-
1
-
-
34247590812
-
Clinical application of high and ultrahigh-field MRI
-
Nakada T,. Clinical application of high and ultrahigh-field MRI. Brain Dev 2007; 29: 325-335.
-
(2007)
Brain Dev
, vol.29
, pp. 325-335
-
-
Nakada, T.1
-
2
-
-
0035685766
-
Effect of RF coil excitation on field inhomogeneity at ultra high fields: A field optimized TEM resonator
-
Ibrahim TS, Lee R, Baertlein BA, Abduljalil AM, Zhu H, Robitaille P-ML,. Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator. Magn Reson Imaging 2001; 19: 1339-1347.
-
(2001)
Magn Reson Imaging
, vol.19
, pp. 1339-1347
-
-
Ibrahim, T.S.1
Lee, R.2
Baertlein, B.A.3
Abduljalil, A.M.4
Zhu, H.5
Robitaille, P.-M.6
-
4
-
-
0033945956
-
Sensitivity and power deposition in a high-field imaging experiment
-
Hoult DI,. Sensitivity and power deposition in a high-field imaging experiment. J Magn Reson Imaging 2000; 12: 46-67.
-
(2000)
J Magn Reson Imaging
, vol.12
, pp. 46-67
-
-
Hoult, D.I.1
-
5
-
-
0037223717
-
Transmit sense
-
Katscher U, Boernert P, Leussler CC, van den Brink JS,. Transmit sense. Magn Reson Med 2003; 49: 144-150.
-
(2003)
Magn Reson Med
, vol.49
, pp. 144-150
-
-
Katscher, U.1
Boernert, P.2
Leussler, C.C.3
Van Den Brink, J.S.4
-
6
-
-
1842586446
-
Parallel excitation with an array of transmit coils
-
Zhu Y,. Parallel excitation with an array of transmit coils. Magn Reson Med 2004; 51: 775-784.
-
(2004)
Magn Reson Med
, vol.51
, pp. 775-784
-
-
Zhu, Y.1
-
7
-
-
33748376498
-
Spatial domain method for the design of RF pulses in multicoil parallel excitation
-
Grissom W, Yip C, Zhang Z, Stenger VA, Fessler JA, Noll DC,. Spatial domain method for the design of RF pulses in multicoil parallel excitation. Magn Reson Med 2006; 56: 620-629.
-
(2006)
Magn Reson Med
, vol.56
, pp. 620-629
-
-
Grissom, W.1
Yip, C.2
Zhang, Z.3
Stenger, V.A.4
Fessler, J.A.5
Noll, D.C.6
-
8
-
-
84870060828
-
B1-based specific energy absorption rate determination for nonquadrature radiofrequency excitation
-
Katscher U, Findeklee C, Voigt T,. B1-based specific energy absorption rate determination for nonquadrature radiofrequency excitation. Magn Reson Med 2012; 68: 1911-1918.
-
(2012)
Magn Reson Med
, vol.68
, pp. 1911-1918
-
-
Katscher, U.1
Findeklee, C.2
Voigt, T.3
-
9
-
-
77955289545
-
B1-mapping by Bloch-Siegert shift
-
Sacolick LI, Wiesinger F, Hancu I, Vogel MW,. B1-mapping by Bloch-Siegert shift. Magn Reson Med 2010; 63: 1315-1322.
-
(2010)
Magn Reson Med
, vol.63
, pp. 1315-1322
-
-
Sacolick, L.I.1
Wiesinger, F.2
Hancu, I.3
Vogel, M.W.4
-
10
-
-
84867890773
-
DREAM a novel approach for robust, ultrafast, multislice B1 mapping
-
Nehrke K, Börnert P,. DREAM a novel approach for robust, ultrafast, multislice B1 mapping. Magn Reson Med 2012; 8: 1517-1526.
-
(2012)
Magn Reson Med
, vol.8
, pp. 1517-1526
-
-
Nehrke, K.1
Börnert, P.2
-
11
-
-
0025226022
-
The NMR phased array
-
Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM,. The NMR phased array. Magn Reson Med 1990; 16: 192-225.
-
(1990)
Magn Reson Med
, vol.16
, pp. 192-225
-
-
Roemer, P.B.1
Edelstein, W.A.2
Hayes, C.E.3
Souza, S.P.4
Mueller, O.M.5
-
12
-
-
7544231110
-
Parallel imaging performance as a function of field strength - An experimental investigation using electrodynamic scaling
-
Wiesinger F, Van de Moortele P-F, Adriany G, De Zanche N, Ugurbil K, Pruessmann KP,. Parallel imaging performance as a function of field strength-an experimental investigation using electrodynamic scaling. Magn Reson Med 2004; 52: 953-964.
