메뉴 건너뛰기




Volumn 2, Issue 3, 2009, Pages 206-220

A marked improvement in the reliability of the measurement of trace moisture in gases

Author keywords

Humidity; Metrological traceability; Primary measurement standard; Reliability; Trace moisture

Indexed keywords


EID: 77649333167     PISSN: 18830978     EISSN: None     Source Type: Journal    
DOI: 10.5571/syntheng.2.206     Document Type: Article
Times cited : (20)

References (24)
  • 2
    • 85036789878 scopus 로고    scopus 로고
    • 3 gas on nitride-semiconductor films grown by metal organic vapor phase epitaxy, Taiyo Nissan Giho
    • in Japanese
    • Y. Kobayashi, H. Mangyo, H. Ono, T. Ikeda, K. Ikenaga, I. Matsumoto, K. Sugihara and K. Shibuya: Effects of Moisture Impurities in NH3 Gas on Nitride-Semiconductor Films Grown by Metal Organic Vapor Phase Epitaxy, Taiyo Nissan Giho (Technical Report of Taiyo Nissan) , 26, 1-6 (2007) (in Japanese). http://www.tn-sanso.co.jp/jp/rd/report26.html
    • (2007) Technical Report of Taiyo Nissan , vol.26 , pp. 1-6
    • Kobayashi, Y.1    Mangyo, H.2    Ono, H.3    Ikeda, T.4    Ikenaga, K.5    Matsumoto, I.6    Sugihara, K.7    Shibuya, K.8
  • 3
    • 0142134399 scopus 로고    scopus 로고
    • Techniques for the measurement of trace moisture in high-purity electronic specialty gases
    • H. H. Funke, B. L. Grissom, C. E. McGrew and M. W. Raynor: Techniques for the measurement of trace moisture in high-purity electronic specialty gases, Rev. Sci. Instrum., 74, 3909-3933 (2003).
    • (2003) Rev. Sci. Instrum. , vol.74 , pp. 3909-3933
    • Funke, H.H.1    Grissom, B.L.2    McGrew, C.E.3    Raynor, M.W.4
  • 5
    • 33645145846 scopus 로고    scopus 로고
    • Development of humidity standard in trace-moisture region: Characteristics of humidity generation of diffusion tube humidity generator
    • H. Abe and H. Kitano: Development of humidity standard in trace-moisture region: Characteristics of humidity generation of diffusion tube humidity generator, Sens. Actuators A, 128, 202-208 (2006).
    • (2006) Sens. Actuators A , vol.128 , pp. 202-208
    • Abe, H.1    Kitano, H.2
  • 6
    • 0039084081 scopus 로고
    • 2 -free moist air
    • Phys. and Chem.
    • L. G reenspan: Functional equations for the enhancement factors for CO2-free moist air, J. Res. Nat. Bur. Stands., 80A (Phys. and Chem.), 41-44 (1976).
    • (1976) J. Res. Nat. Bur. Stands. , vol.80 A , pp. 41-44
    • Greenspan, L.1
  • 8
    • 0000192865 scopus 로고
    • Important new values of the physical constants of 1 986, vapor pressure formulations based on the ITS- 90, and psychrometer formulae
    • D. Sonntag: Important new values of the physical constants of 1 986, vapor pressure formulations based on the ITS- 90, and psychrometer formulae, Z. Meteorol. , 70, 340-344 (1990).
    • (1990) Z. Meteorol. , Issue.70 , pp. 340-344
    • Sonntag, D.1
  • 9
    • 77649322300 scopus 로고    scopus 로고
    • Evaluation of fundamental data used in humidity metrology
    • S. Boyes and S. Bell: Evaluation of fundamental data used in humidity metrology, NPL Report , CMAM 42 (1999).
    • (1999) NPL Report , vol.CMAM , pp. 42
    • Boyes, S.1    Bell, S.2
  • 10
    • 85036798936 scopus 로고    scopus 로고
    • International Technology Road map for Sem iconductors 2000 Update, http://www.itrs.net/Links/2000UpdateFinal/2kUdFinal.html
    • (2000) Update
  • 11
    • 85036794846 scopus 로고    scopus 로고
    • Rubotherm, http://www.rubotherm.de/
  • 14
