메뉴 건너뛰기




Volumn 10, Issue 4, 2008, Pages 256-260

Liver resection with bipolar radiofrequency device: Habib™ 4X

Author keywords

Blood loss; Habib 4X; Liver resection; Parenchymal transection device; Radiofrequency

Indexed keywords

ADULT; BILE DUCT; BILE LEAKAGE; BIPOLAR RADIOFREQUENCY DEVICE; BLEEDING; BLOOD TRANSFUSION; BLOOD VESSEL; BLOOD VESSEL OCCLUSION; CONTROLLED STUDY; ELECTRODE; FEMALE; HEAT; HUMAN; INTRAOPERATIVE PERIOD; LIVER PARENCHYMA; LIVER RESECTION; LIVER SURGERY; MAJOR CLINICAL STUDY; MALE; POSTOPERATIVE COMPLICATION; RADIOFREQUENCY; RADIOFREQUENCY ABLATION; REVIEW; SCALPEL; SURGEON; SURGICAL EQUIPMENT; SURGICAL MORTALITY; SURGICAL PATIENT; SURGICAL TECHNIQUE;

EID: 49049091996     PISSN: 1365182X     EISSN: 14772574     Source Type: Journal    
DOI: 10.1080/13651820802167136     Document Type: Review
Times cited : (59)

