메뉴 건너뛰기




Volumn 32, Issue 16, 2011, Pages 2067-2074

Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis

Author keywords

Conduction abnormalities; Pacemaker; Timing; Transcatheter aortic valve implantation

Indexed keywords

AGED; AORTA STENOSIS; AORTA VALVE; ARTICLE; BALLOON CATHETER; CATHETER REMOVAL; COMPLETE HEART BLOCK; DEVICE THERAPY; ELECTROCARDIOGRAPHY; FEMALE; HEART LEFT BUNDLE BRANCH BLOCK; HEART LEFT VENTRICLE OUTFLOW TRACT; HEART RIGHT BUNDLE BRANCH BLOCK; HUMAN; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; SURGICAL RISK; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSLUMINAL VALVULOPLASTY; TREATMENT OUTCOME;

EID: 80052018699     PISSN: 0195668X     EISSN: 15229645     Source Type: Journal    
DOI: 10.1093/eurheartj/ehr110     Document Type: Article
Times cited : (159)

References (32)
  • 1
    • 77649145354 scopus 로고    scopus 로고
    • Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the Core-Valve prosthesis
    • Baan JJ, Yong Z, Koch K, Henriques J, Bouma B, Vis M, Cocchieri R, Piek J, de Mol B. Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the Core-Valve prosthesis. Am Heart J 2010;159:497-503.
    • (2010) Am Heart J , vol.159 , pp. 497-503
    • Baan, J.J.1    Yong, Z.2    Koch, K.3    Henriques, J.4    Bouma, B.5    Vis, M.6    Cocchieri, R.7    Piek, J.8    De Mol, B.9
  • 3
    • 77955182912 scopus 로고    scopus 로고
    • Electrocardiographic and further predictors for permanent pacemaker requirement after transcatheter aortic valve implantation
    • Erkapic D, Kim W, Weber M, Mö llmann H, Berkowitsch A, Zaltsberg S, Pajitnev D, Rixe J, Neumann T, Kuniss M, Sperzel J, Hamm C, Pitschner H. Electrocardiographic and further predictors for permanent pacemaker requirement after transcatheter aortic valve implantation. Europace 2010;12:1188-1190.
    • (2010) Europace , vol.12 , pp. 1188-1190
    • Erkapic D, K.1
  • 4
    • 79952198456 scopus 로고    scopus 로고
    • Persistent conduction abnormalities and requirements for pacemaking six months after transcatheter aortic valve implantation
    • Piazza N, Nuis R, Tzikas A, Otten A, Onuma Y, García-García H, Schultz C, van Domburg R, van Es G, van Geuns R, de Jaegere P, Serruys P. Persistent conduction abnormalities and requirements for pacemaking six months after transcatheter aortic valve implantation. EuroIntervention 2010;6:475-484.
    • (2010) EuroIntervention , vol.6 , pp. 475-484
    • Piazza N, N.1
  • 5
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve revalving system: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • Piazza N, Grube E, Gerckens U, den Heijer P, Linke A, Luha O, Ramondo A, Ussia G, Wenaweser P, Windecker S, Laborde J, de Jaegere P, Serruys P. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention 2008;4:242-249.
    • (2008) EuroIntervention , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3    Den Heijer, P.4    Linke, A.5    Luha, O.6    Ramondo, A.7    Ussia, G.8    Wenaweser, P.9    Windecker, S.10    Laborde, J.11    De Jaegere, P.12    Serruys, P.13
  • 10
    • 64349084245 scopus 로고    scopus 로고
    • Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis
    • Jilaihawi H, Chin D, Vasa-Nicotera M, Jeilan M, Spyt T, Ng G, Bence J, Logtens E, Kovac J. Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis. Am Heart J 2009; 157:860-866.
    • (2009) Am Heart J , vol.157 , pp. 860-866
    • Jilaihawi, H.1    Chin, D.2    Vasa-Nicotera, M.3    Jeilan, M.4    Spyt, T.5    Ng, G.6    Bence, J.7    Logtens, E.8    Kovac, J.9
  • 13
    • 44949088496 scopus 로고    scopus 로고
    • Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve
    • DOI 10.1016/j.jcin.2008.04.007, PII S193687980800188X
    • Piazza N, Onuma Y, Jesserun E, Kint P, Maugenest A, Anderson R, de Jaegere P, Serruys P. Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve. JACC Cardiovasc Interv 2008;1:310-316. (Pubitemid 351804194)
    • (2008) JACC: Cardiovascular Interventions , vol.1 , Issue.3 , pp. 310-316
