메뉴 건너뛰기




Volumn 56, Issue 6, 2014, Pages 596-609

Self-Expanding Prostheses for Transcatheter Aortic Valve Replacement

Author keywords

Aortic stenosis; Aortic valve; Percutaneous; Self expanding; Transcatheter

Indexed keywords

AORTA VALVE STENOSIS; ARTICLE; BLOOD PRESSURE; CLINICAL EFFECTIVENESS; DEVICE APPROVAL; DEVICE SAFETY; DISEASE SEVERITY; EQUIPMENT DESIGN; EVIDENCE BASED MEDICINE; HEART VALVE BIOPROSTHESIS; HIGH RISK PATIENT; HUMAN; MULTICENTER STUDY (TOPIC); PROSTHESIS; RANDOMIZED CONTROLLED TRIAL (TOPIC); SELF EXPANDING PROSTHESIS; SURVIVAL; SUTURELESS AORTIC VALVE; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT OUTCOME; VASCULAR DISEASE;

EID: 84900023543     PISSN: 00330620     EISSN: 18731740     Source Type: Journal    
DOI: 10.1016/j.pcad.2014.03.002     Document Type: Article
Times cited : (12)

References (30)
  • 1
    • 0031051128 scopus 로고    scopus 로고
    • Clinical factors associated with calcific aortic valve disease. Cardiovascular Health Study
    • Stewart B.F. Clinical factors associated with calcific aortic valve disease. Cardiovascular Health Study. J Am Coll Cardiol 1997, 29:630-634.
    • (1997) J Am Coll Cardiol , vol.29 , pp. 630-634
    • Stewart, B.F.1
  • 2
    • 79952183726 scopus 로고    scopus 로고
    • Epidemiology of valvular heart disease in the adult
    • Iung B., Vahanian A. Epidemiology of valvular heart disease in the adult. Nat Rev Cardiol 2011, 8:162-172.
    • (2011) Nat Rev Cardiol , vol.8 , pp. 162-172
    • Iung, B.1    Vahanian, A.2
  • 3
    • 14044262240 scopus 로고    scopus 로고
    • Frequency by decades of unicuspid, bicuspid, and tricuspid aortic valves in adults having isolated aortic valve replacement for aortic stenosis, with or without associated aortic regurgitation
    • Roberts W.C., Ko J.M. Frequency by decades of unicuspid, bicuspid, and tricuspid aortic valves in adults having isolated aortic valve replacement for aortic stenosis, with or without associated aortic regurgitation. Circulation 2005, 111:920-925.
    • (2005) Circulation , vol.111 , pp. 920-925
    • Roberts, W.C.1    Ko, J.M.2
  • 4
    • 34250836735 scopus 로고    scopus 로고
    • ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing Committee to Revise the 1998 guidelines for the management of patients with valvular heart disease) developed in collaboration with the Society of Cardiovascular Anesthesiologists endorsed by the Soc
    • Bonow R.O., Carabello B.A., Chatterjee K., de Leon A.C., Faxon D.P., Freed M.D., et al. ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing Committee to Revise the 1998 guidelines for the management of patients with valvular heart disease) developed in collaboration with the Society of Cardiovascular Anesthesiologists endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons. J Am Coll Cardiol 2006, 48:e1-e148.
    • (2006) J Am Coll Cardiol , vol.48
    • Bonow, R.O.1    Carabello, B.A.2    Chatterjee, K.3    de Leon, A.C.4    Faxon, D.P.5    Freed, M.D.6
  • 5
    • 79952238040 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation decreases the rate of unoperated aortic stenosis
    • Malaisrie S.C., Tuday E., Lapin B., Wang E., Lee R., McGee E.C., et al. Transcatheter aortic valve implantation decreases the rate of unoperated aortic stenosis. Eur J Cardiothorac Surg 2011, 40(1):43-48.
    • (2011) Eur J Cardiothorac Surg , vol.40 , Issue.1 , pp. 43-48
    • Malaisrie, S.C.1    Tuday, E.2    Lapin, B.3    Wang, E.4    Lee, R.5    McGee, E.C.6
  • 6
