메뉴 건너뛰기




Volumn 35, Issue 22, 2014, Pages 5647-5659

A polycaprolactone-tricalcium phosphate composite scaffold as an autograft-free spinal fusion cage in a sheep model

Author keywords

Biodegradable; Fusion cage; Polycaprolactone; Ti6Al4V; Tricalcium phosphate

Indexed keywords

BIODEGRADATION; BONE; COMPUTERIZED TOMOGRAPHY; POLYMETHYL METHACRYLATES; SCAFFOLDS (BIOLOGY); TISSUE;

EID: 84899934890     PISSN: 01429612     EISSN: 18785905     Source Type: Journal    
DOI: 10.1016/j.biomaterials.2014.03.075     Document Type: Article
Times cited : (75)

References (48)
  • 2
    • 33846066293 scopus 로고    scopus 로고
    • Decision making process: problem based decision making
    • Shedid D., Benzel E.C. Decision making process: problem based decision making. Neurosurgery 2007, 60:S166-S169.
    • (2007) Neurosurgery , vol.60
    • Shedid, D.1    Benzel, E.C.2
  • 3
    • 57349111434 scopus 로고
    • History of spinal fusion
    • Springer, New York, M. Jerome, B. Howard (Eds.)
    • Peek Richard D., Wiltse Leon L. History of spinal fusion. Spinal fusion 1990, p.3-p.8. Springer, New York. M. Jerome, B. Howard (Eds.).
    • (1990) Spinal fusion
    • Peek, R.D.1    Wiltse, L.L.2
  • 4
    • 0024435832 scopus 로고
    • Comparison of disc space heights after anterior lumbar interbody fusion
    • Dennis S., Watkins R., Landaker S., Dillin W., Springer D. Comparison of disc space heights after anterior lumbar interbody fusion. Spine 1989, 14:876-878.
    • (1989) Spine , vol.14 , pp. 876-878
    • Dennis, S.1    Watkins, R.2    Landaker, S.3    Dillin, W.4    Springer, D.5
  • 5
    • 0024542557 scopus 로고
    • Posterior lumbar interbody fusion with facet-screw fixation
    • Stonecipher T., Wright S. Posterior lumbar interbody fusion with facet-screw fixation. Spine 1989, 14:468-471.
    • (1989) Spine , vol.14 , pp. 468-471
    • Stonecipher, T.1    Wright, S.2
  • 6
    • 0348223825 scopus 로고    scopus 로고
    • Lumbar intervertebral body fusion cages: histological evaluation of clinically failed cages retrieved from humans
    • Togawa D., Bauer T.W., Lieberman I.H., Sakai H. Lumbar intervertebral body fusion cages: histological evaluation of clinically failed cages retrieved from humans. JBone Jt Surg Am 2004, 86:70-79.
    • (2004) JBone Jt Surg Am , vol.86 , pp. 70-79
    • Togawa, D.1    Bauer, T.W.2    Lieberman, I.H.3    Sakai, H.4
  • 7
    • 0024452327 scopus 로고
    • 1989 Volvo Award in basic science. Device-related osteoporosis with spinal instrumentation
    • McAfee P.C., Farey I.D., Sutterlin C.E., Gurr K.R., Warden K.E., Cunningham B.W. 1989 Volvo Award in basic science. Device-related osteoporosis with spinal instrumentation. Spine 1989, 14:919-926.
    • (1989) Spine , vol.14 , pp. 919-926
    • McAfee, P.C.1    Farey, I.D.2    Sutterlin, C.E.3    Gurr, K.R.4    Warden, K.E.5    Cunningham, B.W.6
  • 8
    • 0036534292 scopus 로고    scopus 로고
    • The effect of cage stiffness on the rate of lumbar interbody fusion: an invivo model using poly(l-lactic Acid) and titanium cages
    • Van Dijk M., Smit T.H., Sugihara S., Burger E.H., Wuisman P.I. The effect of cage stiffness on the rate of lumbar interbody fusion: an invivo model using poly(l-lactic Acid) and titanium cages. Spine 2002, 27:682-688.
    • (2002) Spine , vol.27 , pp. 682-688
    • Van Dijk, M.1    Smit, T.H.2    Sugihara, S.3    Burger, E.H.4    Wuisman, P.I.5
  • 9
    • 0028600649 scopus 로고
    • Complications after transpedicular stabilization of the spine. A survivorship analysis of 163 cases
    • Ohlin A., Karlsson M., Duppe H., Hasserius R., Redlund-Johnell I. Complications after transpedicular stabilization of the spine. A survivorship analysis of 163 cases. Spine 1994, 19:2774-2779.
