메뉴 건너뛰기




Volumn 16, Issue 1, 2014, Pages

Safe performance of magnetic resonance of the heart in patients with magnetic resonance conditional pacemaker systems: The safety issue of the ESTIMATE study

Author keywords

Complications; Heart MR; Magnet resonance; MR conditional; Permanent pacemaker

Indexed keywords

LEAD;

EID: 84901234499     PISSN: 10976647     EISSN: 1532429X     Source Type: Journal    
DOI: 10.1186/1532-429X-16-30     Document Type: Article
Times cited : (47)

References (26)
  • 2
    • 44649139918 scopus 로고    scopus 로고
    • Magnetic resonance imaging in individuals with cardiovascular implantable electronic devices
    • DOI 10.1093/europace/eun021
    • Magnetic resonance imaging in individuals with cardiovascular implantable electronic devices. Roguin A, Schwitter J, Vahlhaus C, Lombardi M, Brugada J, Vardas P, Auricchio A, Priori S, Sommer T, Europace 2008 10 336 46 10.1093/europace/eun021 18308754 (Pubitemid 351773738)
    • (2008) Europace , vol.10 , Issue.3 , pp. 336-346
    • Roguin, A.1    Schwitter, J.2    Vahlhaus, C.3    Lombardi, M.4    Brugada, J.5    Vardas, P.6    Auricchio, A.7    Priori, S.8    Sommer, T.9
  • 3
    • 33748752144 scopus 로고    scopus 로고
    • Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 tesla in the presence of cardiac pacemakers in non-pacemaker-dependent patients: A prospective study with 115 examinations
    • DOI 10.1161/CIRCULATIONAHA.105.597013, PII 0000301720060919000012
    • Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 Tesla in the presence of cardiac pacemakers in non-pacemaker dependent patients. A prospective study with 115 examinations. Sommer T, Naehle CP, Yang A, Zeijlemaker V, Hackenbroch M, Schmiedel A, Meyer C, Strach K, Skowasch D, Vahlhaus C, Litt H, Schild H, Circulation 2006 114 1285 92 10.1161/ CIRCULATIONAHA.105.597013 16966587 (Pubitemid 44402054)
    • (2006) Circulation , vol.114 , Issue.12 , pp. 1285-1292
    • Sommer, T.1    Naehle, C.P.2    Yang, A.3    Zeijlemaker, V.4    Hackenbroch, M.5    Schmiedel, A.6    Meyer, C.7    Strach, K.8    Skowasch, D.9    Vahlhaus, C.10    Litt, H.11    Schild, H.12
  • 6
    • 79958093042 scopus 로고    scopus 로고
    • Safety, feasibility, and diagnostic value of cardiac magnetic resonance imaging in patients with cardiac pacemakers and implantable cardioverters/ defibrillators at 1.5 T
    • 10.1016/j.ahj.2011.03.007 21641356
    • Safety, feasibility, and diagnostic value of cardiac magnetic resonance imaging in patients with cardiac pacemakers and implantable cardioverters/ defibrillators at 1.5 T. Naehle CP, Kreuz J, Strach K, Schwab JO, Pingel S, Luechinger R, Fimmers R, Schild H, Thomas D, Am Heart J 2011 161 1096 105 10.1016/j.ahj.2011.03.007 21641356
    • (2011) Am Heart J , vol.161 , pp. 1096-1105
    • Naehle, C.P.1    Kreuz, J.2    Strach, K.3    Schwab, J.O.4    Pingel, S.5    Luechinger, R.6    Fimmers, R.7    Schild, H.8    Thomas, D.9
  • 8
    • 84875231968 scopus 로고    scopus 로고
    • Determining the risks of clinically indicated nonthoracic magnetic resonance imaging at 1.5 T for patients with pacemakers and implantable cardioverter-defibrillators: Rationale and design of the MagnaSafe Registry
    • 10.1016/j.ahj.2012.12.004 23453091
    • Determining the risks of clinically indicated nonthoracic magnetic resonance imaging at 1.5 T for patients with pacemakers and implantable cardioverter-defibrillators: rationale and design of the MagnaSafe Registry. Russo RJ, Am Heart J 2013 165 266 72 10.1016/j.ahj.2012.12.004 23453091
    • (2013) Am Heart J , vol.165 , pp. 266-272
    • Russo, R.J.1
  • 9
    • 84880937087 scopus 로고    scopus 로고