    • 84874530713 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation with the Edwards SAPIEN versus the Medtronic CoreValve Revalving system devices: a multicenter collaborative study: the PRAGMATIC Plus Initiative (Pooled-RotterdAm-Milano-Toulouse In Collaboration)
    • Chieffo A., Buchanan G.L., Van Mieghem N.M., Tchetche D., Dumonteil N., Latib A., et al. Transcatheter aortic valve implantation with the Edwards SAPIEN versus the Medtronic CoreValve Revalving system devices: a multicenter collaborative study: the PRAGMATIC Plus Initiative (Pooled-RotterdAm-Milano-Toulouse In Collaboration). J Am Coll Cardiol 2013, 61(8):830-836.
    • (2013) J Am Coll Cardiol , vol.61 , Issue.8 , pp. 830-836
    • Chieffo, A.1    Buchanan, G.L.2    Van Mieghem, N.M.3    Tchetche, D.4    Dumonteil, N.5    Latib, A.6
  • 7
    • 84871496661 scopus 로고    scopus 로고
    • Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI)
    • Tzamtzis S., Viquerat J., Yap J., Mullen M.J., Burriesci G. Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). Med Eng Phys 2013, 35(1):125-130.
    • (2013) Med Eng Phys , vol.35 , Issue.1 , pp. 125-130
    • Tzamtzis, S.1    Viquerat, J.2    Yap, J.3    Mullen, M.J.4    Burriesci, G.5
  • 8
    • 84875456141 scopus 로고    scopus 로고
    • Clinical impact of persistent left bundle-branch block after transcatheter aortic valve implantation with CoreValve Revalving System
    • Testa L., Latib A., De Marco F., De Carlo M., Agnifili M., Latini R.A., et al. Clinical impact of persistent left bundle-branch block after transcatheter aortic valve implantation with CoreValve Revalving System. Circulation 2013, 127(12):1300-1307.
    • (2013) Circulation , vol.127 , Issue.12 , pp. 1300-1307
    • Testa, L.1    Latib, A.2    De Marco, F.3    De Carlo, M.4    Agnifili, M.5    Latini, R.A.6
  • 10
    • 79960593630 scopus 로고    scopus 로고
    • Feasibility of transcatheter aortic valve implantation without balloon pre-dilation: a pilot study
    • Grube E., Naber C., Abizaid A., Sousa E., Mendiz O., Lemos P., et al. Feasibility of transcatheter aortic valve implantation without balloon pre-dilation: a pilot study. JACC Cardiovasc Interv 2011, 4:751-757.
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 751-757
    • Grube, E.1    Naber, C.2    Abizaid, A.3    Sousa, E.4    Mendiz, O.5    Lemos, P.6
  • 13
    • 84872165848 scopus 로고    scopus 로고
    • Update on the need for a permanent pacemaker after transcatheter aortic valve implantation using the CoreValve(R) Accutrak system
    • Tchetche D., Modine T., Farah B., Vahdat O., Sudre A., Koussa M., et al. Update on the need for a permanent pacemaker after transcatheter aortic valve implantation using the CoreValve(R) Accutrak system. EuroIntervention 2012, 8:556-562.
    • (2012) EuroIntervention , vol.8 , pp. 556-562
    • Tchetche, D.1    Modine, T.2    Farah, B.3    Vahdat, O.4    Sudre, A.5    Koussa, M.6
  • 14
    • 79953697405 scopus 로고    scopus 로고
    • Transapical aortic valve implantation with a self-expanding anatomically oriented valve
    • Falk V., Walther T., Schwammenthal E., Strauch J., Aicher D., Wahlers T., et al. Transapical aortic valve implantation with a self-expanding anatomically oriented valve. Eur Heart J 2011, 32(7):878-887.
    • (2011) Eur Heart J , vol.32 , Issue.7 , pp. 878-887
    • Falk, V.1    Walther, T.2    Schwammenthal, E.3    Strauch, J.4    Aicher, D.5    Wahlers, T.6
  • 20
    • 84884159400 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement with a new self-expanding transcatheter heart valve and motorized delivery system
