1
-
-
0032752513
-
Determinant of microvolt-level T-wave alternans in patients with dilated cardiomyopathy
-
K. Adachi, Y. Ohnishi and T. Shima, Determinant of microvolt-level T-wave alternans in patients with dilated cardiomyopathy, J. Amer. Coll. Cardiol. 34 (1999) 374-380.
-
(1999)
J. Amer. Coll. Cardiol.
, vol.34
, pp. 374-380
-
-
Adachi, K.1
Ohnishi, Y.2
Shima, T.3
-
2
-
-
21344474383
-
Microvolt T-wave alternans for the risk stratification of ventricular tachyarrhythmic events: A meta-analysis
-
K. G. Anil, H. S. Russell and D. M. Louise, Microvolt T-wave alternans for the risk stratification of ventricular tachyarrhythmic events: A meta-analysis, J. Amer. Coll. Cardiol. 46 (2005) 75-82.
-
(2005)
J. Amer. Coll. Cardiol.
, vol.46
, pp. 75-82
-
-
Anil, K.G.1
Russell, H.S.2
Louise, D.M.3
-
3
-
-
68349119191
-
Using the wavelet transform for T-wave alternans detection
-
M. Boix, B. Cantó and D. Cuesta, Using the wavelet transform for T-wave alternans detection, Math. Comput. Model. 50 (2009) 738-742.
-
(2009)
Math. Comput. Model.
, vol.50
, pp. 738-742
-
-
Boix, M.1
Cantó, B.2
Cuesta, D.3
-
4
-
-
49149122437
-
Adaptive match filter-based method for time vs. Amplitude characterization of microvolt ECG T-wave alternans
-
L. Burattini, W. Zareba and R. Burattini, Adaptive match filter-based method for time vs. amplitude characterization of microvolt ECG T-wave alternans, Ann. Biomed. Engrg. 36 (2008) 1558-1564.
-
(2008)
Ann. Biomed. Engrg.
, vol.36
, pp. 1558-1564
-
-
Burattini, L.1
Zareba, W.2
Burattini, R.3
-
5
-
-
0033430410
-
Correlation method for detection of transient T-wave alternans in digital Holter ECG recordings
-
L. Burattini,W. Zareba and A. J. Moss, Correlation method for detection of transient T-wave alternans in digital Holter ECG recordings, Ann. Noninvasive Electrocardiol. 4 (1999) 416-424.
-
(1999)
Ann. Noninvasive Electrocardiol.
, vol.4
, pp. 416-424
-
-
Burattini, L.1
Zareba, W.2
Moss, A.J.3
-
6
-
-
4043133528
-
Enhancing specificity without sacrificing sensitivity: Potential benefits of using microvolt T-wave alternans testing to risk stratify the MADIT-II population
-
R. J. Cohen, Enhancing specificity without sacrificing sensitivity: Potential benefits of using microvolt T-wave alternans testing to risk stratify the MADIT-II population, Cardioelectrophysiol. Rev. 7 (2003) 438-442.
-
(2003)
Cardioelectrophysiol. Rev.
, vol.7
, pp. 438-442
-
-
Cohen, R.J.1
-
7
-
-
62149106341
-
Enhanced modified moving average analysis of T-wave alternans using a curve matching method: A simulation study
-
D. Cuesta-Frau, P. Micó-Tormos, M. Aboy, M. O. Biagetti, D. Austin and R. A. Quinteiro, Enhanced modified moving average analysis of T-wave alternans using a curve matching method: A simulation study, Med. Biol. Engrg. Comput. 47 (2009) 323-331.
-
(2009)
Med. Biol. Engrg. Comput.
, vol.47
, pp. 323-331
-
-
Cuesta-Frau, D.1
Micó-Tormos, P.2
Aboy, M.3
Biagetti, M.O.4
Austin, D.5
Quinteiro, R.A.6
-
8
-
-
79959494638
-
T-wave alternans evaluation using adaptive time-frequency signal analysis and non-negative matrix factorization
-
B. Ghoraani, S. Krishnan, R. J. Selvaraj and V. S. Chauhan, T-wave alternans evaluation using adaptive time-frequency signal analysis and non-negative matrix factorization, Med. Engrg. Phys. 33 (2011) 700-711.
-
(2011)
Med. Engrg. Phys.
, vol.33
, pp. 700-711
-
-
Ghoraani, B.1
Krishnan, S.2
Selvaraj, R.J.3
Chauhan, V.S.4
-
9
-
-
84903635375
-
T-wave alternans as a predictor for sudden cardiac death after myocardial infarction
-
T. Ikeda, H. Saito and K. Tanno, T-wave alternans as a predictor for sudden cardiac death after myocardial infarction, Amer. J. Cardiol. 35 (2002) 722-730.
-
(2002)
Amer. J. Cardiol.
, vol.35
, pp. 722-730
-
-
Ikeda, T.1
Saito, H.2
Tanno, K.3
-
11
-
-
33646468917
-
Microvolt T-wave alternans: A review of techniques interpretation, utility, clinical studies, and future perspectives
-
H. Majid, A. Arash and S. A. Mohammad, Microvolt T-wave alternans: A review of techniques, interpretation, utility, clinical studies, and future perspectives, Int. J. Cardiol. 109 (2006) 293-306.
