메뉴 건너뛰기




Volumn 4, Issue 1, 2014, Pages 1-9

Optimal care and design of the tracheal cuff in the critically ill patient

Author keywords

Complications; Intubation; Microaspiration; Tracheal ischemia; Ventilator associated pneumonia

Indexed keywords

ASPIRATION; COMPLICATION; CRITICALLY ILL PATIENT; CUFF PRESSURE; ENDOTRACHEAL TUBE; ENDOTRACHEAL TUBE CUFF; EQUIPMENT DESIGN; HUMAN; INTUBATION; INTUBATION RELATED COMPLICATION; ISCHEMIA; MICROASPIRATION; MORBIDITY; MORTALITY; PATIENT CARE; PRESSURE VOLUME CURVE; PRIORITY JOURNAL; REVIEW; TRACHEA DISEASE; TRACHEAL ISCHEMIA; VENTILATOR ASSOCIATED PNEUMONIA;

EID: 84899443969     PISSN: None     EISSN: 21105820     Source Type: Journal    
DOI: 10.1186/2110-5820-4-7     Document Type: Review
Times cited : (30)

References (72)
  • 2
    • 84878407584 scopus 로고    scopus 로고
    • Noninvasive ventilation for acute respiratory failure
    • Hess DR: Noninvasive ventilation for acute respiratory failure. Respir Care 2013, 58:950-972.
    • (2013) Respir Care , vol.58 , pp. 950-972
    • Hess, D.R.1
  • 4
    • 82555197918 scopus 로고    scopus 로고
    • Beneficial effects of humidified high flow nasal oxygen in critical care patients: A prospective pilot study
    • Sztrymf B, Messika J, Bertrand F, Hurel D, Leon R, Dreyfuss D, Ricard J-D: Beneficial effects of humidified high flow nasal oxygen in critical care patients: a prospective pilot study. Intensive Care Med 2011, 37:1780-1786.
    • (2011) Intensive Care Med , vol.37 , pp. 1780-1786
    • Sztrymf, B.1    Messika, J.2    Bertrand, F.3    Hurel, D.4    Leon, R.5    Dreyfuss, D.6    Ricard, J.-D.7
  • 7
    • 60249102733 scopus 로고    scopus 로고
    • Ventilator-associated tracheobronchitis: The impact of targeted antibiotic therapy on patient outcomes
    • Craven DE, Chroneou A, Zias N, Hjalmarson KI: Ventilator-associated tracheobronchitis: the impact of targeted antibiotic therapy on patient outcomes. Chest 2009, 135:521-528.
    • (2009) Chest , vol.135 , pp. 521-528
    • Craven, D.E.1    Chroneou, A.2    Zias, N.3    Hjalmarson, K.I.4
  • 8
    • 33645836530 scopus 로고    scopus 로고
    • Tracheobronchial aspiration of gastric contents in critically ill tube-fed patients: Frequency, outcomes, and risk factors
    • Metheny NA, Clouse RE, Chang Y-H, Stewart BJ, Oliver DA, Kollef MH: Tracheobronchial aspiration of gastric contents in critically ill tube-fed patients: frequency, outcomes, and risk factors. Crit Care Med 2006, 34:1007-1015.
    • (2006) Crit Care Med , vol.34 , pp. 1007-1015
    • Metheny, N.A.1    Clouse, R.E.2    Chang, Y.-H.3    Stewart, B.J.4    Oliver, D.A.5    Kollef, M.H.6
  • 9
    • 79953216327 scopus 로고    scopus 로고
    • 2-agonists and ventilator-associated pneumonia: A cohort study
    • Jaillette E, Nseir S: Relationship between inhaled β2-agonists and ventilator-associated pneumonia: a cohort study. Crit Care Med 2011, 39:725-730.
    • (2011) Crit Care Med , vol.39 , pp. 725-730
    • Jaillette, E.1    Nseir, S.2
  • 11
    • 0031030467 scopus 로고    scopus 로고
    • Influence of airway pressure on minimum occlusive endotracheal tube cuff pressure
    • Guyton DC, Barlow MR, Besselievre TR: Influence of airway pressure on minimum occlusive endotracheal tube cuff pressure. Crit Care Med 1997, 25:91-94.
    • (1997) Crit Care Med , vol.25 , pp. 91-94
    • Guyton, D.C.1    Barlow, M.R.2    Besselievre, T.R.3
  • 14
    • 0030962932 scopus 로고    scopus 로고
    • Leakage of fluid past the tracheal tube cuff in a benchtop model
    • Young PJ, Rollinson M, Downward G, Henderson S: Leakage of fluid past the tracheal tube cuff in a benchtop model. Br J Anaesth 1997, 78:557-562.
