메뉴 건너뛰기




Volumn 41, Issue 7, 2014, Pages

Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method

Author keywords

CT; low dose; myocardial perfusion; statistical iterative reconstruction

Indexed keywords

AMMONIA; FLOW MEASUREMENT; IMAGE ENHANCEMENT; IMAGE RECONSTRUCTION; ITERATIVE METHODS; MAMMALS; NUMERICAL MODELS; PHOTONS; STATISTICS;

EID: 84903204861     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4884023     Document Type: Article
Times cited : (26)

References (49)
  • 1
    • 33750206253 scopus 로고    scopus 로고
    • Assessment of coronary artery disease by cardiac computed tomography: A scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology
    • DOI 10.1161/CIRCULATIONAHA.106.178458, PII 0000301720061017000018
    • M. J. Budoff et al., " Assessment of coronary artery disease by cardiac computed tomography: A scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology," Circulation 114, 1761-1791 (2006). 10.1161/CIRCULATIONAHA.106.178458 (Pubitemid 44607126)
    • (2006) Circulation , vol.114 , Issue.16 , pp. 1761-1791
    • Budoff, M.J.1    Achenbach, S.2    Blumenthal, R.S.3    Carr, J.J.4    Goldin, J.G.5    Greenland, P.6    Guerci, A.D.7    Lima, J.A.C.8    Rader, D.J.9    Rubin, G.D.10    Shaw, L.J.11    Wiegers, S.E.12
  • 2
    • 79959282738 scopus 로고    scopus 로고
    • A systematic review of the clinical effectiveness of 64-slice or higher computed tomography angiography as an alternative to invasive coronary angiography in the investigation of suspected coronary artery disease
    • 10.1186/1471-2261-11-32
    • D. C. Paech and A. R. Weston, " A systematic review of the clinical effectiveness of 64-slice or higher computed tomography angiography as an alternative to invasive coronary angiography in the investigation of suspected coronary artery disease," BMC Cardiovasc. Disorders 11, 32-42 (2011). 10.1186/1471-2261-11-32
    • (2011) BMC Cardiovasc. Disorders , vol.11 , pp. 32-42
    • Paech, D.C.1    Weston, A.R.2
  • 3
    • 0029118617 scopus 로고
    • Quantitative coronary angiography in predicting functional significance of stenoses in an unselected patient cohort
    • 10.1016/0735-1097(95)80003-Y
    • J. Bartúnek, S. U. Sys, G. R. Heyndrickx, N. H. Pijls, and B. De Bruyne, " Quantitative coronary angiography in predicting functional significance of stenoses in an unselected patient cohort," J. Am. Coll. Cardiol. 26, 328-334 (1995). 10.1016/0735-1097(95)80003-Y
    • (1995) J. Am. Coll. Cardiol. , vol.26 , pp. 328-334
    • Bartúnek, J.1    Sys, S.U.2    Heyndrickx, G.R.3    Pijls, N.H.4    De Bruyne, B.5
  • 6
    • 0028876102 scopus 로고
    • Our preoccupation with coronary luminology: The dissociation between clinical and angiographic findings in ischemic heart disease
    • 10.1161/01.CIR.92.8.2333
    • E. J. Topol and S. E. Nissen, " Our preoccupation with coronary luminology: The dissociation between clinical and angiographic findings in ischemic heart disease," Circulation 92, 2333-2342 (1995). 10.1161/01.CIR.92.8.2333
    • (1995) Circulation , vol.92 , pp. 2333-2342
    • Topol, E.J.1    Nissen, S.E.2
  • 7
    • 57449115879 scopus 로고    scopus 로고
    • Diagnostic accuracy of 64-slice computed tomography coronary angiography: A prospective, multicenter, multivendor study
    • 10.1016/j.jacc.2008.08.058