    • Binder R.K., Schafer U., Kuck K.H., Wood D.A., Moss R., Leipsic J., et al. Transcatheter aortic valve replacement with a new self-expanding transcatheter heart valve and motorized delivery system. JACC Cardiovasc Interv 2013, 6:301-307.
    • (2013) JACC Cardiovasc Interv , vol.6 , pp. 301-307
    • Binder, R.K.1    Schafer, U.2    Kuck, K.H.3    Wood, D.A.4    Moss, R.5    Leipsic, J.6
  • 23
    • 84876273868 scopus 로고    scopus 로고
    • The SADRA Lotus valve system: a fully repositionable, retrievable prosthesis
    • Gooley R., Lockwood S., Antonis P., Meredith I.T. The SADRA Lotus valve system: a fully repositionable, retrievable prosthesis. Minerva Cardioangiol 2013, 61:45-52.
    • (2013) Minerva Cardioangiol , vol.61 , pp. 45-52
    • Gooley, R.1    Lockwood, S.2    Antonis, P.3    Meredith, I.T.4
  • 24
    • 84900010591 scopus 로고    scopus 로고
    • Feasibility study of the repositionable Lotus aortic valve replacement system: 3-month outcomes in 11 patients at high surgical risk (REPRISE I). Presented at TCT 2012, Miami. Available at:
    • Meredith IT, Worthley SG, Whitbourn RJ, Antonis P, Montarello JK, Newcomb AE, et al. Feasibility study of the repositionable Lotus aortic valve replacement system: 3-month outcomes in 11 patients at high surgical risk (REPRISE I). Presented at TCT 2012, Miami. Available at:. http://www.tctmd.com/show.aspx?id=115120.
    • Meredith, I.T.1    Worthley, S.G.2    Whitbourn, R.J.3    Antonis, P.4    Montarello, J.K.5    Newcomb, A.E.6
  • 25
    • 79960921321 scopus 로고    scopus 로고
    • A new self-expanding transcatheter aortic valve for transapical implantation - first in man implantation of the JenaValve™
    • Kempfert J., Rastan A.J., Mohr F.W., Walther T. A new self-expanding transcatheter aortic valve for transapical implantation - first in man implantation of the JenaValve™. Eur J Cardiothorac Surg 2011, 40(3):761-763.
    • (2011) Eur J Cardiothorac Surg , vol.40 , Issue.3 , pp. 761-763
    • Kempfert, J.1    Rastan, A.J.2    Mohr, F.W.3    Walther, T.4
  • 26
    • 84865348112 scopus 로고    scopus 로고
    • Transapical transcatheter aortic valve implantation using the JenaValve™ system: acute and 30-day results of the multicentre CE-mark study
    • Treede H., Mohr F.W., Baldus S., Rastan A., Ensminger S., Arnold M., et al. Transapical transcatheter aortic valve implantation using the JenaValve™ system: acute and 30-day results of the multicentre CE-mark study. Eur J Cardiothorac Surg 2012, 41:e131-e138.
    • (2012) Eur J Cardiothorac Surg , vol.41
    • Treede, H.1    Mohr, F.W.2    Baldus, S.3    Rastan, A.4    Ensminger, S.5    Arnold, M.6
  • 28
    • 84856935328 scopus 로고    scopus 로고
    • New sutureless aortic valve prosthesis: another tool in less invasive aortic valve replacement
    • Zannis K., Folliguet T., Laborde F. New sutureless aortic valve prosthesis: another tool in less invasive aortic valve replacement. Curr Opin Cardiol 2012, 27:125-129.
    • (2012) Curr Opin Cardiol , vol.27 , pp. 125-129
    • Zannis, K.1    Folliguet, T.2    Laborde, F.3
  • 29
    • 84879696285 scopus 로고    scopus 로고
    • The Perceval S aortic valve has the potential of shortening surgical time: does it also result in improved outcome?
    • Santarpino G., Pfeiffer S., Concistré G., Grossman I., Hinzmann M., Fischlein T. The Perceval S aortic valve has the potential of shortening surgical time: does it also result in improved outcome?. Ann Thorac Surg 2013, 96(1):77-81.
    • (2013) Ann Thorac Surg , vol.96 , Issue.1 , pp. 77-81
    • Santarpino, G.1    Pfeiffer, S.2    Concistré, G.3    Grossman, I.4    Hinzmann, M.5    Fischlein, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.