    • (1994) Spine , vol.19 , pp. 2774-2779
    • Ohlin, A.1    Karlsson, M.2    Duppe, H.3    Hasserius, R.4    Redlund-Johnell, I.5
  • 10
    • 0034318923 scopus 로고    scopus 로고
    • Subsidence resulting from simulated postoperative neck movements: an invitro investigation with a new cervical fusion cage
    • Wilke H.J., Kettler A., Goetz C., Claes L. Subsidence resulting from simulated postoperative neck movements: an invitro investigation with a new cervical fusion cage. Spine 2000, 25:2762-2770.
    • (2000) Spine , vol.25 , pp. 2762-2770
    • Wilke, H.J.1    Kettler, A.2    Goetz, C.3    Claes, L.4
  • 11
    • 0034672872 scopus 로고    scopus 로고
    • Scaffolds in tissue engineering bone and cartilage
    • Hutmacher D.W. Scaffolds in tissue engineering bone and cartilage. Biomaterials 2000, 21:2529-2543.
    • (2000) Biomaterials , vol.21 , pp. 2529-2543
    • Hutmacher, D.W.1
  • 12
    • 0035094757 scopus 로고    scopus 로고
    • Mechanical properties and cell cultural response of polycaprolactone scaffolds designed and fabricated via fused deposition modeling
    • Hutmacher D.W., Schantz T., Zein I., Ng K.W., Teoh S.H., Tan K.C. Mechanical properties and cell cultural response of polycaprolactone scaffolds designed and fabricated via fused deposition modeling. JBiomed Mater Res 2001, 55:203-216.
    • (2001) JBiomed Mater Res , vol.55 , pp. 203-216
    • Hutmacher, D.W.1    Schantz, T.2    Zein, I.3    Ng, K.W.4    Teoh, S.H.5    Tan, K.C.6
  • 13
    • 0037082740 scopus 로고    scopus 로고
    • Fused deposition modeling of novel scaffold architectures for tissue engineering applications
    • Zein I., Hutmacher D.W., Tan K.C., Teoh S.H. Fused deposition modeling of novel scaffold architectures for tissue engineering applications. Biomaterials 2002, 23:1169-1185.
    • (2002) Biomaterials , vol.23 , pp. 1169-1185
    • Zein, I.1    Hutmacher, D.W.2    Tan, K.C.3    Teoh, S.H.4
  • 14
    • 0042861475 scopus 로고    scopus 로고
    • Osteogenic induction of human bone marrow-derived mesenchymal progenitor cells in novel synthetic polymer-hydrogel matrices
    • Endres M., Hutmacher D.W., Salgado A.J., Kaps C., Ringe J., Reis R.L., et al. Osteogenic induction of human bone marrow-derived mesenchymal progenitor cells in novel synthetic polymer-hydrogel matrices. Tissue Eng 2003, 9:689-702.
    • (2003) Tissue Eng , vol.9 , pp. 689-702
    • Endres, M.1    Hutmacher, D.W.2    Salgado, A.J.3    Kaps, C.4    Ringe, J.5    Reis, R.L.6
  • 15
    • 84867097728 scopus 로고    scopus 로고
    • Biocompatibility and biodegradation studies of PCL/β-TCP bone tissue scaffold fabricated by structural porogen method
    • Lu L., Zhang Q., Wootton D., Chiou R., Li D., Lu B., et al. Biocompatibility and biodegradation studies of PCL/β-TCP bone tissue scaffold fabricated by structural porogen method. JMater Sci Mater Med 2012, 23:2217-2226.
    • (2012) JMater Sci Mater Med , vol.23 , pp. 2217-2226
    • Lu, L.1    Zhang, Q.2    Wootton, D.3    Chiou, R.4    Li, D.5    Lu, B.6
  • 16
    • 84855918446 scopus 로고    scopus 로고
    • The potential of human fetal mesenchymal stem cells for off-the-shelf bone tissue engineering application
    • Zhang Z.Y., Teoh S.H., Hui J.H., Fisk N.M., Choolani M., Chan J.K. The potential of human fetal mesenchymal stem cells for off-the-shelf bone tissue engineering application. Biomaterials 2012, 33:2656-2672.