    • W. B. Meijboom et al., " Diagnostic accuracy of 64-slice computed tomography coronary angiography: A prospective, multicenter, multivendor study," J. Am. Coll. Cardiol. 52, 2135-2144 (2008). 10.1016/j.jacc.2008.08. 058
    • (2008) J. Am. Coll. Cardiol. , vol.52 , pp. 2135-2144
    • Meijboom, W.B.1
  • 8
    • 0141430974 scopus 로고    scopus 로고
    • ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging - Executive summary: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging)
    • DOI 10.1161/01.CIR.0000080946.42225.4D
    • F. J. Klocke, M. G. Baird, B. H. Lorell, T. M. Bateman, J. V. Messer, D. S. Berman, P. T. O'Gara, B. A. Carabello, R. O. Russell Jr., M. D. Cerqueira, M. G. St John Sutton, A. N. DeMaria, J. E. Udelson, J. W. Kennedy, M. S. Verani, K. A. Williams, E. M. Antman, S. C. Smith Jr., J. S. Alpert, G. Gregoratos, J. L. Anderson, L. F. Hiratzka, D. P. Faxon, S. A. Hunt, V. Fuster, A. K. Jacobs, R. J. Gibbons, and R. O. Russell, American College of Cardiology, American Heart Association Task Force on Practice Guidelines, and American Society of Nuclear Cardiology, " ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging-executive summary: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to revise the 1995 guidelines for the clinical use of cardiac radionuclide imaging)," Circulation 108, 1404-1418 (2003). 10.1161/01.CIR.0000080946.42225.4D (Pubitemid 37174421)
    • (2003) Circulation , vol.108 , Issue.11 , pp. 1404-1418
    • Klocke, F.J.1    Baird, M.G.2    Lorell, B.H.3    Bateman, T.M.4    Messer, J.V.5    Berman, D.S.6    O'Gara, P.T.7    Carabello, B.A.8    Russell Jr., R.O.9    Cerqueira, M.D.10    St. John Sutton, M.G.11    DeMaria, A.N.12    Udelson, J.E.13    Kennedy, J.W.14    Verani, M.S.15    Williams, K.A.16
  • 9
    • 66149093844 scopus 로고    scopus 로고
    • ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging
    • 10.1016/j.jacc.2009.02.013
    • R. C. Hendel, D. S. Berman, M. F. Di Carli, P. A. Heidenreich, R. E. Henkin, P. A. Pellikka, G. M. Pohost, and K. A. Williams, " ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, The American Society of Nuclear Cardiology, The American College of Radiology, The American Heart Association, The American Society of Echocardiography, The Society of Cardiovascular Computed Tomography, The Society for Cardiovascular Magnetic Resonance, and The Society of Nuclear Medicine endorsed by the American College of Emergency Physicians," J. Am. Coll. Cardiol. 53, 2201-2229 (2009). 10.1016/j.jacc.2009.02.013
    • (2009) J. Am. Coll. Cardiol. , vol.53 , pp. 2201-2229
    • Hendel, R.C.1    Berman, D.S.2    Di Carli, M.F.3    Heidenreich, P.A.4    Henkin, R.E.5    Pellikka, P.A.6    Pohost, G.M.7    Williams, K.A.8
  • 10
    • 77956625311 scopus 로고    scopus 로고
    • Stress and rest dynamic myocardial perfusion imaging by evaluation of complete time-attenuation curves with dual-source CT
    • 10.1016/j.jcmg.2010.05.009
    • K.-T. Ho, K.-C. Chua, E. Klotz, and C. Panknin, " Stress and rest dynamic myocardial perfusion imaging by evaluation of complete time-attenuation curves with dual-source CT," JACC Cardiovasc. Imaging 3, 811-820 (2010). 10.1016/j.jcmg.2010.05.009
    • (2010) JACC Cardiovasc. Imaging , vol.3 , pp. 811-820
    • Ho, K.-T.1    Chua, K.-C.2    Klotz, E.3    Panknin, C.4
  • 12
    • 84863287976 scopus 로고    scopus 로고
