메뉴 건너뛰기




Volumn 187, Issue 2, 2014, Pages 471-483

Radiofrequency-assisted versus clamp-crush liver resection: A systematic review and meta-analysis

Author keywords

Clamp crush liver resection; Meta analysis; Radiofrequency assisted liver resection; Systematic review

Indexed keywords

ABDOMINAL ABSCESS; ARTICLE; BILE LEAKAGE; BLOOD TRANSFUSION; CLAMP CRUSH LIVER RESECTION; COMPARATIVE EFFECTIVENESS; DISEASE ASSOCIATION; HUMAN; INCIDENCE; LIVER RESECTION; META ANALYSIS; OPERATIVE BLOOD LOSS; PATIENT SAFETY; PRIORITY JOURNAL; RADIOFREQUENCY ABLATION; RADIOFREQUENCY ASSISTED LIVER RESECTION; RANDOMIZED CONTROLLED TRIAL (TOPIC); SYSTEMATIC REVIEW;

EID: 84900525382     PISSN: 00224804     EISSN: 10958673     Source Type: Journal    
DOI: 10.1016/j.jss.2013.10.055     Document Type: Article
Times cited : (16)

References (37)
  • 1
    • 79952190360 scopus 로고    scopus 로고
    • Selection criteria for hepatectomy in patients with hepatocellular carcinoma classified as Child-Pugh class B
    • S. Kuroda, H. Tashiro, T. Kobayashi, A. Oshita, H. Amano, and H. Ohdan Selection criteria for hepatectomy in patients with hepatocellular carcinoma classified as Child-Pugh class B World J Surg 35 2011 834
    • (2011) World J Surg , vol.35 , pp. 834
    • Kuroda, S.1    Tashiro, H.2    Kobayashi, T.3    Oshita, A.4    Amano, H.5    Ohdan, H.6
  • 2
    • 0036221690 scopus 로고    scopus 로고
    • The vascular control in liver resection: Revisitation of a controversial issue
    • G. Torzilli, M. Makuuchi, and K. Inohue The vascular control in liver resection: revisitation of a controversial issue Hepatogastroenterology 49 2002 28
    • (2002) Hepatogastroenterology , vol.49 , pp. 28
    • Torzilli, G.1    Makuuchi, M.2    Inohue, K.3
  • 3
    • 0037775811 scopus 로고    scopus 로고
    • Influence of transfusions on perioperative and long-term outcome in patients following hepatic resection for colorectal metastases
    • D.A. Kooby, J. Stockman, L. Ben-Porat, and G.B. Doglietto Influence of transfusions on perioperative and long-term outcome in patients following hepatic resection for colorectal metastases Ann Surg 237 2003 860
    • (2003) Ann Surg , vol.237 , pp. 860
    • Kooby, D.A.1    Stockman, J.2    Ben-Porat, L.3    Doglietto, G.B.4
  • 4
    • 33745507761 scopus 로고    scopus 로고
    • Intraoperative blood loss is a risk factor for complications in donors after living donor hepatectomy
    • S. Ibrahim, C.L. Chen, and C.C. Lin et al. Intraoperative blood loss is a risk factor for complications in donors after living donor hepatectomy Liver Transpl 12 2006 950
    • (2006) Liver Transpl , vol.12 , pp. 950
    • Ibrahim, S.1    Chen, C.L.2    Lin, C.C.3
  • 5
    • 33845669834 scopus 로고    scopus 로고
    • Outcomes and recurrence of initially resectable hepatocellular carcinoma meeting Milan criteria: Rationale for partial hepatectomy as first strategy
    • S. Tanaka, N. Noguchi, and T. Ochiai et al. Outcomes and recurrence of initially resectable hepatocellular carcinoma meeting Milan criteria: rationale for partial hepatectomy as first strategy J Am Coll Surg 204 2007 1
    • (2007) J Am Coll Surg , vol.204 , pp. 1
    • Tanaka, S.1    Noguchi, N.2    Ochiai, T.3
  • 6
    • 0027067795 scopus 로고
    • Hepatic resections for primary and metastatic tumors using the ultrasonic surgical dissector
    • W.J. Hodgson, J. Morgan, D. Byrne, and L.R. DelGuercio Hepatic resections for primary and metastatic tumors using the ultrasonic surgical dissector Am J Surg 163 1992 246