    • (2012) Biomaterials , vol.33 , pp. 2656-2672
    • Zhang, Z.Y.1    Teoh, S.H.2    Hui, J.H.3    Fisk, N.M.4    Choolani, M.5    Chan, J.K.6
  • 17
    • 75549083844 scopus 로고    scopus 로고
    • Neo-vascularization and bone formation mediated by fetal mesenchymal stem cell tissue-engineered bone grafts in critical-size femoral defects
    • Zhang Z.Y., Teoh S.H., Chong M.S., Lee E.S., Tan L.G., Mattar C.N., et al. Neo-vascularization and bone formation mediated by fetal mesenchymal stem cell tissue-engineered bone grafts in critical-size femoral defects. Biomaterials 2010, 31:608-620.
    • (2010) Biomaterials , vol.31 , pp. 608-620
    • Zhang, Z.Y.1    Teoh, S.H.2    Chong, M.S.3    Lee, E.S.4    Tan, L.G.5    Mattar, C.N.6
  • 18
    • 77956033433 scopus 로고    scopus 로고
    • Bioinspired fabrication of 3D hierarchical porous nanomicrostructures of calcium carbonate for bone regeneration
    • Yu H.D., Zhang Z.Y., Win K.Y., Chan J., Teoh S.H., Han M.Y. Bioinspired fabrication of 3D hierarchical porous nanomicrostructures of calcium carbonate for bone regeneration. Chem Commun 2010, 46:6578-6580.
    • (2010) Chem Commun , vol.46 , pp. 6578-6580
    • Yu, H.D.1    Zhang, Z.Y.2    Win, K.Y.3    Chan, J.4    Teoh, S.H.5    Han, M.Y.6
  • 19
    • 77957293934 scopus 로고    scopus 로고
    • Acomparison of bioreactors for culture of fetal mesenchymal stem cells for bone tissue engineering
    • Zhang Z.Y., Teoh S.H., Teo E.Y., Khoon Chong M.S., Shin C.W., Tien F.T., et al. Acomparison of bioreactors for culture of fetal mesenchymal stem cells for bone tissue engineering. Biomaterials 2010, 31:8684-8695.
    • (2010) Biomaterials , vol.31 , pp. 8684-8695
    • Zhang, Z.Y.1    Teoh, S.H.2    Teo, E.Y.3    Khoon Chong, M.S.4    Shin, C.W.5    Tien, F.T.6
  • 20
    • 84870255219 scopus 로고    scopus 로고
    • Lateral ridge augmentation using a PCL-TCP scaffold in a clinically relevant but challenging micropig model
    • Yeo A., Cheok C., Teoh S.H., Zhang Z.Y., Buser D., Bosshardt D.D. Lateral ridge augmentation using a PCL-TCP scaffold in a clinically relevant but challenging micropig model. Clin Oral Implants Res 2012, 23:1322-1332.
    • (2012) Clin Oral Implants Res , vol.23 , pp. 1322-1332
    • Yeo, A.1    Cheok, C.2    Teoh, S.H.3    Zhang, Z.Y.4    Buser, D.5    Bosshardt, D.D.6
  • 22
    • 0031924426 scopus 로고    scopus 로고
    • Testing criteria for spinal implants: recommendations for the standardization of invitro stability testing of spinal implants
    • Wilke H.J., Wenger K., Claes L. Testing criteria for spinal implants: recommendations for the standardization of invitro stability testing of spinal implants. Eur Spine J 1998, 7:148-154.
    • (1998) Eur Spine J , vol.7 , pp. 148-154
    • Wilke, H.J.1    Wenger, K.2    Claes, L.3
  • 23
    • 0032610090 scopus 로고    scopus 로고
    • Histomorphometric evaluation of the effect of hyperbaric oxygen treatment on healing around hydroxyapatite implants in irradiated rat bone
    • Chen X., Matsui Y., Ohno K., Michi K. Histomorphometric evaluation of the effect of hyperbaric oxygen treatment on healing around hydroxyapatite implants in irradiated rat bone. Int J Oral Maxillofac Implants 1999, 14:61-68.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 61-68
    • Chen, X.1    Matsui, Y.2    Ohno, K.3    Michi, K.4
  • 24
    • 0036829097 scopus 로고    scopus 로고
    • Evaluation of 70/30 poly (L-lactide-co-D,L-lactide) for use as a resorbable interbody fusion cage
    • Toth J.M., Estes B.T., Wang M., Seim H.B., Scifert J.L., Turner A.S., et al. Evaluation of 70/30 poly (L-lactide-co-D,L-lactide) for use as a resorbable interbody fusion cage. JNeurosurg 2002, 97:423-432.