    • 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: The task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). European Society of Cardiology (ESC); European Heart Rhythm Association (EHRA)
    • 23801827
    • - 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). European Society of Cardiology (ESC); European Heart Rhythm Association (EHRA). Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, Cleland J, Deharo JC, Delgado V, Elliott PM, Gorenek B, Israel CW, Leclercq C, Linde C, Mont L, Padeletti L, Sutton R, Vardas PE, European Society of Cardiology (ESC), Europace 2013 15 1070 118 23801827
    • (2013) Europace , vol.15 , pp. 1070-1118
    • Brignole, M.1    Auricchio, A.2    Baron-Esquivias, G.3    Bordachar, P.4    Boriani, G.5    Breithardt, O.A.6    Cleland, J.7    Deharo, J.C.8    Delgado, V.9    Elliott, P.M.10    Gorenek, B.11    Israel, C.W.12    Leclercq, C.13    Linde, C.14    Mont, L.15    Padeletti, L.16    Sutton, R.17    Vardas, P.E.18
  • 11
    • 33845894695 scopus 로고    scopus 로고
    • Cardiac pacemakers and implantable cardioverter defibrillators: In vitro magnetic resonance imaging evaluation at 1.5-Tesla
    • DOI 10.1080/10976640600897237, PII V83107634342UQT0
    • Cardiac pacemakers and implantable cardioverter defibrillators: in vitro magnetic resonance imaging evaluation at 1.5-Tesla. Shellock FG, Fischer L, Fieno DS, J Cardiovasc Magn Reson 2007 9 21 31 10.1080/10976640600897237 17178677 (Pubitemid 46018480)
    • (2007) Journal of Cardiovascular Magnetic Resonance , vol.9 , Issue.1 , pp. 21-31
    • Shellock, F.G.1    Fischer, L.2    Fieno, D.S.3
  • 12
    • 84900402281 scopus 로고    scopus 로고
    • Medtronic, Inc. 2013 [Internet]. Available from
    • Revo MRI SureScan Pacing System MRI Technical Manual. Medtronic, Inc. 2013 [Internet]. Available from: http://manuals.medtronic.com/manuals/main/us/ en-US/manual
    • Revo MRI SureScan Pacing System MRI Technical Manual
  • 13
    • 84901200379 scopus 로고    scopus 로고
    • Medtronic, Inc. 2011 [Internet]. Technical manual. Available from
    • EnRhythm MRI SureScan Pacing System. Medtronic, Inc. 2011 [Internet]. Technical manual. Available from: http://manuals.medtronic.com/manuals/main/us/ en-US/manual
    • EnRhythm MRI SureScan Pacing System
  • 15
    • 84855575767 scopus 로고    scopus 로고
    • Initial experience with magnetic resonance imaging-safe pacemakers. A review
    • 10.1007/s10840-011-9610-0 21993594
    • Initial experience with magnetic resonance imaging-safe pacemakers. A review. Jung W, Zvereva V, Hajredini B, Jäckle S, J Interv Card Electrophysiol 2011 32 213 9 10.1007/s10840-011-9610-0 21993594
    • (2011) J Interv Card Electrophysiol , vol.32 , pp. 213-219
    • Jung, W.1    Zvereva, V.2    Hajredini, B.3    Jäckle, S.4
  • 16
    • 84856794492 scopus 로고    scopus 로고
    • Magnetic resonance imaging in patients with cardiac pacemakers: Era of MR Conditional designs
    • 10.1186/1532-429X-13-63 22032338
    • Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs. Shinbane JS, Colletti PM, Shellock FG, J Cardiovasc Magn Reson 2011 13 63 10.1186/1532-429X-13-63 22032338
    • (2011) J Cardiovasc Magn Reson , vol.13 , pp. 63
    • Shinbane, J.S.1    Colletti, P.M.2    Shellock, F.G.3
  • 17
    • 43749117056 scopus 로고    scopus 로고
    • American College of Cardiology/American Heart Association Task Force on Practice Guidelines. ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
    • A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing committee to revise the ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices) developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons10.1016/j.jacc.2008.02.032 18498951
