메뉴 건너뛰기




Volumn 6, Issue 3, 2013, Pages 301-307

Transcatheter aortic valve replacement with a new self-expanding transcatheter heart valve and motorized delivery system

Author keywords

CENTERA; Paravalvular regurgitation; Self expanding transcatheter heart valve; Severe aortic stenosis; Transcatheter aortic valve replacement

Indexed keywords

ACETYLSALICYLIC ACID; CLOPIDOGREL; NITINOL; POLYETHYLENE TEREPHTHALATE;

EID: 84884159400     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2013.01.129     Document Type: Article
Times cited : (35)

References (10)
  • 1
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • Leon MB, Smith CR, Mack M, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010;363:1597-607.
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3
  • 2
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • Smith CR, Leon MB, Mack MJ, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 2011;364:2187-98.
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3
  • 3
    • 78651337155 scopus 로고    scopus 로고
    • Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: A consensus report from the valve academic Research Consortium
    • Leon MB, Piazza N, Nikolsky E, et al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the valve academic Research Consortium. J Am Coll Cardiol 2011;57:253-69.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 253-269
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3
  • 4
    • 10244236377 scopus 로고    scopus 로고
    • Acute renal failure-definition, outcome measures, animal models, fluid therapy and information technology needs: The Second International Consensus Conference of the Acute Dialysis Quality Initiative (ADQI) Group
    • Bellomo R, Ronco C, Kellum JA, Mehta RL, Palevsky P, Acute Dialysis Quality Initiative Workgroup. Acute renal failure-definition, outcome measures, animal models, fluid therapy and information technology needs: the Second International Consensus Conference of the Acute Dialysis Quality Initiative (ADQI) Group. Crit Care 2004;8:R204-12.
    • (2004) Crit Care , vol.8
    • Bellomo, R.1    Ronco, C.2    Kellum, J.A.3    Mehta, R.L.4    Palevsky, P.5
  • 5
    • 84861549775 scopus 로고    scopus 로고
    • Structural integrity of balloon-expandable stents after transcatheter aortic valve replacement: Assessment by multidetector computed tomography
    • Willson AB, Webb JG, Gurvitch R, et al. Structural integrity of balloon-expandable stents after transcatheter aortic valve replacement: assessment by multidetector computed tomography. J Am Coll Cardiol Intv 2012;5:525-32.
    • (2012) J Am Coll Cardiol Intv , vol.5 , pp. 525-532
    • Willson, A.B.1    Webb, J.G.2    Gurvitch, R.3
  • 6
    • 68949174075 scopus 로고    scopus 로고
    • Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis
    • Schultz CJ, Weustink A, Piazza N, et al. Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis. J Am Coll Cardiol 2009;54:911-8.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 911-918
    • Schultz, C.J.1    Weustink, A.2    Piazza, N.3
  • 7
    • 79958019260 scopus 로고    scopus 로고
    • Comparison of complete versus incomplete stent frame expansion after transcatheter aortic valve implantation with Medtronic CoreValve bioprosthesis
    • Jilaihawi H, Chin D, Spyt T, et al. Comparison of complete versus incomplete stent frame expansion after transcatheter aortic valve implantation with Medtronic CoreValve bioprosthesis. Am J Cardiol 2011;107:1830-7.
    • (2011) Am J Cardiol , vol.107 , pp. 1830-1837
    • Jilaihawi, H.1    Chin, D.2    Spyt, T.3
  • 8
    • 84864707358 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement with the St. Jude Medical portico valve: First-inhuman experience
    • Willson AB, Rodès-Cabau J, Wood DA, et al. Transcatheter aortic valve replacement with the St. Jude Medical portico valve: first-inhuman experience. J Am Coll Cardiol 2012;60:581-6.
    • (2012) J Am Coll Cardiol , vol.60 , pp. 581-586
    • Willson, A.B.1    Rodès-Cabau, J.2    Wood, D.A.3
  • 9
    • 83855164082 scopus 로고    scopus 로고
    • Transcatheter heart valve with variable geometric configuration: In vitro evaluation
    • Young E, Chen JF, Dong O, Gao S, Massiello A, Fukamachi K. Transcatheter heart valve with variable geometric configuration: in vitro evaluation. Artif Organs 2011;35:1151-9.
    • (2011) Artif Organs , vol.35 , pp. 1151-1159
    • Young, E.1    Chen, J.F.2    Dong, O.3    Gao, S.4    Massiello, A.5    Fukamachi, K.6
  • 10
    • 84860436228 scopus 로고    scopus 로고
    • Registry of transcatheter aortic-valve implantation in high-risk patients
    • Gilard M, Eltchaninoff H, Iung B, et al. Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med 2012;366:1705-15.
    • (2012) N Engl J Med , vol.366 , pp. 1705-1715
    • Gilard, M.1    Eltchaninoff, H.2    Iung, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.