    • (1992) Am J Surg , vol.163 , pp. 246
    • Hodgson, W.J.1    Morgan, J.2    Byrne, D.3    Delguercio, L.R.4
  • 9
    • 60449093000 scopus 로고    scopus 로고
    • Meta-analysis of the clamp-crushing technique for transection of the parenchyma in elective hepatic resection: Back to where we started?
    • N.N. Rahbari, M. Koch, and T. Schmidt et al. Meta-analysis of the clamp-crushing technique for transection of the parenchyma in elective hepatic resection: back to where we started? Ann Surg Oncol 16 2009 630
    • (2009) Ann Surg Oncol , vol.16 , pp. 630
    • Rahbari, N.N.1    Koch, M.2    Schmidt, T.3
  • 10
    • 70349188513 scopus 로고    scopus 로고
    • Techniques for liver parenchymal transection: A meta-analysis of randomized controlled trials
    • V. Pamecha, K.S. Gurusamy, D. Sharma, and B.R. Davidson Techniques for liver parenchymal transection: a meta-analysis of randomized controlled trials HPB (Oxford) 11 2009 275
    • (2009) HPB (Oxford) , vol.11 , pp. 275
    • Pamecha, V.1    Gurusamy, K.S.2    Sharma, D.3    Davidson, B.R.4
  • 13
    • 0033855610 scopus 로고    scopus 로고
    • Protective effects of ischemic preconditioning for liver resection performed under inflow occlusion in humans
    • P.A. Clavien, S. Yadav, D. Sindram, and R.C. Bentley Protective effects of ischemic preconditioning for liver resection performed under inflow occlusion in humans Ann Surg 232 2000 155
    • (2000) Ann Surg , vol.232 , pp. 155
    • Clavien, P.A.1    Yadav, S.2    Sindram, D.3    Bentley, R.C.4
  • 14
    • 85027921523 scopus 로고    scopus 로고
    • Radiofrequency-assisted hepatic resection
    • M. Pai, C. Kyriakides, and S. Mikhail et al. Radiofrequency-assisted hepatic resection Ann Surg Oncol 18 2011 3391
    • (2011) Ann Surg Oncol , vol.18 , pp. 3391
    • Pai, M.1    Kyriakides, C.2    Mikhail, S.3
  • 15
    • 42449120612 scopus 로고    scopus 로고
    • Liver resection with a new multiprobe bipolar radiofrequency device
    • A. Ayav, L. Jiao, and R. Dickinson et al. Liver resection with a new multiprobe bipolar radiofrequency device Arch Surg 143 2008 396
    • (2008) Arch Surg , vol.143 , pp. 396
    • Ayav, A.1    Jiao, L.2    Dickinson, R.3
  • 17
    • 55749097043 scopus 로고    scopus 로고
    • Radiofrequency assisted liver resection in cirrhotic patients with hepatocellular carcinoma
    • G. Curro, L. Jiao, and C. Scisca et al. Radiofrequency assisted liver resection in cirrhotic patients with hepatocellular carcinoma J Surg Oncol 98 2008 407
    • (2008) J Surg Oncol , vol.98 , pp. 407
    • Curro, G.1    Jiao, L.2    Scisca, C.3
  • 18
    • 12444322676 scopus 로고    scopus 로고
    • Liver resection using a saline linked radiofrequency dissecting sealer for transection of the liver
    • R.T. Poon, S.T. Fan, and J. Wong Liver resection using a saline linked radiofrequency dissecting sealer for transection of the liver J Am Coll Surg 200 2005 308
    • (2005) J Am Coll Surg , vol.200 , pp. 308
    • Poon, R.T.1    Fan, S.T.2    Wong, J.3
  • 19
    • 68549101842 scopus 로고    scopus 로고
    • The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: Explanation and elaboration
    • A. Liberati, D.G. Altman, and J. Tetzlaff et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration BMJ 339 2009 b2700
    • (2009) BMJ , vol.339 , pp. 2700
    • Liberati, A.1    Altman, D.G.2    Tetzlaff, J.3
  • 21
    • 0029914622 scopus 로고    scopus 로고
    • Assessing the quality of reports of randomized clinical trials: Is blinding necessary?
