메뉴 건너뛰기




Volumn 7, Issue 6, 2014, Pages 652-661

Erroneous measurement of the aortic annular diameter using 2-dimensional echocardiography resulting in inappropriate corevalve size selection: A retrospective comparison with multislice computed tomography

Author keywords

aortic stenosis; computed tomography; transcatheter aortic valve replacement; transcatheter heart valve; transesophageal echocardiography

Indexed keywords

IOMEPROL;

EID: 84902824474     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2014.02.010     Document Type: Article
Times cited : (50)

References (18)
  • 1
    • 84860436228 scopus 로고    scopus 로고
    • Registry of transcatheter aortic-valve implantation in high-risk patients
    • for the FRANCE 2 Investigators
    • M. Gilard, H. Eltchaninoff, B. Iung for the FRANCE 2 Investigators Registry of transcatheter aortic-valve implantation in high-risk patients N Engl J Med 366 2012 1705 1715
    • (2012) N Engl J Med , vol.366 , pp. 1705-1715
    • Gilard, M.1    Eltchaninoff, H.2    Iung, B.3
  • 2
    • 84860466759 scopus 로고    scopus 로고
    • Two-year outcomes after transcatheter or surgical aortic-valve replacement
    • for the PARTNER Trial Investigators
    • S.K. Kodali, M.R. Williams, C.R. Smith for the PARTNER Trial Investigators Two-year outcomes after transcatheter or surgical aortic-valve replacement N Engl J Med 366 2012 1686 1695
    • (2012) N Engl J Med , vol.366 , pp. 1686-1695
    • Kodali, S.K.1    Williams, M.R.2    Smith, C.R.3
  • 3
    • 84880355851 scopus 로고    scopus 로고
    • Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement
    • M. Barbanti, T.H. Yang, and J. Rodès Cabau et al. Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement Circulation 128 2013 244 253
    • (2013) Circulation , vol.128 , pp. 244-253
    • Barbanti, M.1    Yang, T.H.2    Rodès Cabau, J.3
  • 5
    • 80855144812 scopus 로고    scopus 로고
    • Multimodality imaging in transcatheter aortic valve implantation and post-procedural aortic regurgitation: Comparison among cardiovascular magnetic resonance, cardiac computed tomography, and echocardiography
    • A. Jabbour, T.F. Ismail, and N. Moat et al. Multimodality imaging in transcatheter aortic valve implantation and post-procedural aortic regurgitation: comparison among cardiovascular magnetic resonance, cardiac computed tomography, and echocardiography J Am Coll Cardiol 58 2011 2165 2173
    • (2011) J Am Coll Cardiol , vol.58 , pp. 2165-2173
    • Jabbour, A.1    Ismail, T.F.2    Moat, N.3
  • 6
    • 84859164235 scopus 로고    scopus 로고
    • Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation
    • H. Jilaihawi, M. Kashif, and G. Fontana et al. Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation J Am Coll Cardiol 59 2012 1275 1286
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1275-1286
    • Jilaihawi, H.1    Kashif, M.2    Fontana, G.3
  • 7
    • 84864215288 scopus 로고    scopus 로고
    • Aortic annulus sizing: Echocardiographic versus computed tomography derived measurements in comparison with direct surgical sizing
    • J. Kempfert, A. Van Linden, and L. Lehmkuhl et al. Aortic annulus sizing: echocardiographic versus computed tomography derived measurements in comparison with direct surgical sizing Eur J Cardiothorac Surg 42 2012 627 633
    • (2012) Eur J Cardiothorac Surg , vol.42 , pp. 627-633
    • Kempfert, J.1    Van Linden, A.2    Lehmkuhl, L.3
  • 8
    • 84871292882 scopus 로고    scopus 로고
    • Impact of CT-guided valve sizing on post-procedural aortic regurgitation in transcatheter aortic valve implantation
    • K. Hayashida, E. Bouvier, and T. Lefevre et al. Impact of CT-guided valve sizing on post-procedural aortic regurgitation in transcatheter aortic valve implantation EuroIntervention 8 2012 546 555
    • (2012) EuroIntervention , vol.8 , pp. 546-555
    • Hayashida, K.1    Bouvier, E.2    Lefevre, T.3
  • 9
    • 84859160648 scopus 로고    scopus 로고
    • 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: A multicenter retrospective analysis
    • A.B. Willson, J.G. Webb, and T.M. Labounty et al. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis J Am Coll Cardiol 59 2012 1287 1294
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1287-1294