    • (1997) Br J Anaesth , vol.78 , pp. 557-562
    • Young, P.J.1    Rollinson, M.2    Downward, G.3    Henderson, S.4
  • 15
    • 84871117235 scopus 로고    scopus 로고
    • Effect of tracheal suctioning on aspiration past the tracheal tube cuff in mechanically ventilated patients
    • Beuret P, Philippon B, Fabre X, Kaaki M: Effect of tracheal suctioning on aspiration past the tracheal tube cuff in mechanically ventilated patients. Ann Intensive Care 2012, 2:45.
    • (2012) Ann Intensive Care , vol.2 , pp. 45
    • Beuret, P.1    Philippon, B.2    Fabre, X.3    Kaaki, M.4
  • 16
    • 21744452169 scopus 로고    scopus 로고
    • Early gastrostomy reduces the rate of ventilator-associated pneumonia in stroke or head injury patients
    • Kostadima E, Kaditis AG, Alexopoulos EI, Zakynthinos E, Sfyras D: Early gastrostomy reduces the rate of ventilator-associated pneumonia in stroke or head injury patients. Eur Respir J 2005, 26:106-111.
    • (2005) Eur Respir J , vol.26 , pp. 106-111
    • Kostadima, E.1    Kaditis, A.G.2    Alexopoulos, E.I.3    Zakynthinos, E.4    Sfyras, D.5
  • 18
    • 0031011848 scopus 로고    scopus 로고
    • Physiological hyperglycemia slows gastric emptying in normal subjects and patients with insulin-dependent diabetes mellitus
    • Schvarcz E, Palmér M, Aman J, Horowitz M, Stridsberg M, Berne C: Physiological hyperglycemia slows gastric emptying in normal subjects and patients with insulin-dependent diabetes mellitus. Gastroenterology 1997, 113:60-66.
    • (1997) Gastroenterology , vol.113 , pp. 60-66
    • Schvarcz, E.1    Palmér, M.2    Aman, J.3    Horowitz, M.4    Stridsberg, M.5    Berne, C.6
  • 20
    • 0029091511 scopus 로고
    • Semirecumbent position protects from pulmonary aspiration but not completely from gastroesophageal reflux in mechanically ventilated patients
    • Orozco-Levi M, Torres A, Ferrer M, Piera C, el-Ebiary M, de la Bellacasa JP, Rodriguez-Roisin R: Semirecumbent position protects from pulmonary aspiration but not completely from gastroesophageal reflux in mechanically ventilated patients. Am J Respir Crit Care Med 1995, 152(4 Pt 1):1387-1390.
    • (1995) Am J Respir Crit Care Med , vol.152 , Issue.4 Pt 1 , pp. 1387-1390
    • Orozco-Levi, M.1    Torres, A.2    Ferrer, M.3    Piera, C.4    El-Ebiary, M.5    de la Bellacasa, J.P.6    Rodriguez-Roisin, R.7
  • 21
    • 0034893789 scopus 로고    scopus 로고
    • Effect of postpyloric feeding on gastroesophageal regurgitation and pulmonary microaspiration: Results of a randomized controlled trial
    • Heyland DK, Drover JW, MacDonald S, Novak F, Lam M: Effect of postpyloric feeding on gastroesophageal regurgitation and pulmonary microaspiration: results of a randomized controlled trial. Crit Care Med 2001, 29:1495-1501.
    • (2001) Crit Care Med , vol.29 , pp. 1495-1501
    • Heyland, D.K.1    Drover, J.W.2    Macdonald, S.3    Novak, F.4    Lam, M.5
  • 25
    • 84874942492 scopus 로고    scopus 로고
    • Bronchoalveolar lavage amylase is associated with risk factors for aspiration and predicts bacterial pneumonia
    • Weiss CH, Moazed F, DiBardino D, Swaroop M, Wunderink RG: Bronchoalveolar lavage amylase is associated with risk factors for aspiration and predicts bacterial pneumonia. Crit Care Med 2013, 41:765-773.
    • (2013) Crit Care Med , vol.41 , pp. 765-773
    • Weiss, C.H.1    Moazed, F.2    Dibardino, D.3    Swaroop, M.4    Wunderink, R.G.5
  • 26
    • 0019352225 scopus 로고
    • Complications and consequences of endotracheal intubation and tracheotomy. A prospective study of 150 critically ill adult patients
    • Stauffer JL, Olson DE, Petty TL: Complications and consequences of endotracheal intubation and tracheotomy. A prospective study of 150 critically ill adult patients. Am J Med 1981, 70:65-76.
