Current clinical issues for MRI scanning of pacemaker and defibrillator patients
-
Kalin R, Stanton MS. Current clinical issues for MRI scanning of pacemaker and defibrillator patients. Pacing Clin Electrophysiol. 2005;28:326-8.
-
(2005)
Pacing Clin Electrophysiol.
, vol.28
, pp. 326-328
-
-
Kalin, R.1
Stanton, M.S.2
-
2
-
-
79551528450
-
Pacemaker lead tip heating in abandoned and pacemaker-attached leads at 1.5 Tesla MRI
-
Langman DA, Goldberg IB, Finn JP, et al. Pacemaker lead tip heating in abandoned and pacemaker-attached leads at 1.5 Tesla MRI. J Magn Reson Imaging. 2011;33:426-31.
-
(2011)
J Magn Reson Imaging.
, vol.33
, pp. 426-431
-
-
Langman, D.A.1
Goldberg, I.B.2
Finn, J.P.3
-
3
-
-
84883820202
-
Not all pacemakers are created equal:MRI conditional pacemaker and lead technology
-
Ahmed FZ, MorrisGM, Allen S, et al. Not all pacemakers are created equal:MRI conditional pacemaker and lead technology. J Cardiovasc Electrophysiol. 2013;24(9):1059-65.
-
(2013)
J Cardiovasc Electrophysiol.
, vol.24
, Issue.9
, pp. 1059-1065
-
-
Ahmed, F.Z.1
Morris, G.M.2
Allen, S.3
-
4
-
-
84880937087
-
ESC guidelines on cardiac pacing and cardiac resynchronization therapy: The task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA)
-
Brignole M, Auricchio A, Baron-Esquivias G, et al. ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Europace. 2013;15(8):1070-118.
-
(2013)
Europace.
, vol.15
, Issue.8
, pp. 1070-1118
-
-
Brignole, M.1
Auricchio, A.2
Baron-Esquivias, G.3
-
5
-
-
79952804179
-
Cardiovascular magnetic resonance physics for clinicians: Part 1
-
Ridgway JP. Cardiovascular magnetic resonance physics for clinicians: part 1. J Cardiovasc Magn Reson. 2010;12:71.
-
(2010)
J Cardiovasc Magn Reson.
, vol.12
, pp. 71
-
-
Ridgway, J.P.1
-
6
-
-
77149160028
-
Magnetic resonance imaging, pacemakers and implantable cardioverter-defibrillators: Current situation and clinical perspective
-
Götte MJW, Rüssel IK, de Roest GJ, et al. Magnetic resonance imaging, pacemakers and implantable cardioverter-defibrillators: current situation and clinical perspective. Neth Heart J. 2010;18:31-7.
-
(2010)
Neth Heart J.
, vol.18
, pp. 31-37
-
-
Götte, M.J.W.1
Rüssel, I.K.2
de Roest, G.J.3
-
7
-
-
84878233572
-
Crown years for non-invasive cardiovascular imaging (Part III): 30 years cardiovascular magnetic resonance
-
van der Wall EE. Crown years for non-invasive cardiovascular imaging (Part III): 30 years cardiovascular magnetic resonance. Neth Heart J. 2013;21(6):263-5.
-
(2013)
Neth Heart J.
, vol.21
, Issue.6
, pp. 263-265
-
-
van der Wall, E.E.1
-
8
-
-
0020638735
-
The effects of nuclear magnetic resonance on patients with cardiac pacemakers
-
Pavlicek W, Geisinger M, Castle L, et al. The effects of nuclear magnetic resonance on patients with cardiac pacemakers. Radiology. 1983;147(1):149-53.
-
(1983)
Radiology.
, vol.147
, Issue.1
, pp. 149-153
-
-
Pavlicek, W.1
Geisinger, M.2
Castle, L.3
-
9
-
-
0035098415
-
Force and torque effects of a 1.5 Tesla MRI scanner on cardiac pacemakers and ICD's
-
Luechinger R, Duru F, Scheidegger MB, et al. Force and torque effects of a 1.5 Tesla MRI scanner on cardiac pacemakers and ICD's. Pacing Clin Electrophysiol. 2001;24:199-205.
-
(2001)
Pacing Clin Electrophysiol.
, vol.24
, pp. 199-205
-
-
Luechinger, R.1
Duru, F.2
Scheidegger, M.B.3
-
10
-
-
14144252694
-
In vivo heating of pacemaker leads during magnetic resonance imaging
-
Luechinger R, Zeijlemaker VA, Pederson EM, et al. In vivo heating of pacemaker leads during magnetic resonance imaging. Eur Heart J. 2004;26:376-83.
-
(2004)
Eur Heart J.
, vol.26
, pp. 376-383
-
-
Luechinger, R.1
Zeijlemaker, V.A.2
Pederson, E.M.3
-
11
-
-
84896721493
-
Cardiac MRI of patients with implanted electrical cardiac devices
-
doi:10.1136/ heartjnl-2013-304324
-
Ainslie M, Miller C, Brown B, et al. Cardiac MRI of patients with implanted electrical cardiac devices. Heart. 2013;0:1-7. doi:10.1136/ heartjnl-2013-304324.
