-
1
-
-
0027272917
-
Polypyrrole-based potentiometric biosensor for urea
-
S.B. Adeloju, S.J. Shaw, and G.G. Wallace Polypyrrole-based potentiometric biosensor for urea Anal. Chim. Acta 281 1993 621 627
-
(1993)
Anal. Chim. Acta
, vol.281
, pp. 621-627
-
-
Adeloju, S.B.1
Shaw, S.J.2
Wallace, G.G.3
-
2
-
-
2442453337
-
Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films
-
B. Lakard, G. Herlem, S. Lakard, A. Antoniou, and B. Fahys Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films Biosens. Bioelectron. 19 2004 1641 1647
-
(2004)
Biosens. Bioelectron.
, vol.19
, pp. 1641-1647
-
-
Lakard, B.1
Herlem, G.2
Lakard, S.3
Antoniou, A.4
Fahys, B.5
-
3
-
-
0141956404
-
A novel urea sensitive biosensor with extended dynamic range based on recombinant urease and ISFETs
-
A.P. Soldatkin, J. Montoriol, W. Sant, C. Martelet, and N. Jaffrezic-Renault A novel urea sensitive biosensor with extended dynamic range based on recombinant urease and ISFETs Biosens. Bioelectron. 19 2003 131 135
-
(2003)
Biosens. Bioelectron.
, vol.19
, pp. 131-135
-
-
Soldatkin, A.P.1
Montoriol, J.2
Sant, W.3
Martelet, C.4
Jaffrezic-Renault, N.5
-
4
-
-
0037667867
-
Portable urea biosensor based on the extended-gate field effect transistor
-
J.C. Chen, J.C. Chou, T.P. Sun, and S.K. Hsiung Portable urea biosensor based on the extended-gate field effect transistor Sens. Actuators B 91 2003 180 186
-
(2003)
Sens. Actuators B
, vol.91
, pp. 180-186
-
-
Chen, J.C.1
Chou, J.C.2
Sun, T.P.3
Hsiung, S.K.4
-
5
-
-
22944480858
-
Potentiometric enzyme electrode for urea determination using immobilized urease in poly(vinylferrocenium) film
-
F. Kuralay, H. Özyörük, and A. Yildiz Potentiometric enzyme electrode for urea determination using immobilized urease in poly(vinylferrocenium) film Sens. Actuators B 109 2 2005 194 199
-
(2005)
Sens. Actuators B
, vol.109
, Issue.2
, pp. 194-199
-
-
Kuralay, F.1
Özyörük, H.2
Yildiz, A.3
-
6
-
-
0017492360
-
Urease coupled ammonia electrode for urea determination in blood serum
-
M. Macsini, and G.G. Guilbault Urease coupled ammonia electrode for urea determination in blood serum Anal. Chem. 49 1977 795 798
-
(1977)
Anal. Chem.
, vol.49
, pp. 795-798
-
-
MacSini, M.1
Guilbault, G.G.2
-
7
-
-
0038682146
-
PH-based potentiometrical flow injection biosensor for urea
-
J.Q. Wang, J.C. Chau, T.P. Sun, S.K. Hsiung, and G.B. Hsiung pH-based potentiometrical flow injection biosensor for urea Sens. Actuators B 91 2003 5 10
-
(2003)
Sens. Actuators B
, vol.91
, pp. 5-10
-
-
Wang, J.Q.1
Chau, J.C.2
Sun, T.P.3
Hsiung, S.K.4
Hsiung, G.B.5
-
8
-
-
0026556776
-
Urea sensors based on glass pH electrodes with physically immobilized urease
-
R. Koncki, P. Leszczyński, A. Hulanicki, and S. Glab Urea sensors based on glass pH electrodes with physically immobilized urease Anal. Chim. Acta 257 1992 67 72
-
(1992)
Anal. Chim. Acta
, vol.257
, pp. 67-72
-
-
Koncki, R.1
Leszczyński, P.2
Hulanicki, A.3
Glab, S.4
-
10
-
-
0035980505
-
Tetraphenylborate doped polyaniline based novel pH sensor and solid-state urea biosensor
-
P.C. Pandey, and G. Singh Tetraphenylborate doped polyaniline based novel pH sensor and solid-state urea biosensor Talanta 55 2001 773 782
-
(2001)
Talanta
, vol.55
, pp. 773-782
-
-
Pandey, P.C.1
Singh, G.2
-
11
-
-
0033702807
-
Amperometric determination of pyruvate, phosphate and urea using enzyme electrodes based on pyruvate oxidase-containing poly(vinyl alcohol)/polyion complex-bilayer membrane
-
F. Mizutani, S. Yabuki, Y. Sato, T. Sawaguchi, and S. Iijima Amperometric determination of pyruvate, phosphate and urea using enzyme electrodes based on pyruvate oxidase-containing poly(vinyl alcohol)/polyion complex-bilayer membrane Electrochim. Acta 45 2000 2945 2952
-
(2000)
Electrochim. Acta
, vol.45
, pp. 2945-2952
-
-
Mizutani, F.1
Yabuki, S.2
Sato, Y.3
