메뉴 건너뛰기




Volumn 46, Issue 4-5, 2013, Pages 285-288

A comparison of glucose concentration in paired specimens collected in serum separator and fluoride/potassium oxalate blood collection tubes under survey 'field' conditions

Author keywords

Blood glucose; Fluoride oxalate; Serum separator

Indexed keywords

CATALASE; FLUORIDE; GLUCOSE; GLUCOSE OXIDASE; OXALATE POTASSIUM; POTASSIUM; UNCLASSIFIED DRUG;

EID: 84873731597     PISSN: 00099120     EISSN: 18732933     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2012.11.027     Document Type: Article
Times cited : (29)

References (14)
  • 1
    • 0028284339 scopus 로고
    • Stability of plasma lactate in vitro in the presence of antiglycolytic agents
    • Astles R., Williams C.P., Sedor F. Stability of plasma lactate in vitro in the presence of antiglycolytic agents. Clin Chem 1994, 40:1327-1330.
    • (1994) Clin Chem , vol.40 , pp. 1327-1330
    • Astles, R.1    Williams, C.P.2    Sedor, F.3
  • 4
    • 0034397156 scopus 로고    scopus 로고
    • Effect of specimen collection and storage on blood glucose and lactate concentrations in healthy, hyperthyroid and diabetic cats
    • Christopher M.M., O'Neill S. Effect of specimen collection and storage on blood glucose and lactate concentrations in healthy, hyperthyroid and diabetic cats. Vet Clin Pathol 2000, 29:22-28.
    • (2000) Vet Clin Pathol , vol.29 , pp. 22-28
    • Christopher, M.M.1    O'Neill, S.2
  • 5
    • 39549107177 scopus 로고    scopus 로고
    • Canadian health measures survey: ethical, legal and social issues
    • Day B., Langlois R., Tremblay M., Knoppers B.-M. Canadian health measures survey: ethical, legal and social issues. Health Rep 2007, 18:S37-S51.
    • (2007) Health Rep , vol.18
    • Day, B.1    Langlois, R.2    Tremblay, M.3    Knoppers, B.-M.4
  • 6
    • 84873707478 scopus 로고    scopus 로고
    • Specimen collection and other preanalytical variables
    • Saunders Elsevier, St. Louis, MO, C.A. Burtis, E.R. Ashwood, D.E. Bruns (Eds.)
    • Young D.S., Bermes E.W.J., Haverstick D.M. Specimen collection and other preanalytical variables. Tietz fundamentals of clinical chemistry 2008, 42-49. Saunders Elsevier, St. Louis, MO. 6th ed. C.A. Burtis, E.R. Ashwood, D.E. Bruns (Eds.).
    • (2008) Tietz fundamentals of clinical chemistry , pp. 42-49
    • Young, D.S.1    Bermes, E.W.J.2    Haverstick, D.M.3
  • 7
    • 0003072603 scopus 로고
    • Determination of glucose in blood using glucose oxidase with an alternative oxygen acceptor
    • Trinder P. Determination of glucose in blood using glucose oxidase with an alternative oxygen acceptor. Ann Clin Biochem 1969, 6:24-27.
    • (1969) Ann Clin Biochem , vol.6 , pp. 24-27
    • Trinder, P.1
  • 9
    • 77956179094 scopus 로고    scopus 로고
    • Evaluation of the vitros 5600 integrated system in a pediatric setting and determination of pediatric reference intervals. Clin Biochem ;43:1039-44.
    • Blasutig IM, Jung B, Kulasingam V, Baradaran S, Chen Y, Chan MK, et al. Evaluation of the vitros 5600 integrated system in a pediatric setting and determination of pediatric reference intervals. Clin Biochem 2010;43:1039-44.
    • (2010)
    • Blasutig, I.M.1    Jung, B.2    Kulasingam, V.3    Baradaran, S.4    Chen, Y.5    Chan, M.K.6
  • 10
    • 0016608613 scopus 로고
    • The difference between the glucose concentrations in plasma and whole blood
    • Holtkamp H.C., Verhoef N.J., Leijnse B. The difference between the glucose concentrations in plasma and whole blood. Clin Chim Acta 1975, 59:41-49.
    • (1975) Clin Chim Acta , vol.59 , pp. 41-49
    • Holtkamp, H.C.1    Verhoef, N.J.2    Leijnse, B.3
  • 11
    • 17744384706 scopus 로고    scopus 로고
    • Assessment of a reference procedure to collect and analyze glucose in capillary whole blood
    • Vesper H.W., Archibold E., Porter K.H., Myers G.L. Assessment of a reference procedure to collect and analyze glucose in capillary whole blood. Clin Chem 2005, 51:901-903.
    • (2005) Clin Chem , vol.51 , pp. 901-903
    • Vesper, H.W.1    Archibold, E.2    Porter, K.H.3    Myers, G.L.4
  • 12
    • 0036177713 scopus 로고    scopus 로고
    • Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
    • Sacks D.B., Bruns D.E., Goldstein D.E., Maclaren N.K., McDonald J.M., Parrott M. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 2002, 48:436-472.
    • (2002) Clin Chem , vol.48 , pp. 436-472
    • Sacks, D.B.1    Bruns, D.E.2    Goldstein, D.E.3    Maclaren, N.K.4    McDonald, J.M.5    Parrott, M.6
  • 13
    • 34447319106 scopus 로고    scopus 로고
    • Glycolysis inhibitors negatively bias blood glucose measurements: potential impact on the reported prevalence of diabetes mellitus
    • Waring W.S., Evans L.E., Kirkpatrick C.T. Glycolysis inhibitors negatively bias blood glucose measurements: potential impact on the reported prevalence of diabetes mellitus. J Clin Pathol 2007, 60:820-823.
    • (2007) J Clin Pathol , vol.60 , pp. 820-823
    • Waring, W.S.1    Evans, L.E.2    Kirkpatrick, C.T.3
  • 14
    • 68149166768 scopus 로고    scopus 로고
    • Rapid blood separation is superior to fluoride for preventing in vitro reductions in measured blood glucose concentration
    • Shi R.Z., Seeley E.S., Bowen R., Faix J.D. Rapid blood separation is superior to fluoride for preventing in vitro reductions in measured blood glucose concentration. J Clin Pathol 2009, 62:752-753.
    • (2009) J Clin Pathol , vol.62 , pp. 752-753
    • Shi, R.Z.1    Seeley, E.S.2    Bowen, R.3    Faix, J.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.