    • (2002) JNeurosurg , vol.97 , pp. 423-432
    • Toth, J.M.1    Estes, B.T.2    Wang, M.3    Seim, H.B.4    Scifert, J.L.5    Turner, A.S.6
  • 25
    • 0038206641 scopus 로고    scopus 로고
    • Titanium cage reconstruction after cervical corpectomy
    • Dorai Z., Morgan H., Coimbra C. Titanium cage reconstruction after cervical corpectomy. JNeurosurg 2003, 99:3-7.
    • (2003) JNeurosurg , vol.99 , pp. 3-7
    • Dorai, Z.1    Morgan, H.2    Coimbra, C.3
  • 26
    • 67349195496 scopus 로고    scopus 로고
    • Long term outcome and adjacent disc degeneration after anterior cervical discectomy and fusion with titanium cylindrical cages
    • Sugawara T., Itoh Y., Hirano Y., Higashiyama N., Mizoi K. Long term outcome and adjacent disc degeneration after anterior cervical discectomy and fusion with titanium cylindrical cages. Acta Neurochir 2009, 151:303-309.
    • (2009) Acta Neurochir , vol.151 , pp. 303-309
    • Sugawara, T.1    Itoh, Y.2    Hirano, Y.3    Higashiyama, N.4    Mizoi, K.5
  • 27
    • 0000175297 scopus 로고
    • Mechanical properties of cortical and trabecular bone
    • CRC Press, Boca Raton, FL, B.K. Hall (Ed.)
    • Keaveny T.M., Hayes W.C. Mechanical properties of cortical and trabecular bone. Bone growth 1993, 285-344. CRC Press, Boca Raton, FL. B.K. Hall (Ed.).
    • (1993) Bone growth , pp. 285-344
    • Keaveny, T.M.1    Hayes, W.C.2
  • 28
    • 0034432931 scopus 로고    scopus 로고
    • Invitro biomechanical investigation of the stability and stress-shielding effect of lumbar interbody fusion devices
    • Kanayama M., Cunningham B.W., Haggerty C.J., Abumi K., Kaneda K., McAfee P.C. Invitro biomechanical investigation of the stability and stress-shielding effect of lumbar interbody fusion devices. JNeurosurg 2000, 93:259-265.
    • (2000) JNeurosurg , vol.93 , pp. 259-265
    • Kanayama, M.1    Cunningham, B.W.2    Haggerty, C.J.3    Abumi, K.4    Kaneda, K.5    McAfee, P.C.6
  • 29
    • 18244377399 scopus 로고    scopus 로고
    • Stress shielding in box and Cylinder cervical interbody fusion cage designs
    • Epari D.R., Kandziora F., Duda G.N. Stress shielding in box and Cylinder cervical interbody fusion cage designs. Spine 2005, 30:908-914.
    • (2005) Spine , vol.30 , pp. 908-914
    • Epari, D.R.1    Kandziora, F.2    Duda, G.N.3
  • 30
    • 84879417406 scopus 로고    scopus 로고
    • Review: development of clinically relevant scaffolds for vascularised bone tissue engineering
    • Liu Y., Lim J., Teoh S.H. Review: development of clinically relevant scaffolds for vascularised bone tissue engineering. Biotechnol Adv 2013, 31:688-705.
    • (2013) Biotechnol Adv , vol.31 , pp. 688-705
    • Liu, Y.1    Lim, J.2    Teoh, S.H.3
  • 31
    • 0030898722 scopus 로고    scopus 로고
    • Posterolateral lumbar fusion using facet joint fixation with biodegradable rods: a pilot study
    • Johnsson R., Axelsson P., Stromqvist B. Posterolateral lumbar fusion using facet joint fixation with biodegradable rods: a pilot study. Eur Spine J 1997, 6:144-148.
    • (1997) Eur Spine J , vol.6 , pp. 144-148
    • Johnsson, R.1    Axelsson, P.2    Stromqvist, B.3
  • 32
    • 10044242633 scopus 로고    scopus 로고
    • Abiomechanical and histological evaluation of a bioresorbable lumbar interbody fusion cage
    • Hojo Y., Kotani Y., Ito M., Abumi K., Kadosawa T., Shikinami Y., et al. Abiomechanical and histological evaluation of a bioresorbable lumbar interbody fusion cage. Biomaterials 2005, 26:2643-2651.