    • Piazza, N.1    Onuma, Y.2    Jesserun, E.3    Kint, P.P.4    Maugenest, A.-M.5    Anderson, R.H.6    De Jaegere, P.P.T.7    Serruys, P.W.8
  • 16
    • 0021877091 scopus 로고
    • Criteria for intraventricular conduction disturbances and pre-excitation. World Health Organizational/International Society and Federation for Cardiology Task Force Ad Hoc
    • Willems J, Robles de Medina E, Bernard R, Coumel P, Fisch C, Krikler D, Mazur N, Meijler F, Mogensen L, Moret P. Criteria for intraventricular conduction disturbances and pre-excitation. World Health Organizational/ International Society and Federation for Cardiology Task Force Ad Hoc. J Am Coll Cardiol 1985;5: 1261-1275.
    • (1985) J Am Coll Cardiol , vol.5 , pp. 1261-1275
    • Willems, J.1    Robles De Medina, E.2    Bernard, R.3    Coumel, P.4    Fisch, C.5    Krikler, D.6    Mazur, N.7    Meijler, F.8    Mogensen, L.9    Moret, P.10
  • 17
  • 18
    • 62949095752 scopus 로고    scopus 로고
    • Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve
    • Piazza N, de Jaegere P, Schultz C, Becker A, Serruys P, Anderson R. Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv 2008;1:74-81.
    • (2008) Circ Cardiovasc Interv , vol.1 , pp. 74-81
    • Piazza, N.1    De Jaegere, P.2    Schultz, C.3    Becker, A.4    Serruys, P.5    Anderson, R.6
  • 23
    • 0023156744 scopus 로고
    • Assessment of left ventricular and aortic valve function after aortic balloon valvuloplasty in adult patients with critical aortic stenosis
    • McKay R, Safian R, Lock J, Diver D, Berman A, Warren S, Come P, Baim D, Mandell V, Royal H. Assessment of left ventricular and aortic valve function after aortic balloon valvuloplasty in adult patients with critical aortic stenosis. Circulation 1987;75:192-203. (Pubitemid 17234558)
    • (1987) Circulation , vol.75 , Issue.1 , pp. 192-203
    • McKay, R.G.1    Safian, R.D.2    Lock, J.E.3
  • 24
    • 0024427954 scopus 로고
    • Complete heart block developing during aortic valvuloplasty
    • Plack R, Porterfield J, Brinker J. Complete heart block developing during aortic valvuloplasty. Chest 1989;96:1201-1203. (Pubitemid 19266590)
    • (1989) Chest , vol.96 , Issue.5 , pp. 1201-1203
    • Plack, R.H.1    Porterfield, J.K.2    Brinker, J.A.3
  • 26
    • 37349119070 scopus 로고    scopus 로고
    • Permanent pacemaker implantation after isolated aortic valve replacement: Incidence, indications, and predictors
    • DOI 10.1016/j.athoracsur.2007.08.024, PII S0003497507017742
    • Dawkins S, Hobson A, Kalra P, Tang A, Monro J, Dawkins K. Permanent pacemaker implantation after isolated aortic valve replacement: incidence, indications, and predictors. Ann Thorac Surg 2008;85:108-112. (Pubitemid 350284581)
    • (2008) Annals of Thoracic Surgery , vol.85 , Issue.1 , pp. 108-112
    • Dawkins, S.1    Hobson, A.R.2    Kalra, P.R.3    Tang, A.T.M.4    Monro, J.L.5    Dawkins, K.D.6
  • 29
    • 78449245596 scopus 로고    scopus 로고
    • First successful trans-catheter aortic valve implantation through ascending aorta using Edwards SAPIEN THV system
    • Bapat V, Thomas M, Hancock J, Wilson K. First successful trans-catheter aortic valve implantation through ascending aorta using Edwards SAPIEN THV system. Eur J Cardiothorac Surg 2010;38:811-813.
    • (2010) Eur J Cardiothorac Surg , vol.38 , pp. 811-813
    • Bapat, V.1    Thomas, M.2    Hancock, J.3    Wilson, K.4
  • 30
    • 77952781134 scopus 로고    scopus 로고
    • Transaortic transcatheter aortic valve implantation: A novel approach for the truly 'no-access option' patients
    • Latsios G, Gerckens U, Grube E. Transaortic transcatheter aortic valve implantation: a novel approach for the truly 'no-access option' patients. Catheter Cardiovasc Interv 2010;75:1129-1136.
    • (2010) Catheter Cardiovasc Interv , vol.75 , pp. 1129-1136
    • Latsios, G.1    Gerckens, U.2    Grube, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.