메뉴 건너뛰기




Volumn 174, Issue 1, 2014, Pages 1-6

Visualizing anatomical evidences on atrioventricular conduction system for TAVI

Author keywords

Aortic stenosis; Atrioventricular conduction system; Clinical anatomy; New conduction abnormalities; Transcatheter aortic valve implantation

Indexed keywords

ANATOMIC LANDMARK; ANATOMICAL VARIATION; AORTA VALVE PROSTHESIS; ATRIOVENTRICULAR BLOCK; ATRIOVENTRICULAR CONDUCTION; CARDIOVASCULAR RISK; CORONARY ARTERY OBSTRUCTION; DEVICE SAFETY; EQUIPMENT DESIGN; HEART LEFT BUNDLE BRANCH BLOCK; HIGH RISK PATIENT; HUMAN; OUTCOME ASSESSMENT; PRIORITY JOURNAL; REVIEW; SURGICAL RISK; TRANSCATHETER AORTIC VALVE IMPLANTATION; ANATOMY AND HISTOLOGY; HEART MUSCLE CONDUCTION SYSTEM; HEART VALVE REPLACEMENT; PROCEDURES; RISK FACTOR;

EID: 84901240398     PISSN: 01675273     EISSN: 18741754     Source Type: Journal    
DOI: 10.1016/j.ijcard.2014.04.003     Document Type: Review
Times cited : (121)

References (44)
  • 1
    • 77955182912 scopus 로고    scopus 로고
    • Electrocardiographic and future predictors for permanent pacemaker requirement after transcatheter aortic valve implantation
    • D. Erkapic, W.K. Kim, and M. Weber et al. Electrocardiographic and future predictors for permanent pacemaker requirement after transcatheter aortic valve implantation Europace 12 2010 1188 1190
    • (2010) Europace , vol.12 , pp. 1188-1190
    • Erkapic, D.1    Kim, W.K.2    Weber, M.3
  • 2
    • 79951581461 scopus 로고    scopus 로고
    • Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve implantation
    • C. Fraccaro, G. Buja, and G. Tarantini et al. Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve implantation Am J Cardiol 107 2011 747 754
    • (2011) Am J Cardiol , vol.107 , pp. 747-754
    • Fraccaro, C.1    Buja, G.2    Tarantini, G.3
  • 3
    • 80955163682 scopus 로고    scopus 로고
    • Predictors and course of high-degree atrioventricular block after transcatheter aortic valve implantation using the CoreValve revalving system
    • V. Guetta, G. Goldenberg, and A. Segev et al. Predictors and course of high-degree atrioventricular block after transcatheter aortic valve implantation using the CoreValve revalving system Am J Cardiol 108 2011 1600 1605
    • (2011) Am J Cardiol , vol.108 , pp. 1600-1605
    • Guetta, V.1    Goldenberg, G.2    Segev, A.3
  • 4
    • 80855133529 scopus 로고    scopus 로고
    • Clinical outcomes of patients with severe aortic stenosis at increased surgical risk according to treatment modality
    • P. Wenaweser, T. Pilgrim, and A. Kadner et al. Clinical outcomes of patients with severe aortic stenosis at increased surgical risk according to treatment modality J Am Coll Cardiol 58 2011 2151 2162
    • (2011) J Am Coll Cardiol , vol.58 , pp. 2151-2162
    • Wenaweser, P.1    Pilgrim, T.2    Kadner, A.3
  • 5
    • 78651506594 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: First results from a multi-centre real-world registry
    • R. Zahn, U. Gerckens, and E. Grube et al. Transcatheter aortic valve implantation: first results from a multi-centre real-world registry Eur Heart J 32 2011 198 204
    • (2011) Eur Heart J , vol.32 , pp. 198-204
    • Zahn, R.1    Gerckens, U.2    Grube, E.3
  • 6
    • 84861568485 scopus 로고    scopus 로고
    • Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings
    • R. Bagur, J. Rodés-Cabau, and R. Gurvitch et al. Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings J Am Coll Cardiol Intv 5 2012 540 551
    • (2012) J Am Coll Cardiol Intv , vol.5 , pp. 540-551
    • Bagur, R.1    Rodés-Cabau, J.2    Gurvitch, R.3
  • 7
    • 84860479483 scopus 로고    scopus 로고
    • Comparison of complications and outcomes to one year of transcatheter aortic valve implantation versus surgical aortic valve replacement in patients with severe aortic stenosis