    • Adenosine-stress dynamic myocardial perfusion imaging with second-generation dual-source CT: Comparison with conventional catheter coronary angiography and SPECT nuclear myocardial perfusion imaging
    • 10.2214/AJR.11.7830
    • Y. Wang, L. Qin, X. Shi, Y. Zeng, H. Jing, U. J. Schoepf, and Z. Jin, " Adenosine-stress dynamic myocardial perfusion imaging with second-generation dual-source CT: Comparison with conventional catheter coronary angiography and SPECT nuclear myocardial perfusion imaging," AJR, Am. J. Roentgenol. 198, 521-529 (2012). 10.2214/AJR.11.7830
    • (2012) AJR, Am. J. Roentgenol. , vol.198 , pp. 521-529
    • Wang, Y.1    Qin, L.2    Shi, X.3    Zeng, Y.4    Jing, H.5    Schoepf, U.J.6    Jin, Z.7
  • 14
    • 70249150501 scopus 로고    scopus 로고
    • Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: A pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia
    • 10.1161/CIRCIMAGING.108.813766
    • R. T. George, A. Arbab-Zadeh, J. M. Miller, K. Kitagawa, H.-J. Chang, D. A. Bluemke, L. Becker, O. Yousuf, J. Texter, A. C. Lardo, and J. A. C. Lima, " Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: A pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia," Circ. Cardiovasc. Imaging 2, 174-182 (2009). 10.1161/CIRCIMAGING.108.813766
    • (2009) Circ. Cardiovasc. Imaging , vol.2 , pp. 174-182
    • George, R.T.1    Arbab-Zadeh, A.2    Miller, J.M.3    Kitagawa, K.4    Chang, H.-J.5    Bluemke, D.A.6    Becker, L.7    Yousuf, O.8    Texter, J.9    Lardo, A.C.10    Lima, J.A.C.11
  • 18
    • 82955184517 scopus 로고    scopus 로고
    • Additional value of dipyridamole stress myocardial perfusion by 64-row computed tomography in patients with coronary stents
    • 10.1016/j.jcct.2011.10.013
    • T. A. Magalhaes, R. C. Cury, A. C. Pereira, V. d. M. Moreira, P. A. Lemos, R. Kalil-Filho, and C. E. Rochitte, " Additional value of dipyridamole stress myocardial perfusion by 64-row computed tomography in patients with coronary stents," J. Cardiovasc. Comput. Tomogr. 5, 449-458 (2011). 10.1016/j.jcct.2011.10.013
    • (2011) J. Cardiovasc. Comput. Tomogr. , vol.5 , pp. 449-458
    • Magalhaes, T.A.1    Cury, R.C.2    Pereira, A.C.3    Moreira D. V, M.4    Lemos, P.A.5    Kalil-Filho, R.6    Rochitte, C.E.7
  • 19
    • 84863877648 scopus 로고    scopus 로고
    • Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results
    • 10.1016/j.ejrad.2010.11.022
    • M. Weininger, U. J. Schoepf, A. Ramachandra, C. Fink, G. W. Rowe, P. Costello, and T. Henzler, " Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results," Eur. J. Radiol. 81, 3703-3710 (2012). 10.1016/j.ejrad.2010.11.022
    • (2012) Eur. J. Radiol. , vol.81 , pp. 3703-3710
    • Weininger, M.1    Schoepf, U.J.2    Ramachandra, A.3    Fink, C.4    Rowe, G.W.5    Costello, P.6    Henzler, T.7
  • 20
    • 77952519370 scopus 로고    scopus 로고
    • Quantitative whole heart stress perfusion CT imaging as noninvasive assessment of hemodynamics in coronary artery stenosis: Preliminary animal experience
    • 10.1097/RLI.0b013e3181dfa3cf
    • A. H. Mahnken, E. Klotz, H. Pietsch, B. Schmidt, T. Allmendinger, U. Haberland, W. A. Kalender, and T. Flohr, " Quantitative whole heart stress perfusion CT imaging as noninvasive assessment of hemodynamics in coronary artery stenosis: Preliminary animal experience," Invest. Radiol. 45, 298-305 (2010). 10.1097/RLI.0b013e3181dfa3cf
    • (2010) Invest. Radiol. , vol.45 , pp. 298-305
