메뉴 건너뛰기




Volumn 21, Issue 4, 2014, Pages 251-256

Artificial pancreas: Fuzzy logic and control of glycemia

Author keywords

artificial pancreas; closed loop; low glucose suspend; MD Logic AP; overnight glucose control; type 1 diabetes

Indexed keywords

GLUCOSE; INSULIN; ANTIDIABETIC AGENT; GLUCOSE BLOOD LEVEL; GLYCOSYLATED HEMOGLOBIN; HEMOGLOBIN A1C PROTEIN, HUMAN;

EID: 84903817961     PISSN: 1752296X     EISSN: 17522978     Source Type: Journal    
DOI: 10.1097/MED.0000000000000073     Document Type: Review
Times cited : (30)

References (45)
  • 1
    • 84860116942 scopus 로고    scopus 로고
    • Insulin-pump therapy for type 1 diabetes mellitus
    • Pickup JC. Insulin-pump therapy for type 1 diabetes mellitus. N Engl J Med 2012; 366:1616-1624.
    • (2012) N Engl J Med , vol.366 , pp. 1616-1624
    • Pickup, J.C.1
  • 2
    • 84860347776 scopus 로고    scopus 로고
    • Use of continuous glucose monitoring in children and adolescents
    • Phillip M, Danne T, Shalitin S, et al. Use of continuous glucose monitoring in children and adolescents. Pediatr Diabetes 2012; 13:215-2283.
    • (2012) Pediatr Diabetes , vol.13 , pp. 215-2283
    • Phillip, M.1    Danne, T.2    Shalitin, S.3
  • 3
    • 0036235002 scopus 로고    scopus 로고
    • Findings from the hvidre study group on childhood diabetes: Metabolic control and quality of life
    • Diabetes HSGoC ed. HB M
    • HB M. Findings from the Hvidre Study Group on Childhood Diabetes: metabolic control and quality of life. In: Diabetes HSGoC, ed. Vol 57: Horm Res; 2002; 117-120.
    • (2002) Horm Res , vol.57 , pp. 117-120
  • 4
    • 84870762398 scopus 로고    scopus 로고
    • The t1d exchange clinic registry
    • Tamborlane WV BR, Miller KM, DuBose SN, Hall CA, Network TDEC, eds.
    • RW B. The T1D Exchange clinic registry. In: Tamborlane WV BR, Miller KM, DuBose SN, Hall CA, Network TDEC, eds. Vol 97. J Clin Endocrinol Metab 2012; 4383-4389.
    • (2012) J Clin Endocrinol Metab , vol.97 , pp. 4383-4389
  • 5
    • 79956192128 scopus 로고    scopus 로고
    • Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes
    • Battelino T, Phillip M, Bratina N, et al. Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes. Diabetes Care 2011; 34:795-800.
    • (2011) Diabetes Care , vol.34 , pp. 795-800
    • Battelino, T.1    Phillip, M.2    Bratina, N.3
  • 6
    • 77954830051 scopus 로고    scopus 로고
    • Effectiveness of sensoraugmented insulin-pump therapy in type 1 diabetes
    • Bergenstal RM, Tamborlane WV, Ahmann A, et al. Effectiveness of sensoraugmented insulin-pump therapy in type 1 diabetes. N Engl J Med 2010; 363:311-320.
    • (2010) N Engl J Med , vol.363 , pp. 311-320
    • Bergenstal, R.M.1    Tamborlane, W.V.2    Ahmann, A.3
  • 7
    • 54849147700 scopus 로고    scopus 로고
    • Continuous glucose monitoring and intensive treatment of type 1 diabetes
    • Tamborlane W, Beck R, BoDe B, et al. Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med 2008; 359:1464-1476.
    • (2008) N Engl J Med , vol.359 , pp. 1464-1476
    • Tamborlane, W.1    Beck, R.2    Bode, B.3
  • 8
    • 33845521334 scopus 로고    scopus 로고
    • Feasibility of automating insulin delivery for the treatment of type 1 diabetes
    • DOI 10.2337/db06-0419
    • SteilGM, Rebrin K, Darwin C, et al. Feasibility of automating insulin Delivery for the treatment of type 1 diabetes. Diabetes 2006; 55:3344-3350. (Pubitemid 44923591)
    • (2006) Diabetes , vol.55 , Issue.12 , pp. 3344-3350
    • Steil, G.M.1    Rebrin, K.2    Darwin, C.3    Hariri, F.4    Saad, M.F.5
  • 9
    • 48649083317 scopus 로고    scopus 로고
    • Fully automated clo sed-loop insulin Delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas
    • Weinzimer S, Steil G, Swan K, et al. Fully automated clo sed-loop insulin Delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Diabetes Care 2008; 31:934-939.