    • C. Tamburino, M. Barbanti, and D. Capodanno et al. Comparison of complications and outcomes to one year of transcatheter aortic valve implantation versus surgical aortic valve replacement in patients with severe aortic stenosis Am J Cardiol 109 2012 1487 1493
    • (2012) Am J Cardiol , vol.109 , pp. 1487-1493
    • Tamburino, C.1    Barbanti, M.2    Capodanno, D.3
  • 8
    • 84864285945 scopus 로고    scopus 로고
    • New conduction abnormalities after TAVI - Frequency and causes
    • R.M. van den Boon, R.J. Nuis, and N.M. Van Mieghem et al. New conduction abnormalities after TAVI - frequency and causes Nat Rev Cardiol 9 2012 454 463
    • (2012) Nat Rev Cardiol , vol.9 , pp. 454-463
    • Van Den Boon, R.M.1    Nuis, R.J.2    Van Mieghem, N.M.3
  • 9
    • 84883274502 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation versus surgical aortic valve replacement for severe aortic stenosis: Results from an intermediate risk propensity-matched population of the Italian OBSERVANT study
    • P. D'Errigo, M. Barbanti, and M. Ranucci et al. Transcatheter aortic valve implantation versus surgical aortic valve replacement for severe aortic stenosis: results from an intermediate risk propensity-matched population of the Italian OBSERVANT study Int J Cardiol 167 2013 1945 1952
    • (2013) Int J Cardiol , vol.167 , pp. 1945-1952
    • D'Errigo, P.1    Barbanti, M.2    Ranucci, M.3
  • 10
    • 44949088496 scopus 로고    scopus 로고
    • Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve
    • N. Piazza, Y. Onuma, and E. Jesserun et al. Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve J Am Coll Cardiol Intv 1 2008 310 316
    • (2008) J Am Coll Cardiol Intv , vol.1 , pp. 310-316
    • Piazza, N.1    Onuma, Y.2    Jesserun, E.3
  • 11
    • 64349084245 scopus 로고    scopus 로고
    • Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis
    • H. Jilaihawi, D. Chin, and M. Vasa-Nicotera et al. Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis Am Heart J 157 2009 860 866
    • (2009) Am Heart J , vol.157 , pp. 860-866
    • Jilaihawi, H.1    Chin, D.2    Vasa-Nicotera, M.3
  • 12
    • 77955617014 scopus 로고    scopus 로고
    • Predictors for new-onset complete Heart Block after transcatheter aortic valve implantation
    • S. Bleiziffer, H. Ruge, and J. Hörer et al. Predictors for new-onset complete Heart Block after transcatheter aortic valve implantation J Am Coll Cardiol Intv 3 2010 524 530
    • (2010) J Am Coll Cardiol Intv , vol.3 , pp. 524-530
    • Bleiziffer, S.1    Ruge, H.2    Hörer, J.3
  • 13
    • 78349255551 scopus 로고    scopus 로고
    • Predictors for permanent pacing after transcatheter aortic valve implantation
    • P. Haworth, M. Behan, and M. Khawaja et al. Predictors for permanent pacing after transcatheter aortic valve implantation Catheter Cardiovasc Interv 76 2010 751 756
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 751-756
    • Haworth, P.1    Behan, M.2    Khawaja, M.3
  • 14
    • 78149452061 scopus 로고    scopus 로고
    • Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation
    • L. Roten, P. Wenaweser, and E. Delacrétaz et al. Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation Am J Cardiol 106 2010 1473 1480
    • (2010) Am J Cardiol , vol.106 , pp. 1473-1480
    • Roten, L.1    Wenaweser, P.2    Delacrétaz, E.3
  • 15
    • 78651469380 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Early results of the FRANCE (French aortic national CoreValve and Edwards) registry
    • H. Eltchaninoff, A. Prat, and M. Gilard et al. Transcatheter aortic valve implantation: early results of the FRANCE (French aortic national CoreValve and Edwards) registry Eur Heart J 32 2011 191 197
    • (2011) Eur Heart J , vol.32 , pp. 191-197
    • Eltchaninoff, H.1    Prat, A.2    Gilard, M.3
  • 16
    • 79251565276 scopus 로고    scopus 로고
    • Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis
    • C. Tamburino, D. Capodanno, and A. Ramondo et al. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis Circulation 123 2011 299 308