Sawaguchi, T.4
Iijima, S.5
-
12
-
-
0030978501
-
Pulsed-amperometric detection of urea in blood samples on a conducting polypyrrole-urease biosensor
-
S.B. Adeloju, S.J. Shaw, and G.G. Wallace Pulsed-amperometric detection of urea in blood samples on a conducting polypyrrole-urease biosensor Anal. Chim. Acta 341 1997 155 160
-
(1997)
Anal. Chim. Acta
, vol.341
, pp. 155-160
-
-
Adeloju, S.B.1
Shaw, S.J.2
Wallace, G.G.3
-
13
-
-
0035943531
-
Interference-free amperometric measurement of urea in biological samples using an electrode coated with tri-enzyme/polydimethylsiloxane-bilayer membrane
-
F. Mizutani, Y. Sato, Y. Hirata, and S. Iijima Interference-free amperometric measurement of urea in biological samples using an electrode coated with tri-enzyme/polydimethylsiloxane-bilayer membrane Anal. Chim. Acta 441 2001 175 181
-
(2001)
Anal. Chim. Acta
, vol.441
, pp. 175-181
-
-
Mizutani, F.1
Sato, Y.2
Hirata, Y.3
Iijima, S.4
-
14
-
-
0345534824
-
Sensor for amperometric determination of ammonia and ammonia-forming enzyme reactions
-
B. Strehlitz, B. Gründig, and H. Kopinke Sensor for amperometric determination of ammonia and ammonia-forming enzyme reactions Anal. Chim. Acta 403 2000 11 23
-
(2000)
Anal. Chim. Acta
, vol.403
, pp. 11-23
-
-
Strehlitz, B.1
Gründig, B.2
Kopinke, H.3
-
15
-
-
0027590935
-
Amperometric ammonium ion sensor and its application to biosensors
-
Y. Yakamoto, and M. Senda Amperometric ammonium ion sensor and its application to biosensors Sens. Actuators B 13 1993 57 60
-
(1993)
Sens. Actuators B
, vol.13
, pp. 57-60
-
-
Yakamoto, Y.1
Senda, M.2
-
16
-
-
0022269018
-
Enzyme electrode for urea with amperometric indication. Part I. Basic principle
-
D. Kirstein, L. Kirstein, and F. Scheller Enzyme electrode for urea with amperometric indication. Part I. Basic principle Biosens. Bioelectron. 1 1985 117 130
-
(1985)
Biosens. Bioelectron.
, vol.1
, pp. 117-130
-
-
Kirstein, D.1
Kirstein, L.2
Scheller, F.3
-
17
-
-
0037094045
-
Amperometric urea biosensor based on urease and electropolymerized toluidine blue dye as a pH-sensitive redox probe
-
I. Vostiar, J. Tkac, E. Sturdik, and P. Gemeiner Amperometric urea biosensor based on urease and electropolymerized toluidine blue dye as a pH-sensitive redox probe Bioelectrochemistry 56 2002 113 115
-
(2002)
Bioelectrochemistry
, vol.56
, pp. 113-115
-
-
Vostiar, I.1
Tkac, J.2
Sturdik, E.3
Gemeiner, P.4
-
18
-
-
0035972824
-
Urea biosensor based on amperometric pH-sensing with hematein as a pH-sensitive redox mediator
-
A. Pizzariello, M. Stredansky, S. Stredanska, and S. Miertus Urea biosensor based on amperometric pH-sensing with hematein as a pH-sensitive redox mediator Talanta 54 2001 763 772
-
(2001)
Talanta
, vol.54
, pp. 763-772
-
-
Pizzariello, A.1
Stredansky, M.2
Stredanska, S.3
Miertus, S.4
-
19
-
-
0034733766
-
Amperometric pH-sensing biosensors for urea, penicillin and oxalacetate
-
M. Stredansky, A. Pizzariello, S. Stredanska, and S. Miertus Amperometric pH-sensing biosensors for urea, penicillin and oxalacetate Anal. Chim. Acta 415 2000 151 157
-
(2000)
Anal. Chim. Acta
, vol.415
, pp. 151-157
-
-
Stredansky, M.1
Pizzariello, A.2
Stredanska, S.3
Miertus, S.4
-
20
-
-
11144317784
-
An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly(N-3-aminopropyl pyrrole-co-pyrrole) film
-
Rajesh, V. Bisht, W. Takashima, and K. Kaneto An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly(N-3-aminopropyl pyrrole-co-pyrrole) film Biomaterials 26 2005 3683 3690
-
(2005)
Biomaterials
, vol.26
, pp. 3683-3690
-
-
Rajesh1
Bisht, V.2
Takashima, W.3
Kaneto, K.4
-
21
-
-
0000334299
-
Cationic polymerization and copolymerization of vinylferrocene
-
B.C. Aso, T. Kunitake, and T. Nakashima Cationic polymerization and copolymerization of vinylferrocene Macromol. Chem. 124 1969 232 239
-
(1969)
Macromol. Chem.
