Evaluation of cumulative effects of MR imaging on pacemaker systems at 1.5 Tesla

Author keywords

1.5T; Cumulative effects; MRI; Pacemaker; Safety

Indexed keywords

CLINICAL EVALUATION; ELECTRIC POTENTIAL; FOLLOW UP; HEART ATRIUM FIBRILLATION; HEART ATRIUM PACING; HEART VENTRICLE PACING; HUMAN; INFORMED CONSENT; NUCLEAR MAGNETIC RESONANCE IMAGING; PACEMAKER; PATIENT SAFETY; POTENTIOMETRY; REPEAT PROCEDURE; REVIEW; RISK ASSESSMENT; SINUS NODE;

EID: 70449724740     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2009.02570.x     Document Type: Review
Times cited : (51)

References (30)
  • 1
    • 0034077462 scopus 로고    scopus 로고
    • MR imaging and cardiac pacemakers: In vitro evaluation and in vivo studies in 51 patients at 0.5 T
    • Sommer T, Vahlhaus C, Lauck G, von Smekal A, Reinke M, Hofer U, Block W, et al. MR imaging and cardiac pacemakers: In vitro evaluation and in vivo studies in 51 patients at 0.5 T. Radiology 2000 215 : 869 879.
    • (2000) Radiology , vol.215 , pp. 869-879
    • Sommer, T.1    Vahlhaus, C.2    Lauck, G.3    Von Smekal, A.4    Reinke, M.5    Hofer, U.6    Block, W.7
  • 2
    • 3543116170 scopus 로고    scopus 로고
    • Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe: In vitro and in vivo assessment of safety and function at 1.5 T
    • Roguin A, Zviman MM, Meininger GR, Rodrigues ER, Dickfeld TM, Bluemke DA, Lardo A, et al. Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe: In vitro and in vivo assessment of safety and function at 1.5 T. Circulation 2004 110 : 475 482.
    • (2004) Circulation , vol.110 , pp. 475-482
    • Roguin, A.1    Zviman, M.M.2    Meininger, G.R.3    Rodrigues, E.R.4    Dickfeld, T.M.5    Bluemke, D.A.6    Lardo, A.7
  • 3
    • 19644388361 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the brain in patients with cardiac pacemakers. Experimental and clinical investigations at 1.5 Tesla
    • Schmiedel A, Hackenbroch M, Yang A, Nahle CP, Skowasch D, Meyer C, Schimpf R, et al. Magnetic resonance imaging of the brain in patients with cardiac pacemakers. Experimental and clinical investigations at 1.5 Tesla. Rofo 2005 177 : 731 744.
    • (2005) Rofo , vol.177 , pp. 731-744
    • Schmiedel, A.1    Hackenbroch, M.2    Yang, A.3    Nahle, C.P.4    Skowasch, D.5    Meyer, C.6    Schimpf, R.7
  • 4
    • 33748740922 scopus 로고    scopus 로고
    • Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 Tesla
    • Nazarian S, Roguin A, Zviman MM, Lardo AC, Dickfeld TL, Calkins H, Weiss RG, et al. Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 Tesla. Circulation 2006 114 : 1277 2784.
    • (2006) Circulation , vol.114 , pp. 1277-2784
    • Nazarian, S.1    Roguin, A.2    Zviman, M.M.3    Lardo, A.C.4    Dickfeld, T.L.5    Calkins, H.6    Weiss, R.G.7
  • 5
    • 33748752144 scopus 로고    scopus 로고
    • Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 Tesla in the presence of cardiac pacemakers in non-pacemaker-dependent patients. A prospective study with 115 examinations
    • Sommer T, Naehle CP, Yang A, Zeijlemaker V, Hackenbroch M, Schmiedel A, Meyer C, et al. Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 Tesla in the presence of cardiac pacemakers in non-pacemaker-dependent patients. A prospective study with 115 examinations. Circulation 2006 114 : 1285 1292.
    • (2006) Circulation , vol.114 , pp. 1285-1292
    • Sommer, T.1    Naehle, C.P.2    Yang, A.3    Zeijlemaker, V.4    Hackenbroch, M.5    Schmiedel, A.6    Meyer, C.7
  • 6
    • 58149193750 scopus 로고    scopus 로고
    • Safety of brain 3-T MR imaging with transmit-receive head coil in patients with cardiac pacemakers: Pilot prospective study with 51 examinations
    • Naehle CP, Meyer C, Thomas D, Remerie S, Krautmacher C, Litt H, Luechinger R, et al. Safety of brain 3-T MR imaging with transmit-receive head coil in patients with cardiac pacemakers: Pilot prospective study with 51 examinations. Radiology 2008 249 : 991 1001.
    • (2008) Radiology , vol.249 , pp. 991-1001
    • Naehle, C.P.1    Meyer, C.2    Thomas, D.3    Remerie, S.4    Krautmacher, C.5    Litt, H.6    Luechinger, R.7
  • 7
    • 37349049968 scopus 로고    scopus 로고
    • Levine GN, Gomes AS, Arai AE, Bluemke DA, Flamm SD, Kanal E, Manning WJ, et al. Safety of magnetic resonance imaging in patients with cardiovascular devices: An American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: Endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance. Circulation 2007 116 : 2878 2891.
    • (2007) Circulation , vol.116 , pp. 2878-2891
    • Levine, G.N.1    Gomes, A.S.2    Arai, A.E.3    Bluemke, D.A.4    Flamm, S.D.5    Kanal, E.6    Manning, W.J.7
  • 9
    • 33748741479 scopus 로고    scopus 로고
    • Food and Drug Administration perspective: Magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients
    • Faris OP, Shein M. Food and Drug Administration perspective: Magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients. Circulation 2006 114 : 1232 1233.
