-
1
-
-
84868573143
-
Drug transport across the blood-brain barrier
-
Pardridge WM. Drug transport across the blood-brain barrier. J Cereb blood flow Metab 2012; 32: 1959-1972
-
(2012)
J Cereb blood flow Metab
, vol.32
, pp. 1959-1972
-
-
Pardridge, W.M.1
-
2
-
-
84865766754
-
Improved antitumor effect of liposomal doxorubicin after targeted blood-brain barrier disruption by MRI-guided focused ultrasound in rat glioma
-
Treat LH, McDannold N, Zhang Y, Vykhodtseva N, Hynynen K. Improved antitumor effect of liposomal doxorubicin after targeted blood-brain barrier disruption by MRI-guided focused ultrasound in rat glioma. Ultrasound Med Biol 2012; 38: 1716-1725
-
(2012)
Ultrasound Med Biol
, vol.38
, pp. 1716-1725
-
-
Treat, L.H.1
McDannold, N.2
Zhang, Y.3
Vykhodtseva, N.4
Hynynen, K.5
-
3
-
-
84863337655
-
Activation of signaling pathways following localized delivery of systemically administered neurotrophic factors across the blood-brain barrier using focused ultrasound and microbubbles
-
Baseri B, Choi JJ, Deffieux T, Samiotaki G, Tung Y-S, Olumolade O et al. Activation of signaling pathways following localized delivery of systemically administered neurotrophic factors across the blood-brain barrier using focused ultrasound and microbubbles. Phys Med Biol 2012; 57: N65-N81
-
(2012)
Phys Med Biol
, vol.57
-
-
Baseri, B.1
Choi, J.J.2
Deffieux, T.3
Samiotaki, G.4
Tung, Y.-S.5
Olumolade, O.6
-
4
-
-
84879380571
-
Amyloid- plaque reduction, endogenous antibody delivery and glial activation by brain-Targeted, transcranial focused ultrasound
-
Jordaö JF, Thévenot E, Markham-Coultes K, Scarcelli T, Weng Y-Q, Xhima K et al. Amyloid- plaque reduction, endogenous antibody delivery and glial activation by brain-Targeted, transcranial focused ultrasound. Exp Neurol 2013; 248: 16-29
-
(2013)
Exp Neurol
, vol.248
, pp. 16-29
-
-
Jordaö, J.F.1
Thévenot, E.2
Markham-Coultes, K.3
Scarcelli, T.4
Weng, Y.-Q.5
Xhima, K.6
-
5
-
-
84856212147
-
Targeted gene delivery to the mouse brain by MRI-guided focused ultrasound-induced blood-brain barrier disruption
-
Huang Q, Deng J, Wang F, Chen S, Liu Y, Wang Z et al. Targeted gene delivery to the mouse brain by MRI-guided focused ultrasound-induced blood-brain barrier disruption. Exp Neurol 2012; 233: 350-356
-
(2012)
Exp Neurol
, vol.233
, pp. 350-356
-
-
Huang, Q.1
Deng, J.2
Wang, F.3
Chen, S.4
Liu, Y.5
Wang, Z.6
-
6
-
-
84861144207
-
Ultrasoundinduced blood-brain barrier opening
-
Konofagou EE, Tung Y-S, Choi J, Deffieuxa T, Baseria B, Vlachosa F. Ultrasoundinduced blood-brain barrier opening. Curr Pharm Biotechnol 2012; 13: 1332-1345
-
(2012)
Curr Pharm Biotechnol
, vol.13
, pp. 1332-1345
-
-
Konofagou, E.E.1
Tung, Y.-S.2
Choi, J.3
Deffieuxa, T.4
Baseria, B.5
Vlachosa, F.6
-
7
-
-
85045994263
-
Noninvasive and targeted drug delivery to the brain using focused ultrasound
-
Burgess A, Hynynen K. Noninvasive and targeted drug delivery to the brain using focused ultrasound. ACS Chem Neurosci 2013; 8588: 1-7
-
(2013)
ACS Chem Neurosci
, vol.8588
, pp. 1-7
-
-
Burgess, A.1
Hynynen, K.2
-
8
-
-
4143081639
-
Cellular mechanisms of the blood-brain barrier opening induced by ultrasound in presence of microbubbles
-