    • (2011) Circulation , vol.123 , pp. 299-308
    • Tamburino, C.1    Capodanno, D.2    Ramondo, A.3
  • 17
    • 79952738239 scopus 로고    scopus 로고
    • Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: Incidence and contributing factors (the UK CoreValve collaborative)
    • M.Z. Khawaja, R. Rajani, and A. Cook et al. Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: incidence and contributing factors (the UK CoreValve collaborative) Circulation 123 2011 951 960
    • (2011) Circulation , vol.123 , pp. 951-960
    • Khawaja, M.Z.1    Rajani, R.2    Cook, A.3
  • 18
    • 67650514071 scopus 로고    scopus 로고
    • Electrocardiographic changes and clinical outcomes after transapical aortic valve implantation
    • M. Gutiérrez, J. Rodés-Cabau, and R. Bagur et al. Electrocardiographic changes and clinical outcomes after transapical aortic valve implantation Am Heart J 158 2009 302 308
    • (2009) Am Heart J , vol.158 , pp. 302-308
    • Gutiérrez, M.1    Rodés-Cabau, J.2    Bagur, R.3
  • 19
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • M.B. Leon, C.R. Smith, and M. Mack et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery N Engl J Med 363 2010 1597 1607
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3
  • 20
    • 77955927048 scopus 로고    scopus 로고
    • Frequency of conducting disturbances after transcatheter implantation of an Edwards Sapien aortic valve prosthesis
    • M. Godin, H. Eltchaninoff, and A. Furuta et al. Frequency of conducting disturbances after transcatheter implantation of an Edwards Sapien aortic valve prosthesis Am J Cardiol 106 2010 707 712
    • (2010) Am J Cardiol , vol.106 , pp. 707-712
    • Godin, M.1    Eltchaninoff, H.2    Furuta, A.3
  • 21
    • 77649212932 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk. Acute and late outcomes of the multicenter Canadian experience
    • J. Rodés-Cabau, J.G. Webb, and A. Cheung et al. Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk. Acute and late outcomes of the multicenter Canadian experience J Am Coll Cardiol 55 2010 1080 1090
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1080-1090
    • Rodés-Cabau, J.1    Webb, J.G.2    Cheung, A.3
  • 22
    • 77954621513 scopus 로고    scopus 로고
    • Thirty-day Results of the SAPIEN aortic bioprosthesis European outcome (SOURCE) registry. A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve
    • M. Thomas, G. Schymik, and T. Walther et al. Thirty-day Results of the SAPIEN aortic bioprosthesis European outcome (SOURCE) registry. A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve Circulation 122 2010 62 69
    • (2010) Circulation , vol.122 , pp. 62-69
    • Thomas, M.1    Schymik, G.2    Walther, T.3
  • 23
    • 78651520483 scopus 로고    scopus 로고
    • One tear follow-up of the multi-centre European PARTNER transcatheter heart valve study
    • T. Lefévre, A.P. Kappetein, and E. Wolner et al. One tear follow-up of the multi-centre European PARTNER transcatheter heart valve study Eur Heart J 32 2011 148 157
    • (2011) Eur Heart J , vol.32 , pp. 148-157
    • Lefévre, T.1    Kappetein, A.P.2    Wolner, E.3
  • 25
    • 64749110218 scopus 로고    scopus 로고
    • Molecular architecture of the human sinus node: Insights into the function of the cardiac pacemaker
    • N.J. Chandler, I.D. Greener, and J.O. Tellez et al. Molecular architecture of the human sinus node: insights into the function of the cardiac pacemaker Circulation 119 2009 1562 1575
    • (2009) Circulation , vol.119 , pp. 1562-1575
    • Chandler, N.J.1    Greener, I.D.2    Tellez, J.O.3
  • 26
    • 79956259353 scopus 로고    scopus 로고
    • Computer three-dimensional anatomical reconstruction of the human sinus node and a novel paranodal area
    • N. Chandler, O. Aslanidi, and D. Buckley et al. Computer three-dimensional anatomical reconstruction of the human sinus node and a novel paranodal area Anat Rec 294 2011 970 979