-
(2006)
Int. J. Cardiol.
, vol.109
, pp. 293-306
-
-
Majid, H.1
Arash, A.2
Mohammad, S.A.3
-
12
-
-
16444373051
-
Methodological principles of T-wave alternans analysis: A unified framework
-
J. P. Martínez and S. Olmos, Methodological principles of T-wave alternans analysis: A unified framework, IEEE Trans. Biomed. Engrg. 52 (2005) 599-613.
-
(2005)
IEEE Trans. Biomed. Engrg.
, vol.52
, pp. 599-613
-
-
Martínez, J.P.1
Olmos, S.2
-
13
-
-
0017695924
-
Electrocardiogram baseline noise estimation and removal using cubic splines and state space computation techniques
-
C. Meyer and H. Keiser, Electrocardiogram baseline noise estimation and removal using cubic splines and state space computation techniques, Comput. Biomed. Res. 10 (1977) 459-470.
-
(1977)
Comput. Biomed. Res.
, vol.10
, pp. 459-470
-
-
Meyer, C.1
Keiser, H.2
-
15
-
-
30344485732
-
T-wave alternans and the susceptibility to ventricular arrhythmias
-
S. M. Narayan, T-wave alternans and the susceptibility to ventricular arrhythmias, J. Amer. Coll. Cardiol. 47 (2006) 269-281.
-
(2006)
J. Amer. Coll. Cardiol.
, vol.47
, pp. 269-281
-
-
Narayan, S.M.1
-
16
-
-
0025801015
-
Dynamic tracking of cardiac vulnerability by complex demodulation of the T-wave
-
B. D. Nearing, A. H. Huang and R. L. Verrier, Dynamic tracking of cardiac vulnerability by complex demodulation of the T-wave, Science 252 (1991) 437- 440.
-
(1991)
Science
, vol.252
, pp. 437-440
-
-
Nearing, B.D.1
Huang, A.H.2
Verrier, R.L.3
-
17
-
-
0036090028
-
Modified moving average analysis of T-wave alternans to predict ventricular fibrillation with high accuracy
-
B. D. Nearing and R. L. Verrier, Modified moving average analysis of T-wave alternans to predict ventricular fibrillation with high accuracy, J. Appl. Physiol. 92 (2002) 541-549.
-
(2002)
J. Appl. Physiol.
, vol.92
, pp. 541-549
-
-
Nearing, B.D.1
Verrier, R.L.2
-
18
-
-
79952929470
-
An adaptive kalman filter for ECG signal enhancement
-
V. Rik, D. V. Bert andW. M. Jan, An adaptive kalman filter for ECG signal enhancement, IEEE Trans. Biomed. Engrg. 58 (2011) 1094-1103.
-
(2011)
IEEE Trans. Biomed. Engrg.
, vol.58
, pp. 1094-1103
-
-
Rik, V.1
Bert, D.V.2
Jan, W.M.3
-
19
-
-
0028069574
-
Electrical alternans and vulnerability to ventricular arrhythmic
-
D. S. Rosenbaum, L. E. Jackson, J. M. Smith, H. Garan, J. N. Ruskin and R. J. Cohen, Electrical alternans and vulnerability to ventricular arrhythmic, N. Engl. J. Med. 330 (1994) 235-241.
-
(1994)
N. Engl. J. Med.
, vol.330
, pp. 235-241
-
-
Rosenbaum, D.S.1
Jackson, L.E.2
Smith, J.M.3
Garan, H.4
Ruskin, J.N.5
Cohen, R.J.6
-
20
-
-
0033596974
-
Cellular and ionic basis for T-wave alternans under long QT conditions
-
W. Shimizu and C. Antzelevitch, Cellular and ionic basis for T-wave alternans under long QT conditions, Circulation 99 (1999) 1499-1507.
-
(1999)
Circulation
, vol.99
, pp. 1499-1507
-
-
Shimizu, W.1
Antzelevitch, C.2
-
21
-
-
0023928342
-
Electrical alternans and cardiac electrical instability
-
J. M. Smith, E. A. Clancy, C. R. Valeri, J. N. Ruskin and R. J. Cohen, Electrical alternans and cardiac electrical instability, Circulation 77 (1988) 110-121.
-
(1988)
Circulation
, vol.77
, pp. 110-121
-
-
Smith, J.M.1
Clancy, E.A.2
Valeri, C.R.3
Ruskin, J.N.4
Cohen, R.J.5
-
22
-
-
0035503270
-
Stable IIR notch filter design with optimal pole placement
-
C. C. Tseng and S. C. Pei, Stable IIR notch filter design with optimal pole placement, IEEE Trans. Signal Process. 49 (2001) 2673-2681.
-
(2001)
IEEE Trans. Signal Process.
, vol.49
, pp. 2673-2681
-
-
Tseng, C.C.1
Pei, S.C.2
|