메뉴 건너뛰기




Volumn 87, Issue 2, 2014, Pages 357-365

That's cool! - Nebulization of thermolabile proteins with a cooled vibrating mesh nebulizer

Author keywords

Active cooling; Fc RIIB; IgG; LDH; Nebulizer performance; PARI eFlow ; Protein stability; Vibrating mesh nebulization

Indexed keywords

IMMUNOGLOBULIN G1; LACTATE DEHYDROGENASE; MONOCLONAL ANTIBODY; PROTEIN DERIVATIVE; PROTEIN SM101; UNCLASSIFIED DRUG; AEROSOL; FC RECEPTOR; FCGR3B PROTEIN, HUMAN; GLYCOSYLPHOSPHATIDYLINOSITOL ANCHORED PROTEIN;

EID: 84902381555     PISSN: 09396411     EISSN: 18733441     Source Type: Journal    
DOI: 10.1016/j.ejpb.2014.03.001     Document Type: Article
Times cited : (27)

References (36)
  • 2
    • 69249120315 scopus 로고    scopus 로고
    • Lung deposition of inhaled α1-proteinase inhibitor in cystic fibrosis and α1-antitrypsin deficiency
    • P. Brand, M. Schulte, M. Wencker, C.H. Herpich, G. Klein, K. Hanna, and T. Meyer Lung deposition of inhaled α1-proteinase inhibitor in cystic fibrosis and α1-antitrypsin deficiency Eur. Respir. J. 34 2009 354 360
    • (2009) Eur. Respir. J. , vol.34 , pp. 354-360
    • Brand, P.1    Schulte, M.2    Wencker, M.3    Herpich, C.H.4    Klein, G.5    Hanna, K.6    Meyer, T.7
  • 5
    • 78650036519 scopus 로고    scopus 로고
    • A technical feasibility study of dornase alfa delivery with eflow® vibrating membrane nebulizers: Aerosol characteristics and physicochemical stability
    • T. Scherer, D.E. Geller, L. Owyang, M. Tservistas, M. Keller, N. Boden, K.C. Kesser, and S.J. Shire A technical feasibility study of dornase alfa delivery with eflow® vibrating membrane nebulizers: aerosol characteristics and physicochemical stability J. Pharm. Sci. 100 2011 98 109
    • (2011) J. Pharm. Sci. , vol.100 , pp. 98-109
    • Scherer, T.1    Geller, D.E.2    Owyang, L.3    Tservistas, M.4    Keller, M.5    Boden, N.6    Kesser, K.C.7    Shire, S.J.8
  • 6
    • 84867890649 scopus 로고    scopus 로고
    • Impact of lyoprotectants for the stabilization of biodegradable nanoparticles on the performance of air-jet, ultrasonic, and vibrating-mesh nebulizers
    • M. Beck-Broichsitter, P. Kleimann, T. Schmehl, T. Betz, U. Bakowsky, T. Kissel, and W. Seeger Impact of lyoprotectants for the stabilization of biodegradable nanoparticles on the performance of air-jet, ultrasonic, and vibrating-mesh nebulizers Eur. J. Pharm. Biopharm. 82 2012 272 280
    • (2012) Eur. J. Pharm. Biopharm. , vol.82 , pp. 272-280
    • Beck-Broichsitter, M.1    Kleimann, P.2    Schmehl, T.3    Betz, T.4    Bakowsky, U.5    Kissel, T.6    Seeger, W.7
  • 7
    • 42149119558 scopus 로고    scopus 로고
    • Advanced nebulizer designs employing vibrating mesh/aperture plate technologies for aerosol generation
    • J.C. Waldrep, and R. Dhand Advanced nebulizer designs employing vibrating mesh/aperture plate technologies for aerosol generation Curr. Drug Deliv. 5 2008 114 119
    • (2008) Curr. Drug Deliv. , vol.5 , pp. 114-119
    • Waldrep, J.C.1    Dhand, R.2
  • 8
    • 64549117379 scopus 로고    scopus 로고
    • Systemic treatment by inhalation of macromolecules - Principles, problems and examples
    • R. Siekmeier, and G. Scheuch Systemic treatment by inhalation of macromolecules - principles, problems and examples J. Physiol. Pharmacol. 59 2008 12
    • (2008) J. Physiol. Pharmacol. , vol.59 , pp. 12
    • Siekmeier, R.1    Scheuch, G.2
  • 9
    • 23644458446 scopus 로고    scopus 로고
    • The customised electronic nebuliser: A new category of liquid aerosol drug delivery systems
