메뉴 건너뛰기




Volumn 7, Issue 4, 2014, Pages

Improved modified moving average analysis of T-wave alternans using least squares-based curve fitting method

Author keywords

curve fitting; Electrocardiograph; least squares method; modified moving average; T wave alternans

Indexed keywords


EID: 84903554868     PISSN: 17935245     EISSN: 17937159     Source Type: Journal    
DOI: 10.1142/S1793524514500442     Document Type: Article
Times cited : (3)

References (22)
  • 1
    • 0032752513 scopus 로고    scopus 로고
    • Determinant of microvolt-level T-wave alternans in patients with dilated cardiomyopathy
    • K. Adachi, Y. Ohnishi and T. Shima, Determinant of microvolt-level T-wave alternans in patients with dilated cardiomyopathy, J. Amer. Coll. Cardiol. 34 (1999) 374-380.
    • (1999) J. Amer. Coll. Cardiol. , vol.34 , pp. 374-380
    • Adachi, K.1    Ohnishi, Y.2    Shima, T.3
  • 2
    • 21344474383 scopus 로고    scopus 로고
    • Microvolt T-wave alternans for the risk stratification of ventricular tachyarrhythmic events: A meta-analysis
    • K. G. Anil, H. S. Russell and D. M. Louise, Microvolt T-wave alternans for the risk stratification of ventricular tachyarrhythmic events: A meta-analysis, J. Amer. Coll. Cardiol. 46 (2005) 75-82.
    • (2005) J. Amer. Coll. Cardiol. , vol.46 , pp. 75-82
    • Anil, K.G.1    Russell, H.S.2    Louise, D.M.3
  • 3
    • 68349119191 scopus 로고    scopus 로고
    • Using the wavelet transform for T-wave alternans detection
    • M. Boix, B. Cantó and D. Cuesta, Using the wavelet transform for T-wave alternans detection, Math. Comput. Model. 50 (2009) 738-742.
    • (2009) Math. Comput. Model. , vol.50 , pp. 738-742
    • Boix, M.1    Cantó, B.2    Cuesta, D.3
  • 4
    • 49149122437 scopus 로고    scopus 로고
    • Adaptive match filter-based method for time vs. Amplitude characterization of microvolt ECG T-wave alternans
    • L. Burattini, W. Zareba and R. Burattini, Adaptive match filter-based method for time vs. amplitude characterization of microvolt ECG T-wave alternans, Ann. Biomed. Engrg. 36 (2008) 1558-1564.
    • (2008) Ann. Biomed. Engrg. , vol.36 , pp. 1558-1564
    • Burattini, L.1    Zareba, W.2    Burattini, R.3
  • 5
    • 0033430410 scopus 로고    scopus 로고
    • Correlation method for detection of transient T-wave alternans in digital Holter ECG recordings
    • L. Burattini,W. Zareba and A. J. Moss, Correlation method for detection of transient T-wave alternans in digital Holter ECG recordings, Ann. Noninvasive Electrocardiol. 4 (1999) 416-424.
    • (1999) Ann. Noninvasive Electrocardiol. , vol.4 , pp. 416-424
    • Burattini, L.1    Zareba, W.2    Moss, A.J.3
  • 6
    • 4043133528 scopus 로고    scopus 로고
    • Enhancing specificity without sacrificing sensitivity: Potential benefits of using microvolt T-wave alternans testing to risk stratify the MADIT-II population
    • R. J. Cohen, Enhancing specificity without sacrificing sensitivity: Potential benefits of using microvolt T-wave alternans testing to risk stratify the MADIT-II population, Cardioelectrophysiol. Rev. 7 (2003) 438-442.
    • (2003) Cardioelectrophysiol. Rev. , vol.7 , pp. 438-442
    • Cohen, R.J.1
  • 8
    • 79959494638 scopus 로고    scopus 로고
    • T-wave alternans evaluation using adaptive time-frequency signal analysis and non-negative matrix factorization
    • B. Ghoraani, S. Krishnan, R. J. Selvaraj and V. S. Chauhan, T-wave alternans evaluation using adaptive time-frequency signal analysis and non-negative matrix factorization, Med. Engrg. Phys. 33 (2011) 700-711.
    • (2011) Med. Engrg. Phys. , vol.33 , pp. 700-711
    • Ghoraani, B.1    Krishnan, S.2    Selvaraj, R.J.3    Chauhan, V.S.4
  • 9
    • 84903635375 scopus 로고    scopus 로고
    • T-wave alternans as a predictor for sudden cardiac death after myocardial infarction