Sheikov N, McDannold N, Vykhodtseva N, Jolesz F, Hynynen K. Cellular mechanisms of the blood-brain barrier opening induced by ultrasound in presence of microbubbles. Ultrasound Med Biol 2004; 30: 979-989
-
(2004)
Ultrasound Med Biol
, vol.30
, pp. 979-989
-
-
Sheikov, N.1
McDannold, N.2
Vykhodtseva, N.3
Jolesz, F.4
Hynynen, K.5
-
9
-
-
0022067278
-
Permeability of blood-brain barrier to various sized molecules
-
Heistad D. Permeability of blood-brain barrier to various sized molecules. Am J Physiol Circ Physiol 1985; 248: H712-H718
-
(1985)
Am J Physiol Circ Physiol
, vol.248
-
-
Heistad, D.1
-
10
-
-
0023548702
-
Size selectivity of blood-brain barrier permeability at various times after osmotic opening Size selectivity of blood-brain barrier permeability various times after osmotic opening
-
Robinson PJ, Rapoport SI. Size selectivity of blood-brain barrier permeability at various times after osmotic opening Size selectivity of blood-brain barrier permeability various times after osmotic opening. Am J Physiol Regul Integr Comp Physiol 1987; 253: R459-R466
-
(1987)
Am J Physiol Regul Integr Comp Physiol
, vol.253
-
-
Robinson, P.J.1
Rapoport, S.I.2
-
11
-
-
71849102712
-
Molecules of various pharmacologically-relevant sizes can cross the ultrasound-induced blood-brain barrier opening in vivo
-
Choi JJ, Wang S-G, Tung Y-S, Morrison B, Konofagou EE. Molecules of various pharmacologically-relevant sizes can cross the ultrasound-induced blood-brain barrier opening in vivo. Ultrasound Med Biol 2010; 36: 58-67
-
(2010)
Ultrasound Med Biol
, vol.36
, pp. 58-67
-
-
Choi, J.J.1
Wang, S.-G.2
Tung, Y.-S.3
Morrison, B.4
Konofagou, E.E.5
-
12
-
-
84867037082
-
Dynamic study of blood-brain barrier closure after its disruption using ultrasound: A quantitative analysis
-
Marty B, Larrat B, Van Landeghem M, Robic C, Robert P, Port M et al. Dynamic study of blood-brain barrier closure after its disruption using ultrasound: A quantitative analysis. J Cereb Blood Flow Metab 2012; 32: 1948-1958
-
(2012)
J Cereb Blood Flow Metab
, vol.32
, pp. 1948-1958
-
-
Marty, B.1
Larrat, B.2
Van Landeghem, M.3
Robic, C.4
Robert, P.5
Port, M.6
-
13
-
-
79954507590
-
Targeted drug delivery across the blood-brain barrier using ultrasound technique
-
Deng CX. Targeted drug delivery across the blood-brain barrier using ultrasound technique. Ther Deliv 2010; 1: 819-848
-
(2010)
Ther Deliv
, vol.1
, pp. 819-848
-
-
Deng, C.X.1
-
14
-
-
33646123322
-
Vibrating microbubbles poking individual cells: Drug transfer into cells via sonoporation
-
Van Wamel A, Kooiman K, Harteveld M, Emmer M, ten Cate FJ, Versluis M et al. Vibrating microbubbles poking individual cells: Drug transfer into cells via sonoporation. J Control Release 2006; 112: 149-155
-
(2006)
J Control Release
, vol.112
, pp. 149-155
-
-
Van Wamel, A.1
Kooiman, K.2
Harteveld, M.3
Emmer, M.4
Ten Cate, F.J.5
Versluis, M.6
-
15
-
-
81355133102
-
The mechanism of interaction between focused ultrasound and microbubbles in blood-brain barrier opening in mice
-
Tung Y-S, Vlachos F, Feshitan JA, Borden MA, Konofagou EE. The mechanism of interaction between focused ultrasound and microbubbles in blood-brain barrier opening in mice. J Acoust Soc Am 2011; 130: 3059-3067
-
(2011)
J Acoust Soc Am