    • Willson, A.B.1    Webb, J.G.2    Labounty, T.M.3
  • 10
    • 84856498981 scopus 로고    scopus 로고
    • Correlates on MSCT of paravalvular aortic regurgitation after transcatheter aortic valve implantation using the Medtronic CoreValve prosthesis
    • C.J. Schultz, A. Tzikas, and A. Moelker et al. Correlates on MSCT of paravalvular aortic regurgitation after transcatheter aortic valve implantation using the Medtronic CoreValve prosthesis Catheter Cardiovasc Interv 78 2011 446 455
    • (2011) Catheter Cardiovasc Interv , vol.78 , pp. 446-455
    • Schultz, C.J.1    Tzikas, A.2    Moelker, A.3
  • 11
    • 81855227692 scopus 로고    scopus 로고
    • Aortic annulus diameter determination by multidetector computed tomography: Reproducibility, applicability, and implications for transcatheter aortic valve implantation
    • R. Gurvitch, J.G. Webb, and R. Yuan et al. Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation J Am Coll Cardiol Intv 4 2011 1235 1245
    • (2011) J Am Coll Cardiol Intv , vol.4 , pp. 1235-1245
    • Gurvitch, R.1    Webb, J.G.2    Yuan, R.3
  • 12
    • 84855704273 scopus 로고    scopus 로고
    • Improvements in transcatheter aortic valve implantation outcomes in lower surgical risk patients: A glimpse into the future
    • R. Lange, S. Bleiziffer, and D. Mazzitelli et al. Improvements in transcatheter aortic valve implantation outcomes in lower surgical risk patients: a glimpse into the future J Am Coll Cardiol 59 2011 280 287
    • (2011) J Am Coll Cardiol , vol.59 , pp. 280-287
    • Lange, R.1    Bleiziffer, S.2    Mazzitelli, D.3
  • 14
    • 58149204388 scopus 로고    scopus 로고
    • Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice
    • H. Baumgartner, J. Hung, and J. Bermejo et al. Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice J Am Soc Echocardiogr 22 2009 1 23
    • (2009) J Am Soc Echocardiogr , vol.22 , pp. 1-23
    • Baumgartner, H.1    Hung, J.2    Bermejo, J.3
  • 15
    • 84872143850 scopus 로고    scopus 로고
    • Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document
    • for the Valve Academic Research Consortium-2
    • A.P. Kappetein, S.J. Head, P. Généreux for the Valve Academic Research Consortium-2 Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document EuroIntervention 8 2012 782 795
    • (2012) EuroIntervention , vol.8 , pp. 782-795
    • Kappetein, A.P.1    Head, S.J.2    Généreux, P.3
  • 16
    • 84877102732 scopus 로고    scopus 로고
    • Paravalvular leak after transcatheter aortic valve replacement: The new Achilles' heel? A comprehensive review of the literature
    • P. Généreux, S.J. Head, and R. Hahn et al. Paravalvular leak after transcatheter aortic valve replacement: the new Achilles' heel? A comprehensive review of the literature J Am Coll Cardiol 61 2013 1125 1136
    • (2013) J Am Coll Cardiol , vol.61 , pp. 1125-1136
    • Généreux, P.1    Head, S.J.2    Hahn, R.3
  • 17
    • 84867522550 scopus 로고    scopus 로고
    • Aortic annulus area assessment by multidetector computed tomography for predicting paravalvular regurgitation in patients undergoing balloon-expandable transcatheter aortic valve implantation: A comparison with transthoracic and transesophageal echocardiography
    • G. Pontone, D. Andreini, and A.L. Bartorelli et al. Aortic annulus area assessment by multidetector computed tomography for predicting paravalvular regurgitation in patients undergoing balloon-expandable transcatheter aortic valve implantation: a comparison with transthoracic and transesophageal echocardiography Am Heart J 164 2012 576 584
    • (2012) Am Heart J , vol.164 , pp. 576-584
    • Pontone, G.1    Andreini, D.2    Bartorelli, A.L.3
  • 18
    • 84893700681 scopus 로고    scopus 로고
    • Aortic annular sizing using a novel 3-dimensional echocardiographic method: Utility and comparison to cardiac computed tomography
    • O.K. Khalique, S. Kodali, and J.M. Paradis et al. Aortic annular sizing using a novel 3-dimensional echocardiographic method: utility and comparison to cardiac computed tomography Circ Cardiovasc Imaging 7 2014 155 163
    • (2014) Circ Cardiovasc Imaging , vol.7 , pp. 155-163
    • Khalique, O.K.1    Kodali, S.2    Paradis, J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.