References (30)
  • 1
    • 0033922244 scopus 로고    scopus 로고
    • Seven hundred forty-seven hepatectomies in the 1990s: An update to evaluate the actual risk of liver resection
    • Belghiti, J., Hiramatsu, K., Benoist, S., Massault, P., Sauvanet, A. and Farges, O. (2000) Seven hundred forty-seven hepatectomies in the 1990s: an update to evaluate the actual risk of liver resection. J Am Coll Surg, 191, pp. 38-46.
    • (2000) J Am Coll Surg , vol.191 , pp. 38-46
    • Belghiti, J.1    Hiramatsu, K.2    Benoist, S.3    Massault, P.4    Sauvanet, A.5    Farges, O.6
  • 2
    • 0036786635 scopus 로고    scopus 로고
    • Improvement in perioperative outcome after hepatic resection: Analysis of 1,803 consecutive cases over the past decade
    • Jarnagin, WR, Gonen, M., Fong, Y., DeMatteo, RP, Ben-Porat, L. Little, S. et al. (2002) Improvement in perioperative outcome after hepatic resection: Analysis of 1,803 consecutive cases over the past decade. Ann Surg, 236, pp. 397-406.
    • (2002) Ann Surg , vol.236 , pp. 397-406
    • Jarnagin, W.R.1    Gonen, M.2    Fong, Y.3    DeMatteo, R.P.4    Ben-Porat, L.5    Little, S.6
  • 3
    • 4644258425 scopus 로고    scopus 로고
    • Improving perioperative outcome expands the role of hepatectomy in management of benign and malignant hepatobiliary diseases: Analysis of 1222 consecutive patients from a prospective database
    • Poon, RT, Fan, ST, Lo, CM, Liu, CL, Lam, CM Yuen, WK et al. (2004) Improving perioperative outcome expands the role of hepatectomy in management of benign and malignant hepatobiliary diseases: Analysis of 1222 consecutive patients from a prospective database. Ann Surg, 240, pp. 698-708.
    • (2004) Ann Surg , vol.240 , pp. 698-708
    • Poon, R.T.1    Fan, S.T.2    Lo, C.M.3    Liu, C.L.4    Lam, C.M.5    Yuen, W.K.6
  • 5
    • 0033020179 scopus 로고    scopus 로고
    • Reduction of transfusion requirements during major hepatic resection for metastatic disease
    • Arnoletti, JP and Brodsky, J. (1999) Reduction of transfusion requirements during major hepatic resection for metastatic disease. Surgery, 125, pp. 166-171.
    • (1999) Surgery , vol.125 , pp. 166-171
    • Arnoletti, J.P.1    Brodsky, J.2
  • 6
    • 0028107261 scopus 로고
    • Perioperative predictors of morbidity following hepatic resection for neoplasm. A multivariate analysis of a single surgeon experience with 105 patients
    • Sitzmann, JV and Greene, PS. (1994) Perioperative predictors of morbidity following hepatic resection for neoplasm. A multivariate analysis of a single surgeon experience with 105 patients. Ann Surg, 219, pp. 13-17.
    • (1994) Ann Surg , vol.219 , pp. 13-17
    • Sitzmann, J.V.1    Greene, P.S.2
  • 7
    • 0024362693 scopus 로고
    • Major hepatic resection under total vascular exclusion
    • Bismuth, H., Castaing, D. and Garden, OJ. (1989) Major hepatic resection under total vascular exclusion. Ann Surg, 210, pp. 13-19.
    • (1989) Ann Surg , vol.210 , pp. 13-19
    • Bismuth, H.1    Castaing, D.2    Garden, O.J.3
  • 8
    • 0024313803 scopus 로고
    • Restrictive versus liberal blood transfusion policy for hepatectomies in cirrhotic patients
    • Makuuchi, M., Takayama, T., Gunven, P., Kosuge, T., Yamazaki, S. and Hasegawa, H. (1989) Restrictive versus liberal blood transfusion policy for hepatectomies in cirrhotic patients. World J Surg, 13, pp. 644-648.
    • (1989) World J Surg , vol.13 , pp. 644-648
    • Makuuchi, M.1    Takayama, T.2    Gunven, P.3    Kosuge, T.4    Yamazaki, S.5    Hasegawa, H.6
  • 10
    • 0037775811 scopus 로고    scopus 로고
    • Influence of transfusions on perioperative and long-term outcome in patients following hepatic resection for colorectal metastases
    • Kooby, DA, Stockman, J., Ben-Porat, L., Gonen, M., Jarnagin, WR Dematteo, RP et al. (2003) Influence of transfusions on perioperative and long-term outcome in patients following hepatic resection for colorectal metastases. Ann Surg, 237, pp. 860-869.
    • (2003) Ann Surg , vol.237 , pp. 860-869
    • Kooby, D.A.1    Stockman, J.2    Ben-Porat, L.3    Gonen, M.4    Jarnagin, W.R.5    Dematteo, R.P.6