    • (1981) Am J Med , vol.70 , pp. 65-76
    • Stauffer, J.L.1    Olson, D.E.2    Petty, T.L.3
  • 27
    • 0020965168 scopus 로고
    • Laryngotracheal injury due to endotracheal intubation: Incidence, evolution, and predisposing factors. A prospective long-term study
    • Kastanos N, Estopá Miró R, Marín Perez A, Xaubet Mir A, Agustí-Vidal A: Laryngotracheal injury due to endotracheal intubation: incidence, evolution, and predisposing factors. A prospective long-term study. Crit Care Med 1983, 11:362-367.
    • (1983) Crit Care Med , vol.11 , pp. 362-367
    • Kastanos, N.1    Estopá, M.R.2    Marín, P.A.3    Xaubet, M.A.4    Agustí-Vidal, A.5
  • 29
    • 0021260456 scopus 로고
    • Endotracheal cuff pressure and tracheal mucosal blood flow: Endoscopic study of effects of four large volume cuffs
    • Seegobin RD, van Hasselt GL: Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs. Br Med J (Clin Res Ed) 1984, 288:965-968.
    • (1984) Br Med J (Clin Res Ed) , vol.288 , pp. 965-968
    • Seegobin, R.D.1    van Hasselt, G.L.2
  • 30
    • 33144483083 scopus 로고    scopus 로고
    • Experienced emergency medicine physicians cannot safely inflate or estimate endotracheal tube cuff pressure using standard techniques
    • Hoffman RJ, Parwani V, Hahn I-H: Experienced emergency medicine physicians cannot safely inflate or estimate endotracheal tube cuff pressure using standard techniques. Am J Emerg Med 2006, 24:139-143.
    • (2006) Am J Emerg Med , vol.24 , pp. 139-143
    • Hoffman, R.J.1    Parwani, V.2    Hahn, I.-H.3
  • 31
    • 0021811123 scopus 로고
    • Intracuff pressures in endotracheal and tracheostomy tubes. Related cuff physical characteristics
    • Bernhard WN, Yost L, Joynes D, Cothalis S, Turndorf H: Intracuff pressures in endotracheal and tracheostomy tubes. Related cuff physical characteristics. Chest 1985, 87:720-725.
    • (1985) Chest , vol.87 , pp. 720-725
    • Bernhard, W.N.1    Yost, L.2    Joynes, D.3    Cothalis, S.4    Turndorf, H.5
  • 33
    • 84891803442 scopus 로고    scopus 로고
    • Cuff pressure of endotracheal tubes after changes in body position in critically ill patients treated with mechanical ventilation
    • Lizy C, Swinnen W, Labeau S, Poelaert J, Vogelaers D, Vandewoude K, Dulhunty J, Blot S: Cuff pressure of endotracheal tubes after changes in body position in critically ill patients treated with mechanical ventilation. Am J Crit Care 2014, 23:e1-e8.
    • (2014) Am J Crit Care , vol.23
    • Lizy, C.1    Swinnen, W.2    Labeau, S.3    Poelaert, J.4    Vogelaers, D.5    Vandewoude, K.6    Dulhunty, J.7    Blot, S.8
  • 34
    • 0027314798 scopus 로고
    • Canine tracheal blood flow after endotracheal tube cuff inflation during normotension and hypotension
    • Bunegin L, Albin MS, Smith RB: Canine tracheal blood flow after endotracheal tube cuff inflation during normotension and hypotension. Anesth Analg 1993, 76:1083-1090.
    • (1993) Anesth Analg , vol.76 , pp. 1083-1090
    • Bunegin, L.1    Albin, M.S.2    Smith, R.B.3
  • 36
    • 48949119096 scopus 로고    scopus 로고
    • Early biochemical markers of inflammation in a swine model of endotracheal intubation
    • Puyo CA, Tricomi SM, Dahms TE: Early biochemical markers of inflammation in a swine model of endotracheal intubation. Anesthesiology 2008, 109:88-94.
    • (2008) Anesthesiology , vol.109 , pp. 88-94
    • Puyo, C.A.1    Tricomi, S.M.2    Dahms, T.E.3
  • 38
    • 84887024159 scopus 로고    scopus 로고
    • Intermittent subglottic secretion drainage may cause tracheal damage in patients with few oropharyngeal secretions
    • Suys E, Nieboer K, Stiers W, de Regt J, Huyghens L, Spapen H: Intermittent subglottic secretion drainage may cause tracheal damage in patients with few oropharyngeal secretions. Intensive Crit Care Nurs 2013, 29:317-320.
