Volumn 135, Issue 2, 2014, Pages 646-653

Cavitation thresholds of contrast agents in an in vitro human clot model exposed to 120-kHz ultrasound

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC PRESSURES; CAVITATION THRESHOLDS; CONTRAST AGENT; ECHOGENIC LIPOSOMES; FREQUENCY BAND WIDTH; PASSIVE RECEIVERS; THERAPEUTIC ULTRASOUND; ULTRASOUND CONTRAST AGENT;

EID: 84900643728     PISSN: 00014966     EISSN: None     Source Type: Journal    
DOI: 10.1121/1.4843175     Document Type: Article
Times cited : (24)

References (45)
  • 1
    • 0031722213 scopus 로고    scopus 로고
    • Low-frequency ultrasound penetrates the cranium and enhances thrombolysis in vitro
    • 10.1097/00006123-199810000-00062
    • Akiyama, M., Ishibashi, T., Yamada, T., and Furuhata, H. (1998). "Low-frequency ultrasound penetrates the cranium and enhances thrombolysis in vitro," Neurosurgery 43, 828-832. 10.1097/00006123-199810000-00062
    • (1998) Neurosurgery , vol.43 , pp. 828-832
    • Akiyama, M.1    Ishibashi, T.2    Yamada, T.3    Furuhata, H.4
  • 2
    • 52049091484 scopus 로고    scopus 로고
    • Characterization of ultrasound propagation through ex vivo human temporal bone
    • 10.1016/j.ultrasmedbio.2008.02.012
    • Ammi, A., Mast, T., Huang, I.-H., Abruzzo, T., Coussios, C.-C., Shaw, G., and Holland, C. (2008). "Characterization of ultrasound propagation through ex vivo human temporal bone," Ultrasound Med. Biol. 34, 1578-1589. 10.1016/j.ultrasmedbio.2008.02.012
    • (2008) Ultrasound Med. Biol. , vol.34 , pp. 1578-1589
    • Ammi, A.1    Mast, T.2    Huang, I.-H.3    Abruzzo, T.4    Coussios, C.-C.5    Shaw, G.6    Holland, C.7
  • 3
    • 0019974522 scopus 로고
    • Acoustic cavitation: A possible consequence of biomedical uses of ultrasound
    • Apfel, R. (1982). "Acoustic cavitation: A possible consequence of biomedical uses of ultrasound," Br. J. Cancer Supple. 45 (5), 140-146.
    • (1982) Br. J. Cancer Supple. , vol.45 , Issue.5 , pp. 140-146
    • Apfel, R.1
  • 4
    • 84866695726 scopus 로고    scopus 로고
    • Controlled ultrasound-induced blood-brain barrier disruption using passive acoustic emissions monitoring
    • 10.1371/journal.pone.0045783.t001
    • Arvanitis, C. D., Livingstone, M. S., Vykhodtseva, N., and McDannold, N. (2012). "Controlled ultrasound-induced blood-brain barrier disruption using passive acoustic emissions monitoring," PLoS ONE 7 (9), e45783 10.1371/journal.pone.0045783.t001.
    • (2012) PLoS ONE , vol.7 , Issue.9
    • Arvanitis, C.D.1    Livingstone, M.S.2    Vykhodtseva, N.3    McDannold, N.4
  • 5
    • 0024078510 scopus 로고
    • Thresholds for cavitation produced in water by pulsed ultrasound
    • 10.1016/0041-624X(88)90018-2
    • Atchley, A., Frizzell, L., Apfel, R., Holland, C., Madanshetty, S., and Roy, R. (1988). "Thresholds for cavitation produced in water by pulsed ultrasound," Ultrasonics 26, 280-285. 10.1016/0041-624X(88)90018-2
    • (1988) Ultrasonics , vol.26 , pp. 280-285
    • Atchley, A.1    Frizzell, L.2    Apfel, R.3    Holland, C.4    Madanshetty, S.5    Roy, R.6
  • 6
    • 0024541195 scopus 로고
    • Algorithms for the optimal identification of segment neighborhoods
    • Auger, I. E., and Lawrence, C. E. (1989). "Algorithms for the optimal identification of segment neighborhoods," Bull. Math. Biol. 51, 39-54.