-
(2004)
Magn Reson Med
, vol.52
, pp. 953-964
-
-
Wiesinger, F.1
Van De Moortele, P.-F.2
Adriany, G.3
De Zanche, N.4
Ugurbil, K.5
Pruessmann, K.P.6
-
13
-
-
0032712873
-
SENSE: Sensitivity encoding for fast MRI
-
Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P,. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999; 42: 952-962.
-
(1999)
Magn Reson Med
, vol.42
, pp. 952-962
-
-
Pruessmann, K.P.1
Weiger, M.2
Scheidegger, M.B.3
Boesiger, P.4
-
14
-
-
77957931700
-
An electromagnetic reverse method of coil sensitivity mapping for parallel MRI-theoretical framework
-
Jin J, Liu F, Weber E, Li Y, Crozier S,. An electromagnetic reverse method of coil sensitivity mapping for parallel MRI-theoretical framework. J Magn Reson 2010; 207: 59-68.
-
(2010)
J Magn Reson
, vol.207
, pp. 59-68
-
-
Jin, J.1
Liu, F.2
Weber, E.3
Li, Y.4
Crozier, S.5
-
15
-
-
34250364567
-
Joint image reconstruction and sensitivity estimation in SENSE (JSENSE)
-
Ying L, Sheng J,. Joint image reconstruction and sensitivity estimation in SENSE (JSENSE). Magn Reson Med 2007; 57: 1196-1202.
-
(2007)
Magn Reson Med
, vol.57
, pp. 1196-1202
-
-
Ying, L.1
Sheng, J.2
-
16
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
-
Sodickson DK, Manning WJ,. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997; 38: 591-603.
-
(1997)
Magn Reson Med
, vol.38
, pp. 591-603
-
-
Sodickson, D.K.1
Manning, W.J.2
-
18
-
-
84890795742
-
Robust reconstruction of B1+ maps by projection into a spherical functions space
-
Sbrizzi A, Hoogduin H, Lagendijk JJ, Luijten PR, van den Berg CAT,. Robust reconstruction of B1+ maps by projection into a spherical functions space. Magn Reson Med 2014; 71: 394-401.
-
(2014)
Magn Reson Med
, vol.71
, pp. 394-401
-
-
Sbrizzi, A.1
Hoogduin, H.2
Lagendijk, J.J.3
Luijten, P.R.4
Van Den Berg, C.A.T.5
-
20
-
-
80054803016
-
Design of a radiative surface coil array element at 7 T: The single-side adapted dipole antenna
-
Raaijmakers AJE, Ipek O, Klomp DWJ, Possanzini C, Harvey PR, Lagendijk JJW, van den Berg CAT,. Design of a radiative surface coil array element at 7 T: the single-side adapted dipole antenna. Magn Reson Med 2011; 66: 1488-1497.
-
(2011)
Magn Reson Med
, vol.66
, pp. 1488-1497
-
-
Raaijmakers, A.J.E.1
Ipek, O.2
Klomp, D.W.J.3
Possanzini, C.4
Harvey, P.R.5
Lagendijk, J.J.W.6
Van Den Berg, C.A.T.7
-
21
-
-
33846078031
-
Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field
-
Yarnykh VL,. Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magn Reson Med 2007; 57: 192-200.
-
(2007)
Magn Reson Med
, vol.57
, pp. 192-200
-
-
Yarnykh, V.L.1
-
22
-
-
84878111244
-
SENSE with improved tolerance to inaccuracies in coil sensitivity maps
-
Peeters JM, Fuderer M,. SENSE with improved tolerance to inaccuracies in coil sensitivity maps. Magn Reson Med 2013; 69: 1665-1669.
-
(2013)
Magn Reson Med
, vol.69
, pp. 1665-1669
-
-
Peeters, J.M.1
Fuderer, M.2
-
23
-
-
67049109394
-
B1(+) interferometry for the calibration of RF transmitter arrays
-
Brunner DO, Pruessmann KP,. B1(+) interferometry for the calibration of RF transmitter arrays. Magn Reson Med 2009; 61: 1480-1488.
-
(2009)
Magn Reson Med
, vol.61
, pp. 1480-1488
-
-
Brunner, D.O.1
Pruessmann, K.P.2
-
24
-
-
0030560293
-
A Jacobi-Davidson iteration method for linear eigenvalue problems
-
Sleijpen GLG, Van der Vorst HA,. A Jacobi-Davidson iteration method for linear eigenvalue problems. SIAM J Matrix Anal Appl 1996; 17: 401-425.
-
(1996)
SIAM J Matrix Anal Appl
, vol.17
, pp. 401-425
-
-
Sleijpen, G.L.G.1
Van Der Vorst, H.A.2
|