메뉴 건너뛰기




Volumn 17, Issue 5, 2013, Pages 811-817

Pulsatile flow decreases gaseous micro-bubble filtering properties of oxygenators without integrated arterial filters during cardiopulmonary bypass

Author keywords

Air embolism; Cardiopulmonary bypass; Pulsatile perfusion

Indexed keywords

ACUTE KIDNEY FAILURE; ACUTE LUNG INJURY; AGED; ANALYTICAL EQUIPMENT; ANALYTICAL PARAMETERS; ARTERIAL FILTER; ARTERIAL LINE; ARTICLE; BLOOD FILTRATION; BUBBLE COUNTER; CARDIOPULMONARY BYPASS; CLINICAL EFFECTIVENESS; CONTROLLED STUDY; CORONARY ARTERY BYPASS GRAFT; EQUIPMENT DESIGN; EXTRACORPOREAL MEMBRANE OXYGENATION DEVICE; FEMALE; FORWARD HEART FAILURE; GASEOUS MICRO BUBBLE NUMBER; GASEOUS MICRO BUBBLE VOLUME; GASEOUS MICROBUBBLE; HEART MUSCLE REVASCULARIZATION; HUMAN; LARGE OVER RANGED GASEOUS MICRO BUBBLE AMOUNT; MAJOR CLINICAL STUDY; MALE; MEMBRANE OXYGENATOR; MICROBUBBLE; NEUROLOGICAL COMPLICATION; NON PULSATILE PERFUSION; OUTCOME ASSESSMENT; PRESSURE GRADIENT; PRIORITY JOURNAL; PROSPECTIVE STUDY; PULSATILE FLOW; PULSATILE PERFUSION; RANDOMIZED CONTROLLED TRIAL; AIR EMBOLISM; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; EQUIPMENT; EXTRACORPOREAL OXYGENATION; ITALY; MIDDLE AGED; MORTALITY; TREATMENT OUTCOME;

EID: 84902395590     PISSN: 15699293     EISSN: 15699285     Source Type: Journal    
DOI: 10.1093/icvts/ivt264     Document Type: Article
Times cited : (17)