    • M. Knoch, and M. Keller The customised electronic nebuliser: a new category of liquid aerosol drug delivery systems Expert Opinion Drug Deliv. 2 2005 377 390
    • (2005) Expert Opinion Drug Deliv. , vol.2 , pp. 377-390
    • Knoch, M.1    Keller, M.2
  • 10
    • 52149103782 scopus 로고    scopus 로고
    • Current therapies and technological advances in aqueous aerosol drug delivery
    • A.B. Watts, J.T. McConville, and R.O. Williams Current therapies and technological advances in aqueous aerosol drug delivery Drug Dev. Ind. Pharm. 34 2008 913 922
    • (2008) Drug Dev. Ind. Pharm. , vol.34 , pp. 913-922
    • Watts, A.B.1    McConville, J.T.2    Williams, R.O.3
  • 11
    • 79958238207 scopus 로고    scopus 로고
    • A comparison of amount and speed of deposition between the PARI LC STAR® jet nebulizer and an investigational eFlow® nebulizer
    • A.L. Coates, M. Green, K. Leung, J. Chan, N. Ribeiro, F. Ratjen, and M. Charron A comparison of amount and speed of deposition between the PARI LC STAR® jet nebulizer and an investigational eFlow® nebulizer J. Aerosol Med. Pulm. Drug Deliv. 24 2011 157 163
    • (2011) J. Aerosol Med. Pulm. Drug Deliv. , vol.24 , pp. 157-163
    • Coates, A.L.1    Green, M.2    Leung, K.3    Chan, J.4    Ribeiro, N.5    Ratjen, F.6    Charron, M.7
  • 12
    • 84885000007 scopus 로고    scopus 로고
    • Vibrating membrane devices deliver aerosols more efficient than standard devices: A study in a neonatal upper airway model
    • S. Tiemersma, S. Minocchieri, R.A. van Lingen, M. Nelle, and S.G. Devadason Vibrating membrane devices deliver aerosols more efficient than standard devices: a study in a neonatal upper airway model J. Aerosol Med. Pulm. Drug Deliv. 26 2013 280 286
    • (2013) J. Aerosol Med. Pulm. Drug Deliv. , vol.26 , pp. 280-286
    • Tiemersma, S.1    Minocchieri, S.2    Van Lingen, R.A.3    Nelle, M.4    Devadason, S.G.5
  • 13
    • 33748652647 scopus 로고    scopus 로고
    • New advances in aerosolised drug delivery: Vibrating membrane nebuliser technology
    • J.S. Lass, A. Sant, and M. Knoch New advances in aerosolised drug delivery: vibrating membrane nebuliser technology Expert Opinion Drug Deliv. 3 2006 693 702
    • (2006) Expert Opinion Drug Deliv. , vol.3 , pp. 693-702
    • Lass, J.S.1    Sant, A.2    Knoch, M.3
  • 14
    • 33745595936 scopus 로고    scopus 로고
    • Comparison of a nebulizer using a novel aerosol generator with a standard ultrasonic nebulizer designed for use during mechanical ventilation
    • J.B. Fink, D. Schmidt, J. Power, Comparison of a nebulizer using a novel aerosol generator with a standard ultrasonic nebulizer designed for use during mechanical ventilation, in: American Thoracic Society 97th International Conference, San Fransisco, CA, 2001.
    • (2001) American Thoracic Society 97th International Conference, San Fransisco, CA
    • Fink, J.B.1    Schmidt, D.2    Power, J.3
  • 15
    • 84878149778 scopus 로고    scopus 로고
    • Characterization and quantitation of aggregates and particles in interferon-beta products: Potential links between product quality attributes and immunogenicity
    • J.G. Barnard, K. Babcock, and J.F. Carpenter Characterization and quantitation of aggregates and particles in interferon-beta products: potential links between product quality attributes and immunogenicity J. Pharm. Sci. 102 2013 915 928
    • (2013) J. Pharm. Sci. , vol.102 , pp. 915-928
    • Barnard, J.G.1    Babcock, K.2    Carpenter, J.F.3
  • 16
    • 33748041958 scopus 로고    scopus 로고
    • Effects of protein aggregates: An immunologic perspective