    • A.R. Jadad, R.A. Moore, and D. Carroll et al. Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials 17 1996 1
    • (1996) Control Clin Trials , vol.17 , pp. 1
    • Jadad, A.R.1    Moore, R.A.2    Carroll, D.3
  • 22
    • 0035883898 scopus 로고    scopus 로고
    • Effect of arterial revascularization on survival: A systematic review of studies comparing bilateral and single internal mammary arteries
    • D.P. Taggart, R. D'Amico, and D.G. Altman Effect of arterial revascularization on survival: a systematic review of studies comparing bilateral and single internal mammary arteries Lancet 358 2001 870
    • (2001) Lancet , vol.358 , pp. 870
    • Taggart, D.P.1    D'Amico, R.2    Altman, D.G.3
  • 24
    • 21544449115 scopus 로고    scopus 로고
    • Estimating the mean and variance from the median, range, and the size of a sample
    • S.P. Hozo, B. Djulbegovic, and I. Hozo Estimating the mean and variance from the median, range, and the size of a sample BMC Med Res Methodol 5 2005 13
    • (2005) BMC Med Res Methodol , vol.5 , pp. 13
    • Hozo, S.P.1    Djulbegovic, B.2    Hozo, I.3
  • 25
    • 28244445414 scopus 로고    scopus 로고
    • How should transection of the liver be performed? A prospective randomized study in 100 consecutive patients: Comparing four different transection strategies
    • M. Lesurtel, M. Selzner, H. Petrowsky, L. McCormack, and P.A. Clavien How should transection of the liver be performed? A prospective randomized study in 100 consecutive patients: comparing four different transection strategies Ann Surg 242 2005 814
    • (2005) Ann Surg , vol.242 , pp. 814
    • Lesurtel, M.1    Selzner, M.2    Petrowsky, H.3    McCormack, L.4    Clavien, P.A.5
  • 26
    • 23844501035 scopus 로고    scopus 로고
    • Randomized clinical trial of the effect of a saline-linked radiofrequency coagulator on blood loss during hepatic resection
    • J. Arita, K. Hasegawa, N. Kokudo, K. Sano, Y. Sugawara, and M. Makuuchi Randomized clinical trial of the effect of a saline-linked radiofrequency coagulator on blood loss during hepatic resection Br J Surg 92 2005 954
    • (2005) Br J Surg , vol.92 , pp. 954
    • Arita, J.1    Hasegawa, K.2    Kokudo, N.3    Sano, K.4    Sugawara, Y.5    Makuuchi, M.6
  • 27
    • 33947246194 scopus 로고    scopus 로고
    • Randomized clinical trial of radiofrequency-assisted versus clamp-crushing liver resection
    • L. Lupo, A. Gallerani, P. Panzera, F. Tandoi, G. Di Palma, and V. Memeo Randomized clinical trial of radiofrequency-assisted versus clamp-crushing liver resection Br J Surg 94 2007 287
    • (2007) Br J Surg , vol.94 , pp. 287
    • Lupo, L.1    Gallerani, A.2    Panzera, P.3    Tandoi, F.4    Di Palma, G.5    Memeo, V.6
  • 28
    • 84876667959 scopus 로고    scopus 로고
    • Radiofrequency-assisted versus clamp-crushing parenchyma transection in cirrhotic patients with hepatocellular carcinoma: A randomized clinical trial
    • M. Li, W. Zhang, and Y. Li et al. Radiofrequency-assisted versus clamp-crushing parenchyma transection in cirrhotic patients with hepatocellular carcinoma: a randomized clinical trial Dig Dis Sci 58 2013 835
    • (2013) Dig Dis Sci , vol.58 , pp. 835
    • Li, M.1    Zhang, W.2    Li, Y.3
  • 29
    • 54549108058 scopus 로고    scopus 로고
    • A clinical comparative analysis of crush/clamp, stapler, and dissecting sealer hepatic transection methods
    • E.T. Castaldo, T.M. Earl, and R.S. Chari et al. A clinical comparative analysis of crush/clamp, stapler, and dissecting sealer hepatic transection methods HPB (Oxford) 10 2008 321
    • (2008) HPB (Oxford) , vol.10 , pp. 321