    • (1989) Bull. Math. Biol. , vol.51 , pp. 39-54
    • Auger, I.E.1    Lawrence, C.E.2
  • 7
    • 84871195476 scopus 로고    scopus 로고
    • Gauging the likelihood of stable cavitation from ultrasound contrast agents
    • 10.1088/0031-9155/58/1/127
    • Bader, K. B., and Holland, C. K. (2013). "Gauging the likelihood of stable cavitation from ultrasound contrast agents," Phys.Med.Biol 58, 127-144 10.1088/0031-9155/58/1/127.
    • (2013) Phys.Med.Biol , vol.58 , pp. 127-144
    • Bader, K.B.1    Holland, C.K.2
  • 8
    • 84867361106 scopus 로고    scopus 로고
    • The effect of static pressure on the strength of inertial cavitation events
    • 10.1121/1.4750494
    • Bader, K. B., Mobley, J., Church, C. C., and Gaitan, D. F. (2012). "The effect of static pressure on the strength of inertial cavitation events," J. Acoust. Soc. Am. 132, 2286. 10.1121/1.4750494
    • (2012) J. Acoust. Soc. Am. , vol.132 , pp. 2286
    • Bader, K.B.1    Mobley, J.2    Church, C.C.3    Gaitan, D.F.4
  • 9
    • 33947678729 scopus 로고    scopus 로고
    • Stable and transient subharmonic emissions from isolated contrast agent microbubbles
    • 10.1109/TUFFC.2007.272
    • Biagi, E., Breschi, L., Vannacci, E., and Masotti, L. (2007). "Stable and transient subharmonic emissions from isolated contrast agent microbubbles," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 54, 480-497 10.1109/TUFFC.2007.272.
    • (2007) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.54 , pp. 480-497
    • Biagi, E.1    Breschi, L.2    Vannacci, E.3    Masotti, L.4
  • 10
    • 79751529767 scopus 로고    scopus 로고
    • Microbubbles improve sonothrombolysis in vitro and decrease hemorrhage in vivo in a rabbit stroke model
    • 10.1097/RLI.0b013e318200757a
    • Brown, A. T., Flores, R., Hamilton, E., Roberson, P. K., Borrelli, M. J., and Culp, W. C. (2011). "Microbubbles improve sonothrombolysis in vitro and decrease hemorrhage in vivo in a rabbit stroke model," Invest. Radiol. 46, 202-207 10.1097/RLI.0b013e318200757a.
    • (2011) Invest. Radiol. , vol.46 , pp. 202-207
    • Brown, A.T.1    Flores, R.2    Hamilton, E.3    Roberson, P.K.4    Borrelli, M.J.5    Culp, W.C.6
  • 11
    • 44149111082 scopus 로고    scopus 로고
    • Echogenic liposome compositions for increased retention of ultrasound reflectivity at physiologic temperature
    • 10.1002/jps.21173
    • Buchanan, K. D. K., Huang, S. S., Kim, H. H., Macdonald, R. C. R., and McPherson, D. D. D. (2008). "Echogenic liposome compositions for increased retention of ultrasound reflectivity at physiologic temperature," J. Pharmacol. Sci. 97, 2242-2249 10.1002/jps.21173.
    • (2008) J. Pharmacol. Sci. , vol.97 , pp. 2242-2249
    • Buchanan, K.D.K.1    Huang, S.S.2    Kim, H.H.3    Macdonald, R.C.R.4    McPherson, D.D.D.5
  • 12
    • 13944280025 scopus 로고    scopus 로고
    • Prioritizing interventions to improve rates of thrombolysis for ischemic stroke
    • California Acute Stroke Pilot Registry CASPR Investigators. ",", 10.1212/01.WNL.0000151850.39648.51
    • California Acute Stroke Pilot Registry CASPR Investigators (2005). "Prioritizing interventions to improve rates of thrombolysis for ischemic stroke," Neurology, 64, 654-659 10.1212/01.WNL.0000151850.39648.51.
    • (2005) Neurology , vol.64 , pp. 654-659
  • 13
    • 0037998146 scopus 로고    scopus 로고
    • The pulse length-dependence of inertial cavitation dose and hemolysis
    • 10.1016/S0301-5629(03)00029-2
    • Chen, W.-S., Brayman, A. A., Matula, T. J., Crum, L. A., and Miller, M. W. (2003). "The pulse length-dependence of inertial cavitation dose and hemolysis," Ultrasound Med. Biol. 29, 739-748 10.1016/S0301-5629(03)00029- 2.
