메뉴 건너뛰기




Volumn 194, Issue , 2014, Pages 1-6

Amperometric urea biosensor based on covalently immobilized urease on an electrochemically polymerized film of polyaniline containing MWCNTs

Author keywords

Amperometry; Electrochemical biosensor; Enzyme; MWCNTs; Polyaniline; Urea

Indexed keywords

ELECTROCHEMICAL ELECTRODES; ELECTROPOLYMERIZATION; ENZYME IMMOBILIZATION; ENZYMES; METABOLISM; MULTIWALLED CARBON NANOTUBES (MWCN); OPTIMIZATION; POLYANILINE; UREA;

EID: 84899796395     PISSN: 03796779     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.synthmet.2014.04.009     Document Type: Article
Times cited : (51)

References (27)
  • 1
    • 33847412681 scopus 로고    scopus 로고
    • Potentiometric bioelectronic tongue for the analysis of urea and alkaline ions in clinical samples
    • M. Gutierrez, S. Alegret, and M. Valle Potentiometric bioelectronic tongue for the analysis of urea and alkaline ions in clinical samples Biosens. Bioelectron. 22 2007 2171 2178
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 2171-2178
    • Gutierrez, M.1    Alegret, S.2    Valle, M.3
  • 2
    • 2442453337 scopus 로고    scopus 로고
    • Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films
    • B. Lakard, G. Herlem, S. Lakard, A. Antoniou, and B. Fahys Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films Biosens. Bioelectron. 19 2004 1641 1647
    • (2004) Biosens. Bioelectron. , vol.19 , pp. 1641-1647
    • Lakard, B.1    Herlem, G.2    Lakard, S.3    Antoniou, A.4    Fahys, B.5
  • 3
    • 0036284830 scopus 로고    scopus 로고
    • Analytical methodology for the determination of urea current practice and future trends
    • P.S. Francis, S.W. Lewis, and K.F. Lim Analytical methodology for the determination of urea current practice and future trends Trends Anal. Chem. 21 2002 389 400
    • (2002) Trends Anal. Chem. , vol.21 , pp. 389-400
    • Francis, P.S.1    Lewis, S.W.2    Lim, K.F.3
  • 4
    • 79956190942 scopus 로고    scopus 로고
    • Detection of urea in milk by spectrophotometry to p- dimethylaminobenzaldehyde as chromogenic reagent
    • Z.Y. Fan, H.C. Liu, and C. Zhu Detection of urea in milk by spectrophotometry to p-dimethylaminobenzaldehyde as chromogenic reagent Chin. J. Anal. Lab. 28 Suppl. 2009 313 315
    • (2009) Chin. J. Anal. Lab. , vol.28 , Issue.SUPPL. , pp. 313-315
    • Fan, Z.Y.1    Liu, H.C.2    Zhu, C.3
  • 5
    • 0030755967 scopus 로고    scopus 로고
    • Analytical methods for measuring urea in pharmaceutical formulations
    • M.T. Knorst, R. Neubert, and W. Wohlrab Analytical methods for measuring urea in pharmaceutical formulations J. Pharm. Biomed. Anal. 15 11 1997 1627 1632
    • (1997) J. Pharm. Biomed. Anal. , vol.15 , Issue.11 , pp. 1627-1632
    • Knorst, M.T.1    Neubert, R.2    Wohlrab, W.3
  • 6
    • 53349146811 scopus 로고    scopus 로고
    • Voltammetric detection of urea on an Ag-modified zeolite-expanded graphite-epoxy composite electrode
    • F. Manea, A. Pop, C. Radovan, P. Malchev, A. Bebeselea, G. Burtica, S. Picken, and J. Schoonman Voltammetric detection of urea on an Ag-modified zeolite-expanded graphite-epoxy composite electrode Sensors 8 2008 5806 5819
    • (2008) Sensors , vol.8 , pp. 5806-5819
    • Manea, F.1    Pop, A.2    Radovan, C.3    Malchev, P.4    Bebeselea, A.5    Burtica, G.6    Picken, S.7    Schoonman, J.8
  • 7
    • 62649117696 scopus 로고    scopus 로고
    • Ionic effect investigation of a potentiometric sensor for urea and surface morphology observation of entrapped urease/polypyrrole matrix