    • T. Ikeda, H. Saito and K. Tanno, T-wave alternans as a predictor for sudden cardiac death after myocardial infarction, Amer. J. Cardiol. 35 (2002) 722-730.
    • (2002) Amer. J. Cardiol. , vol.35 , pp. 722-730
    • Ikeda, T.1    Saito, H.2    Tanno, K.3
  • 11
    • 33646468917 scopus 로고    scopus 로고
    • Microvolt T-wave alternans: A review of techniques interpretation, utility, clinical studies, and future perspectives
    • H. Majid, A. Arash and S. A. Mohammad, Microvolt T-wave alternans: A review of techniques, interpretation, utility, clinical studies, and future perspectives, Int. J. Cardiol. 109 (2006) 293-306.
    • (2006) Int. J. Cardiol. , vol.109 , pp. 293-306
    • Majid, H.1    Arash, A.2    Mohammad, S.A.3
  • 12
    • 16444373051 scopus 로고    scopus 로고
    • Methodological principles of T-wave alternans analysis: A unified framework
    • J. P. Martínez and S. Olmos, Methodological principles of T-wave alternans analysis: A unified framework, IEEE Trans. Biomed. Engrg. 52 (2005) 599-613.
    • (2005) IEEE Trans. Biomed. Engrg. , vol.52 , pp. 599-613
    • Martínez, J.P.1    Olmos, S.2
  • 13
    • 0017695924 scopus 로고
    • Electrocardiogram baseline noise estimation and removal using cubic splines and state space computation techniques
    • C. Meyer and H. Keiser, Electrocardiogram baseline noise estimation and removal using cubic splines and state space computation techniques, Comput. Biomed. Res. 10 (1977) 459-470.
    • (1977) Comput. Biomed. Res. , vol.10 , pp. 459-470
    • Meyer, C.1    Keiser, H.2
  • 15
    • 30344485732 scopus 로고    scopus 로고
    • T-wave alternans and the susceptibility to ventricular arrhythmias
    • S. M. Narayan, T-wave alternans and the susceptibility to ventricular arrhythmias, J. Amer. Coll. Cardiol. 47 (2006) 269-281.
    • (2006) J. Amer. Coll. Cardiol. , vol.47 , pp. 269-281
    • Narayan, S.M.1
  • 16
    • 0025801015 scopus 로고
    • Dynamic tracking of cardiac vulnerability by complex demodulation of the T-wave
    • B. D. Nearing, A. H. Huang and R. L. Verrier, Dynamic tracking of cardiac vulnerability by complex demodulation of the T-wave, Science 252 (1991) 437- 440.
    • (1991) Science , vol.252 , pp. 437-440
    • Nearing, B.D.1    Huang, A.H.2    Verrier, R.L.3
  • 17
    • 0036090028 scopus 로고    scopus 로고
    • Modified moving average analysis of T-wave alternans to predict ventricular fibrillation with high accuracy
    • B. D. Nearing and R. L. Verrier, Modified moving average analysis of T-wave alternans to predict ventricular fibrillation with high accuracy, J. Appl. Physiol. 92 (2002) 541-549.
    • (2002) J. Appl. Physiol. , vol.92 , pp. 541-549
    • Nearing, B.D.1    Verrier, R.L.2
  • 18
    • 79952929470 scopus 로고    scopus 로고
    • An adaptive kalman filter for ECG signal enhancement
    • V. Rik, D. V. Bert andW. M. Jan, An adaptive kalman filter for ECG signal enhancement, IEEE Trans. Biomed. Engrg. 58 (2011) 1094-1103.
    • (2011) IEEE Trans. Biomed. Engrg. , vol.58 , pp. 1094-1103
    • Rik, V.1    Bert, D.V.2    Jan, W.M.3
  • 20
    • 0033596974 scopus 로고    scopus 로고
    • Cellular and ionic basis for T-wave alternans under long QT conditions
    • W. Shimizu and C. Antzelevitch, Cellular and ionic basis for T-wave alternans under long QT conditions, Circulation 99 (1999) 1499-1507.
    • (1999) Circulation , vol.99 , pp. 1499-1507
    • Shimizu, W.1    Antzelevitch, C.2
  • 22
    • 0035503270 scopus 로고    scopus 로고
    • Stable IIR notch filter design with optimal pole placement
    • C. C. Tseng and S. C. Pei, Stable IIR notch filter design with optimal pole placement, IEEE Trans. Signal Process. 49 (2001) 2673-2681.
    • (2001) IEEE Trans. Signal Process. , vol.49 , pp. 2673-2681
    • Tseng, C.C.1    Pei, S.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.