    • (2003) Ultrasound Med. Biol. , vol.29 , pp. 739-748
    • Chen, W.-S.1    Brayman, A.A.2    Matula, T.J.3    Crum, L.A.4    Miller, M.W.5
  • 14
    • 25444532746 scopus 로고    scopus 로고
    • In vitro microscopic imaging of enhanced thrombolysis with 120-kHz ultrasound in a human clot model
    • 10.1121/1.1815039
    • Cheng, J., Shaw, G., and Holland, C. (2005). "In vitro microscopic imaging of enhanced thrombolysis with 120-kHz ultrasound in a human clot model," Acoust. Res. Lett. Online, 6, 25-29. 10.1121/1.1815039
    • (2005) Acoust. Res. Lett. Online , vol.6 , pp. 25-29
    • Cheng, J.1    Shaw, G.2    Holland, C.3
  • 15
    • 49849085719 scopus 로고    scopus 로고
    • Ultrasound-enhanced thombolysis using Definity as a cavitation nucleation agent
    • 10.1016/j.ultrasmedbio.2008.01.016
    • Datta, S., Coussios, C.-C., Ammi, A., Mast, T., de Courten-Myers, G., and Holland, C. (2008). "Ultrasound-enhanced thombolysis using Definity as a cavitation nucleation agent," Ultrasound Med. Biol. 34, 1421-1433. 10.1016/j.ultrasmedbio.2008.01.016
    • (2008) Ultrasound Med. Biol. , vol.34 , pp. 1421-1433
    • Datta, S.1    Coussios, C.-C.2    Ammi, A.3    Mast, T.4    De Courten-Myers, G.5    Holland, C.6
  • 17
    • 84864601269 scopus 로고    scopus 로고
    • In vivo characterization of ultrasound contrast agents: Microbubble spectroscopy in a chicken embryo
    • 10.1016/j.ultrasmedbio.2012.05.014
    • Faez, T., Skachkov, I., Versluis, M., Kooiman, K., and de Jong, N. (2012). "In vivo characterization of ultrasound contrast agents: Microbubble spectroscopy in a chicken embryo," Ultrasound Med. Biol. 38, 1608-1617 10.1016/j.ultrasmedbio.2012.05.014.
    • (2012) Ultrasound Med. Biol. , vol.38 , pp. 1608-1617
    • Faez, T.1    Skachkov, I.2    Versluis, M.3    Kooiman, K.4    De Jong, N.5
  • 18
    • 0024023693 scopus 로고
    • Cavitation threshold measurements for microsecond length pulses of ultrasound
    • 10.1121/1.396347
    • Fowlkes, J. B., and Crum, L. A. (1988). "Cavitation threshold measurements for microsecond length pulses of ultrasound," J. Acoust. Soc. Am. 83, 2190-2201. 10.1121/1.396347
    • (1988) J. Acoust. Soc. Am. , vol.83 , pp. 2190-2201
    • Fowlkes, J.B.1    Crum, L.A.2
  • 19
    • 0017964432 scopus 로고
    • Acoustical properties of the human skull
    • 10.1121/1.381852
    • Fry, F., and Barger, J. (1978). "Acoustical properties of the human skull," J. Acoust. Soc. Am. 63, 1576. 10.1121/1.381852
    • (1978) J. Acoust. Soc. Am. , vol.63 , pp. 1576
    • Fry, F.1    Barger, J.2
  • 20
    • 26444608429 scopus 로고    scopus 로고
    • Time and pressure dependence of acoustic signals radiated from microbubbles
    • 10.1016/j.ultrasmedbio.2005.06.014
    • Ganor, Y., Adam, D., and Kimmel, E. (2005). "Time and pressure dependence of acoustic signals radiated from microbubbles," Ultrasound Med. Biol. 31, 1367-1374 10.1016/j.ultrasmedbio.2005.06.014.
    • (2005) Ultrasound Med. Biol. , vol.31 , pp. 1367-1374
    • Ganor, Y.1    Adam, D.2    Kimmel, E.3
  • 21
    • 0141638517 scopus 로고    scopus 로고
    • Ultrasound-mediated cavitation thresholds of liquid perfluorocarbon droplets in vitro
    • 10.1016/S0301-5629(03)00980-3
    • Giesecke, T., and Hynynen, K. (2003). "Ultrasound-mediated cavitation thresholds of liquid perfluorocarbon droplets in vitro," Ultrasound Med. Biol. 29, 1359-1365. 10.1016/S0301-5629(03)00980-3
    • (2003) Ultrasound Med. Biol. , vol.29 , pp. 1359-1365
    • Giesecke, T.1    Hynynen, K.2
  • 23
    • 84871511126 scopus 로고    scopus 로고
    • Deaths: Preliminary data for 2011
    • (Last viewed 07/23/2012)
    • Hoyert, D. L., and Xu, J. (2012). "Deaths: Preliminary data for 2011," Natl. Vital Stat. Rep. 61 (6), 1-65. http://stacks.cdc.gov (Last viewed 07/23/2012).