    • M.J. Syu, and Y.S. Chang Ionic effect investigation of a potentiometric sensor for urea and surface morphology observation of entrapped urease/polypyrrole matrix Biosen. Bioelectron. 24 2009 2671 2677
    • (2009) Biosen. Bioelectron. , vol.24 , pp. 2671-2677
    • Syu, M.J.1    Chang, Y.S.2
  • 8
    • 0029020595 scopus 로고
    • Clinical analysis of urea in human blood by coupling a surface acoustic wave sensor with urease extracted from pumpkin seeds
    • D. Liu, K. Ge, K. Cheng, L. Nie, and S. Yao Clinical analysis of urea in human blood by coupling a surface acoustic wave sensor with urease extracted from pumpkin seeds Anal. Chim. Acta 307 1995 61
    • (1995) Anal. Chim. Acta , vol.307 , pp. 61
    • Liu, D.1    Ge, K.2    Cheng, K.3    Nie, L.4    Yao, S.5
  • 9
    • 0027402740 scopus 로고
    • Potentiometric ion and bioselective electrodes based on asymmetric polyurethane membranes
    • D. Liu, M.E. Meyerhoff, H.D. Goldberg, and R.B. Brown Potentiometric ion and bioselective electrodes based on asymmetric polyurethane membranes Anal. Chim. Acta 274 1993 37
    • (1993) Anal. Chim. Acta , vol.274 , pp. 37
    • Liu, D.1    Meyerhoff, M.E.2    Goldberg, H.D.3    Brown, R.B.4
  • 11
    • 0000900237 scopus 로고
    • Coulometric flow analyzer for use with immobilized enzyme reactors
    • R.E. Adams, and P.W. Carr Coulometric flow analyzer for use with immobilized enzyme reactors Anal. Chem. 50 1978 944
    • (1978) Anal. Chem. , vol.50 , pp. 944
    • Adams, R.E.1    Carr, P.W.2
  • 12
    • 0029939109 scopus 로고    scopus 로고
    • Polypyrrole-based amperometric flow injection biosensor for urea
    • S.B. Adeloju, S.J. Shaw, and G.G. Wallace Polypyrrole-based amperometric flow injection biosensor for urea Anal. Chim. Acta 323 1996 107
    • (1996) Anal. Chim. Acta , vol.323 , pp. 107
    • Adeloju, S.B.1    Shaw, S.J.2    Wallace, G.G.3
  • 13
    • 0000110560 scopus 로고    scopus 로고
    • Electrochemical sensor for measurement of urea and creatinine in serum based on ac impedance measurement of enzyme-catalyzed polymer transformation
    • W.O. Ho, S. Krause, C.J. McNeil, J.A. Pritchard, R.D. Armstrong, and D. Athey et al. Electrochemical sensor for measurement of urea and creatinine in serum based on ac impedance measurement of enzyme-catalyzed polymer transformation Anal. Chem. 71 1999 1940
    • (1999) Anal. Chem. , vol.71 , pp. 1940
    • Ho, W.O.1    Krause, S.2    McNeil, C.J.3    Pritchard, J.A.4    Armstrong, R.D.5    Athey, D.6
  • 14
    • 0033598186 scopus 로고    scopus 로고
    • Aminiaturized urea sensor based on the integration of both ammonium based urea enzyme field effect transistor and a reference field effect transistor in a single chip
    • S. Anne, J.R. Nicolo, M. Claude, and C. Serge Aminiaturized urea sensor based on the integration of both ammonium based urea enzyme field effect transistor and a reference field effect transistor in a single chip Talanta 50 1999 219 226
    • (1999) Talanta , vol.50 , pp. 219-226
    • Anne, S.1    Nicolo, J.R.2    Claude, M.3    Serge, C.4
  • 15
    • 0016371052 scopus 로고
    • A specific enzyme electrode for urea
    • G.G. Guilbault, and M. Trap A specific enzyme electrode for urea Anal. Chim. Acta 73 1974 355 365
    • (1974) Anal. Chim. Acta , vol.73 , pp. 355-365
    • Guilbault, G.G.1    Trap, M.2
  • 16
    • 33748686365 scopus 로고    scopus 로고
