메뉴 건너뛰기




Volumn 47, Issue 33, 2000, Pages 763-766

Initial experience with the harmonic scalpel in liver surgery

Author keywords

Harmonic scalpel; Liver surgery

Indexed keywords

ADULT; AGED; ARTICLE; BLEEDING; CLINICAL ARTICLE; DISSECTION; FEMALE; HEMOSTASIS; HUMAN; LIVER CARCINOMA; LIVER CIRRHOSIS; LIVER CYST; LIVER METASTASIS; LIVER PARENCHYMA; LIVER RESECTION; LIVER SURGERY; MALE; PRIORITY JOURNAL; PROSPECTIVE STUDY; SCALPEL; ULTRASOUND;

EID: 0034101090     PISSN: 01726390     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (38)

References (12)
  • 1
    • 0026600166 scopus 로고
    • The importance of Glisson's capsule and its sheaths in the intrahepatic approach to resection of the liver
    • 1 Launois B, Jamieson GG: The importance of Glisson's capsule and its sheaths in the intrahepatic approach to resection of the liver. Surg Gynecol Obst 1992; 174:7-10.
    • (1992) Surg Gynecol Obst , vol.174 , pp. 7-10
    • Launois, B.1    Jamieson, G.G.2
  • 2
    • 0030033337 scopus 로고    scopus 로고
    • Hepatectomy with an ultrasonic dissector for hepatocellular carcinoma
    • 2 Fan ST, Lai ECS, Lo CM, Chu KM, Liu CL, Wong J: Hepatectomy with an ultrasonic dissector for hepatocellular carcinoma. Br J Surg 1996; 83:117-120.
    • (1996) Br J Surg , vol.83 , pp. 117-120
    • Fan, S.T.1    Lai, E.C.S.2    Lo, C.M.3    Chu, K.M.4    Liu, C.L.5    Wong, J.6
  • 3
    • 0027067795 scopus 로고    scopus 로고
    • Hepatic resection for primary and metastatic tumors using the ultrasonic surgical dissector
    • 3 Hodgson WJB, Morgan J, Byrne D, DelGuercio LRM: Hepatic resection for primary and metastatic tumors using the ultrasonic surgical dissector. Am J Surg 1996; 163:246-250.
    • (1996) Am J Surg , vol.163 , pp. 246-250
    • Hodgson, W.J.B.1    Morgan, J.2    Byrne, D.3    DelGuercio, L.R.M.4
  • 5
    • 0028213002 scopus 로고
    • The experimental development of an ultrasonically activated scalpel for laparoscopic use
    • 5 Amaral JF: The experimental development of an ultrasonically activated scalpel for laparoscopic use. Surg Laparosc Endosc 1994; 2:92-99.
    • (1994) Surg Laparosc Endosc , vol.2 , pp. 92-99
    • Amaral, J.F.1
  • 6
    • 0030908251 scopus 로고    scopus 로고
    • Laparoscopic pull-through procedures using the harmonic scalpel in infants and children with Hirschprung's disease
    • 6 Rothenberg SS, Chang JH: Laparoscopic pull-through procedures using the harmonic scalpel in infants and children with Hirschprung's disease. J Pediatr Surg 1997; 32:894-896.
    • (1997) J Pediatr Surg , vol.32 , pp. 894-896
    • Rothenberg, S.S.1    Chang, J.H.2
  • 7
    • 0030787878 scopus 로고    scopus 로고
    • Thoracoscopic internal mammary artery harvest for MICABG using the harmonic scalpel
    • 7 Ohtsuka T, Wolf RK, Hiratzka LF, Wurnig P, Flege JB: Thoracoscopic internal mammary artery harvest for MICABG using the harmonic scalpel. Ann Thorac Surg 1997; 63:S107-109.
    • (1997) Ann Thorac Surg , vol.63
    • Ohtsuka, T.1    Wolf, R.K.2    Hiratzka, L.F.3    Wurnig, P.4    Flege, J.B.5
  • 8
    • 0031736813 scopus 로고    scopus 로고
    • Perioperative outcomes of major hepatic resections under low central venous pressure anesthesia: Blood loss, blood transfusion, and the risk of postoperative renal dysfunction
    • 8 Melendez JA, Arslan V, Fischer ME, Wuest D, Jarnagin WR, Fong Y, Blumgart LH: Perioperative outcomes of major hepatic resections under low central venous pressure anesthesia: Blood loss, blood transfusion, and the risk of postoperative renal dysfunction. J Am Coll Surg 1998; 187:620-625.
    • (1998) J Am Coll Surg , vol.187 , pp. 620-625
    • Melendez, J.A.1    Arslan, V.2    Fischer, M.E.3    Wuest, D.4    Jarnagin, W.R.5    Fong, Y.6    Blumgart, L.H.7
  • 9
    • 0031445926 scopus 로고    scopus 로고
    • Prospective evaluation of Pringle maneuver in hepatectomy for liver tumors by a randomized study
    • 9 Man K, Fan ST, Ng IOL, Lo CM, Liu CL, Wong J: Prospective evaluation of Pringle maneuver in hepatectomy for liver tumors by a randomized study. Ann Surg 1997; 226:704-713.
    • (1997) Ann Surg , vol.226 , pp. 704-713
    • Man, K.1    Fan, S.T.2    Ng, I.O.L.3    Lo, C.M.4    Liu, C.L.5    Wong, J.6
  • 10
    • 0029781889 scopus 로고    scopus 로고
    • Physiologic mechanism of the ultrasonically activated scalpel
    • 10 McCarus SD: Physiologic mechanism of the ultrasonically activated scalpel. J Am Assoc Gynecol Laparosc 1996; 3:601-608.
    • (1996) J Am Assoc Gynecol Laparosc , vol.3 , pp. 601-608
    • McCarus, S.D.1
  • 11
    • 0028458691 scopus 로고
    • Medicotechnical basics of surgery using invasive ultrasonic energy
    • 11 Mueller W, Fritzsch G: Medicotechnical basics of surgery using invasive ultrasonic energy. End Surg 1994; 2:205-210.
    • (1994) End Surg , vol.2 , pp. 205-210
    • Mueller, W.1    Fritzsch, G.2
  • 12
    • 0013692547 scopus 로고    scopus 로고
    • Viability of airborne cancer cells released by ultrasonic cavitation and electrosurgery
    • 12 Nduka CC, Dye JF, Mansfield AO, Darzi A: Viability of airborne cancer cells released by ultrasonic cavitation and electrosurgery. Br J Surg 1997; 84:720.
    • (1997) Br J Surg , vol.84 , pp. 720
    • Nduka, C.C.1    Dye, J.F.2    Mansfield, A.O.3    Darzi, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.