    • (2008) Diabetes Care , vol.31 , pp. 934-939
    • Weinzimer, S.1    Steil, G.2    Swan, K.3
  • 10
    • 77249157244 scopus 로고    scopus 로고
    • Manual closed-loop insulin Delivery in children and adolescents with type 1 diabetes: A phase 2 randomised crossover trial
    • Hovorka R, Allen J, Elleri D, et al. Manual closed-loop insulin Delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial. Lancet 2010; 375:743-751.
    • (2010) Lancet , vol.375 , pp. 743-751
    • Hovorka, R.1    Allen, J.2    Elleri, D.3
  • 11
    • 77954901769 scopus 로고    scopus 로고
    • MD-logic artificial pancreas system: A pilot study in adults with type 1 diabetes
    • Atlas E, Nimri R, Miller S, et al. MD-logic artificial pancreas system: a pilot study in adults with type 1 diabetes. Diabetes Care 2010; 33:1072-1076.
    • (2010) Diabetes Care , vol.33 , pp. 1072-1076
    • Atlas, E.1    Nimri, R.2    Miller, S.3
  • 12
    • 80053387073 scopus 로고    scopus 로고
    • Automatic learning algorithm for the MD-logic artificial pancreas system
    • Miller S, Nimri R, Atlas E, et al. Automatic learning algorithm for the MD-logic artificial pancreas system. Diabetes Technol Ther 2011; 13:983-990.
    • (2011) Diabetes Technol Ther , vol.13 , pp. 983-990
    • Miller, S.1    Nimri, R.2    Atlas, E.3
  • 13
    • 84891862664 scopus 로고    scopus 로고
    • Day and night closed-loop control in adults with type 1 diabete s: A comparison of two closed-loop algorithms driving continuous subcutaneous insulin infusion versus patient self-management
    • Luijf YM, DeVries JH, ZwinDerman K, et al. Day and night closed-loop control in adults with type 1 diabete s: a comparison of two closed-loop algorithms driving continuous subcutaneous insulin infusion versus patient self-management. Diabetes Care 2013; 36:3882-3887.
    • (2013) Diabetes Care , vol.36 , pp. 3882-3887
    • Luijf, Y.M.1    De Vries, J.H.2    Zwinderman, K.3
  • 14
    • 77952987107 scopus 로고    scopus 로고
    • A bihormonal closed-loop artificial pancreas for type 1 diabetes
    • El-Khatib F, Russell S, Nathan D, et al. A bihormonal closed-loop artificial pancreas for type 1 diabetes. Sci Transl Med 2010; 2:27-27.
    • (2010) Sci Transl Med , vol.2 , pp. 27-27
    • El-Khatib, F.1    Russell, S.2    Nathan, D.3
  • 15
    • 84865453569 scopus 로고    scopus 로고
    • Fully integrated artificial pancreas in type 1 diabetes: Modular closed-loop glucose control maintains near normoglycemia
    • Breton M, Farret A, Bruttomes so D, et al. Fully integrated artificial pancreas in type 1 diabetes: modular closed-loop glucose control maintains near normoglycemia. Diabetes 2012; 61:2230-2237.
    • (2012) Diabetes , vol.61 , pp. 2230-2237
    • Breton, M.1    Farret, A.2    Bruttomesso, D.3
  • 16
    • 84873819299 scopus 로고    scopus 로고
    • Closed-loop insulin therapy improves glycemic control in children aged years: A randomized controlled trial
    • Dauber A, Corcia L, Safer J, et al. Closed-loop insulin therapy improves glycemic control in children aged years: a randomized controlled trial. Diabetes Care 2013; 36:222-227
    • (2013) Diabetes Care , vol.36 , pp. 222-227
    • Dauber, A.1    Corcia, L.2    Safer, J.3
  • 17
    • 84864719500 scopus 로고    scopus 로고
    • Feasibili ty study of automated overnight closed-loop glucose control under MD-logic artificial pancreas in patients with type 1 diabetes: The DREAM Project
    • Nimri R, Atlas E, Ajzensztejn M, et al. Feasibili ty study of automated overnight closed-loop glucose control unDer MD-logic artificial pancreas in patients with type 1 diabetes: the DREAM Project. Diabetes Technol Ther 2012; 14:728-735.