    • (2005) Biomaterials , vol.26 , pp. 2643-2651
    • Hojo, Y.1    Kotani, Y.2    Ito, M.3    Abumi, K.4    Kadosawa, T.5    Shikinami, Y.6
  • 33
    • 77956413094 scopus 로고    scopus 로고
    • Increased incidence of cage migration and nonunion in instrumented transforaminal lumbar interbody fusion with bioabsorbable cages
    • Smith A.J., Arginteanu M., Moore F., Steinberger A., Camins M. Increased incidence of cage migration and nonunion in instrumented transforaminal lumbar interbody fusion with bioabsorbable cages. JNeurosurg Spine 2010, 13:388-393.
    • (2010) JNeurosurg Spine , vol.13 , pp. 388-393
    • Smith, A.J.1    Arginteanu, M.2    Moore, F.3    Steinberger, A.4    Camins, M.5
  • 34
    • 33751106162 scopus 로고    scopus 로고
    • High rate of fusion in sheep cervical spines following anterior interbody surgery with absorbable and nonabsorbable implant devices
    • Slivka M.A., Spenciner D.B., Seim H.B., Welch W.C., Serhan H.A., Turner A.S. High rate of fusion in sheep cervical spines following anterior interbody surgery with absorbable and nonabsorbable implant devices. Spine 2006, 31:2772-2777.
    • (2006) Spine , vol.31 , pp. 2772-2777
    • Slivka, M.A.1    Spenciner, D.B.2    Seim, H.B.3    Welch, W.C.4    Serhan, H.A.5    Turner, A.S.6
  • 35
    • 33645048705 scopus 로고    scopus 로고
    • Bioresorbable polymers: heading for a new generation of spinal cages
    • Wuisman P.I., Smit T.H. Bioresorbable polymers: heading for a new generation of spinal cages. Eur Spine J 2006, 15:133-148.
    • (2006) Eur Spine J , vol.15 , pp. 133-148
    • Wuisman, P.I.1    Smit, T.H.2
  • 36
    • 0035288519 scopus 로고    scopus 로고
    • An introduction to biodegradable materials for tissue engineering applications
    • Hutmacher D.W., Goh J.C., Teoh S.H. An introduction to biodegradable materials for tissue engineering applications. Ann Acad Med Singap 2001, 30:183-191.
    • (2001) Ann Acad Med Singap , vol.30 , pp. 183-191
    • Hutmacher, D.W.1    Goh, J.C.2    Teoh, S.H.3
  • 37
    • 0037409874 scopus 로고    scopus 로고
    • Novel bioactive materials with different mechanical properties
    • Kokubo T., Kim H.M., Kawashita M. Novel bioactive materials with different mechanical properties. Biomaterials 2003, 24:2161-2175.
    • (2003) Biomaterials , vol.24 , pp. 2161-2175
    • Kokubo, T.1    Kim, H.M.2    Kawashita, M.3
  • 38
    • 0029868090 scopus 로고    scopus 로고
    • Lateral ridge augmentation using autografts and barrier membranes: a clinical study with 40 partially edentulous patients
    • Buser D., Dula K., Hirt H.P., Schenk R.K. Lateral ridge augmentation using autografts and barrier membranes: a clinical study with 40 partially edentulous patients. JOral Maxillofac Surg 1996, 54:420-432.
    • (1996) JOral Maxillofac Surg , vol.54 , pp. 420-432
    • Buser, D.1    Dula, K.2    Hirt, H.P.3    Schenk, R.K.4
  • 39
    • 0033071915 scopus 로고    scopus 로고
    • Localized ridge augmentation with autografts and barrier membranes
    • Buser D., Dula K., Hess D., Hirt H.P., Belser U.C. Localized ridge augmentation with autografts and barrier membranes. Periodontol 2000, 1999(19):151-163.
