser, S.M.5    Harrington, P.B.6
  • 17
    • 45249094536 scopus 로고    scopus 로고
    • Exploring the precursor ion exclusion feature of liquid chromatography-electrospray ionization quadrupole time-of-flight mass spectrometry for improving protein identification in shotgun proteome analysis
    • Wang N., Li L. Exploring the precursor ion exclusion feature of liquid chromatography-electrospray ionization quadrupole time-of-flight mass spectrometry for improving protein identification in shotgun proteome analysis. Anal. Chem. 2008, 80:4696-4710.
    • (2008) Anal. Chem. , vol.80 , pp. 4696-4710
    • Wang, N.1    Li, L.2
  • 18
    • 84880582260 scopus 로고    scopus 로고
    • Simultaneous determination of tectorigenin and its metabolites in rat plasma by ultra performance liquid chromatography/quadrupole time-of-flight mass spectrometry
    • Wang S., Gong T., Lu J., Kano Y., Yuan D. Simultaneous determination of tectorigenin and its metabolites in rat plasma by ultra performance liquid chromatography/quadrupole time-of-flight mass spectrometry. J. Chromatogr. B 2013, 933:50-58.
    • (2013) J. Chromatogr. B , vol.933 , pp. 50-58
    • Wang, S.1    Gong, T.2    Lu, J.3    Kano, Y.4    Yuan, D.5
  • 19
    • 84874980102 scopus 로고    scopus 로고
    • Pharmacokinetics of 2,3,5,4'-tetrahydroxystilbene-2-O-beta-d-glucoside in rat using ultra-performance LC-quadrupole TOF-MS
    • Zhao Y.Y., Zhang L., Feng Y.L., Chen D.Q., Xi Z.H., Du X., Bai X., Lin R.C. Pharmacokinetics of 2,3,5,4'-tetrahydroxystilbene-2-O-beta-d-glucoside in rat using ultra-performance LC-quadrupole TOF-MS. J. Sep. Sci. 2013, 36:863-871.
    • (2013) J. Sep. Sci. , vol.36 , pp. 863-871
    • Zhao, Y.Y.1    Zhang, L.2    Feng, Y.L.3    Chen, D.Q.4    Xi, Z.H.5    Du, X.6    Bai, X.7    Lin, R.C.8
  • 20
    • 0003484310 scopus 로고    scopus 로고
    • US Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research, Rockville, MD
    • Guidance for Industry: Bioanalytical Method Validation 2001, US Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research, Rockville, MD.
    • (2001) Guidance for Industry: Bioanalytical Method Validation
  • 21
    • 34250655363 scopus 로고    scopus 로고
    • Development and validation of a reversed-phase liquid chromatographic method with fluorescence detection for the study of Saquinavir pharmacokinetics in rat plasma
    • Pathak S.M., Kumar A.R., Subramanian G., Udupa N. Development and validation of a reversed-phase liquid chromatographic method with fluorescence detection for the study of Saquinavir pharmacokinetics in rat plasma. Anal. Chim. Acta 2007, 594:248-256.
    • (2007) Anal. Chim. Acta , vol.594 , pp. 248-256
    • Pathak, S.M.1    Kumar, A.R.2    Subramanian, G.3    Udupa, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.