    • American College of Cardiology/American Heart Association Task Force on Practice Guidelines. ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing committee to revise the ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices) developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons. Epstein AE, DiMarco JP, Ellenbogen KA, Estes NA 3rd, Freedman RA, Gettes LS, Gillinov AM, Gregoratos G, Hammill SC, Hayes DL, Hlatky MA, Newby LK, Page RL, Schoenfeld MH, Silka MJ, Stevenson LW, Sweeney MO, Smith SC Jr, Jacobs AK, Adams CD, Anderson JL, Buller CE, Creager MA, Ettinger SM, Faxon DP, Halperin JL, Hiratzka LF, Hunt SA, Krumholz HM, Kushner FG, al. et, J Am Coll Cardiol 2008 51 1 62 10.1016/j.jacc.2008.02.032 18498951
    • (2008) J Am Coll Cardiol , vol.51 , pp. 51-62
    • Epstein, A.E.1    Dimarco, J.P.2    Ellenbogen, K.A.3    Estes III, A.N.4    Freedman, R.A.5    Gettes, L.S.6    Gillinov, A.M.7    Gregoratos, G.8    Hammill, S.C.9    Hayes, D.L.10    Hlatky, M.A.11    Newby, L.K.12    Page, R.L.13    Schoenfeld, M.H.14    Silka, M.J.15    Stevenson, L.W.16    Sweeney, M.O.17
  • 19
    • 84901196847 scopus 로고    scopus 로고
    • Medtronic, Inc. 2012 [Internet]. Technical manual. Available from
    • CapSureFix MRI™ SureScan™ 5086MRI. Medtronic, Inc. 2012 [Internet]. Technical manual. Available from: http://manuals.medtronic.com/ manuals/main/us/en-US/manual
    • CapSureFix MRI™ SureScan™ 5086MRI
  • 20
    • 84901200268 scopus 로고    scopus 로고
    • Available from
    • Medtronic News Release 2008 [Internet]. Available from: http://wwwp.medtronic.com/Newsroom/NewsReleaseDetails.do?itemId= 1226935170803&lang=de-DE
    • Medtronic News Release 2008
  • 23
    • 77955001821 scopus 로고    scopus 로고
    • Magnetic resonance imaging of pacemakers and implantable cardioverter defibrillators without specific absorption rate restrictions
    • 10.1093/europace/euq092 20353963
    • Magnetic resonance imaging of pacemakers and implantable cardioverter defibrillators without specific absorption rate restrictions. Mollerus M, Albin G, Lipinski M, Lucca J, Europace 2010 12 947 51 10.1093/europace/euq092 20353963
    • (2010) Europace , vol.12 , pp. 947-951
    • Mollerus, M.1    Albin, G.2    Lipinski, M.3    Lucca, J.4
  • 25
    • 84866558851 scopus 로고    scopus 로고
    • Monocenter feasibility study of the MRI compatibility of the Evia Pacemaker in combination with Safio S Pacemaker Lead
    • 10.1186/1532-429X-14-67 23009683
    • Monocenter feasibility study of the MRI compatibility of the Evia Pacemaker in combination with Safio S Pacemaker Lead. Wollmann CG, Steiner E, Vock P, Mayr H, J Cardiovasc Magn Reson 2012 14 67 10.1186/1532-429X-14-67 23009683
    • (2012) J Cardiovasc Magn Reson , vol.14 , pp. 67
    • Wollmann, C.G.1    Steiner, E.2    Vock, P.3    Mayr, H.4
  • 26
    • 84884890660 scopus 로고    scopus 로고
    • Impact of the Advisa MRI pacing system on the diagnostic quality of cardiac MR images and contraction patterns of cardiac muscle during scans: Advisa MRI randomized clinical multicenter study results
    • Impact of the Advisa MRI pacing system on the diagnostic quality of cardiac MR images and contraction patterns of cardiac muscle during scans: Advisa MRI randomized clinical multicenter study results. Schwitter J, Kanal E, Schmitt M, Anselme F, Albert T, Hayes DL, Bello D, Tóth A, Chang Y, van Osch D, Sommer T, Advisa MRI System Study Investigators, Heart Rhythm 2013 6 864 72
    • (2013) Heart Rhythm , vol.6 , pp. 864-872
    • Schwitter, J.1    Kanal, E.2    Schmitt, M.3    Anselme, F.4    Albert, T.5    Hayes, D.L.6    Bello, D.7    Tóth, A.8    Chang, Y.9    Van Osch, D.10    Sommer, T.11


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.