, vol.130
, pp. 3059-3067
-
-
Tung, Y.-S.1
Vlachos, F.2
Feshitan, J.A.3
Borden, M.A.4
Konofagou, E.E.5
-
16
-
-
78751503427
-
Blood vessel deformations on microsecond time scales by ultrasonic cavitation
-
Chen H, Kreider W, Brayman AA, Bailey MR, Matula TJ. Blood vessel deformations on microsecond time scales by ultrasonic cavitation. Phys Rev Lett 2011; 106: 034301
-
(2011)
Phys Rev Lett
, vol.106
, pp. 034301
-
-
Chen, H.1
Kreider, W.2
Brayman, A.A.3
Bailey, M.R.4
Matula, T.J.5
-
17
-
-
33645513645
-
Targeted disruption of the blood-brain barrier with focused ultrasound: Association with inertial cavitation
-
McDannold N, Vykhodtseva N, Hynynen K. Targeted disruption of the blood-brain barrier with focused ultrasound: Association with inertial cavitation. Phys Med Biol 2006; 2: 793-807
-
(2006)
Phys Med Biol
, vol.2
, pp. 793-807
-
-
McDannold, N.1
Vykhodtseva, N.2
Hynynen, K.3
-
18
-
-
78149317618
-
In vivo transcranial cavitation detection during ultrasound-induced blood-brain barrier opening
-
Tung Y-S, Vlachos F, Choi JJ, Deffieux T, Selert K, Konofagou EE. In vivo transcranial cavitation detection during ultrasound-induced blood-brain barrier opening. Phys Med Biol 2010; 55: 6141-6155
-
(2010)
Phys Med Biol
, vol.55
, pp. 6141-6155
-
-
Tung, Y.-S.1
Vlachos, F.2
Choi, J.J.3
Deffieux, T.4
Selert, K.5
Konofagou, E.E.6
-
19
-
-
77956023302
-
Multi-modality safety assessment of blood-brain barrier opening using focused ultrasound and definity microbubbles: A short-Term study
-
Baseri B, Choi JJ, Tung Y-S, Konofagou EE. Multi-modality safety assessment of blood-brain barrier opening using focused ultrasound and definity microbubbles: A short-Term study. Ultrasound Med Biol 2010; 36: 1445-1459
-
(2010)
Ultrasound Med Biol
, vol.36
, pp. 1445-1459
-
-
Baseri, B.1
Choi, J.J.2
Tung, Y.-S.3
Konofagou, E.E.4
-
20
-
-
84863952172
-
Temporary disruption of the blood-brain barrier by use of ultrasound and microbubbles: Safety and efficacy evaluation in rhesus macaques
-
McDannold N, Arvanitis CD, Vykhodtseva N, Livingstone MS. Temporary disruption of the blood-brain barrier by use of ultrasound and microbubbles: Safety and efficacy evaluation in rhesus macaques. Cancer Res 2012; 72: 3652-3663
-
(2012)
Cancer Res
, vol.72
, pp. 3652-3663
-
-
McDannold, N.1
Arvanitis, C.D.2
Vykhodtseva, N.3
Livingstone, M.S.4
-
21
-
-
27744441243
-
MRI-guided targeted blood-brain barrier disruption with focused ultrasound: Histological findings in rabbits
-
McDannold N, Vykhodtseva N, Raymond S, Jolesz FA, Hynynen K. MRI-guided targeted blood-brain barrier disruption with focused ultrasound: Histological findings in rabbits. Ultrasound Med Biol 2005; 31: 1527-1537
-
(2005)
Ultrasound Med Biol
, vol.31
, pp. 1527-1537
-
-
McDannold, N.1
Vykhodtseva, N.2
Raymond, S.3
Jolesz, F.A.4
Hynynen, K.5
-
22
-
-
84861319114
-
Feedback-controlled focused ultrasound disruption by using an acoustic emissions-based controller
-
O'Reilly MA, Hynynen K. Feedback-controlled focused ultrasound disruption by using an acoustic emissions-based controller. Radiology 2012; 263: 96-106
-
(2012)
Radiology
, vol.263
, pp. 96-106
-
-
O'Reilly, M.A.1
Hynynen, K.2
-
23
-
-
84887136058
-