    • (2012) Diabetes Technol Ther , vol.14 , pp. 728-735
    • Nimri, R.1    Atlas, E.2    Ajzensztejn, M.3
  • 18
    • 84876789278 scopus 로고    scopus 로고
    • The 'Glucositter'overnight automated closed loop system for type 1 diabetes: A randomized crossover trial
    • Nimri R,Danne T.Kordonouri O,et al, The ' Glucositter' overnight automated closed loop system for type 1 diabetes: a randomized crossover trial,Pediatric Diabetes,2013,14,196-202.
    • (2013) Pediatric Diabetes , vol.14 , pp. 196-202
    • Nimri, R.1    Danne, T.2    Kordonouri, O.3
  • 19
    • 84868109034 scopus 로고    scopus 로고
    • Blood glucose control in type 1 diabetes with a bihormonal bionic endocrine pancreas
    • Russell SJ, El-Khatib FH, Nathan DM, et al. Blood glucose control in type 1 diabetes with a bihormonal bionic endocrine pancreas. Diabetes Care 2012; 35:2148-2155.
    • (2012) Diabetes Care , vol.35 , pp. 2148-2155
    • Russell, S.J.1    El-Khatib, F.H.2    Nathan, D.M.3
  • 20
    • 84877639101 scopus 로고    scopus 로고
    • The effects of inpatient hybrid closed-loop therapy initiated within 1 week of type 1 diabetes diagnosis
    • Buckingham BA, Beck RW, Ruedy KJ, et al . The effects of inpatient hybrid closed-loop therapy initiated within 1 week of type 1 diabetes diagnosis. Diabetes Technol Ther 2013; 15:401-408.
    • (2013) Diabetes Technol Ther , vol.15 , pp. 401-408
    • Buckingham, B.A.1    Beck, R.W.2    Ruedy, K.J.3
  • 21
    • 79951699957 scopus 로고    scopus 로고
    • Closed-loop insulin Delivery during pregnancy complicated by type 1 diabetes
    • Murphy HR, Elleri D, Allen JM, et al. Closed-loop insulin Delivery during pregnancy complicated by type 1 diabetes. Diabetes Care 2011; 34: 406-411.
    • (2011) Diabetes Care , vol.34 , pp. 406-411
    • Murphy, H.R.1    Elleri, D.2    Allen, J.M.3
  • 22
    • 84899089565 scopus 로고    scopus 로고
    • Feasibility of closed-loop ins ulin Delivery in type 2 diabetes: A randomised controlled study
    • Kumareswaran K, Thabit H, Leelarathna L, et al. Feasibility of closed-loop ins ulin Delivery in type 2 diabetes: a randomised controlled study. Diabetes Care 2014; 37:1198-1203.
    • (2014) Diabetes Care , vol.37 , pp. 1198-1203
    • Kumareswaran, K.1    Thabit, H.2    Leelarathna, L.3
  • 23
    • 84892653845 scopus 로고    scopus 로고
    • Accuracy of subcutaneous continuous glucose mon itoring in critically ill adults: Improved sensor performance with enhanced calibrations
    • Leelarathna L, English SW, Thabit H, et al. Accuracy of subcutaneous continuous glucose mon itoring in critically ill adults: improved sensor performance with enhanced calibrations. Diabetes Technol Ther 2014; 16:97-101.
    • (2014) Diabetes Technol Ther , vol.16 , pp. 97-101
    • Leelarathna, L.1    English, S.W.2    Thabit, H.3
  • 24
    • 79959670418 scopus 로고    scopus 로고
    • Semi-closed-loop insulin Delivery systems: Early experience with lowglucose insulin suspend pumps
    • Pickup JC. Semi-closed-loop insulin Delivery systems: early experience with lowglucose insulin suspend pumps. Diabetes Technol Ther 2011; 13:695-698.