    • (2012) Natl. Vital Stat. Rep. , vol.61 , Issue.6 , pp. 1-65
    • Hoyert, D.L.1    Xu, J.2
  • 24
    • 67849114631 scopus 로고    scopus 로고
    • Nitric oxide-loaded echogenic liposomes for nitric oxide delivery and inhibition of intimal hyperplasia
    • 10.1016/j.jacc.2009.04.039
    • Huang, S.-L., Kee, P. H., Kim, H., Moody, M. R., Chrzanowski, S. M., MacDonald, R. C., and Mcpherson, D. D. (2009). "Nitric oxide-loaded echogenic liposomes for nitric oxide delivery and inhibition of intimal hyperplasia," J. Am. Coll. Cardiol. 54 (7), 652-659 10.1016/j.jacc.2009.04. 039.
    • (2009) J. Am. Coll. Cardiol. , vol.54 , Issue.7 , pp. 652-659
    • Huang, S.-L.1    Kee, P.H.2    Kim, H.3    Moody, M.R.4    Chrzanowski, S.M.5    Macdonald, R.C.6    McPherson, D.D.7
  • 25
    • 0024764251 scopus 로고
    • Spectral characteristics of acoustic cavitation
    • 10.1016/0041-624X(89)90034-6
    • Ilyichev, V. I. V., Koretz, V. L. V., and Melnikov, N. P. N. (1989). "Spectral characteristics of acoustic cavitation," Ultrasonics 27, 357-361. 10.1016/0041-624X(89)90034-6
    • (1989) Ultrasonics , vol.27 , pp. 357-361
    • Ilyichev, V.I.V.1    Koretz, V.L.V.2    Melnikov, N.P.N.3
  • 27
    • 0041488598 scopus 로고    scopus 로고
    • Ultrasound contrast agents: Development of the Field and current status
    • 10.1007/3-540-46009-8-3
    • Klibanov, A. L. (2002). "Ultrasound contrast agents: Development of the Field and current status," Top. Curr. Chem. 222, 73-106 10.1007/3-540-46009-8-3.
    • (2002) Top. Curr. Chem. , vol.222 , pp. 73-106
    • Klibanov, A.L.1
  • 30
    • 29244447720 scopus 로고    scopus 로고
    • A model for large amplitude oscillations of coated bubbles accounting for buckling and rupture
    • 10.1121/1.2109427
    • Marmottant, P., van der Meer, S., Emmer, M., Versluis, M., de Jong, N., Hilgenfeldt, S., and Lohse, D. (2005). "A model for large amplitude oscillations of coated bubbles accounting for buckling and rupture," J. Acoust. Soc. Am. 118, 3499-3505. 10.1121/1.2109427
    • (2005) J. Acoust. Soc. Am. , vol.118 , pp. 3499-3505
    • Marmottant, P.1    Van Der Meer, S.2    Emmer, M.3    Versluis, M.4    De Jong, N.5    Hilgenfeldt, S.6    Lohse, D.7
  • 31
    • 84863952172 scopus 로고    scopus 로고
    • Temporary disruption of the blood-brain barrier by use of ultrasound and microbubbles: Safety and efficacy evaluation in rhesus macaques
    • 10.1158/0008-5472.CAN-12-0128
    • McDannold, N., Arvanitis, C. D., Vykhodtseva, N., and Livingstone, M. S. (2012). "Temporary disruption of the blood-brain barrier by use of ultrasound and microbubbles: Safety and efficacy evaluation in rhesus macaques," Cancer Res. 72 (14), 3652-3663 10.1158/0008-5472.CAN-12-0128.
    • (2012) Cancer Res. , vol.72 , Issue.14 , pp. 3652-3663
    • McDannold, N.1    Arvanitis, C.D.2    Vykhodtseva, N.3    Livingstone, M.S.4
  • 32
    • 33645513645 scopus 로고    scopus 로고
    • Targeted disruption of the blood-brain barrier with focused ultrasound: Association with cavitation activity
    • 10.1088/0031-9155/51/4/003
    • McDannold, N. N., Vykhodtseva, N. N., and Hynynen, K. K. (2006). "Targeted disruption of the blood-brain barrier with focused ultrasound: Association with cavitation activity," Phys. Med. Biol. 51, 793-807 10.1088/0031-9155/51/4/003.