  • 11
    • 0031445926 scopus 로고    scopus 로고
    • Prospective evaluation of Pringle maneuver in hepatectomy for liver tumors by a randomized study
    • Man, K., Fan, ST, Ng, IO, Lo, CM, Liu, CL and Wong, J. (1997) Prospective evaluation of Pringle maneuver in hepatectomy for liver tumors by a randomized study. Ann Surg, 226, pp. 704-711.
    • (1997) Ann Surg , vol.226 , pp. 704-711
    • Man, K.1    Fan, S.T.2    Ng, I.O.3    Lo, C.M.4    Liu, C.L.5    Wong, J.6
  • 12
    • 0031856599 scopus 로고    scopus 로고
    • Central venous pressure and its effect on blood loss during liver resection
    • Jones, RM, Moulton, CE and Hardy, KJ. (1998) Central venous pressure and its effect on blood loss during liver resection. Br J Surg, 85, pp. 1058-1060.
    • (1998) Br J Surg , vol.85 , pp. 1058-1060
    • Jones, R.M.1    Moulton, C.E.2    Hardy, K.J.3
  • 14
    • 0034904303 scopus 로고    scopus 로고
    • Randomized comparison of ultrasonic vs clamp transection of the liver
    • Takayama, T., Makuuchi, M., Kubota, K., Harihara, Y., Hui, AM Sano, K. et al. (2001) Randomized comparison of ultrasonic vs clamp transection of the liver. Arch Surg, 136, pp. 922-928.
    • (2001) Arch Surg , vol.136 , pp. 922-928
    • Takayama, T.1    Makuuchi, M.2    Kubota, K.3    Harihara, Y.4    Hui, A.M.5    Sano, K.6
  • 15
    • 1542375964 scopus 로고    scopus 로고
    • Bloodless liver resection using the monopolar floating ball plus ligasure diathermy: Preliminary results of 16 liver resections
    • Sakamoto, Y., Yamamoto, J., Kokudo, N., Seki, M., Kosuge, T. Yamaguchi, T. et al. (2004) Bloodless liver resection using the monopolar floating ball plus ligasure diathermy: Preliminary results of 16 liver resections. World J Surg, 28, pp. 166-172.
    • (2004) World J Surg , vol.28 , pp. 166-172
    • Sakamoto, Y.1    Yamamoto, J.2    Kokudo, N.3    Seki, M.4    Kosuge, T.5    Yamaguchi, T.6
  • 16
    • 17744390784 scopus 로고    scopus 로고
    • Hepatic surgery using the Ligasure vessel sealing system
    • Romano, F., Franciosi, C., Caprotti, R. and Uggeri, F. (2005) Hepatic surgery using the Ligasure vessel sealing system. World J Surg, 29, pp. 110-112.
    • (2005) World J Surg , vol.29 , pp. 110-112
    • Romano, F.1    Franciosi, C.2    Caprotti, R.3    Uggeri, F.4
  • 17
    • 0033511442 scopus 로고    scopus 로고
    • Continuous versus intermittent portal triad clamping for liver resection: A controlled study
    • Belghiti, J., Noun, R., Malafosse, R., Jagot, P., Sauvanet, A. Pierangeli, F. et al. (1999) Continuous versus intermittent portal triad clamping for liver resection: A controlled study. Ann Surg, 229, pp. 369-375.
    • (1999) Ann Surg , vol.229 , pp. 369-375
    • Belghiti, J.1    Noun, R.2    Malafosse, R.3    Jagot, P.4    Sauvanet, A.5    Pierangeli, F.6
  • 18
    • 0033185728 scopus 로고    scopus 로고
    • Liver resection using total vascular exclusion, scalpel division of the parenchyma, and a simple compression technique for hemostasis and biliary control
    • Hansen, PD, Isla, AM and Habib, NA. (1999) Liver resection using total vascular exclusion, scalpel division of the parenchyma, and a simple compression technique for hemostasis and biliary control. J Gastrointest Surg, 3, pp. 537-542.
    • (1999) J Gastrointest Surg , vol.3 , pp. 537-542
    • Hansen, P.D.1    Isla, A.M.2    Habib, N.A.3
  • 19
    • 0033506437 scopus 로고    scopus 로고
    • Risk of major liver resection in patients with underlying chronic liver disease: A reappraisal
    • Farges, O., Malassagne, B., Flejou, JF, Balzan, S., Sauvanet, A. and Belghiti, J. (1999) Risk of major liver resection in patients with underlying chronic liver disease: A reappraisal. Ann Surg, 229, pp. 210-215.
    • (1999) Ann Surg , vol.229 , pp. 210-215
    • Farges, O.1    Malassagne, B.2    Flejou, J.F.3    Balzan, S.4    Sauvanet, A.5    Belghiti, J.6
  • 21
    • 26944479618 scopus 로고    scopus 로고
    • Short- and-long term results of intraoperative radiofrequency ablation of liver metastases
