메뉴 건너뛰기




Volumn 216, Issue , 2014, Pages 19-27

Trace-moisture generator designed for performance tests of trace-moisture analyzers

Author keywords

Diffusion tube method; Dilution method; Humidity standard; Metrological traceability; Sensor test; Sonic nozzle

Indexed keywords

ABSORPTION SPECTROSCOPY; EVAPORATION; FLOW RATE; MOISTURE METERS; NITROGEN; NOZZLES; TUBES (COMPONENTS);

EID: 84901923656     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2014.05.002     Document Type: Article
Times cited : (12)

References (15)
  • 2
    • 0142134399 scopus 로고    scopus 로고
    • Techniques for the measurement of trace moisture in high-purity electronic specialty gases
    • H.H. Funke, B.L. Grissom, C.E. McGrew, and M.W. Raynor Techniques for the measurement of trace moisture in high-purity electronic specialty gases Rev. Sci. Instrum. 74 2003 3909 3933
    • (2003) Rev. Sci. Instrum. , vol.74 , pp. 3909-3933
    • Funke, H.H.1    Grissom, B.L.2    McGrew, C.E.3    Raynor, M.W.4
  • 4
    • 33745656416 scopus 로고    scopus 로고
    • Modeling of rates of moisture ingress into photovoltaic modules
    • DOI 10.1016/j.solmat.2006.04.002, PII S0927024806001632
    • M.D. Kempe Modeling of rates of moisture ingress into photovoltaic modules Sol. Energy Mater. Sol. Cells 90 2006 2720 2738 (Pubitemid 43975758)
    • (2006) Solar Energy Materials and Solar Cells , vol.90 , Issue.16 , pp. 2720-2738
    • Kempe, M.D.1
  • 5
    • 33645145846 scopus 로고    scopus 로고
    • Development of humidity standard in trace-moisture region: Characteristics of humidity generation of diffusion tube humidity generator
    • H. Abe, and H. Kitano Development of humidity standard in trace-moisture region: characteristics of humidity generation of diffusion tube humidity generator Sens. Actuators A 128 2006 202 208
    • (2006) Sens. Actuators A , vol.128 , pp. 202-208
    • Abe, H.1    Kitano, H.2
  • 6
    • 77649333167 scopus 로고    scopus 로고
    • A marked improvement in the reliability of the measurement of trace moisture in gases
    • H. Abe A marked improvement in the reliability of the measurement of trace moisture in gases Synthesiology 2 2009 206 220
    • (2009) Synthesiology , vol.2 , pp. 206-220
    • Abe, H.1
  • 7
    • 29144464162 scopus 로고
    • Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources
    • A. O'Keefe, and D.A.G. Deacon Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources Rev. Sci. Instrum. 59 1988 2544 2551
    • (1988) Rev. Sci. Instrum. , vol.59 , pp. 2544-2551
    • O'Keefe, A.1    Deacon, D.A.G.2
  • 8
    • 0000605771 scopus 로고
    • Ring-down cavity absorption spectroscopy of the very weak HCN overtone bands with six, seven, and eight stretching quanta
    • D. Romanini, and K.K. Lehmann Ring-down cavity absorption spectroscopy of the very weak HCN overtone bands with six, seven, and eight stretching quanta J. Chem. Phys. 99 1993 6287 6301
    • (1993) J. Chem. Phys. , vol.99 , pp. 6287-6301
    • Romanini, D.1    Lehmann, K.K.2
  • 9
    • 0034536080 scopus 로고    scopus 로고
    • Cavity ring-down spectroscopy: Experimental schemes and applications
    • DOI 10.1080/014423500750040627
    • G. Berden, R. Peeters, and G. Meijer Cavity ring-down spectroscopy: experimental schemes and applications Int. Rev. Phys. Chem. 19 2000 565 607 (Pubitemid 32057800)
    • (2000) International Reviews in Physical Chemistry , vol.19 , Issue.4 , pp. 565-607
    • Berden, G.1    Peeters, R.2    Meijer, G.3
  • 14
    • 37549037111 scopus 로고    scopus 로고
    • Treatment of uncorrected measurement bias in uncertainty estimation for chemical measurements
    • B. Magnusson, and S.L.R. Ellison Treatment of uncorrected measurement bias in uncertainty estimation for chemical measurements Anal. Bioanal. Chem. 390 2008 201 213
    • (2008) Anal. Bioanal. Chem. , vol.390 , pp. 201-213
    • Magnusson, B.1    Ellison, S.L.R.2
  • 15
    • 79951515960 scopus 로고    scopus 로고
    • Performance evaluation of a trace-moisture analyzer based on cavity ring-down spectroscopy: Direct comparison with the NMIJ trace-moisture standard
    • H. Abe, and K.M.T. Yamada Performance evaluation of a trace-moisture analyzer based on cavity ring-down spectroscopy: direct comparison with the NMIJ trace-moisture standard Sens. Actuators A 165 2011 230 238
    • (2011) Sens. Actuators A , vol.165 , pp. 230-238
    • Abe, H.1    Yamada, K.M.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.