-
(2013)
Heart.
, vol.0
, pp. 1-7
-
-
Ainslie, M.1
Miller, C.2
Brown, B.3
-
12
-
-
33644809598
-
Safe scanning, but frequent artifacts mimicking bradycardia and tachycardia during magnetic resonance imaging (MRI) in patients with an implantable loop recorder (ILR)
-
Gimbel JR, Zarghami J, Machado C, et al. Safe scanning, but frequent artifacts mimicking bradycardia and tachycardia during magnetic resonance imaging (MRI) in patients with an implantable loop recorder (ILR). Ann Noninvasive Electrocardiol. 2005;10(4):404-8.
-
(2005)
Ann Noninvasive Electrocardiol.
, vol.10
, Issue.4
, pp. 404-408
-
-
Gimbel, J.R.1
Zarghami, J.2
McHado, C.3
-
13
-
-
40149092828
-
Feasibility of magnetic resonance imaging in patients with an implantable loop recorder
-
Wong JA, Yee R, Gula LJ, et al. Feasibility of magnetic resonance imaging in patients with an implantable loop recorder. Pacing Clin Electrophysiol. 2008;31(3):333-7.
-
(2008)
Pacing Clin Electrophysiol.
, vol.31
, Issue.3
, pp. 333-337
-
-
Wong, J.A.1
Yee, R.2
Gula, L.J.3
-
14
-
-
0021167926
-
The effects of nuclear magnetic resonance imagers on external and implantable pulse generators
-
Fetter J, Aram G, Holmes DR, et al. The effects of nuclear magnetic resonance imagers on external and implantable pulse generators. Pacing Clin Electrophysiol. 1984;7:720-7.
-
(1984)
Pacing Clin Electrophysiol.
, vol.7
, pp. 720-727
-
-
Fetter, J.1
Aram, G.2
Holmes, D.R.3
-
15
-
-
0029969886
-
Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers
-
Gimbel JR, Johnson D, Levine PA, et al. Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers. Pacing Clin Electrophysiol. 1996;19(6):913-9.
-
(1996)
Pacing Clin Electrophysiol.
, vol.19
, Issue.6
, pp. 913-919
-
-
Gimbel, J.R.1
Johnson, D.2
Levine, P.A.3
-
16
-
-
0031839080
-
Rapid ventricular pacing in a pacemaker patient undergoing magnetic resonance imaging
-
Fontaine JM, Mohamed FB, Gottlieb C, et al. Rapid ventricular pacing in a pacemaker patient undergoing magnetic resonance imaging. Pacing Clin Electrophysiol. 1998;21:1336-9.
-
(1998)
Pacing Clin Electrophysiol.
, vol.21
, pp. 1336-1339
-
-
Fontaine, J.M.1
Mohamed, F.B.2
Gottlieb, C.3
-
17
-
-
0034077462
-
MRI and cardiac pacemakers: In-vitro evaluation and in vivo studies in 51 patients at 0.5 T
-
Sommer T, Vahlhaus C, Lauck G, et al. MRI and cardiac pacemakers: in-vitro evaluation and in vivo studies in 51 patients at 0.5 T. Radiology. 2000;215:869-79.
-
(2000)
Radiology.
, vol.215
, pp. 869-879
-
-
Sommer, T.1
Vahlhaus, C.2
Lauck, G.3
-
18
-
-
0035030124
-
Interference with cardiac pacemakers by magnetic resonance imaging: Are there irreversible changes at 0.5 T?
-
Vahlhaus C, Sommer T, Lewalter T, et al. Interference with cardiac pacemakers by magnetic resonance imaging: are there irreversible changes at 0.5 T? Pacing Clin Electrophysiol. 2001;24:489-95.
-
(2001)
Pacing Clin Electrophysiol.
, vol.24
, pp. 489-495
-
-
Vahlhaus, C.1
Sommer, T.2
Lewalter, T.3
-
19
-
-
20344404247
-
Unexpected sudden death of pacemaker patients during or shortly after magnetic resonance imaging [MRI]
-
In, Milan, Italy, 3-6 September174, Abstract no. 114
-
Bartsch C, IrnichW, RisseM, Weiler G. Unexpected sudden death of pacemaker patients during or shortly after magnetic resonance imaging [MRI]. In: XIX Congress of International Academy of Legal Medicine. Milan, Italy, 3-6 September 2003. 174, Abstract no. 114
-
(2003)
XIX Congress of International Academy of Legal Medicine
-
-
Bartsch, C.1
Irnich, W.2
Risse, M.3
Weiler, G.4
-
20
-
-
20344387680
-
Do we need pacemakers resistant to magnetic resonance imaging?
-
IrnichW, Irnich B, Bartsch C, et al. Do we need pacemakers resistant to magnetic resonance imaging? Europace. 2005;7(4):353-65.
