Safe scanning, but frequent artifacts mimicking bradycardia and tachycardia during Magnetic Resonance Imaging (MRI) in patients with an Implantable Loop Recorder (ILR)

Author keywords

Artifact; Loop recorder; MRI; Pacemaker

Indexed keywords

ARTICLE; ARTIFACT; ARTIFICIAL HEART PACEMAKER; ASYSTOLE; BRADYCARDIA; BRAIN TUMOR; CLINICAL ARTICLE; DIAGNOSTIC IMAGING; ELECTROMAGNETIC FIELD; HEAD INJURY; HEART ARRHYTHMIA; HUMAN; IMPLANTATION; KNEE; KNEE PAIN; LEG PAIN; LUMBAR SPINE; MULTIPLE SCLEROSIS; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RECORDER; SHOULDER INJURY; SKULL; TACHYCARDIA; BURN; CLINICAL TRIAL; COMORBIDITY; DIAGNOSTIC ERROR; ELECTROCARDIOGRAPHY; EPIDEMIOLOGY; EQUIPMENT; PREVALENCE; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; STATISTICS; UNITED STATES;

EID: 33644809598     PISSN: 1082720X     EISSN: 1542474X     Source Type: Journal    
DOI: 10.1111/j.1542-474X.2005.00056.x     Document Type: Article
Times cited : (41)