, vol.124
, pp. 232-239
-
-
Aso, B.C.1
Kunitake, T.2
Nakashima, T.3
-
22
-
-
0003041117
-
Polymer films on electrodes. Part II. Film structure and mechanism of electron transfer with electrodeposited poly(vinylferrocene)
-
P.J. Peerce, and A.J. Bard Polymer films on electrodes. Part II. Film structure and mechanism of electron transfer with electrodeposited poly(vinylferrocene) J. Electroanal. Chem. 112 1980 97 115
-
(1980)
J. Electroanal. Chem.
, vol.112
, pp. 97-115
-
-
Peerce, P.J.1
Bard, A.J.2
-
24
-
-
84987564652
-
Electrochemical response of poly(vinylferrocenium)-coated Pt electrodes to some anions in aqueous media
-
H. Gülce, H. Özyörük, and A. Yildiz Electrochemical response of poly(vinylferrocenium)-coated Pt electrodes to some anions in aqueous media Electroanalysis 7 1995 178 183
-
(1995)
Electroanalysis
, vol.7
, pp. 178-183
-
-
Gülce, H.1
Özyörük, H.2
Yildiz, A.3
-
25
-
-
0037111412
-
Amperometric enzyme electrode for l(+)-lactate determination using immobilized l(+)-lactate oxidase in poly(vinylferrocenium) film
-
G. Aydin, S.S. Çelebi, H. Özyörük, and A. Yildiz Amperometric enzyme electrode for l(+)-lactate determination using immobilized l(+)-lactate oxidase in poly(vinylferrocenium) film Sens. Actuators B 87 2002 8 12
-
(2002)
Sens. Actuators B
, vol.87
, pp. 8-12
-
-
Aydin, G.1
Çelebi, S.S.2
Özyörük, H.3
Yildiz, A.4
-
26
-
-
0002406354
-
Amperometric enzyme electrode for aerobic glucose monitoring prepared by glucose oxidase immobilized in poly(vinylferrocenium)
-
H. Gülce, H. Özyörük, S.S. Çelebi, and A. Yildiz Amperometric enzyme electrode for aerobic glucose monitoring prepared by glucose oxidase immobilized in poly(vinylferrocenium) J. Electroanal. Chem. 394 1995 63 70
-
(1995)
J. Electroanal. Chem.
, vol.394
, pp. 63-70
-
-
Gülce, H.1
Özyörük, H.2
Çelebi, S.S.3
Yildiz, A.4
-
27
-
-
0002406356
-
Amperometric enzyme electrode for sucrose determination prepared from glucose oxidase and invertase co-immobilized in poly(vinylferrocenium)
-
H. Gülce, S.S. Çelebi, H. Özyörük, and A. Yildiz Amperometric enzyme electrode for sucrose determination prepared from glucose oxidase and invertase co-immobilized in poly(vinylferrocenium) J. Electroanal. Chem. 397 1995 217 223
-
(1995)
J. Electroanal. Chem.
, vol.397
, pp. 217-223
-
-
Gülce, H.1
Çelebi, S.S.2
Özyörük, H.3
Yildiz, A.4
-
29
-
-
1942531130
-
Amperometric enzyme electrode for organic peroxides determination prepared from horseradish peroxidase immobilized in poly(vinylferrocenium) film
-
M. Gündoǧan-Paul, S.S. Çelebi, H. Özyö rük, and A. Yildiz Amperometric enzyme electrode for organic peroxides determination prepared from horseradish peroxidase immobilized in poly(vinylferrocenium) film Biosens. Bioelectron. 17 2002 875 881
-
(2002)
Biosens. Bioelectron.
, vol.17
, pp. 875-881
-
-
Gündoǧan-Paul, M.1
Çelebi, S.S.2
Özyörük, H.3
Yildiz, A.4
-
30
-
-
0004053611
-
-
John Wiley and Sons Inc. New York
-
D. Voet, and J.G. Voet Biochemistry 1995 John Wiley and Sons Inc. New York p. 332
-
(1995)
Biochemistry
-
-
Voet, D.1
Voet, J.G.2
-
31
-
-
1642323385
-
Development of urease and glutamic dehydrogenase amperometric assay for heavy metals screening in polluted samples
-
B. Bello Rodriguez, J.A. Bolbot, and I.E. Tothill Development of urease and glutamic dehydrogenase amperometric assay for heavy metals screening in polluted samples Biosens. Bioelectron. 19 2004 1157 1167
-
(2004)
Biosens. Bioelectron.
, vol.19
, pp. 1157-1167
-
-
Bello Rodriguez, B.1
Bolbot, J.A.2
Tothill, I.E.3
|