Targeted drug delivery with focused ultrasound-induced blood-brain barrier opening using acoustically-Activated nanodroplets
-
Chen CC, Sheeran PS, Wu S-Y, Olumolade OO, Dayton Pa, Konofagou EE. Targeted drug delivery with focused ultrasound-induced blood-brain barrier opening using acoustically-Activated nanodroplets. J Control Release 2013; 172: 795-804
-
(2013)
J Control Release
, vol.172
, pp. 795-804
-
-
Chen, C.C.1
Sheeran, P.S.2
Wu, S.-Y.3
Olumolade, O.O.4
Dayton, P.A.5
Konofagou, E.E.6
-
24
-
-
33845675648
-
Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice
-
Choi JJ, Pernot M, Small SA, Konofagou EE. Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice. Ultrasound Med Biol 2007; 33: 95-104
-
(2007)
Ultrasound Med Biol
, vol.33
, pp. 95-104
-
-
Choi, J.J.1
Pernot, M.2
Small, S.A.3
Konofagou, E.E.4
-
25
-
-
0028389111
-
Diffusion of dextran through microporous membrane filters
-
Lebrun L, Junter G-A. Diffusion of dextran through microporous membrane filters. J Memb Sci 1994; 88: 253-261
-
(1994)
J Memb Sci
, vol.88
, pp. 253-261
-
-
Lebrun, L.1
Junter, G.-A.2
-
26
-
-
79955369724
-
Feasibility of noninvasive cavitation-guided blood-brain barrier opening using focused ultrasound and microbubbles in nonhuman primates
-
Tung Y-S, Marquet F, Teichert T, Ferrera V, Konofagou EE. Feasibility of noninvasive cavitation-guided blood-brain barrier opening using focused ultrasound and microbubbles in nonhuman primates. Appl Phys Lett 2011; 98: 163704
-
(2011)
Appl Phys Lett
, vol.98
, pp. 163704
-
-
Tung, Y.-S.1
Marquet, F.2
Teichert, T.3
Ferrera, V.4
Konofagou, E.E.5
-
27
-
-
0030580946
-
Drug delivery through the blood-brain barrier
-
Tamai I, Tsuji A. Drug delivery through the blood-brain barrier. Adv Drug Deliv Rev 1996; 19: 401-424
-
(1996)
Adv Drug Deliv Rev
, vol.19
, pp. 401-424
-
-
Tamai, I.1
Tsuji, A.2
-
28
-
-
76649113997
-
Microbubblesize dependence of focused ultrasound-induced blood-brain barrier opening in mice in vivo
-
Choi JJ, Feshitan JA, Baseri B, Wang S, Tung Y-S, Borden MA et al. Microbubblesize dependence of focused ultrasound-induced blood-brain barrier opening in mice in vivo. IEEE Trans Biomed Eng 2010; 57: 145-154
-
(2010)
IEEE Trans Biomed Eng
, vol.57
, pp. 145-154
-
-
Choi, J.J.1
Feshitan, J.A.2
Baseri, B.3
Wang, S.4
Tung, Y.-S.5
Borden, M.A.6
-
29
-
-
45949097554
-
Effect of focused ultrasound applied with an ultrasound contrast agent on the tight junctional integrity of the brain microvascular endothelium
-
Sheikov N, McDannold N, Sharma S, Hynynen K. Effect of focused ultrasound applied with an ultrasound contrast agent on the tight junctional integrity of the brain microvascular endothelium. Ultrasound Med Biol 2008; 34: 1093-1104
-
(2008)
Ultrasound Med Biol
, vol.34
, pp. 1093-1104
-
-
Sheikov, N.1
McDannold, N.2
Sharma, S.3
Hynynen, K.4
-
30
-
-
78149461802
-
Focused ultrasound-mediated BBB disruption is associated with an increase in activation of AKT: Experimental study in rats
-
Jalali S, Huang Y, Dumont DJ, Hynynen K. Focused ultrasound-mediated BBB disruption is associated with an increase in activation of AKT: Experimental study in rats. BMC Neurol 2010; 10: 114
-
(2010)
BMC Neurol
, vol.10
, pp. 114
-
-
Jalali, S.1
Huang, Y.2
Dumont, D.J.3
Hynynen, K.4
