메뉴 건너뛰기




Volumn 24, Issue 9, 2013, Pages 1059-1065

Not all pacemakers are created equal: MRI conditional pacemaker and lead technology

Author keywords

implantable cardiac device; implantable cardioverter defibrillator; magnetic resonance imaging (MRI); pacemaker

Indexed keywords

ALGORITHM; DIAGNOSTIC VALUE; ELECTROMAGNETIC FIELD; HEART RHYTHM; HEART STIMULATION; HEART VENTRICLE FIBRILLATION; HOME MONITORING; HUMAN; IMPLANTABLE PULSE GENERATOR; IMPLANTED HEART PACEMAKER; IONIZING RADIATION; MAGNETIC FIELD; MORBIDITY; NUCLEAR MAGNETIC RESONANCE IMAGING; OXYGEN SATURATION; PATIENT MONITORING; PATIENT SAFETY; PHANTOM; PRIORITY JOURNAL; PULSE OXIMETRY; RADIOFREQUENCY; REVIEW; WHOLE BODY SCINTISCANNING;

EID: 84883820202     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/jce.12238     Document Type: Review
Times cited : (34)

References (22)
  • 2
    • 77954749308 scopus 로고    scopus 로고
    • Evidence-based guideline: The role of diffusion and perfusion MRI for the diagnosis of acute ischemic stroke: Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology
    • Schellinger PD, Bryan RN, Caplan LR, Detre JA, Edelman RR, Jaigobin C, Kidwell CS, Mohr JP, Sloan M, Sorensen AG, Warach S,: Evidence-based guideline: The role of diffusion and perfusion MRI for the diagnosis of acute ischemic stroke: Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology. Neurol U S 2010; 177-185.
    • (2010) Neurol U S , pp. 177-185
    • Schellinger, P.D.1    Bryan, R.N.2    Caplan, L.R.3    Detre, J.A.4    Edelman, R.R.5    Jaigobin, C.6    Kidwell, C.S.7    Mohr, J.P.8    Sloan, M.9    Sorensen, A.G.10    Warach, S.11
  • 3
    • 84928097222 scopus 로고    scopus 로고
    • A report of the American College of Cardiology foundation quality strategic directions committee appropriateness criteria working group
    • ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging:
    • ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: A report of the American College of Cardiology foundation quality strategic directions committee appropriateness criteria working group. J Am Coll Radiol U S 2006; 751-771.
    • (2006) J Am Coll Radiol U S , pp. 751-771
  • 4
    • 18044393463 scopus 로고    scopus 로고
    • Current clinical issues for MRI scanning of pacemaker and defibrillator patients
    • Kalin R, Stanton MS,: Current clinical issues for MRI scanning of pacemaker and defibrillator patients. PACE 2005; 28: 326-328.
    • (2005) PACE , vol.28 , pp. 326-328
    • Kalin, R.1    Stanton, M.S.2
  • 7
    • 84869089727 scopus 로고    scopus 로고
    • Determining the risks of magnetic resonance imaging at 1.5 Tesla for patients with pacemakers and implantable cardioverter defibrillators
    • Cohen JD, Costa HS, Russo RJ,: Determining the risks of magnetic resonance imaging at 1.5 Tesla for patients with pacemakers and implantable cardioverter defibrillators. Am J Cardiol 2012; 110: 1631-1636.
    • (2012) Am J Cardiol , vol.110 , pp. 1631-1636
    • Cohen, J.D.1    Costa, H.S.2    Russo, R.J.3
  • 8
    • 84883825335 scopus 로고    scopus 로고
    • MagnaSafe (2010):. Retrieved January 14, from
    • MagnaSafe (2010): The MagnaSafe registry. Retrieved January 14, 2013, from http://www.magnasafe.org.
    • (2013) The MagnaSafe Registry
  • 10
    • 70349442539 scopus 로고    scopus 로고
    • Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a 'modern' pacemaker
    • Gimbel JR,: Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a 'modern' pacemaker. Europace 2009; 11: 1241-1242.
    • (2009) Europace , vol.11 , pp. 1241-1242
    • Gimbel, J.R.1
  • 11
    • 79251579035 scopus 로고    scopus 로고
    • MRI of patients with cardiac pacemakers: A review of the medical literature
    • Zikria JF, Machnicki S, Rhim E, Bhatti T, Graham RE,: MRI of patients with cardiac pacemakers: A review of the medical literature. Am J Roentgenol 2011; 196: 390-401.
    • (2011) Am J Roentgenol , vol.196 , pp. 390-401
    • Zikria, J.F.1    Machnicki, S.2    Rhim, E.3    Bhatti, T.4    Graham, R.E.5
  • 12
    • 20344404247 scopus 로고    scopus 로고
    • Unexpected sudden death of pacemaker patients during or shortly after magnetic resonance imaging [MRI]
    • Milan, Italy, 3-6 September. 174, Abstract no. 114
    • Bartsch C, Irnich W, Risse M, Weiler G,: Unexpected sudden death of pacemaker patients during or shortly after magnetic resonance imaging [MRI]. In: XIX Congress of International Academy of Legal Medicine. Milan, Italy, 3-6 September 2003. 174, Abstract no. 114.
    • (2003) XIX Congress of International Academy of Legal Medicine
    • Bartsch, C.1    Irnich, W.2    Risse, M.3    Weiler, G.4
  • 13
    • 25844474128 scopus 로고    scopus 로고
    • Safe, sensible, sagacious: Responsible scanning of pacemaker patients
    • Gimbel JR, Wilkoff BL, Kanal E, Rozner MA,: Safe, sensible, sagacious: Responsible scanning of pacemaker patients. Euro Heart J 2005; 26: 1683-1684.
    • (2005) Euro Heart J , vol.26 , pp. 1683-1684
    • Gimbel, J.R.1    Wilkoff, B.L.2    Kanal, E.3    Rozner, M.A.4
  • 16
    • 0036800991 scopus 로고    scopus 로고
    • Pacemaker Reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: Are Reed switches always closed in strong magnetic fields?
    • Luechinger R, Duru F, Zeijlemaker VA, Scheidegger MB, Boesiger P, Candinas R,: Pacemaker Reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: Are Reed switches always closed in strong magnetic fields? Pacing Clin Electrophysiol 2002; 25: 1419-1423.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1419-1423
    • Luechinger, R.1    Duru, F.2    Zeijlemaker, V.A.3    Scheidegger, M.B.4    Boesiger, P.5    Candinas, R.6
  • 20
    • 84883824060 scopus 로고    scopus 로고
    • Retrieved January 14, from
    • Shellock FG,: Retrieved January 14, 2013, from http://mrisafety.com/ safety-info.asp.
    • (2013)
    • Shellock, F.G.1
  • 21
    • 84883763543 scopus 로고    scopus 로고
    • Boston Scientific Corporation (Published)
    • Boston Scientific Corporation. 2012: Fineline II Sterox EZ pacing lead (Published 2012).
    • (2012) Fineline II Sterox EZ Pacing Lead
  • 22
    • 84866558851 scopus 로고    scopus 로고
    • Monocenter feasibility study of the MRI compatibility of the Evia pacemaker in combination with Safio S pacemaker lead
    • Wollmann C, Steiner E, Vock P, Ndikung B, Mayr H,: Monocenter feasibility study of the MRI compatibility of the Evia pacemaker in combination with Safio S pacemaker lead. J Cardiovasc Magnetic Reson 2012; 14: 67.
    • (2012) J Cardiovasc Magnetic Reson , vol.14 , pp. 67
    • Wollmann, C.1    Steiner, E.2    Vock, P.3    Ndikung, B.4    Mayr, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.