    • (2011) Anat Rec , vol.294 , pp. 970-979
    • Chandler, N.1    Aslanidi, O.2    Buckley, D.3
  • 27
    • 84882990262 scopus 로고    scopus 로고
    • The anatomy of the conduction system: Implications for the clinical cardiologist
    • R.H. Anderson, M.R. Boyyett, H. Dobzynski, and F.M. Moorman The anatomy of the conduction system: implications for the clinical cardiologist J Cardiovasc Trans Res 6 2013 187 196
    • (2013) J Cardiovasc Trans Res , vol.6 , pp. 187-196
    • Anderson, R.H.1    Boyyett, M.R.2    Dobzynski, H.3    Moorman, F.M.4
  • 28
    • 77649145354 scopus 로고    scopus 로고
    • Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis
    • J. Baan Jr., Z.Y. Yong, and K.T. Koch et al. Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis Am Heart J 159 2010 497 503
    • (2010) Am Heart J , vol.159 , pp. 497-503
    • Baan, Jr.J.1    Yong, Z.Y.2    Koch, K.T.3
  • 29
    • 80052018699 scopus 로고    scopus 로고
    • Timing and potential mechanisms of new conduction abnormalities during implantation of the Medtronic CoreValve system in patients with aortic stenosis
    • R.J. Nuis, N.M. Van Mieghem, and C.J. Schultz et al. Timing and potential mechanisms of new conduction abnormalities during implantation of the Medtronic CoreValve system in patients with aortic stenosis Eur Heart J 32 2011 2067 2074
    • (2011) Eur Heart J , vol.32 , pp. 2067-2074
    • Nuis, R.J.1    Van Mieghem, N.M.2    Schultz, C.J.3
  • 30
    • 83655184726 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Current and future approaches
    • J. Rodés-Cabau Transcatheter aortic valve implantation: current and future approaches Nat Rev Cardiol 9 2012 15 29
    • (2012) Nat Rev Cardiol , vol.9 , pp. 15-29
    • Rodés-Cabau, J.1
  • 31
    • 44949107393 scopus 로고    scopus 로고
    • Atrioventricular block after transcatheter balloon expandable aortic valve implantation
    • A. Sinhal, L. Altwegg, and S. Pasupati et al. Atrioventricular block after transcatheter balloon expandable aortic valve implantation J Am Coll Cardiol Intv 1 2008 305 309
    • (2008) J Am Coll Cardiol Intv , vol.1 , pp. 305-309
    • Sinhal, A.1    Altwegg, L.2    Pasupati, S.3
  • 32
    • 84865653883 scopus 로고    scopus 로고
    • Incidence and predictors of left bundle branch block after transcatheter aortic valve implantation
    • Ö. Aktug, G. Dohmen, and K. Brehmer et al. Incidence and predictors of left bundle branch block after transcatheter aortic valve implantation Int J Cardiol 160 2012 26 30
    • (2012) Int J Cardiol , vol.160 , pp. 26-30
    • Aktug, Ö.1    Dohmen, G.2    Brehmer, K.3
  • 33
    • 84973460191 scopus 로고    scopus 로고
    • Implantation of the SAPIEN aortic valve: Technical aspects
    • J.D. Carroll, J.G. Webb, Lippincott William & Wilkins Baltinore
    • S. Toggweiler, and J.G. Webb Implantation of the SAPIEN aortic valve: technical aspects J.D. Carroll, J.G. Webb, Structural heart disease interventions 2012 Lippincott William & Wilkins Baltinore 255 266
    • (2012) Structural Heart Disease Interventions , pp. 255-266
    • Toggweiler, S.1    Webb, J.G.2
  • 34
    • 84901208315 scopus 로고    scopus 로고
    • Implantation of the CoreValve aortic valve
    • J.D. Carroll, J.G. Webb, Lippincott William & Wilkins Baltimore
    • J.-C. Laborde, and S.J.D. Brecker Implantation of the CoreValve aortic valve J.D. Carroll, J.G. Webb, Structural heart disease interventions 2012 Lippincott William & Wilkins Baltimore 267 285
    • (2012) Structural Heart Disease Interventions , pp. 267-285
    • Laborde, J.-C.1    Brecker, S.J.D.2
  • 35
    • 84901240230 scopus 로고
    • Aortic valve procedures
    • D.A. Cooley, 2nd ed. W.B. Saunders Co Philadelphia
    • D.A. Cooley Aortic valve procedures D.A. Cooley, Techniques in cardiac surgery 2nd ed. 1984 W.B. Saunders Co Philadelphia 177 200
    • (1984) Techniques in Cardiac Surgery , pp. 177-200
    • Cooley, D.A.1
  • 36