    • (2013) Intensive Crit Care Nurs , vol.29 , pp. 317-320
    • Suys, E.1    Nieboer, K.2    Stiers, W.3    de Regt, J.4    Huyghens, L.5    Spapen, H.6
  • 39
    • 0017357049 scopus 로고
    • The trachea and cuff-induced tracheal injury. An experimental study on causative factors and prevention
    • Nordin U: The trachea and cuff-induced tracheal injury. An experimental study on causative factors and prevention. Acta Otolaryngol Suppl 1977, 345:1-71.
    • (1977) Acta Otolaryngol Suppl , vol.345 , pp. 1-71
    • Nordin, U.1
  • 40
    • 0033833858 scopus 로고    scopus 로고
    • Obstructive fibrinous tracheal pseudomembrane. A potentially fatal complication of tracheal intubation
    • Deslée G, Brichet A, Lebuffe G, Copin MC, Ramon P, Marquette CH: Obstructive fibrinous tracheal pseudomembrane. A potentially fatal complication of tracheal intubation. Am J Respir Crit Care Med 2000, 162(3 Pt 1):1169-1171.
    • (2000) Am J Respir Crit Care Med , vol.162 , Issue.3 Pt 1 , pp. 1169-1171
    • Deslée, G.1    Brichet, A.2    Lebuffe, G.3    Copin, M.C.4    Ramon, P.5    Marquette, C.H.6
  • 43
    • 33845869788 scopus 로고    scopus 로고
    • Tracheoinnominate artery fistula: Combined endovascular and surgical management by emergency stent-graft placement followed by cryopreserved arterial allograft repair
    • Sessa C, Costache V, Porcu P, Thony F, Blin D, Brichon P-Y, Magne JL: Tracheoinnominate artery fistula: combined endovascular and surgical management by emergency stent-graft placement followed by cryopreserved arterial allograft repair. Ann Vasc Surg 2006, 20:731-735.
    • (2006) Ann Vasc Surg , vol.20 , pp. 731-735
    • Sessa, C.1    Costache, V.2    Porcu, P.3    Thony, F.4    Blin, D.5    Brichon, P.-Y.6    Magne, J.L.7
  • 44
    • 38549162336 scopus 로고    scopus 로고
    • Acquired tracheoesophageal fistula due to high intracuff pressure
    • Hameed AA, Mohamed H, Al-Mansoori M: Acquired tracheoesophageal fistula due to high intracuff pressure. Ann Thorac Med 2008, 3:23-25.
    • (2008) Ann Thorac Med , vol.3 , pp. 23-25
    • Hameed, A.A.1    Mohamed, H.2    Al-Mansoori, M.3
  • 45
    • 0018186401 scopus 로고
    • Tracheal pathology following short-term intubation with low- and high-pressure endotracheal tube cuffs
    • Loeser EA, Hodges M, Gliedman J, Stanley TH, Johansen RK, Yonetani D: Tracheal pathology following short-term intubation with low- and high-pressure endotracheal tube cuffs. Anesth Analg 1978, 57:577-579.
    • (1978) Anesth Analg , vol.57 , pp. 577-579
    • Loeser, E.A.1    Hodges, M.2    Gliedman, J.3    Stanley, T.H.4    Johansen, R.K.5    Yonetani, D.6
  • 46
    • 0019948391 scopus 로고
    • Tracheal damage after endotracheal intubation: Comparison of two types of endotracheal tubes
    • Honeybourne D, Costello JC, Barham C: Tracheal damage after endotracheal intubation: comparison of two types of endotracheal tubes. Thorax 1982, 37:500-502.
    • (1982) Thorax , vol.37 , pp. 500-502
    • Honeybourne, D.1    Costello, J.C.2    Barham, C.3
  • 48
    • 0026051587 scopus 로고
    • High-volume, low-pressure cuffs. Are they always low pressure?
    • Guyton D, Banner MJ, Kirby RR: High-volume, low-pressure cuffs. Are they always low pressure? Chest 1991, 100:1076-1081.
    • (1991) Chest , vol.100 , pp. 1076-1081
    • Guyton, D.1    Banner, M.J.2    Kirby, R.R.3
  • 49
    • 33644598324 scopus 로고    scopus 로고
    • A low-volume, low-pressure tracheal tube cuff reduces pulmonary aspiration
    • Young PJ, Pakeerathan S, Blunt MC, Subramanya S: A low-volume, low-pressure tracheal tube cuff reduces pulmonary aspiration. Crit Care Med 2006, 34:632-639.