-
31
-
-
77954243074
-
Reorganization of gap junctions after focused ultrasound blood-brain barrier opening in the rat brain
-
Alonso A, Reinz E, Jenne JW, Fatar M, Schmidt-Glenewinkel H, Hennerici MG et al. Reorganization of gap junctions after focused ultrasound blood-brain barrier opening in the rat brain. J Cereb Blood Flow Metab 2010; 30: 1394-1402
-
(2010)
J Cereb Blood Flow Metab
, vol.30
, pp. 1394-1402
-
-
Alonso, A.1
Reinz, E.2
Jenne, J.W.3
Fatar, M.4
Schmidt-Glenewinkel, H.5
Hennerici, M.G.6
-
32
-
-
33746851261
-
Noninvasive localized delivery of Herceptin to the mouse brain by MRI-guided focused ultrasound-induced bloodYbrain barrier disruption
-
Kinoshita M, McDannold N, Jolesz FA, Hynynen K. Noninvasive localized delivery of Herceptin to the mouse brain by MRI-guided focused ultrasound-induced bloodYbrain barrier disruption. Proc Natl Acad Sci USA 2006; 103: 11719-11723
-
(2006)
Proc Natl Acad Sci USA
, vol.103
, pp. 11719-11723
-
-
Kinoshita, M.1
McDannold, N.2
Jolesz, F.A.3
Hynynen, K.4
-
33
-
-
77956287949
-
Antibodies targeted to the brain with image-guided focused ultrasound reduces amyloid-beta plaque load in the TgCRND8 mouse model of Alzheimer's disease
-
Jordaö JF, Ayala-Grosso CA, Markham K, Huang Y, Chopra R, McLaurin J et al. Antibodies targeted to the brain with image-guided focused ultrasound reduces amyloid-beta plaque load in the TgCRND8 mouse model of Alzheimer's disease. PLoS ONE 2010; 5: E10549
-
(2010)
PLoS ONE
, vol.5
-
-
Jordaö, J.F.1
Ayala-Grosso, C.A.2
Markham, K.3
Huang, Y.4
Chopra, R.5
McLaurin, J.6
-
34
-
-
48249140247
-
Ultrasound enhanced delivery of molecular imaging and therapeutic agents in Alzheimer's disease mouse models
-
Raymond SB, Treat LH, Dewey JD, McDannold NJ, Hynynen K, Bacskai BJ. Ultrasound enhanced delivery of molecular imaging and therapeutic agents in Alzheimer's disease mouse models. PLoS ONE 2008; 3: E2175
-
(2008)
PLoS ONE
, vol.3
-
-
Raymond, S.B.1
Treat, L.H.2
Dewey, J.D.3
McDannold, N.J.4
Hynynen, K.5
Bacskai, B.J.6
-
35
-
-
84878848911
-
Focal delivery of AAV2/1-Transgenes into the rat brain by localized ultrasound-induced BBB opening
-
Alonso A, Reinz E, Leuchs B, Kleinschmidt J, Fatar M, Geers B et al. Focal delivery of AAV2/1-Transgenes into the rat brain by localized ultrasound-induced BBB opening. Mol Ther Nucleic Acids 2013; 2: E73
-
(2013)
Mol Ther Nucleic Acids
, vol.2
-
-
Alonso, A.1
Reinz, E.2
Leuchs, B.3
Kleinschmidt, J.4
Fatar, M.5
Geers, B.6
-
36
-
-
84874529633
-
Noninvasive and targeted gene delivery into the brain using microbubble-facilitated focused ultrasound
-
Hsu P-H, Wei K-C, Huang C-Y, Wen C-J, Yen T-C, Liu C-L et al. Noninvasive and targeted gene delivery into the brain using microbubble-facilitated focused ultrasound. PLoS ONE 2013; 8: E57682
-
(2013)
PLoS ONE
, vol.8
-
-
Hsu, P.-H.1
Wei, K.-C.2
Huang, C.-Y.3
Wen, C.-J.4
Yen, T.-C.5
Liu, C.-L.6
-
37
-
-
70449529637
-
Approaches to transport therapeutic drugs across the blood-brain barrier to treat brain diseases
-
Gabathuler R. Approaches to transport therapeutic drugs across the blood-brain barrier to treat brain diseases. Neurobiol Dis 2010; 37: 48-57
-
(2010)
Neurobiol Dis
, vol.37
, pp. 48-57
-
-
Gabathuler, R.1
|