    • Mahnken, A.H.1    Klotz, E.2    Pietsch, H.3    Schmidt, B.4    Allmendinger, T.5    Haberland, U.6    Kalender, W.A.7    Flohr, T.8
  • 21
    • 77952532043 scopus 로고    scopus 로고
    • Adenosine-stress dynamic myocardial CT perfusion imaging: Initial clinical experience
    • 10.1097/RLI.0b013e3181dfa2f2
    • G. Bastarrika, L. Ramos-Duran, M. A. Rosenblum, D. K. Kang, G. W. Rowe, and U. J. Schoepf, " Adenosine-stress dynamic myocardial CT perfusion imaging: Initial clinical experience," Invest. Radiol. 45, 306-313 (2010). 10.1097/RLI.0b013e3181dfa2f2
    • (2010) Invest. Radiol. , vol.45 , pp. 306-313
    • Bastarrika, G.1    Ramos-Duran, L.2    Rosenblum, M.A.3    Kang, D.K.4    Rowe, G.W.5    Schoepf, U.J.6
  • 22
    • 79959591690 scopus 로고    scopus 로고
    • Radiation dose at coronary CT angiography: Second-generation dual-source CT versus single-source 64-MDCT and first-generation dual-source CT
    • 10.2214/AJR.10.5153
    • C. Fink, R. Krissak, T. Henzler, U. Lechel, G. Brix, R. A. Takx, J. W. Nance, J. A. Abro, S. O. Schoenberg, and U. J. Schoepf, " Radiation dose at coronary CT angiography: Second-generation dual-source CT versus single-source 64-MDCT and first-generation dual-source CT," AJR, Am. J. Roentgenol. 196, W550-W557 (2011). 10.2214/AJR.10.5153
    • (2011) AJR, Am. J. Roentgenol. , vol.196
    • Fink, C.1    Krissak, R.2    Henzler, T.3    Lechel, U.4    Brix, G.5    Takx, R.A.6    Nance, J.W.7    Abro, J.A.8    Schoenberg, S.O.9    Schoepf, U.J.10
  • 23
    • 84861595772 scopus 로고    scopus 로고
    • Radiation dose of CT coronary angiography in clinical practice: Objective evaluation of strategies for dose optimization
    • 10.1016/j.ejrad.2011.02.040
    • A. Yerramasu, S. Venuraju, S. Atwal, D. Goodman, D. Lipkin, and A. Lahiri, " Radiation dose of CT coronary angiography in clinical practice: Objective evaluation of strategies for dose optimization," Eur. J. Radiol. 81, 1555-1561 (2012). 10.1016/j.ejrad.2011.02.040
    • (2012) Eur. J. Radiol. , vol.81 , pp. 1555-1561
    • Yerramasu, A.1    Venuraju, S.2    Atwal, S.3    Goodman, D.4    Lipkin, D.5    Lahiri, A.6
  • 24
    • 84875430945 scopus 로고    scopus 로고
    • Submillisievert median radiation dose for coronary angiography with a second-generation 320-detector row CT scanner in 107 consecutive patients
    • 10.1148/radiol.13122621
    • M. Y. Chen, S. M. Shanbhag, and A. E. Arai, " Submillisievert median radiation dose for coronary angiography with a second-generation 320-detector row CT scanner in 107 consecutive patients," Radiology 267, 76-85 (2013). 10.1148/radiol.13122621
    • (2013) Radiology , vol.267 , pp. 76-85
    • Chen, M.Y.1    Shanbhag, S.M.2    Arai, A.E.3
  • 25
    • 0032319446 scopus 로고    scopus 로고
    • Bilateral filtering for gray and color images
    • Bombay, India, 1998 (IEEE Computer Society, Washington DC), 10.1109/ICCV.1998.710815
    • C. Tomasi and R. Manduchi, " Bilateral filtering for gray and color images," in Proceedings of the Sixth International Conference on Computer Vision, Bombay, India, 1998 (IEEE Computer Society, Washington DC, 1998), pp. 839-846. 10.1109/ICCV.1998.710815
    • (1998) Proceedings of the Sixth International Conference on Computer Vision , pp. 839-846
    • Tomasi, C.1    Manduchi, R.2
  • 27
    • 0024700097 scopus 로고
    • A theory for multiresolution signal decomposition: The wavelet representation
