메뉴 건너뛰기




Volumn 20, Issue 6, 2005, Pages 854-859

Evaluation of loading conditions on fatigue-failed implants by fracture surface analysis

Author keywords

Dental implants; Fatigue; Finite element analysis; Implant fractures; Scanning electron micrography

Indexed keywords

ARTICLE; DENTAL SURGERY; EQUIPMENT; FINITE ELEMENT ANALYSIS; MECHANICAL STRESS; SCANNING ELECTRON MICROSCOPY; SURFACE PROPERTY; TOOTH IMPLANTATION; WEIGHT BEARING;

EID: 30844453838     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (43)

References (23)
  • 1
    • 0026218667 scopus 로고
    • Failure and complications in 391 consecutive inserted fixed prostheses supported by Brånemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup
    • Jemt T. Failure and complications in 391 consecutive inserted fixed prostheses supported by Brånemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6:270-276.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 270-276
    • Jemt, T.1
  • 2
    • 85006809401 scopus 로고
    • Osseointegrated implants in the treatment of partially edentulous jaws: A prospective 5-year multicenter study
    • Lekholm U, Van Steenberghe D, Herrmann I, et al. Osseointegrated implants in the treatment of partially edentulous jaws: A prospective 5-year multicenter study. Int J Oral Maxillofac Implants 1994;9:627-635.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 627-635
    • Lekholm, U.1    Van Steenberghe, D.2    Herrmann, I.3
  • 3
    • 0026832538 scopus 로고
    • Failures and complications in 127 consecutively placed fixed partial prostheses supported by Brånemark implants: From prosthetic treatment to first annual checkup
    • Jemt T, Linden B, Lekholm U. Failures and complications in 127 consecutively placed fixed partial prostheses supported by Brånemark implants: From prosthetic treatment to first annual checkup. Int J Oral Maxillofac Implants 1992;7:40-44.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 40-44
    • Jemt, T.1    Linden, B.2    Lekholm, U.3
  • 4
    • 0035375020 scopus 로고    scopus 로고
    • Dynamic fatigue properties of the dental implant-abutment interface: Joint opening in wide-diameter versus standard-diameter hex-type implants
    • Hoyer HA, Stanford CM, Buranadham S, Fridrich T, Wagner J, Gratton D. Dynamic fatigue properties of the dental implant-abutment interface: Joint opening in wide-diameter versus standard-diameter hex-type implants. J Prosthet Dent 2001;85:599-607.
    • (2001) J Prosthet Dent , vol.85 , pp. 599-607
    • Hoyer, H.A.1    Stanford, C.M.2    Buranadham, S.3    Fridrich, T.4    Wagner, J.5    Gratton, D.6
  • 6
    • 0029302999 scopus 로고
    • Nonlinear contact analysis of preload in dental implant screws
    • Sakaguchi RL, Borgersen SE. Nonlinear contact analysis of preload in dental implant screws. Int J Oral Maxillofac Implants 1995;10:295-302.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 295-302
    • Sakaguchi, R.L.1    Borgersen, S.E.2
  • 7
    • 0029204703 scopus 로고
    • Comparative study of antirotational single tooth abutments
    • Balfour A, O'Brien GR. Comparative study of antirotational single tooth abutments. J Prosthet Dent 1995;73:36-43.
    • (1995) J Prosthet Dent , vol.73 , pp. 36-43
    • Balfour, A.1    O'Brien, G.R.2
  • 9
    • 0033210778 scopus 로고    scopus 로고
    • Influence of hex geometry and prosthetic table width on static and fatigue strength of dental implants