    • (2011) Diabetes Technol Ther , vol.13 , pp. 695-698
    • Pickup, J.C.1
  • 25
    • 84884610823 scopus 로고    scopus 로고
    • Effect of sensor-augmented insulin pump therapy and automated insulin sus pension vs standard insulin pump therapy on hypoglycemia in patients with type 1 diabetes: A randomized clinical trial
    • Ly TT, Nicholas JA, Retterath A, et al. Effect of sensor-augmented insulin pump therapy and automated insulin sus pension vs standard insulin pump therapy on hypoglycemia in patients with type 1 diabetes: a randomized clinical trial. JAMA 2013; 310:1240-1247.
    • (2013) JAMA , vol.310 , pp. 1240-1247
    • Ly, T.T.1    Nicholas, J.A.2    Retterath, A.3
  • 26
    • 84880274350 scopus 로고    scopus 로고
    • Threshold-based insulin-pump interruption for reduction of hypoglycemia
    • Bergenstal RM, Klonoff DC, Garg SK, et al. Threshold-based insulin-pump interruption for reduction of hypoglycemia. N Engl J Med 2013; 369:224-232.
    • (2013) N Engl J Med , vol.369 , pp. 224-232
    • Bergenstal, R.M.1    Klonoff, D.C.2    Garg, S.K.3
  • 27
    • 58449094833 scopus 로고    scopus 로고
    • Preventing hypoglycemia using predictive alarm algorithms and insulin pump suspension
    • Buckingham B, Cobry E, Clinton P, et al. Preventing hypoglycemia using predictive alarm algorithms and insulin pump suspension. Diabetes Technol Ther 2009; 11:93-97.
    • (2009) Diabetes Technol Ther , vol.11 , pp. 93-97
    • Buckingham, B.1    Cobry, E.2    Clinton, P.3
  • 28
    • 84882266788 scopus 로고    scopus 로고
    • Outpatient safety assessment of an in-home predictive low-glucose suspend system with type 1 diabetes subjects at elevated risk of nocturnal hypoglycemia
    • Buckingham BA, Cameron F, Calhoun P, et al. Outpatient safety assessment of an in-home predictive low-glucose suspend system with type 1 diabetes subjects at elevated risk of nocturnal hypoglycemia. Diabetes Techno l Ther 2013; 15:622-627.
    • (2013) Diabetes Techno L Ther , vol.15 , pp. 622-627
    • Buckingham, B.A.1    Cameron, F.2    Calhoun, P.3
  • 29
    • 84903819555 scopus 로고    scopus 로고
    • The PILGRIM Study: In silico moDeling of a predictive low glucose management system and feasibility in youth with type 1 diabetes during exercise
    • Danne T, Tsioli C, Kordonouri O, et al. The PILGRIM Study: in silico moDeling of a predictive low glucose management system and feasibility in youth with type 1 diabetes during exercise. Diabetes Technol Ther 2014; 15:27-33.
    • (2014) Diabetes Technol Ther , vol.15 , pp. 27-33
    • Danne, T.1    Tsioli, C.2    Kordonouri, O.3
  • 31
    • 0031935612 scopus 로고    scopus 로고
    • Well-being, cerebral function, and physical fatigue after nocturnal hypoglycemia in IDDM
    • DOI 10.2337/diacare.21.3.341
    • King P, Kong MF, Parkin H, et al. Well being, cerebral function, and physical fatigue after nocturnal hypoglycemia in IDDM. Diabetes Care 1998; 21:341-345. (Pubitemid 28101066)
    • (1998) Diabetes Care , vol.21 , Issue.3 , pp. 341-345
    • King, P.1    Kong, M.-F.2    Parkin, H.3    Macdonald, I.A.4    Tattersall, R.B.5
  • 32
    • 84899077873 scopus 로고    scopus 로고
    • The effects of lowering nighttime and breakfast glucose levels with sensor-augmented pump therapy on hemoglobin A1c levels in type 1 diabetes
    • Maahs DM, Chase HP, Westfall E, et al. The effects of lowering nighttime and breakfast glucose levels with sensor-augmented pump therapy on hemoglobin A1c levels in type 1 diabetes. Diabetes Technol Ther 2014 ; 16:284-291.
    • (2014) Diabetes Technol Ther , vol.16 , pp. 284-291
    • Maahs, D.M.1    Chase, H.P.2    Westfall, E.3
  • 33
    • 84874368884 scopus 로고    scopus 로고
    • Nocturnal glucose control with an artificial pancreas at a diabetes camp
    • Phillip M, Battelino T, Atlas E, et al. Nocturnal glucose control with an artificial pancreas at a diabetes camp. N Engl J Med 2013; 368:824-833.