    • 10.1109/34.192463
    • S. G. Mallat, " A theory for multiresolution signal decomposition: The wavelet representation," IEEE Trans. Pattern Anal. Mach. Intell. 11, 674-693 (1989). 10.1109/34.192463
    • (1989) IEEE Trans. Pattern Anal. Mach. Intell. , vol.11 , pp. 674-693
    • Mallat, S.G.1
  • 28
    • 0041958932 scopus 로고
    • Ideal spatial adaptation by wavelet shrinkage
    • 10.1093/biomet/81.3.425
    • D. L. Donoho and J. M. Johnstone, " Ideal spatial adaptation by wavelet shrinkage," Biometrika 81, 425-455 (1994). 10.1093/biomet/81.3.425
    • (1994) Biometrika , vol.81 , pp. 425-455
    • Donoho, D.L.1    Johnstone, J.M.2
  • 29
    • 0028546845 scopus 로고
    • Wavelet transform domain filters: A spatially selective noise filtration technique
    • 10.1109/83.336245
    • Y. Xu, J. B. Weaver, D. M. Healy, and J. Lu, " Wavelet transform domain filters: A spatially selective noise filtration technique," IEEE Trans. Image Process. 3, 747-758 (1994). 10.1109/83.336245
    • (1994) IEEE Trans. Image Process. , vol.3 , pp. 747-758
    • Xu, Y.1    Weaver, J.B.2    Healy, D.M.3    Lu, J.4
  • 30
    • 56849091499 scopus 로고    scopus 로고
    • Wavelet based noise reduction in CT-images using correlation analysis
    • 10.1109/TMI.2008.923983
    • A. Borsdorf, R. Raupach, T. Flohr, and J. Hornegger, " Wavelet based noise reduction in CT-images using correlation analysis," IEEE Trans. Med. Imaging 27, 1685-1703 (2008). 10.1109/TMI.2008.923983
    • (2008) IEEE Trans. Med. Imaging , vol.27 , pp. 1685-1703
    • Borsdorf, A.1    Raupach, R.2    Flohr, T.3    Hornegger, J.4
  • 31
    • 79955784272 scopus 로고    scopus 로고
    • Radiation dose reduction in computed tomography (CT) using a new implementation of wavelet denoising in low tube current acquisitions
    • 10.1117/12.878362
    • Y. Tao, S. Brunner, J. Tang, M. Speidel, H. Rowley, M. VanLysel, and G.-H. Chen, " Radiation dose reduction in computed tomography (CT) using a new implementation of wavelet denoising in low tube current acquisitions," Proc. SPIE 7961, 79613M (2011). 10.1117/12.878362
    • (2011) Proc. SPIE , vol.7961
    • Tao, Y.1    Brunner, S.2    Tang, J.3    Speidel, M.4    Rowley, H.5    Vanlysel, M.6    Chen, G.-H.7
  • 34
    • 70349860087 scopus 로고    scopus 로고
    • Noise reduction in computed tomography scans using 3-D anisotropic hybrid diffusion with continuous switch
    • 10.1109/TMI.2009.2022368
    • A. M. Mendrik, E.-J. Vonken, A. Rutten, M. A. Viergever, and B. van Ginneken, " Noise reduction in computed tomography scans using 3-D anisotropic hybrid diffusion with continuous switch," IEEE Trans. Med. Imaging 28, 1585-1594 (2009). 10.1109/TMI.2009.2022368
    • (2009) IEEE Trans. Med. Imaging , vol.28 , pp. 1585-1594
    • Mendrik, A.M.1    Vonken, E.-J.2    Rutten, A.3    Viergever, M.A.4    Van Ginneken, B.5
  • 35
    • 0010293907 scopus 로고
    • A statistical model for positron emission tomography
    • 10.1080/01621459.1985.10477119
    • Y. Vardi, L. Shepp, and L. Kaufman, " A statistical model for positron emission tomography," J. Am. Stat. Assoc. 80, 8-20 (1985). 10.1080/01621459.1985.10477119
    • (1985) J. Am. Stat. Assoc. , vol.80 , pp. 8-20
    • Vardi, Y.1    Shepp, L.2    Kaufman, L.3
  • 36
    • 0028446166 scopus 로고
    • Penalized weighted least-squares image reconstruction for positron emission tomography