    • (2000) Periodontol , vol.1999 , Issue.19 , pp. 151-163
    • Buser, D.1    Dula, K.2    Hess, D.3    Hirt, H.P.4    Belser, U.C.5
  • 40
    • 33746374986 scopus 로고    scopus 로고
    • Horizontal ridge augmentation using autogenous block grafts and the guided bone regeneration technique with collagen membranes: a clinical study with 42 patients
    • Von Arx T., Buser D. Horizontal ridge augmentation using autogenous block grafts and the guided bone regeneration technique with collagen membranes: a clinical study with 42 patients. Clin Oral Implants Res 2006, 17:359-366.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 359-366
    • Von Arx, T.1    Buser, D.2
  • 42
    • 33846811209 scopus 로고    scopus 로고
    • Invitro degradation of novel bioactive polycaprolactone 20% tricalcium phosphate composite scaffolds for bone engineering
    • Lei Y., Rai B., Ho K.H., Teoh S.H. Invitro degradation of novel bioactive polycaprolactone 20% tricalcium phosphate composite scaffolds for bone engineering. Mater Sci Eng C 2007, 27:293-298.
    • (2007) Mater Sci Eng C , vol.27 , pp. 293-298
    • Lei, Y.1    Rai, B.2    Ho, K.H.3    Teoh, S.H.4
  • 43
    • 2342499807 scopus 로고    scopus 로고
    • The effect of rhBMP-2 on canine osteoblasts seeded onto 3D bioactive polycaprolactone scaffolds
    • Rai B., Teoh S.H., Ho K.H., Hutmacher D.W., Cao T., Chen F., et al. The effect of rhBMP-2 on canine osteoblasts seeded onto 3D bioactive polycaprolactone scaffolds. Biomaterials 2004, 25:5499-5506.
    • (2004) Biomaterials , vol.25 , pp. 5499-5506
    • Rai, B.1    Teoh, S.H.2    Ho, K.H.3    Hutmacher, D.W.4    Cao, T.5    Chen, F.6
  • 44
    • 28744438866 scopus 로고    scopus 로고
    • The invivo degradation, absorption and excretion of PCL-based implant
    • Sun H., Mei L., Song C., Cui X., Wang P. The invivo degradation, absorption and excretion of PCL-based implant. Biomaterials 2006 Mar, 27:1735-1740.
    • (2006) Biomaterials , vol.27 , pp. 1735-1740
    • Sun, H.1    Mei, L.2    Song, C.3    Cui, X.4    Wang, P.5
  • 45
    • 80053363820 scopus 로고    scopus 로고
    • Fusion performance of Low Dose rhBMP-2 and BMSCs in biodegradable scaffolds: a Comparative study in a large animal model of anterior lumbar interbody fusion
    • Abbah S.A., Lam C.X., Ramruttun A.K., Goh J.C., Wong H.K. Fusion performance of Low Dose rhBMP-2 and BMSCs in biodegradable scaffolds: a Comparative study in a large animal model of anterior lumbar interbody fusion. Spine 2011, 36:1752-1759.
    • (2011) Spine , vol.36 , pp. 1752-1759
    • Abbah, S.A.1    Lam, C.X.2    Ramruttun, A.K.3    Goh, J.C.4    Wong, H.K.5
  • 46
    • 0035336741 scopus 로고    scopus 로고
    • Comparison between sheep and human cervical spines: an anatomic, radiographic, bone mineral density, and biomechanical study
    • Kandziora F., Pflugmacher R., Scholz M., Schnake K., Lucke M., Schröder R., et al. Comparison between sheep and human cervical spines: an anatomic, radiographic, bone mineral density, and biomechanical study. Spine 2001, 26:1028-1037.
    • (2001) Spine , vol.26 , pp. 1028-1037
    • Kandziora, F.1    Pflugmacher, R.2    Scholz, M.3    Schnake, K.4    Lucke, M.5    Schröder, R.6
  • 47
    • 0031284671 scopus 로고    scopus 로고
    • Are sheep spines a valid biomechanical model for human spines?
    • Wilke H.J., Kettler A., Claes L.E. Are sheep spines a valid biomechanical model for human spines?. Spine 1997, 22:2365-2374.
    • (1997) Spine , vol.22 , pp. 2365-2374
    • Wilke, H.J.1    Kettler, A.2    Claes, L.E.3
  • 48
    • 75049085255 scopus 로고    scopus 로고
    • Anatomy of large animal spines and its comparison to the human spine: a systematic review
    • Sheng S.R., Wang X.Y., Xu H.Z., Zhu G.Q., Zhou Y.F. Anatomy of large animal spines and its comparison to the human spine: a systematic review. Eur Spine J 2010, 19:46-56.
    • (2010) Eur Spine J , vol.19 , pp. 46-56
    • Sheng, S.R.1    Wang, X.Y.2    Xu, H.Z.3    Zhu, G.Q.4    Zhou, Y.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.