    • 84883753223 scopus 로고    scopus 로고
    • Future perspectives in transcatheter aortic valve implantation
    • C.V. Bourantas, N.M. van Mieghem, and V. Farooq et al. Future perspectives in transcatheter aortic valve implantation Int J Cardiol 168 2013 11 18
    • (2013) Int J Cardiol , vol.168 , pp. 11-18
    • Bourantas, C.V.1    Van Mieghem, N.M.2    Farooq, V.3
  • 37
    • 79960921321 scopus 로고    scopus 로고
    • A new self-expanding transcatheter aortic valve for transapical implantation - First in man implantation of the JenaValve
    • J. Kempfert, A. Raston, F.W. Mohr, and T. Walther A new self-expanding transcatheter aortic valve for transapical implantation - first in man implantation of the JenaValve Eur J Cardio-Thorac Surg 40 2011 761 763
    • (2011) Eur J Cardio-Thorac Surg , vol.40 , pp. 761-763
    • Kempfert, J.1    Raston, A.2    Mohr, F.W.3    Walther, T.4
  • 38
    • 43649086862 scopus 로고    scopus 로고
    • Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement
    • L.F. Tops, D.A. Wood, and V. Delgado et al. Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement J Am Coll Cardiol Img 1 2008 321 330
    • (2008) J Am Coll Cardiol Img , vol.1 , pp. 321-330
    • Tops, L.F.1    Wood, D.A.2    Delgado, V.3
  • 39
    • 84973466947 scopus 로고    scopus 로고
    • Dynamic imaging for structural heart disease interventions
    • J.D. Carroll Dynamic imaging for structural heart disease interventions Card Interv Today 2 2008 65 68
    • (2008) Card Interv Today , vol.2 , pp. 65-68
    • Carroll, J.D.1
  • 40
    • 34249788156 scopus 로고    scopus 로고
    • Image guidance of percutaneous coronary and structural heart disease interventions using a computed tomography and fluoroscopic integration
    • J. Garcia, M.H. Eng, and S.Y. Chen et al. Image guidance of percutaneous coronary and structural heart disease interventions using a computed tomography and fluoroscopic integration Vasc Dis Manag 4 2007 87 89
    • (2007) Vasc Dis Manag , vol.4 , pp. 87-89
    • Garcia, J.1    Eng, M.H.2    Chen, S.Y.3
  • 41
    • 63149128743 scopus 로고    scopus 로고
    • On-line multi-slice computed tomography interactive overlay with conventional X-ray: A new and advanced imaging fusion concept
    • J. Garcia, S. Bhakta, and J. Kay et al. On-line multi-slice computed tomography interactive overlay with conventional X-ray: a new and advanced imaging fusion concept Int J Cardiol 133 2009 e101 e105
    • (2009) Int J Cardiol , vol.133
    • Garcia, J.1    Bhakta, S.2    Kay, J.3
  • 42
    • 67649628417 scopus 로고    scopus 로고
    • Coronary computed tomographic angiography in the cardiac catheterization laboratory: Current applications and future developments
    • O. Wink, H. Hecht, and D. Ruiters Coronary computed tomographic angiography in the cardiac catheterization laboratory: current applications and future developments Cardiol Clin 27 2009 513 529
    • (2009) Cardiol Clin , vol.27 , pp. 513-529
    • Wink, O.1    Hecht, H.2    Ruiters, D.3
  • 43
    • 84901245470 scopus 로고    scopus 로고
    • Transapical aortic valve implantation with anatomically oriented prostheses
    • S. Sündermann, and V. Falk Transapical aortic valve implantation with anatomically oriented prostheses Ann Cardiothorac Surg 1 2012 176 181
    • (2012) Ann Cardiothorac Surg , vol.1 , pp. 176-181
    • Sündermann, S.1    Falk, V.2
  • 44
    • 84865348112 scopus 로고    scopus 로고
    • Transapical transcatheter aortic valve implantation using the JenaValve™ system: Acute and 30-day results of the multicentre CE-mark study
    • H. Treede, F.W. Mohr, and S. Baldus et al. Transapical transcatheter aortic valve implantation using the JenaValve™ system: acute and 30-day results of the multicentre CE-mark study Eur J Cardio-Thorac Surg 41 2012 e131 e138
    • (2012) Eur J Cardio-Thorac Surg , vol.41
    • Treede, H.1    Mohr, F.W.2    Baldus, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.