    • 10.1109/42.293921
    • J. A. Fessler, " Penalized weighted least-squares image reconstruction for positron emission tomography," IEEE Trans. Med. Imaging 13, 290-300 (1994). 10.1109/42.293921
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 290-300
    • Fessler, J.A.1
  • 37
    • 84864223319 scopus 로고    scopus 로고
    • Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging
    • 10.1118/1.4722983
    • P. T. Lauzier, J. Tang, M. A. Speidel, and G.-H. Chen, " Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging," Med. Phys. 39, 4079-4092 (2012). 10.1118/1.4722983
    • (2012) Med. Phys. , vol.39 , pp. 4079-4092
    • Lauzier, P.T.1    Tang, J.2    Speidel, M.A.3    Chen, G.-H.4
  • 38
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • DOI 10.1118/1.2789499
    • J.-B. Thibault, K. D. Sauer, C. A. Bouman, and J. Hsieh, " A three-dimensional statistical approach to improved image quality for multislice helical CT," Med. Phys. 34, 4526-4544 (2007). 10.1118/1.2789499 (Pubitemid 350029675)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4526-4544
    • Thibault, J.-B.1    Sauer, K.D.2    Bouman, C.A.3    Hsieh, J.4
  • 39
    • 0027542459 scopus 로고
    • Local update strategy for iterative reconstruction from projections
    • DOI 10.1109/78.193196
    • K. Sauer and C. Bouman, " A local update strategy for iterative reconstruction from projections," IEEE Trans. Signal Process. 41, 534-548 (1993). 10.1109/78.193196 (Pubitemid 23609319)
    • (1993) IEEE Transactions on Signal Processing , vol.41 , Issue.2 , pp. 534-549
    • Sauer Ken1    Bouman Charles2
  • 40
    • 0030109399 scopus 로고    scopus 로고
    • A unified approach to statistical tomography using coordinate descent optimization
    • PII S1057714996018003
    • C. A. Bouman and K. Sauer, " A unified approach to statistical tomography using coordinate descent optimization," IEEE Trans. Image Process. 5, 480-492 (1996). 10.1109/83.491321 (Pubitemid 126778108)
    • (1996) IEEE Transactions on Image Processing , vol.5 , Issue.3 , pp. 480-492
    • Bouman, C.A.1    Sauer, K.2
  • 42
    • 84855425876 scopus 로고    scopus 로고
    • Prior image constrained compressed sensing: Implementation and performance evaluation
    • 10.1118/1.3666946
    • P. T. Lauzier, J. Tang, and G.-H. Chen, " Prior image constrained compressed sensing: Implementation and performance evaluation," Med. Phys. 39, 66-80 (2012). 10.1118/1.3666946
    • (2012) Med. Phys. , vol.39 , pp. 66-80
    • Lauzier, P.T.1    Tang, J.2    Chen, G.-H.3
  • 43
    • 64649092845 scopus 로고    scopus 로고
    • Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke, Part 1: Theoretic basis
    • 10.3174/ajnr.A1487
    • A. Konstas, G. Goldmakher, T.-Y. Lee, and M. Lev, " Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke, Part 1: Theoretic basis," Am. J. Neuroradiol. 30, 662-668 (2009). 10.3174/ajnr.A1487
    • (2009) Am. J. Neuroradiol. , vol.30 , pp. 662-668
    • Konstas, A.1    Goldmakher, G.2    Lee, T.-Y.3    Lev, M.4
  • 44
    • 66849106746 scopus 로고    scopus 로고
    • Comparison of 10 perfusion MRI parameters in 97 sub-6-hour stroke patients using voxel-based receiver operating characteristics analysis
    • 10.1161/STROKEAHA.108.546069