    • Castaldo, E.T.1    Earl, T.M.2    Chari, R.S.3
  • 30
    • 48949102171 scopus 로고    scopus 로고
    • The use of saline-linked radiofrequency dissecting sealer for liver transection in patients with cirrhosis
    • F. Xia, S. Wang, K. Ma, X. Feng, Y. Su, and J. Dong The use of saline-linked radiofrequency dissecting sealer for liver transection in patients with cirrhosis J Surg Res 149 2008 110
    • (2008) J Surg Res , vol.149 , pp. 110
    • Xia, F.1    Wang, S.2    Ma, K.3    Feng, X.4    Su, Y.5    Dong, J.6
  • 31
    • 70349182548 scopus 로고    scopus 로고
    • Clamp-crush technique vs radiofrequency-assisted liver resection for primary and metastatic liver neoplasms
    • S. Delis, A. Bakoyiannis, and N. Tassopoulos et al. Clamp-crush technique vs. radiofrequency-assisted liver resection for primary and metastatic liver neoplasms HPB (Oxford) 11 2009 339
    • (2009) HPB (Oxford) , vol.11 , pp. 339
    • Delis, S.1    Bakoyiannis, A.2    Tassopoulos, N.3
  • 32
    • 80755156393 scopus 로고    scopus 로고
    • Minor hepatic resection for hepatocellular carcinoma in cirrhotic patients: Kelly clamp crushing resection versus heat coagulative necrosis with bipolar radiofrequency device
    • L. Sandonato, M. Soresi, and C. Cipolla et al. Minor hepatic resection for hepatocellular carcinoma in cirrhotic patients: Kelly clamp crushing resection versus heat coagulative necrosis with bipolar radiofrequency device Am Surg 77 2011 1490
    • (2011) Am Surg , vol.77 , pp. 1490
    • Sandonato, L.1    Soresi, M.2    Cipolla, C.3
  • 33
    • 84868560722 scopus 로고    scopus 로고
    • Radiofrequency-assisted liver resection with a comb-shaped bipolar device versus clamp crushing: A clinical study
    • G. Galizia, P. Castellano, and M. Pinto et al. Radiofrequency-assisted liver resection with a comb-shaped bipolar device versus clamp crushing: a clinical study Surg Innov 19 2012 407
    • (2012) Surg Innov , vol.19 , pp. 407
    • Galizia, G.1    Castellano, P.2    Pinto, M.3
  • 34
    • 79959545682 scopus 로고    scopus 로고
    • Radiofrequency-assisted liver resection: Higher incidence of infectious complications?
    • Z. Subrt, A. Ferko, B. Jon, and F. Cecka Radiofrequency-assisted liver resection: higher incidence of infectious complications? Acta Chir Belg 111 2011 165
    • (2011) Acta Chir Belg , vol.111 , pp. 165
    • Subrt, Z.1    Ferko, A.2    Jon, B.3    Cecka, F.4
  • 35
    • 0035159787 scopus 로고    scopus 로고
    • Bile leakage after hepatic resection
    • Y. Yamashita, T. Hamatsu, and T. Rikimaru et al. Bile leakage after hepatic resection Ann Surg 233 2011 45
    • (2011) Ann Surg , vol.233 , pp. 45
    • Yamashita, Y.1    Hamatsu, T.2    Rikimaru, T.3
  • 36
    • 84856523978 scopus 로고    scopus 로고
    • Radiofrequency assisted liver resection: Analysis of 604 consecutive cases
    • M. Pai, A.E. Frampton, and S. Mikhail et al. Radiofrequency assisted liver resection: analysis of 604 consecutive cases Eur J Surg Oncol 38 2012 274
    • (2012) Eur J Surg Oncol , vol.38 , pp. 274
    • Pai, M.1    Frampton, A.E.2    Mikhail, S.3
  • 37
    • 0037097838 scopus 로고    scopus 로고
    • Randomised trials in surgery: Problems and possible solutions
    • P. McCulloch, I. Taylor, M. Sasako, B. Lovett, and D. Griffin Randomised trials in surgery: problems and possible solutions BMJ 324 2002 1448
    • (2002) BMJ , vol.324 , pp. 1448
    • McCulloch, P.1    Taylor, I.2    Sasako, M.3    Lovett, B.4    Griffin, D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.