    • Boggan RS, Strong JT, Misch CE, Bidez MW. Influence of hex geometry and prosthetic table width on static and fatigue strength of dental implants. J Prosthet Dent 1999;82:436-440.
    • (1999) J Prosthet Dent , vol.82 , pp. 436-440
    • Boggan, R.S.1    Strong, J.T.2    Misch, C.E.3    Bidez, M.W.4
  • 11
    • 0028709614 scopus 로고
    • Fracture surface characterization of clinically failed all-ceramic crowns
    • Thompson JY, Anusavice KJ, Naman A, Morris HF. Fracture surface characterization of clinically failed all-ceramic crowns. J Dent Res 1994;73:1824-1832.
    • (1994) J Dent Res , vol.73 , pp. 1824-1832
    • Thompson, J.Y.1    Anusavice, K.J.2    Naman, A.3    Morris, H.F.4
  • 12
    • 0029258615 scopus 로고
    • Fracture mechanics principles
    • Mecholsky JJ Jr. Fracture mechanics principles. Dent Mater 1995;11:111-112.
    • (1995) Dent Mater , vol.11 , pp. 111-112
    • Mecholsky Jr., J.J.1
  • 13
    • 0029258584 scopus 로고
    • Fractography: Determining the sites of fracture initiation
    • Mecholsky JJ Jr. Fractography: Determining the sites of fracture initiation. Dent Mater 1995;11:113-116.
    • (1995) Dent Mater , vol.11 , pp. 113-116
    • Mecholsky Jr., J.J.1
  • 14
    • 0029382643 scopus 로고
    • Deflection fatigue of cobalt-chromium, titanium, and gold alloy cast denture clasp
    • Vallittu PK, Kokkonen M. Deflection fatigue of cobalt-chromium, titanium, and gold alloy cast denture clasp. J Prosthet Dent 1995;74:412-419.
    • (1995) J Prosthet Dent , vol.74 , pp. 412-419
    • Vallittu, P.K.1    Kokkonen, M.2
  • 15
    • 0030202588 scopus 로고    scopus 로고
    • Fracture surface characteristics of damaged acrylic-resin-based dentures as analyzed by SEM - Replica technique
    • Vallittu PK. Fracture surface characteristics of damaged acrylic-resin-based dentures as analyzed by SEM - Replica technique. J Oral Rehabil 1996;23:524-529.
    • (1996) J Oral Rehabil , vol.23 , pp. 524-529
    • Vallittu, P.K.1
  • 16
    • 0031157322 scopus 로고    scopus 로고
    • Brazing joints of gold alloy used in porcelain-fused-to-metal restorations and their resistance to deflection fatigue
    • Vallittu PK. Brazing joints of gold alloy used in porcelain-fused-to- metal restorations and their resistance to deflection fatigue. J Oral Rehabil 1997;24:444-448.
    • (1997) J Oral Rehabil , vol.24 , pp. 444-448
    • Vallittu, P.K.1
  • 18
    • 0030275656 scopus 로고    scopus 로고
    • The effect of eliminating implant/abutment relational misfit on screw joint stability
    • Binon PP, McHugh MJ. The effect of eliminating implant/abutment relational misfit on screw joint stability. Int J Prosthodont 1996;9:511-519.
    • (1996) Int J Prosthodont , vol.9 , pp. 511-519
    • Binon, P.P.1    McHugh, M.J.2
  • 19
    • 0346276532 scopus 로고    scopus 로고
    • Clinical biomechanics in implant dentistry
    • Misch CE (ed). St Louis: CV Mosby
    • Bidez MW, Misch CE. Clinical biomechanics in implant dentistry. In: Misch CE (ed). Contemporary Implant Dentistry, ed 2. St Louis: CV Mosby, 1999:303-316.
    • (1999) Contemporary Implant Dentistry, Ed 2 , pp. 303-316
    • Bidez, M.W.1    Misch, C.E.2
  • 21
    • 0029262154 scopus 로고
    • Stress fatigue: Basic principles and prosthodontic implications
    • Wiskott HWA, Nicholls JI, Belser UC. Stress fatigue: Basic principles and prosthodontic implications. Int J Prosthodont 1995;8:105-116.
    • (1995) Int J Prosthodont , vol.8 , pp. 105-116
    • Wiskott, H.W.A.1    Nicholls, J.I.2    Belser, U.C.3
  • 23


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.