References (24)
  • 1
    • 27144506167 scopus 로고    scopus 로고
    • Microbubbles: Pathophysiology and clinical implications
    • Barak M, Katz Y. Microbubbles: Pathophysiology and clinical implications. Chest 2005;128:2918-32.
    • (2005) Chest , vol.128 , pp. 2918-2932
    • Barak, M.1    Katz, Y.2
  • 2
    • 76349095980 scopus 로고    scopus 로고
    • Protecting the brain from gaseous and solid microbubbles during coronary artery bypass grafting: A randomized controlled, trial
    • Gerriets T, Schwarz N, Sammer G, Baehr J, Stolz E, Kaps M et al. Protecting the brain from gaseous and solid microbubbles during coronary artery bypass grafting: A randomized controlled trial. Eur Heart J 2010;31:360-8.
    • (2010) Eur Heart J , vol.31 , pp. 360-368
    • Gerriets, T.1    Schwarz, N.2    Sammer, G.3    Baehr, J.4    Stolz, E.5    Kaps, M.6
  • 3
    • 33646844124 scopus 로고    scopus 로고
    • Relationship between white cell count, neuropsychologic outcome, and microemboli in 161 patients undergoing coronary artery bypass surgery
    • Whitaker D, Stygall J, Harrison M, Newman S. Relationship between white cell count, neuropsychologic outcome, and microemboli in 161 patients undergoing coronary artery bypass surgery. J Thorac Cardiovasc Surg 2006;131:1358-66.
    • (2006) J Thorac Cardiovasc, Surg , vol.131 , pp. 1358-1366
    • Whitaker, D.1    Stygall, J.2    Harrison, M.3    Newman, S.4
  • 4
    • 84862084804 scopus 로고    scopus 로고
    • Pulsatile flow during cardiopulmonary bypass preserves postoperative microcirculatory perfusion irrespective of systemic hemodynamics
    • Koning NJ, Vonk AB, van Barneveld LJ, Beishuizen A, Atasever B, van den Brom CE et al. Pulsatile flow during cardiopulmonary bypass preserves postoperative microcirculatory perfusion irrespective of systemic hemodynamics. J Appl Physiol 2012;112:1727-34.
    • (2012) J Appl Physiol , vol.112 , pp. 1727-1734
    • Koning, N.J.1    Vonk, A.B.2    Van Barneveld, L.J.3    Beishuizen, A.4    Atasever, B.5    Van Den Brom, C.E.6
  • 5
    • 84870038789 scopus 로고    scopus 로고
    • Pulsatile versus non-pulsatile flow during cardiopulmonary bypass: Microcirculatory and systemic effects
    • O'Neil MP, Fleming JC, Badhwar A, Guo LR. Pulsatile versus non-pulsatile flow during cardiopulmonary bypass: microcirculatory and systemic effects. Ann Thorac Surg 2012;94:2046-53.
    • (2012) Ann Thorac Surg , vol.94 , pp. 2046-2053
    • O'Neil, M.P.1    Fleming, J.C.2    Badhwar, A.3    Guo, L.R.4
  • 8
    • 0018717021 scopus 로고
    • Peripheral vascular resistance and angiotensin II levels during pulsatile and no-pulsatile cardiopulmonary bypass
    • Taylor KM, Bain WH, Russell M, Brannan JJ, Morton IJ. Peripheral vascular resistance and angiotensin II levels during pulsatile and no-pulsatile cardiopulmonary bypass. Thorax 1979;34:594-8.
    • (1979) Thorax , vol.34 , pp. 594-598
    • Taylor, K.M.1    Bain, W.H.2    Russell, M.3    Brannan, J.J.4    Morton, I.J.5
  • 9
    • 0034010554 scopus 로고    scopus 로고
    • Pulsatile flow enhances endothelium-derived nitric oxide release in the peripheral vasculature
    • Nakano T, Tominaga R, Nagano I, Okabe H, Yasui H. Pulsatile flow enhances endothelium-derived nitric oxide release in the peripheral vasculature. Am J Physiol Heart Circ Physiol 2000;278:H1098-104.
    • (2000) Am J Physiol Heart Circ Physiol , vol.278 , pp. H1098-H1104
    • Nakano, T.1    Tominaga, R.2    Nagano, I.3    Okabe, H.4    Yasui, H.5
  • 10
    • 0028318102 scopus 로고
    • Pulsatile flow and membrane oxygenators
    • Gourlay T, Taylor KM. Pulsatile flow and membrane oxygenators. Perfusion 1994;9:189-96.
    • (1994) Perfusion , vol.9 , pp. 189-196
    • Gourlay, T.1    Taylor, K.M.2
  • 11
    • 55949088780 scopus 로고    scopus 로고
    • Microemboli generation, detection and characterization during CPB procedures in neonates, infants, and small children
    • Win KN, Wang S, Undar A. Microemboli generation, detection and characterization during CPB procedures in neonates, infants, and small children. ASAIO J 2008;54:486-90.
    • (2008) ASAIO J , vol.54 , pp. 486-490
    • Win, K.N.1    Wang, S.2    Undar, A.3
  • 12
    • 84978706099 scopus 로고    scopus 로고
    • Revision 1.9 from March, Available from
    • GAMPT BCC200 Manual. Revision 1.9 from March 2013. Available from: http://www.gampt.de/content/cms/downloads/pdf/manuals/BCC200-manual.pdf.
    • (2013) GAMPT BCC200 Manual
  • 13
    • 40949143237 scopus 로고    scopus 로고
    • Impact of oxygenator characteristics on its capability to remove gaseous microemboli
    • De Somer F. Impact of oxygenator characteristics on its capability to remove gaseous microemboli. J Extra Corpor Technol 2007;39:271-3.
    • (2007) J Extra Corpor Technol , vol.39 , pp. 271-273
    • De Somer, F.1
  • 14
    • 39049184851 scopus 로고    scopus 로고
    • Vitro evaluation of the air separation ability of four cardiovascular manufacturer extracorporeal circuit designs
    • Dickinson TA, Riley JB, Crowley JC, Zabetakis PM. In vitro evaluation of the air separation ability of four cardiovascular manufacturer extracorporeal circuit designs. J Extra Corpor Technol 2006;38:206-13.
    • (2006) J Extra Corpor Technol , vol.38 , pp. 206-213
    • Dickinson, T.A.1    Riley, J.B.2    Crowley, J.C.3    Zabetakis, P.M.4
  • 15
    • 84862907730 scopus 로고    scopus 로고
    • In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters
    • Liu S, Newland RF, Tully PJ, Tuble SC, Baker RA. In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters. J Extra Corpor Technol 2011;43:107-14.
    • (2011) J Extra Corpor Technol , vol.43 , pp. 107-114
    • Liu, S.1    Newland, R.F.2    Tully, P.J.3    Tuble, S.C.4    Baker, R.A.5
  • 16
    • 76149129039 scopus 로고    scopus 로고
    • A clinical comparison of bubble elimination in Quadrox and Polystan oxygenators
    • Jirschik M, Keyl C, Beyersdorf F. A clinical comparison of bubble elimination in Quadrox and Polystan oxygenators. Perfusion 2009;24:423-7.
    • (2009) Perfusion , vol.24 , pp. 423-427
    • Jirschik, M.1    Keyl, C.2    Beyersdorf, F.3
  • 18
    • 78649426975 scopus 로고    scopus 로고
    • Blood temperature management and gaseous microemboli creation: An in-vitro analysis
    • Sleep J, Syhre I, Evans E. Blood temperature management and gaseous microemboli creation: An in-vitro analysis. J Extra Corpor Technol 2010;42: 219-22.
    • (2010) J Extra Corpor Technol , vol.42 , pp. 219-222
    • Sleep, J.1    Syhre, I.2    Evans, E.3
  • 20
    • 0031009313 scopus 로고    scopus 로고
    • A comparison of gaseous emboli release in five membrane oxygenators
    • Beckley PD, Shinko PD, Sites JP. A comparison of gaseous emboli release in five membrane oxygenators. Perfusion 1997;12:133-41.
    • (1997) Perfusion , vol.12 , pp. 133-141
    • Beckley, P.D.1    Shinko, P.D.2    Sites, J.P.3
  • 22
    • 0023933573 scopus 로고
    • The effect of arterial filtration on reduction of gaseous microemboli in the middle cerebral artery during cardiopulmonary bypass
    • Padayachee TS, Parsons S, Theobold R, Gosling RG, Deverall PB. The effect of arterial filtration on reduction of gaseous microemboli in the middle cerebral artery during cardiopulmonary bypass. Ann Thorac Surg 1988;45:647-9.
    • (1988) Ann Thorac Surg , vol.45 , pp. 647-649
    • Padayachee, T.S.1    Parsons, S.2    Theobold, R.3    Gosling, R.G.4    Deverall, P.B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.