-
(2005)
Europace
, vol.7
, Issue.4
, pp. 353-365
-
-
Irnich, W.1
Irnich, B.2
Bartsch, C.3
-
21
-
-
67651016691
-
Magnetic resonance imaging at 1.5-T in patients with implantable cardioverter-defibrillators
-
Naehle CP, Strach K, Thomas D, et al. Magnetic resonance imaging at 1.5-T in patients with implantable cardioverter-defibrillators. J Am Coll Cardiol. 2009;54(6):549-55.
-
(2009)
J Am Coll Cardiol.
, vol.54
, Issue.6
, pp. 549-555
-
-
Naehle, C.P.1
Strach, K.2
Thomas, D.3
-
22
-
-
80053531595
-
A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices
-
Nazarian S, Hansford R, Roguin A, et al. A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices. Ann Intern Med. 2011;155:415-24.
-
(2011)
Ann Intern Med.
, vol.155
, pp. 415-424
-
-
Nazarian, S.1
Hansford, R.2
Roguin, A.3
-
23
-
-
59149092325
-
Safety of magnetic resonance imaging of patients with a newMedtronic EnRhythmMRI SureScan pacing system: Clinical study design
-
Sutton R, Kanal E, Wilkoff BL, et al. Safety of magnetic resonance imaging of patients with a newMedtronic EnRhythmMRI SureScan pacing system: clinical study design. Trials. 2008;9:68.
-
(2008)
Trials.
, vol.9
, pp. 68
-
-
Sutton, R.1
Kanal, E.2
Wilkoff, B.L.3
-
24
-
-
78650670809
-
Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment
-
Wilkoff BL, Bello D, TaborskyM, et al. Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment. Heart Rhythm. 2011;8(1):65-73.
-
(2011)
Heart Rhythm.
, vol.8
, Issue.1
, pp. 65-73
-
-
Wilkoff, B.L.1
Bello, D.2
Taborsky, M.3
-
26
-
-
84858200380
-
MRI in patients with cardiac implantable electronic devices
-
Cronin EM, Mahon N, Wilkoff BL. MRI in patients with cardiac implantable electronic devices. Expert Rev Med Devices. 2012;9(2): 139-46.
-
(2012)
Expert Rev Med Devices.
, vol.9
, Issue.2
, pp. 139-146
-
-
Cronin, E.M.1
Mahon, N.2
Wilkoff, B.L.3
-
27
-
-
84869089727
-
Determining the risks of magnetic resonance imaging at 1.5 tesla for patients with pacemakers and implantable cardioverter defibrillators
-
Cohen JD, Costa HS, Russo RJ. Determining the risks of magnetic resonance imaging at 1.5 tesla for patients with pacemakers and implantable cardioverter defibrillators. Am J Cardiol. 2012;110:1631-6.
-
(2012)
Am J Cardiol.
, vol.110
, pp. 1631-1636
-
-
Cohen, J.D.1
Costa, H.S.2
Russo, R.J.3
-
28
-
-
84861703557
-
Safety of magnetic resonance imaging in patients with permanent pacemakers: A collaborative clinical approach
-
Boilson BA, Wokhlu A, Acker NG, et al. Safety of magnetic resonance imaging in patients with permanent pacemakers: a collaborative clinical approach. J Interv Card Electrophysiol. 2012;33:59-67.
-
(2012)
J Interv Card Electrophysiol.
, vol.33
, pp. 59-67
-
-
Boilson, B.A.1
Wokhlu, A.2
Acker, N.G.3
-
29
-
-
18044384574
-
Implantable cardiac defibrillator interactions with magnetic resonance imaging at 1.5 tesla
-
Coman JA, Martin ET, Sandler DA, et al. Implantable cardiac defibrillator interactions with magnetic resonance imaging at 1.5 tesla. J Am Coll Cardiol. 2004;43:138A.
-
(2004)
J Am Coll Cardiol.
, vol.43
-
-
Coman, J.A.1
Martin, E.T.2
Sandler, D.A.3
-
30
-
-
18044380733
-
Outcome of magnetic resonance imaging (MRI) in selected patients with implantable cardioverter defibrillators (ICDs)
-
Gimbel JR, Kanal E, Schwartz KM, et al. Outcome of magnetic resonance imaging (MRI) in selected patients with implantable cardioverter defibrillators (ICDs). Pacing Clin Electrophysiol. 2005;28:270-3.
-
(2005)
Pacing Clin Electrophysiol.
, vol.28
, pp. 270-273
-
-
Gimbel, J.R.1
Kanal, E.2
Schwartz, K.M.3
-
31
-
-
0011069199
-
Pacemaker safety during magnetic resonance imaging at 1.5 Tesla
-
Coman JA, Martin ET, Ramza BM, et al. Pacemaker safety during magnetic resonance imaging at 1.5 Tesla. J Am Coll Cardiol. 2001;37(Suppl A):436.
-
(2001)
J Am Coll Cardiol.
, vol.37
, Issue.SUPPL. A
, pp. 436
-
-
Coman, J.A.1
Martin, E.T.2
Ramza, B.M.3
|