    • (2006) Circulation , vol.114 , pp. 1232-1233
    • Faris, O.P.1    Shein, M.2
  • 10
    • 18044383757 scopus 로고    scopus 로고
    • Government viewpoint: U.S. Food & Drug Administration: Pacemakers, ICDs and MRI
    • Faris OP, Shein MJ. Government viewpoint: U.S. Food & Drug Administration: Pacemakers, ICDs and MRI. Pacing Clin Electrophysiol 2005 28 : 268 269.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 268-269
    • Faris, O.P.1    Shein, M.J.2
  • 13
    • 0043202553 scopus 로고    scopus 로고
    • Threshold measurements: Ten rules for good measuring practice
    • Irnich W. Threshold measurements: Ten rules for good measuring practice. Pacing Clin Electrophysiol 2003 26 : 1738 1746.
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 1738-1746
    • Irnich, W.1
  • 14
    • 0014114820 scopus 로고
    • Changes in myocardial threshold. Physiologic and pharmacologic factors in patients with implanted pacemakers
    • Preston TA, Fletcher RD, Lucchesi BR, Judge RD. Changes in myocardial threshold. Physiologic and pharmacologic factors in patients with implanted pacemakers. Am Heart J 1967 74 : 235 242.
    • (1967) Am Heart J , vol.74 , pp. 235-242
    • Preston, T.A.1    Fletcher, R.D.2    Lucchesi, B.R.3    Judge, R.D.4
  • 18
    • 0032935092 scopus 로고    scopus 로고
    • Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction: Final results of a prospective, multicenter clinical trial. the Atakr Multicenter Investigators Group
    • Calkins H, Yong P, Miller JM, Olshansky B, Carlson M, Saul JP, Huang SK, et al. Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction: Final results of a prospective, multicenter clinical trial. The Atakr Multicenter Investigators Group. Circulation 1999 99 : 262 270.
    • (1999) Circulation , vol.99 , pp. 262-270
    • Calkins, H.1    Yong, P.2    Miller, J.M.3    Olshansky, B.4    Carlson, M.5    Saul, J.P.6    Huang, S.K.7
  • 24
    • 62649135122 scopus 로고    scopus 로고
    • Measuring RF-induced currents inside implants: Impact of device configuration on MRI safety of cardiac pacemaker leads
    • Nordbeck P, Weiss I, Ehses P, Ritter O, Warmuth M, Fidler F, Herold V, et al. Measuring RF-induced currents inside implants: Impact of device configuration on MRI safety of cardiac pacemaker leads. Magn Reson Med 2009 61 : 570 578.
    • (2009) Magn Reson Med , vol.61 , pp. 570-578
    • Nordbeck, P.1    Weiss, I.2    Ehses, P.3    Ritter, O.4    Warmuth, M.5    Fidler, F.6    Herold, V.7
  • 25
    • 0036800991 scopus 로고    scopus 로고
    • Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: Are reed switches always closed in strong magnetic fields?
    • Luechinger R, Duru F, Zeijlemaker VA, Scheidegger MB, Boesiger P, Candinas R. Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: Are reed switches always closed in strong magnetic fields? Pacing Clin Electrophysiol 2002 25 : 1419 1423.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1419-1423
    • Luechinger, R.1    Duru, F.2    Zeijlemaker, V.A.3    Scheidegger, M.B.4    Boesiger, P.5    Candinas, R.6
  • 27
    • 70349442539 scopus 로고    scopus 로고
    • Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a 'modern' pacemaker
    • Gimbel JR. Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a 'modern' pacemaker. Europace 2009 11 : 1241 1242.
    • (2009) Europace , vol.11 , pp. 1241-1242
    • Gimbel, J.R.1
  • 28
    • 39649111737 scopus 로고    scopus 로고
    • Determinants of gradient field-induced current in a pacemaker lead system in a magnetic resonance imaging environment
    • Tandri H, Zviman MM, Wedan SR, Lloyd T, Berger RD, Halperin H. Determinants of gradient field-induced current in a pacemaker lead system in a magnetic resonance imaging environment. Heart Rhythm 2008 5 : 462 468.
    • (2008) Heart Rhythm , vol.5 , pp. 462-468
    • Tandri, H.1    Zviman, M.M.2    Wedan, S.R.3    Lloyd, T.4    Berger, R.D.5    Halperin, H.6
  • 29
    • 17844400782 scopus 로고    scopus 로고
    • Is asynchronous ventricular pacemaker stimulation dangerous? Results of an international survey
    • Nowak B. Is asynchronous ventricular pacemaker stimulation dangerous? Results of an international survey. Dtsch Med Wochenschr 2005 130 : 997 1001.
    • (2005) Dtsch Med Wochenschr , vol.130 , pp. 997-1001
    • Nowak, B.1
  • 30
    • 31544464618 scopus 로고    scopus 로고
    • Statement of the Working Group of the Germany Society on the safety of asynchronous ventricular pacemaker stimulation
    • Nowak B, Hemmer W, Israel CW, Kramer LI, Neuzner J, Pfeiffer D, Rybak K, et al. Statement of the Working Group of the Germany Society on the safety of asynchronous ventricular pacemaker stimulation. Clin Res Cardiol 2006 95 : 57 60.
    • (2006) Clin Res Cardiol , vol.95 , pp. 57-60
    • Nowak, B.1    Hemmer, W.2    Israel, C.W.3    Kramer, L.I.4    Neuzner, J.5    Pfeiffer, D.6    Rybak, K.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.