메뉴 건너뛰기




Volumn 16, Issue 2, 2014, Pages 172-177

Effect of dental implant diameter on fatigue performance. Part I: Mechanical behavior

Author keywords

Cycles; Load; Normalized load; Probability of fracture; S N curve

Indexed keywords

TITANIUM; TITANIUM ALLOY (TIAL6V4); TOOTH IMPLANT;

EID: 84899650683     PISSN: 15230899     EISSN: 17088208     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2012.00477.x     Document Type: Article
Times cited : (52)

References (16)
  • 1
    • 70349419552 scopus 로고    scopus 로고
    • Evaluation of test protocol variables for dental implant fatigue research
    • Lee CK, Karl M, Kelly JR. Evaluation of test protocol variables for dental implant fatigue research. Dent Mater 2009; 25:1419-1425.
    • (2009) Dent Mater , vol.25 , pp. 1419-1425
    • Lee, C.K.1    Karl, M.2    Kelly, J.R.3
  • 3
    • 77954616080 scopus 로고    scopus 로고
    • Long-term implant survival and success: a 10-16-year follow-up of non-submerged dental implants
    • Simonis P, Dufour T, Tenenbaum H. Long-term implant survival and success: a 10-16-year follow-up of non-submerged dental implants. Clin Oral Implants Res 2010; 21:772-777.
    • (2010) Clin Oral Implants Res , vol.21 , pp. 772-777
    • Simonis, P.1    Dufour, T.2    Tenenbaum, H.3
  • 4
    • 0030236468 scopus 로고    scopus 로고
    • An analysis and management of fractured implants: a clinical report
    • Balshi TJ. An analysis and management of fractured implants: a clinical report. Int J Oral Maxillofac Implants 1996; 11:660-666.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 660-666
    • Balshi, T.J.1
  • 6
    • 76949084133 scopus 로고    scopus 로고
    • Evaluation of 316 narrow diameter implants followed for 5-10 years: a clinical and radiographic retrospective study
    • Arisan V, Bölükbaşi N, Ersanli S, Ozdemir T. Evaluation of 316 narrow diameter implants followed for 5-10 years: a clinical and radiographic retrospective study. Clin Oral Implants Res 2010; 21:296-307.
    • (2010) Clin Oral Implants Res , vol.21 , pp. 296-307
    • Arisan, V.1    Bölükbaşi, N.2    Ersanli, S.3    Ozdemir, T.4
  • 8
    • 43449108575 scopus 로고    scopus 로고
    • The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study
    • Allum SR, Tomlinson RA, Joshi R. The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study. Clin Oral Implants Res 2008; 19:553-559.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 553-559
    • Allum, S.R.1    Tomlinson, R.A.2    Joshi, R.3
  • 12
    • 84884124962 scopus 로고    scopus 로고
    • ISO 14801. . Geneva: International Organization for Standardization
    • ISO 14801. Fatigue Test for Endosseous Dental Implants. Geneva: International Organization for Standardization, 2007.
    • (2007) Fatigue Test for Endosseous Dental Implants
  • 13
    • 0032626508 scopus 로고    scopus 로고
    • There is no infinite fatigue life in metallic materials
    • Bathias C. There is no infinite fatigue life in metallic materials. Fatigue Fract Engng Mater Struct 1999; 22:559-565.
    • (1999) Fatigue Fract Engng Mater Struct , vol.22 , pp. 559-565
    • Bathias, C.1
  • 14
    • 33846290368 scopus 로고    scopus 로고
    • Load fatigue performance of a single-tooth implant abutment system: effect of diameter
    • Quek CE, Tan KB, Nicholls JI. Load fatigue performance of a single-tooth implant abutment system: effect of diameter. Int J Oral Maxillofac Implants 2006; 21:929-936.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 929-936
    • Quek, C.E.1    Tan, K.B.2    Nicholls, J.I.3
  • 15


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.