References (17)
  • 1
    • 2442532587 scopus 로고    scopus 로고
    • Insertable loop recorder use for detection of intermittent arrhythmias. (Review)
    • Krahn AD Klein GJ Skanes AC, et al. Insertable loop recorder use for detection of intermittent arrhythmias. (Review) Pacing Clin Electrophysiol 2004 27 ( 5 657 664.
    • (2004) Pacing Clin Electrophysiol , vol.27 , Issue.5 , pp. 657-664
    • Krahn, A.D.1    Klein, G.J.2    Skanes, A.C.3
  • 2
    • 3042607964 scopus 로고    scopus 로고
    • Role of MRI in clinical cardiology. (Review)
    • Constantine G Shan K Flamm SD, et al. Role of MRI in clinical cardiology. (Review) Lancet 2004 363 ( 9427 2162 2171.
    • (2004) Lancet , vol.363 , Issue.9427 , pp. 2162-2171
    • Constantine, G.1    Shan, K.2    Flamm, S.D.3
  • 3
    • 0038221323 scopus 로고    scopus 로고
    • Cardiac pacemakers, ICDs, and loop recorder: Evaluation of translational attraction using conventional ("long-bore") and "short-bore" 1.5- and 3.0-Tesla MR systems
    • Shellock FG Tkach JA Ruggieri PM, et al. Cardiac pacemakers, ICDs, and loop recorder: Evaluation of translational attraction using conventional ("long-bore") and "short-bore" 1.5- and 3.0-Tesla MR systems. J Cardiovasc Magn Reson 2003 5 ( 2 387 397.
    • (2003) J Cardiovasc Magn Reson , vol.5 , Issue.2 , pp. 387-397
    • Shellock, F.G.1    Tkach, J.A.2    Ruggieri, P.M.3
  • 4
    • 0033791857 scopus 로고    scopus 로고
    • Electromagnetic interference of an implantable loop recorder by commonly encountered electronic devices
    • de Cock CC Spruijt HJ van Campen LM, et al. Electromagnetic interference of an implantable loop recorder by commonly encountered electronic devices. Pacing Clin Electrophysiol 2000 23 ( 10 Pt 1 1516 1518.
    • (2000) Pacing Clin Electrophysiol , vol.23 , Issue.101 , pp. 1516-1518
    • De Cock, C.C.1    Spruijt, H.J.2    Van Campen, L.M.3
  • 5
    • 17144433057 scopus 로고    scopus 로고
    • Artefact mimicking tachycardia during magnetic resonance imaging in a patient with an implantable loop recorder
    • Gimbel JR Wilkoff B. Artefact mimicking tachycardia during magnetic resonance imaging in a patient with an implantable loop recorder. Heart 2003 89 ( 3 e10.
    • (2003) Heart , vol.89 , Issue.3
    • Gimbel, J.R.1    Wilkoff, B.2
  • 6
    • 4544229047 scopus 로고    scopus 로고
    • Reveal Plus 9526. Minneapolis, MN, Medtronic, Inc.
    • Reveal Plus 9526. Product Information Manual. Minneapolis, MN, Medtronic, Inc., 2001.
    • (2001) Product Information Manual.
  • 7
    • 0036800992 scopus 로고    scopus 로고
    • Interference in implanted cardiac devices, Part II
    • Pinski SL Trohman RG. Interference in implanted cardiac devices, Part II. Pacing Clin Electrophysiol 2002 25 : 1496 1509.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1496-1509
    • Pinski, S.L.1    Trohman, R.G.2
  • 8
    • 11144354213 scopus 로고    scopus 로고
    • Orthotripsy mimicking asystole
    • Vlay SC. Orthotripsy mimicking asystole. Pacing Clin Electrophysiol 2004 27 ( 4 563.
    • (2004) Pacing Clin Electrophysiol , vol.27 , Issue.4 , pp. 563
    • Vlay, S.C.1
  • 9
    • 0035030110 scopus 로고    scopus 로고
    • Incidence of electromagnetic interference in implantable cardioverter defibrillators
    • Kolb C Zrenner B Schmitt C. Incidence of electromagnetic interference in implantable cardioverter defibrillators. Pacing Clin Electrophysiol 2001 24 ( 4 Pt 1 465 468.
    • (2001) Pacing Clin Electrophysiol , vol.24 , Issue.41 , pp. 465-468
    • Kolb, C.1    Zrenner, B.2    Schmitt, C.3
  • 10
    • 0036742211 scopus 로고    scopus 로고
    • Implantable cardioverter defibrillator dysfunction during and after magnetic resonance imaging
    • Anfinsen OG Berntsen RF Aass H, et al. Implantable cardioverter defibrillator dysfunction during and after magnetic resonance imaging. Pacing Clin Electrophysiol 2002 25 ( 9 1400 1402.
    • (2002) Pacing Clin Electrophysiol , vol.25 , Issue.9 , pp. 1400-1402
    • Anfinsen, O.G.1    Berntsen, R.F.2    Aass, H.3
  • 11
    • 2442716388 scopus 로고    scopus 로고
    • Safety considerations for magnetic resonance imaging of pacemaker and ICD patients
    • Luechinger R Duru F Candinas R, et al. Safety considerations for magnetic resonance imaging of pacemaker and ICD patients. Herzschrittmachertherapie Elektrophysiologie 2004 15 ( 1 73 81.
    • (2004) Herzschrittmachertherapie Elektrophysiologie , vol.15 , Issue.1 , pp. 73-81
    • Luechinger, R.1    Duru, F.2    Candinas, R.3
  • 12
    • 3543053498 scopus 로고    scopus 로고
    • Strategies for the safe performance of magnetic resonance imaging in selected ICD patients. (Abstract)
    • Gimbel JR Trohman RL Lindsay WC, et al. Strategies for the safe performance of magnetic resonance imaging in selected ICD patients. (Abstract) Pacing Clin Electrophysiol 2002 24 : 618.
    • (2002) Pacing Clin Electrophysiol , vol.24 , pp. 618
    • Gimbel, J.R.1    Trohman, R.L.2    Lindsay, W.C.3
  • 13
    • 3242768382 scopus 로고    scopus 로고
    • Complete loss of ICD programmability after magnetic resonance imaging
    • Fiek M Remp T Reithmann C, et al. Complete loss of ICD programmability after magnetic resonance imaging. Pacing Clin Electrophysiol 2004 27 ( 7 1002 1004.
    • (2004) Pacing Clin Electrophysiol , vol.27 , Issue.7 , pp. 1002-1004
    • Fiek, M.1    Remp, T.2    Reithmann, C.3
  • 15
    • 0036556502 scopus 로고    scopus 로고
    • Implantable loop recorder undersensing mimicking complete heart block
    • Chrysostomakis SI Simantirakis EN Marketou ME, et al. Implantable loop recorder undersensing mimicking complete heart block. Europace 2002 4 ( 2 211 213.
    • (2002) Europace , vol.4 , Issue.2 , pp. 211-213
    • Chrysostomakis, S.I.1    Simantirakis, E.N.2    Marketou, M.E.3
  • 16
    • 0037378640 scopus 로고    scopus 로고
    • Sensing issues related to the clinical use of implantable loop recorders
    • Chrysostomakis SI Klapsinos NC Simantirakis EN, et al. Sensing issues related to the clinical use of implantable loop recorders. Europace 2003 5 ( 2 143 148.
    • (2003) Europace , vol.5 , Issue.2 , pp. 143-148
    • Chrysostomakis, S.I.1    Klapsinos, N.C.2    Simantirakis, E.N.3
  • 17
    • 0035313553 scopus 로고    scopus 로고
    • Physician interpretation of electrocardiographic artifact that mimics ventricular tachycardia
    • Knight BP Pelosi F Michaud GF, et al. Physician interpretation of electrocardiographic artifact that mimics ventricular tachycardia. Am J Med 2001 110 ( 5 335 338.
    • (2001) Am J Med , vol.110 , Issue.5 , pp. 335-338
    • Knight, B.P.1    Pelosi, F.2    Michaud, G.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.