    • A. Rosenberg Effects of protein aggregates: an immunologic perspective AAPS J. 8 2006 E501 E507
    • (2006) AAPS J. , vol.8
    • Rosenberg, A.1
  • 18
    • 0028332576 scopus 로고
    • Protein nebulization: I. Stability of lactate dehydrogenase and recombinant granulocyte-colony stimulating factor to air-jet nebulization
    • R.W. Niven, A.Y. Ip, S.D. Mittelman, C. Farrar, T. Arakawa, and S.J. Prestrelski Protein nebulization: I. Stability of lactate dehydrogenase and recombinant granulocyte-colony stimulating factor to air-jet nebulization Int. J. Pharm. 109 1994 17 26
    • (1994) Int. J. Pharm. , vol.109 , pp. 17-26
    • Niven, R.W.1    Ip, A.Y.2    Mittelman, S.D.3    Farrar, C.4    Arakawa, T.5    Prestrelski, S.J.6
  • 20
    • 84902374123 scopus 로고    scopus 로고
    • Comparison of Aerosol Collection Methods for Liquid Protein Formulations
    • R.N. Dalby, P.R. Byron, J. Peart, J.D. Suman, P.M. Young (Eds.) Berlin
    • S.P. Hertel, W. Friess, G. Winter, Comparison of Aerosol Collection Methods for Liquid Protein Formulations, in: R.N. Dalby, P.R. Byron, J. Peart, J.D. Suman, P.M. Young (Eds.), RDD Europe 2011, Berlin, 2011, pp. 345-350.
    • (2011) RDD Europe 2011 , pp. 345-350
    • Hertel, S.P.1    Friess, W.2    Winter, G.3
  • 21
    • 0030917746 scopus 로고    scopus 로고
    • Measuring nebulizer output aerosol production vs gravimetric analysis
    • R. Tandon, M. McPeck, and G.C. Smaldone Measuring nebulizer output aerosol production vs gravimetric analysis CHEST J. 111 1997 1361 1365
    • (1997) CHEST J. , vol.111 , pp. 1361-1365
    • Tandon, R.1    McPeck, M.2    Smaldone, G.C.3
  • 22
    • 35148816278 scopus 로고    scopus 로고
    • A new system for understanding nebulizer performance
    • R.L. Chatburn, and M. McPeck A new system for understanding nebulizer performance Resp. Care 52 2007 1037 1050
    • (2007) Resp. Care , vol.52 , pp. 1037-1050
    • Chatburn, R.L.1    McPeck, M.2
  • 24
    • 42149169328 scopus 로고    scopus 로고
    • The mesh nebuliser: A recent technical innovation for aerosol delivery
    • L. Vecellio The mesh nebuliser: a recent technical innovation for aerosol delivery Breathe 2 2006 252 260
    • (2006) Breathe , vol.2 , pp. 252-260
    • Vecellio, L.1
  • 25
    • 0037433846 scopus 로고    scopus 로고
    • The effect of formulation variables on the stability of nebulized aviscumine
    • H. Steckel, F. Eskandar, and K. Witthohn The effect of formulation variables on the stability of nebulized aviscumine Int. J. Pharm. 257 2003 181 194
    • (2003) Int. J. Pharm. , vol.257 , pp. 181-194
    • Steckel, H.1    Eskandar, F.2    Witthohn, K.3
  • 26
    • 0029134661 scopus 로고
    • Stability of recombinant consensus interferon to air-jet and ultrasonic nebulization
    • A.Y. Ip, T. Arakawa, H. Silvers, C.M. Ransone, and R.W. Niven Stability of recombinant consensus interferon to air-jet and ultrasonic nebulization J. Pharm. Sci. 84 1995 1210 1214
    • (1995) J. Pharm. Sci. , vol.84 , pp. 1210-1214
    • Ip, A.Y.1    Arakawa, T.2    Silvers, H.3    Ransone, C.M.4    Niven, R.W.5
  • 27
    • 0030722056 scopus 로고    scopus 로고
    • Home nebulized therapy for patients with COPD patient compliance with treatment and its relation to quality of life
    • Z.M. Corden, C.M. Bosley, P.J. Rees, and G.M. Cochrane Home nebulized therapy for patients with COPD patient compliance with treatment and its relation to quality of life CHEST J. 112 1997 1278 1282
    • (1997) CHEST J. , vol.112 , pp. 1278-1282
    • Corden, Z.M.1    Bosley, C.M.2    Rees, P.J.3    Cochrane, G.M.4