    • 29144464162 scopus 로고
    • Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources
    • A. O'Keefe and D. A. G. Deacon: Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources, Rev. Sci. Instrum. , 59, 2544-2551 (1988).
    • (1988) Rev. Sci. Instrum. , vol.59 , pp. 2544-2551
    • O'Keefe, A.1    Deacon, D.A.G.2
  • 15
    • 0034536080 scopus 로고    scopus 로고
    • Cavity ring-down spectroscopy: Experimental schemes and applications
    • G. Berden, R. Peeters and G. Meijer: Cavity ring-down spectroscopy: Experimental schemes and applications, Int. Rev. Phys. Chem. , 19, 565-607 (2000).
    • (2000) Int. Rev. Phys. Chem. , vol.19 , pp. 565-607
    • Berden, G.1    Peeters, R.2    Meijer, G.3
  • 17
    • 77649292319 scopus 로고    scopus 로고
    • Detection of trace species with cavity ring-down spectroscopy
    • in Japanese
    • M. Kawasaki and S. Ebata: Detection of Trace Species with Cavity Ring-Down Spectroscopy, Reza Kenkyu (The Review of Laser Engineering), 34 (4), 289-294 (2006) (in Japanese).
    • (2006) Reza Kenkyu (The Review of Laser Engineering) , vol.34 , Issue.4 , pp. 289-294
    • Kawasaki, M.1    Ebata, S.2
  • 19
    • 0031170944 scopus 로고    scopus 로고
    • Development of a calibration facility for small mass flow rates of gas and the uncertainty of a sonic venturi transfer standard
    • S. Nakao, Y. Yokoi and M. Takamoto: Development of a calibration facility for small mass flow rates of gas and the uncertainty of a sonic venturi transfer standard, Flow Meas. Instrum., 7, 77-83 (1996).
    • (1996) Flow Meas. Instrum. , vol.7 , pp. 77-83
    • Nakao, S.1    Yokoi, Y.2    Takamoto, M.3
  • 20
    • 0034577102 scopus 로고    scopus 로고
    • Using small sonic nozzles as secondary flow standards
    • N. Bignell: Using small sonic nozzles as secondary flow standards, Flow Meas. Instrum., 11, 329-337 (2000).
    • (2000) Flow Meas. Instrum. , vol.11 , pp. 329-337
    • Bignell, N.1
  • 21
    • 0034571805 scopus 로고    scopus 로고
    • Development of a transfer standard with sonic venturi nozzles for small mass f low rates of gases
    • M. Hayakawa, Y. Ina, Y. Yokoi, M. Takamoto and S. Nakao: Development of a transfer standard with sonic venturi nozzles for small mass f low rates of gases, Flow Meas. Instrum., 11, 279-283 (2000).
    • (2000) Flow Meas. Instrum. , vol.11 , pp. 279-283
    • Hayakawa, M.1    Ina, Y.2    Yokoi, Y.3    Takamoto, M.4    Nakao, S.5
  • 22
    • 34247584007 scopus 로고    scopus 로고
    • Improvement of flow and pressure controls in diffusion-tube humidity generator: Performance evaluation trace-moisture generation using cavity ring-down spectroscopy
    • H. Abe and H. Kitano: Improvement of flow and pressure controls in diffusion-tube humidity generator: Performance evaluation trace-moisture generation using cavity ring-down spectroscopy: Sens. Actuators A , 136, 723-729 (2007).
    • (2007) Sens. Actuators A , vol.136 , pp. 723-729
    • Abe, H.1    Kitano, H.2
  • 23
    • 52349116480 scopus 로고    scopus 로고
    • Uncertainty analysis of vaporization rate in magnetic suspension balance/ diffusiontube humidity generator
    • H. Abe, H. Tanaka and H. Kitano: Uncertainty analysis of vaporization rate in magnetic suspension balance/ diffusiontube humidity generator, Int. J. Thermophys. , 29, 1555-1566 (2008).
    • (2008) Int. J. Thermophys. , vol.29 , pp. 1555-1566
    • Abe, H.1    Tanaka, H.2    Kitano, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.