    • A comparative study of immobilization techniques for urease on glass-pH-electrode and its application in urea detection in blood serum
    • R. Sahney, S. Anand, B.K. Puri, and A.K. Srivastava A comparative study of immobilization techniques for urease on glass-pH-electrode and its application in urea detection in blood serum Anal. Chim. Acta 578 2006 156 161
    • (2006) Anal. Chim. Acta , vol.578 , pp. 156-161
    • Sahney, R.1    Anand, S.2    Puri, B.K.3    Srivastava, A.K.4
  • 17
    • 33244471298 scopus 로고    scopus 로고
    • Amperometric enzyme electrode for urea determination using immobilized urease in poly(vinylferrocenium) film
    • F. Kuralay, H. Özyörük, and A. Yildiz Amperometric enzyme electrode for urea determination using immobilized urease in poly(vinylferrocenium) film Sens. Actuators B: Chem. 114 2006 500 506
    • (2006) Sens. Actuators B: Chem. , vol.114 , pp. 500-506
    • Kuralay, F.1    Özyörük, H.2    Yildiz, A.3
  • 20
    • 2442453337 scopus 로고    scopus 로고
    • Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films
    • B. Lakard, G. Herlem, S. Lakard, A. Antoniou, and B. Fahys Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films Biosens. Bioelectron. 19 2004 1641 1647
    • (2004) Biosens. Bioelectron. , vol.19 , pp. 1641-1647
    • Lakard, B.1    Herlem, G.2    Lakard, S.3    Antoniou, A.4    Fahys, B.5
  • 21
    • 22944480858 scopus 로고    scopus 로고
    • Potentiometric enzyme electrode for urea determination using immobilized urease in poly(vinylferrocenium) film
    • F. Kuralay, H. Özyörük, and A. Yildiz Potentiometric enzyme electrode for urea determination using immobilized urease in poly(vinylferrocenium) film Sens. Actuators B: Chem. 109 2005 194 199
    • (2005) Sens. Actuators B: Chem. , vol.109 , pp. 194-199
    • Kuralay, F.1    Özyörük, H.2    Yildiz, A.3
  • 22
    • 0030978501 scopus 로고    scopus 로고
    • Pulsed-amperometric detection of urea in blood samples on a conducting polypyrrole-urease biosensor
    • S.B. Adeloju, S.J. Shaw, and G.G. Wallace Pulsed-amperometric detection of urea in blood samples on a conducting polypyrrole-urease biosensor Anal. Chim. Acta 341 1997 155 160
    • (1997) Anal. Chim. Acta , vol.341 , pp. 155-160
    • Adeloju, S.B.1    Shaw, S.J.2    Wallace, G.G.3
  • 23
    • 0346304911 scopus 로고    scopus 로고
    • Nanotubes from carbon
    • P.M. Ajayan Nanotubes from carbon Chem. Rev. 99 1999 1787 1799
    • (1999) Chem. Rev. , vol.99 , pp. 1787-1799
    • Ajayan, P.M.1
  • 24
    • 11144317784 scopus 로고    scopus 로고
    • An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film
    • V. Rajesh, W. Bisht, K. Takashima, and Kaneto An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film Biomaterials 26 2005 3683 3690
    • (2005) Biomaterials , vol.26 , pp. 3683-3690
    • Rajesh, V.1    Bisht, W.2    Takashima, K.3    Kaneto4
  • 25
    • 4043167652 scopus 로고    scopus 로고
    • Electrochemistry and scanning electron microscopy of polyaniline/ peroxidase-based biosensor
    • N.G.R. Mathebe, A. Morrin, and E.I. Iwuoha Electrochemistry and scanning electron microscopy of polyaniline/peroxidase-based biosensor Talanta 64 2004 115 120
    • (2004) Talanta , vol.64 , pp. 115-120
    • Mathebe, N.G.R.1    Morrin, A.2    Iwuoha, E.I.3
  • 27
    • 0003886884 scopus 로고
    • Chapman & Hall London
    • T.M. Canh Biosensors 1993 Chapman & Hall London 46
    • (1993) Biosensors , pp. 46
    • Canh, T.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.