  • 28
    • 33750724104 scopus 로고    scopus 로고
    • Clinical perspectives on pulmonary systemic and macromolecular delivery
    • G. Scheuch, M.J. Kohlhaeufl, P. Brand, and R. Siekmeier Clinical perspectives on pulmonary systemic and macromolecular delivery Adv. Drug Deliv. Rev. 58 2006 996 1008
    • (2006) Adv. Drug Deliv. Rev. , vol.58 , pp. 996-1008
    • Scheuch, G.1    Kohlhaeufl, M.J.2    Brand, P.3    Siekmeier, R.4
  • 29
    • 34250856236 scopus 로고    scopus 로고
    • The influence of fluid physicochemical properties on vibrating-mesh nebulization
    • T. Ghazanfari, A.M.A. Elhissi, Z. Ding, and K.M.G. Taylor The influence of fluid physicochemical properties on vibrating-mesh nebulization Int. J. Pharm. 339 2007 103 111
    • (2007) Int. J. Pharm. , vol.339 , pp. 103-111
    • Ghazanfari, T.1    Elhissi, A.M.A.2    Ding, Z.3    Taylor, K.M.G.4
  • 30
    • 84902371349 scopus 로고    scopus 로고
    • Influence of viscosity and surface tension on the nebulization efficiency of a jet (LC PLUS) and a vibrating membrane type nebulizer (e-Flow)
    • F.-C. Lintz, E. Walther, R. Waldner, M. Keller, Influence of viscosity and surface tension on the nebulization efficiency of a jet (LC PLUS) and a vibrating membrane type nebulizer (e-Flow), in: AAPS Annual Meeting, Denver, 2001.
    • (2001) AAPS Annual Meeting, Denver
    • Lintz, F.-C.1    Walther, E.2    Waldner, R.3    Keller, M.4
  • 31
    • 0000856457 scopus 로고
    • XLI. A theory of the viscosity of liquids - Part i
    • E.N.d.C. Andrade XLI. A theory of the viscosity of liquids - Part I Philos. Mag. Ser. 7 17 1934 497 511
    • (1934) Philos. Mag. Ser. , vol.7 , Issue.17 , pp. 497-511
    • Andrade D. N E, C.1
  • 32
    • 79960202513 scopus 로고    scopus 로고
    • Evaluation of the Nano Spray Dryer B-90 for pharmaceutical applications
    • K. Schmid, C. Arpagaus, and W. Friess Evaluation of the Nano Spray Dryer B-90 for pharmaceutical applications Pharm. Dev. Technol. 16 2011 287 294
    • (2011) Pharm. Dev. Technol. , vol.16 , pp. 287-294
    • Schmid, K.1    Arpagaus, C.2    Friess, W.3
  • 33
    • 85027929643 scopus 로고    scopus 로고
    • The role of polysorbate 80 and HPbetaCD at the air-water interface of IgG solutions
    • T. Serno, E. Hartl, A. Besheer, R. Miller, and G. Winter The role of polysorbate 80 and HPbetaCD at the air-water interface of IgG solutions Pharm. Res. 30 2013 117 130
    • (2013) Pharm. Res. , vol.30 , pp. 117-130
    • Serno, T.1    Hartl, E.2    Besheer, A.3    Miller, R.4    Winter, G.5
  • 35
    • 0029914615 scopus 로고    scopus 로고
    • Protein nebulization II. Stabilization of G-CSF to air-jet nebulization and the role of protectants
    • R.W. Niven, S.J. Prestrelski, M.J. Treuheit, A.Y. Ip, and T. Arakawa Protein nebulization II. Stabilization of G-CSF to air-jet nebulization and the role of protectants Int. J. Pharm. 127 1996 191 201
    • (1996) Int. J. Pharm. , vol.127 , pp. 191-201
    • Niven, R.W.1    Prestrelski, S.J.2    Treuheit, M.J.3    Ip, A.Y.4    Arakawa, T.5
  • 36
    • 84902368367 scopus 로고    scopus 로고
    • Prediction of protein degradation during vibrating mesh nebulization via a high throughput screening method
    • S.P. Hertel, T. Pohl, W. Friess, G. Winter, Prediction of protein degradation during vibrating mesh nebulization via a high throughput screening method, Eur. J. Pharm. Biopharm. 87 (2014) 386-394.
    • (2014) Eur. J. Pharm. Biopharm. , vol.87 , pp. 386-394
    • Hertel, S.P.1    Pohl, T.2    Friess, W.3    Winter, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.