    • (2013) N Engl J Med , vol.368 , pp. 824-833
    • Phillip, M.1    Battelino, T.2    Atlas, E.3
  • 34
    • 84896390985 scopus 로고    scopus 로고
    • Night glucose control with MD-Logic artificial pancreas in home setting: A single blind, randomized crossover trial-interim analysis
    • Nimri R, Muller I, Atlas E, et al. Night glucose control with MD-Logic artificial pancreas in home setting: a single blind, randomized crossover trial-interim analysis. Pediatr Diabetes 2014; 15:91-99.
    • (2014) Pediatr Diabetes , vol.15 , pp. 91-99
    • Nimri, R.1    Muller, I.2    Atlas, E.3
  • 37
    • 84899117172 scopus 로고    scopus 로고
    • Overnight closed-loop insulin Delivery in young people with type 1 diabertes: A free-living randomized clinical trail
    • Hovorka R, et al. Overnight closed-loop insulin Delivery in young people with type 1 diabertes: a free-living randomized clinical trail. Diabetes Care 2014; 37:1204-1211.
    • (2014) Diabetes Care , vol.37 , pp. 1204-1211
    • Hovorka, R.1
  • 38
    • 84868087308 scopus 로고    scopus 로고
    • The use of an automated, portable glucose control system for overnight glucose control in adolescents and young adults with type 1 diabetes
    • O'Grady MJ, Retterath AJ, Keenan DB, et al. The use of an automated, portable glucose control system for overnight glucose control in adolescents and young adults with type 1 diabetes. Diabetes Care 2012; 35:2182-2187.
    • (2012) Diabetes Care , vol.35 , pp. 2182-2187
    • O'Grady, M.J.1    Retterath, A.J.2    Keenan, D.B.3
  • 39
    • 77953007422 scopus 로고    scopus 로고
    • Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin Delivery and a moDel predictive control algorithm: The Virginia expe rience
    • Clarke W,AnDerson S,Breton M,et al,Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin Delivery and a moDel predictive control algorithm: the Virginia expe rience, J Diabetes Sci Technol, 2009,3,1031-1103.
    • (2009) J Diabetes Sci Technol , vol.3 , pp. 1031-1103
    • Clarke, W.1    Anderson, S.2    Breton, M.3
  • 40
    • 84992268896 scopus 로고    scopus 로고
    • Feasibility of outpatient fully integrated closed-loop control: First studies of wearable artificia l pancreas
    • Kovatchev BP, Renard E, Cobelli C, et al. Feasibility of outpatient fully integrated closed-loop control: first studies of wearable artificia l pancreas. Diabetes Care 2013; 36:1851-1858.
    • (2013) Diabetes Care , vol.36 , pp. 1851-1858
    • Kovatchev, B.P.1    Renard, E.2    Cobelli, C.3
  • 42
    • 84875461530 scopus 로고    scopus 로고
    • Closed-loop basal insulin Delivery over 36 h in adolescents with type 1 diabetes: Randomized clinical trial
    • Elleri D, Allen JM, Kumareswaran K, et al. Closed-loop basal insulin Delivery over 36 h in adolescents with type 1 diabetes: randomized clinical trial. Diabetes Care 2013; 36:838-844.
    • (2013) Diabetes Care , vol.36 , pp. 838-844
    • Elleri, D.1    Allen, J.M.2    Kumareswaran, K.3
  • 43
    • 84896888057 scopus 로고    scopus 로고
    • Feasibility of a portable bihormonal closed-loop system to control glucose excursions at home under free-living conditions for 48 h
    • Van Bon AC, Luijf YM, Koebrugge R, et al. Feasibility of a portable bihormonal closed-loop system to control glucose excursions at home unDer free-living conditions for 48 h. Diabetes Technol Ther 2014; 16:131-136.
    • (2014) Diabetes Technol Ther , vol.16 , pp. 131-136
    • Van Bon, A.C.1    Luijf, Y.M.2    Koebrugge, R.3
  • 45
    • 84891821449 scopus 로고    scopus 로고
    • Time lag of glucose from intravascular to interstitial compartment in humans
    • Basu A, Dube S, Slama M, et al. Time lag of glucose from intravascular to interstitial compartment in humans. Diabetes 2013; 62:4083-4087.
    • (2013) Diabetes , vol.62 , pp. 4083-4087
    • Basu, A.1    Dube, S.2    Slama, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.