    • Navarra, G., Ayav, A., Weber, JC, Jensen, SL, Smadga, C. Nicholls, JP et al. (2005) Short- and-long term results of intraoperative radiofrequency ablation of liver metastases. Int J Colorectal Dis, 20, pp. 521-528.
    • (2005) Int J Colorectal Dis , vol.20 , pp. 521-528
    • Navarra, G.1    Ayav, A.2    Weber, J.C.3    Jensen, S.L.4    Smadga, C.5    Nicholls, J.P.6
  • 22
    • 34547412038 scopus 로고    scopus 로고
    • Bloodless liver resection using radiofrequency energy
    • Ayav, A., Jiao, LR and Habib, NA. (2007) Bloodless liver resection using radiofrequency energy. Dig Surg, 24, pp. 314-317.
    • (2007) Dig Surg , vol.24 , pp. 314-317
    • Ayav, A.1    Jiao, L.R.2    Habib, N.A.3
  • 23
    • 33846272342 scopus 로고    scopus 로고
    • Impact of radiofrequency assisted hepatectomy for reduction of transfusion requirements
    • Ayav, A., Bachellier, P., Habib, NA, Pellicci, R., Tierris, J. Milicevic, M. et al. (2007) Impact of radiofrequency assisted hepatectomy for reduction of transfusion requirements. Am J Surg, 193, pp. 143-148.
    • (2007) Am J Surg , vol.193 , pp. 143-148
    • Ayav, A.1    Bachellier, P.2    Habib, N.A.3    Pellicci, R.4    Tierris, J.5    Milicevic, M.6
  • 24
    • 0842310770 scopus 로고    scopus 로고
    • Liver resection for colorectal metastases: The third hepatectomy
    • Adam, R., Pascal, G., Azoulay, D., Tanaka, K., Castaing, D. and Bismuth, H. (2003) Liver resection for colorectal metastases: The third hepatectomy. Ann Surg, 238, pp. 871-883.
    • (2003) Ann Surg , vol.238 , pp. 871-883
    • Adam, R.1    Pascal, G.2    Azoulay, D.3    Tanaka, K.4    Castaing, D.5    Bismuth, H.6
  • 25
    • 0041919288 scopus 로고    scopus 로고
    • Simultaneous resection of colorectal primary tumour and synchronous liver metastases
    • Weber, JC, Bachellier, P., Oussoultzoglou, E. and Jaeck, D. (2003) Simultaneous resection of colorectal primary tumour and synchronous liver metastases. Br J Surg, 90, pp. 956-962.
    • (2003) Br J Surg , vol.90 , pp. 956-962
    • Weber, J.C.1    Bachellier, P.2    Oussoultzoglou, E.3    Jaeck, D.4
  • 26
    • 6944221579 scopus 로고    scopus 로고
    • Major liver resection without clamping: A prospective reappraisal in the era of modern surgical tools
    • Scatton, O., Massault, PP, Dousset, B., Houssin, D., Bernard, D., Terris, B. and Soubrane, O. (2004) Major liver resection without clamping: A prospective reappraisal in the era of modern surgical tools. J Am Coll Surg, 199, pp. 702-708.
    • (2004) J Am Coll Surg , vol.199 , pp. 702-708
    • Scatton, O.1    Massault, P.P.2    Dousset, B.3    Houssin, D.4    Bernard, D.5    Terris, B.6    Soubrane, O.7
  • 28
    • 0024505106 scopus 로고
    • Vascular occlusions for liver resections. Operative management and tolerance to hepatic ischemia: 142 cases
    • Delva, E., Camus, Y., Nordlinger, B., Hannoun, L., Parc, R. Deriaz, H. et al. (1989) Vascular occlusions for liver resections. Operative management and tolerance to hepatic ischemia: 142 cases. Ann Surg, 209, pp. 211-218.
    • (1989) Ann Surg , vol.209 , pp. 211-218
    • Delva, E.1    Camus, Y.2    Nordlinger, B.3    Hannoun, L.4    Parc, R.5    Deriaz, H.6
  • 29
    • 0028295136 scopus 로고
    • Hepatic resection with ischemia of the liver exceeding one hour
    • Huguet, C., Gavelli, A. and Bona, S. (1994) Hepatic resection with ischemia of the liver exceeding one hour. J Am Coll Surg, 178, pp. 454-458.
    • (1994) J Am Coll Surg , vol.178 , pp. 454-458
    • Huguet, C.1    Gavelli, A.2    Bona, S.3
  • 30
    • 0028861894 scopus 로고
    • Intermittent vascular exclusion of the liver (without vena cava clamping) during major hepatectomy
    • Elias, D., Lasser, P., Debaene, B., Doidy, L., Billard, V., Spencer, A. and Leclercq, B. (1995) Intermittent vascular exclusion of the liver (without vena cava clamping) during major hepatectomy. Br J Surg, 82, pp. 1535-1539.
    • (1995) Br J Surg , vol.82 , pp. 1535-1539
    • Elias, D.1    Lasser, P.2    Debaene, B.3    Doidy, L.4    Billard, V.5    Spencer, A.6    Leclercq, B.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.