    • (2006) Phys. Med. Biol. , vol.51 , pp. 793-807
    • McDannold, N.N.1    Vykhodtseva, N.N.2    Hynynen, K.K.3
  • 33
    • 33644851343 scopus 로고    scopus 로고
    • Microbubble administration accelerates clot lysis during continuous 2-MHz ultrasound monitoring in stroke patients treated with intravenous tissue plasminogen activator
    • 10.1161/01.STR.0000199064.94588.39
    • Molina, C., Ribo, M., Rubiera, M., Montaner, J., Santamarina, E., Delgado-Mederos, R., Arenillas, J., Huertas, R., Purroy, F., Delgado, P., and Alvarez-Sabin, J. (2006). "Microbubble administration accelerates clot lysis during continuous 2-MHz ultrasound monitoring in stroke patients treated with intravenous tissue plasminogen activator," Stroke 37, 425-429. 10.1161/01.STR.0000199064.94588.39
    • (2006) Stroke , vol.37 , pp. 425-429
    • Molina, C.1    Ribo, M.2    Rubiera, M.3    Montaner, J.4    Santamarina, E.5    Delgado-Mederos, R.6    Arenillas, J.7    Huertas, R.8    Purroy, F.9    Delgado, P.10    Alvarez-Sabin, J.11
  • 34
    • 0014574534 scopus 로고
    • Subharmonic and other low-frequency emission from bubbles in sound-irradiated liquids
    • Neppiras, E. (1969). "Subharmonic and other low-frequency emission from bubbles in sound-irradiated liquids," J. Acoust. Soc. Am. 46, 567-601.
    • (1969) J. Acoust. Soc. Am. , vol.46 , pp. 567-601
    • Neppiras, E.1
  • 35
    • 84861319114 scopus 로고    scopus 로고
    • Blood-brain barrier: Real-time feedback-controlled focused ultrasound disruption by using an acoustic emissions-based controller
    • 10.1148/radiol.11111417
    • Oreilly, M. A., and Hynynen, K. (2012). "Blood-brain barrier: Real-time feedback-controlled focused ultrasound disruption by using an acoustic emissions-based controller," Radiology 263 (1), 96-106 10.1148/radiol.11111417.
    • (2012) Radiology , vol.263 , Issue.1 , pp. 96-106
    • Oreilly, M.A.1    Hynynen, K.2
  • 36
    • 84867027919 scopus 로고    scopus 로고
    • Stability of echogenic liposomes as a blood pool ultrasound contrast agent in a physiologic flow phantom
    • 10.1016/j.ultrasmedbio.2012.06.012
    • Radhakrishnan, K., Haworth, K. J., Huang, S.-L., Klegerman, M. E., Mcpherson, D. D., and Holland, C. K. (2012). "Stability of echogenic liposomes as a blood pool ultrasound contrast agent in a physiologic flow phantom," Ultrasound Med. Biol. 38, 1970-1981 10.1016/j.ultrasmedbio.2012. 06.012.
    • (2012) Ultrasound Med. Biol. , vol.38 , pp. 1970-1981
    • Radhakrishnan, K.1    Haworth, K.J.2    Huang, S.-L.3    Klegerman, M.E.4    McPherson, D.D.5    Holland, C.K.6
  • 38
    • 33750302894 scopus 로고    scopus 로고
    • Detection of acoustic cavitation in the heart with microbubble contrast agents in vivo: A mechanism for ultrasound- induced arrhythmias
    • 10.1121/1.2346132
    • Rota, C., Raeman, C. H., Child, S. Z., and Dalecki, D. (2006). "Detection of acoustic cavitation in the heart with microbubble contrast agents in vivo: A mechanism for ultrasound- induced arrhythmias," J. Acoust. Soc. Am. 120, 2958-2964. 10.1121/1.2346132
    • (2006) J. Acoust. Soc. Am. , vol.120 , pp. 2958-2964
    • Rota, C.1    Raeman, C.H.2    Child, S.Z.3    Dalecki, D.4
  • 39
    • 67649353301 scopus 로고    scopus 로고
    • Spectral and temporal signal modifications occuring between stable and transient inertial cavitation
    • 10.1109/ULTSYM.2008.0239
    • Santin, M., Bridal, S. L., Haak, A., and O'Brien, W. D. (2008). "Spectral and temporal signal modifications occuring between stable and transient inertial cavitation," The 2008 IEEE Ultrasonics Symposium (IUS), pp. 989-992. 10.1109/ULTSYM.2008.0239
    • (2008) The 2008 IEEE Ultrasonics Symposium (IUS) , pp. 989-992
    • Santin, M.1    Bridal, S.L.2    Haak, A.3    O'Brien, W.D.4
  • 40
    • 44149124040 scopus 로고    scopus 로고
    • Response of contrast agents to ultrasound
    • 10.1016/j.addr.2008.03.011
    • Sboros, V. (2008). "Response of contrast agents to ultrasound," Adv. Drug Deliv. Rev. 60, 1117-1136 10.1016/j.addr.2008.03.011.