    • S. Christensen, K. Mouridsen, O. Wu, N. Hjort, H. Karstoft, G. Thomalla, J. Röther, J. Fiehler, T. Kucinski, and L. Østergaard, " Comparison of 10 perfusion MRI parameters in 97 sub-6-hour stroke patients using voxel-based receiver operating characteristics analysis," Stroke 40, 2055-2061 (2009). 10.1161/STROKEAHA.108.546069
    • (2009) Stroke , vol.40 , pp. 2055-2061
    • Christensen, S.1    Mouridsen, K.2    Wu, O.3    Hjort, N.4    Karstoft, H.5    Thomalla, G.6    Röther, J.7    Fiehler, J.8    Kucinski, T.9    Østergaard, L.10
  • 45
    • 84872043005 scopus 로고    scopus 로고
    • Reduction of image noise in low tube current dynamic CT myocardial perfusion imaging using HYPR processing: A time-attenuation curve analysis
    • (8p). 10.1118/1.4770283
    • M. A. Speidel, C. L. Bateman, Y. Tao, A. N. Raval, T. A. Hacker, S. B. Reeder, and M. S. Van Lysel, " Reduction of image noise in low tube current dynamic CT myocardial perfusion imaging using HYPR processing: A time-attenuation curve analysis," Med. Phys. 40, 011904 (8pp.) (2013). 10.1118/1.4770283
    • (2013) Med. Phys. , vol.40 , pp. 011904
    • Speidel, M.A.1    Bateman, C.L.2    Tao, Y.3    Raval, A.N.4    Hacker, T.A.5    Reeder, S.B.6    Van Lysel, M.S.7
  • 46
    • 29944432651 scopus 로고    scopus 로고
    • Reduction of half-scan shading artifact based on full-scan correction
    • DOI 10.1016/j.acra.2005.08.007, PII S1076633205006380
    • J. A. Meinel, E. Hoffman, A. Clough, and G. Wang, " Reduction of half-scan shading artifact based on full-scan correction," Acad. Radiol. 13, 55-62 (2006). 10.1016/j.acra.2005.08.007 (Pubitemid 43041893)
    • (2006) Academic Radiology , vol.13 , Issue.1 , pp. 55-62
    • Meinel, J.A.1    Hoffman, E.2    Clough, A.3    Wang, G.4
  • 47
    • 72049095041 scopus 로고    scopus 로고
    • Partial scan artifact reduction (PSAR) for the assessment of cardiac perfusion in dynamic phase-correlated CT
    • 10.1118/1.3259734
    • P. Stenner, B. Schmidt, H. Bruder, T. Allmendinger, U. Haberland, T. Flohr, and M. Kachelriess, " Partial scan artifact reduction (PSAR) for the assessment of cardiac perfusion in dynamic phase-correlated CT," Med. Phys. 36, 5683-5694 (2009). 10.1118/1.3259734
    • (2009) Med. Phys. , vol.36 , pp. 5683-5694
    • Stenner, P.1    Schmidt, B.2    Bruder, H.3    Allmendinger, T.4    Haberland, U.5    Flohr, T.6    Kachelriess, M.7
  • 48
    • 84855425143 scopus 로고    scopus 로고
    • A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: Phantom and in vivo evaluation
    • 10.1118/1.3665767
    • J. C. Ramirez-Giraldo, L. Yu, B. Kantor, E. L. Ritman, and C. H. McCollough, " A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: Phantom and in vivo evaluation," Med. Phys. 39, 214-223 (2012). 10.1118/1.3665767
    • (2012) Med. Phys. , vol.39 , pp. 214-223
    • Ramirez-Giraldo, J.C.1    Yu, L.2    Kantor, B.3    Ritman, E.L.4    McCollough, C.H.5
  • 49
    • 84901645513 scopus 로고    scopus 로고
    • Investigation of the potential causes of partial scan artifacts in dynamic CT myocardial perfusion imaging
    • 10.1117/12.2043838
    • Y. Tao, M. Speidel, T. P. Szczykutowicz, and G.-H. Chen, " Investigation of the potential causes of partial scan artifacts in dynamic CT myocardial perfusion imaging," Proc. SPIE 9033, 90332B (2014). 10.1117/12.2043838
    • (2014) Proc. SPIE , vol.9033
    • Tao, Y.1    Speidel, M.2    Szczykutowicz, T.P.3    Chen, G.-H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.