    • (2008) Adv. Drug Deliv. Rev. , vol.60 , pp. 1117-1136
    • Sboros, V.1
  • 41
    • 67649690472 scopus 로고    scopus 로고
    • Ultrasound-enhanced thrombolysis with tPA-loaded echogenic liposomes
    • 10.1016/j.thromres.2009.01.008
    • Shaw, G., Meunier, J., Huang, S.-L., Lindsell, C., McPherson, D., and Holland, C. (2009). "Ultrasound-enhanced thrombolysis with tPA-loaded echogenic liposomes," Thombosis Res. 124, 306-310. 10.1016/j.thromres.2009. 01.008
    • (2009) Thombosis Res. , vol.124 , pp. 306-310
    • Shaw, G.1    Meunier, J.2    Huang, S.-L.3    Lindsell, C.4    McPherson, D.5    Holland, C.6
  • 42
    • 54049131779 scopus 로고    scopus 로고
    • Tissue plasminogen activator concentration dependence of 120 kHz ultrasound-enhanced thrombolysis
    • 10.1016/j.ultrasmedbio.2008.03.020
    • Shaw, G. J., Meunier, J. M., Lindsell, C. J., and Holland, C. K. (2008). "Tissue plasminogen activator concentration dependence of 120 kHz ultrasound-enhanced thrombolysis," Ultrasound Med. Biol. 34, 1783-1792 10.1016/j.ultrasmedbio.2008.03.020.
    • (2008) Ultrasound Med. Biol. , vol.34 , pp. 1783-1792
    • Shaw, G.J.1    Meunier, J.M.2    Lindsell, C.J.3    Holland, C.K.4
  • 43
    • 84919344000 scopus 로고    scopus 로고
    • Ambient pressure dependence of the ultra-harmonic response from contrast microbubbles
    • 10.1121/1.4707512
    • Sun, T., Jia, N., Zhang, D., and Xu, D. (2012). "Ambient pressure dependence of the ultra-harmonic response from contrast microbubbles," J. Acoust. Soc. Am. 131, 4358-4364. 10.1121/1.4707512
    • (2012) J. Acoust. Soc. Am. , vol.131 , pp. 4358-4364
    • Sun, T.1    Jia, N.2    Zhang, D.3    Xu, D.4
  • 44
    • 0032543535 scopus 로고    scopus 로고
    • In vitro studies of a new thrombus-specific ultrasound contrast agent
    • 10.1016/S0002-9149(98)00055-1
    • Unger, E., McCreery, T., Sweitzer, R., Shen, D., and Wu, G. (1998). "In vitro studies of a new thrombus-specific ultrasound contrast agent," Am. J. Cardiol. 81, 58G-61G. 10.1016/S0002-9149(98)00055-1
    • (1998) Am. J. Cardiol. , vol.81
    • Unger, E.1    McCreery, T.2    Sweitzer, R.3    Shen, D.4    Wu, G.5
  • 45
    • 47549099626 scopus 로고    scopus 로고
    • Effects of acoustic insonation parameters on ultrasound contrast agent destruction
    • 10.1016/j.ultrasmedbio.2007.12.020
    • Yeh, C.-K., and Su, S.-Y. (2008). "Effects of acoustic insonation parameters on ultrasound contrast agent destruction," Ultrasound Med. Biol. 34, 1281-1291 10.1016/j.ultrasmedbio.2007.12.020.
    • (2008) Ultrasound Med. Biol. , vol.34 , pp. 1281-1291
    • Yeh, C.-K.1    Su, S.-Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.