    • (2006) Crit Care Med , vol.34 , pp. 632-639
    • Young, P.J.1    Pakeerathan, S.2    Blunt, M.C.3    Subramanya, S.4
  • 50
    • 79955073331 scopus 로고    scopus 로고
    • The incidence of ventilator-associated pneumonia using the PneuX system with or without elective endotracheal tube exchange: A pilot study
    • Doyle A, Fletcher A, Carter J, Blunt M, Young P: The incidence of ventilator-associated pneumonia using the PneuX system with or without elective endotracheal tube exchange: a pilot study. BMC Res Notes 2011, 4:92.
    • (2011) BMC Res Notes , vol.4 , pp. 92
    • Doyle, A.1    Fletcher, A.2    Carter, J.3    Blunt, M.4    Young, P.5
  • 51
    • 77956941426 scopus 로고    scopus 로고
    • Effect of tracheal tube cuff shape on fluid leakage across the cuff: An in vitro study
    • Dave MH, Frotzler A, Spielmann N, Madjdpour C, Weiss M: Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study. Br J Anaesth 2010, 105:538-543.
    • (2010) Br J Anaesth , vol.105 , pp. 538-543
    • Dave, M.H.1    Frotzler, A.2    Spielmann, N.3    Madjdpour, C.4    Weiss, M.5
  • 52
    • 79953826042 scopus 로고    scopus 로고
    • Fluid leakage across tracheal tube cuff, effect of different cuff material, shape, and positive expiratory pressure: A bench-top study
    • Zanella A, Scaravilli V, Isgrò S, Milan M, Cressoni M, Patroniti N, Fumagalli R, Pesenti A: Fluid leakage across tracheal tube cuff, effect of different cuff material, shape, and positive expiratory pressure: a bench-top study. Intensive Care Med 2011, 37:343-347.
    • (2011) Intensive Care Med , vol.37 , pp. 343-347
    • Zanella, A.1    Scaravilli, V.2    Isgrò, S.3    Milan, M.4    Cressoni, M.5    Patroniti, N.6    Fumagalli, R.7    Pesenti, A.8
  • 53
    • 84873360319 scopus 로고    scopus 로고
    • An in vitro study to assess determinant features associated with fluid sealing in the design of endotracheal tube cuffs and exerted tracheal pressures
    • Li Bassi G, Ranzani OT, Marti JD, Giunta V, Luque N, Isetta V, Ferrer M, Farre R, Pimentel GL, Torres A: An in vitro study to assess determinant features associated with fluid sealing in the design of endotracheal tube cuffs and exerted tracheal pressures. Crit Care Med 2013, 41:518-526.
    • (2013) Crit Care Med , vol.41 , pp. 518-526
    • Li Bassi, G.1    Ranzani, O.T.2    Marti, J.D.3    Giunta, V.4    Luque, N.5    Isetta, V.6    Ferrer, M.7    Farre, R.8    Pimentel, G.L.9    Torres, A.10
  • 55
    • 38549158409 scopus 로고    scopus 로고
    • Effect of positive expiratory pressure and type of tracheal cuff on the incidence of aspiration in mechanically ventilated patients in an intensive care unit
    • Lucangelo U, Zin WA, Antonaglia V, Petrucci L, Viviani M, Buscema G, Borelli M, Berlot G: Effect of positive expiratory pressure and type of tracheal cuff on the incidence of aspiration in mechanically ventilated patients in an intensive care unit. Crit Care Med 2008, 36:409-413.
    • (2008) Crit Care Med , vol.36 , pp. 409-413
    • Lucangelo, U.1    Zin, W.A.2    Antonaglia, V.3    Petrucci, L.4    Viviani, M.5    Buscema, G.6    Borelli, M.7    Berlot, G.8
  • 56
    • 77954386083 scopus 로고    scopus 로고
    • Impact of polyurethane on variations in tracheal cuff pressure in critically ill patients: A prospective observational study
    • Nseir S, Zerimech F, de Jonckheere J, Alves I, Balduyck M, Durocher A: Impact of polyurethane on variations in tracheal cuff pressure in critically ill patients: a prospective observational study. Intensive Care Med 2010, 36:1156-1163.
    • (2010) Intensive Care Med , vol.36 , pp. 1156-1163
    • Nseir, S.1    Zerimech, F.2    de Jonckheere, J.3    Alves, I.4    Balduyck, M.5    Durocher, A.6
  • 59
    • 36849046753 scopus 로고    scopus 로고
    • Influence of an endotracheal tube with polyurethane cuff and subglottic secretion drainage on pneumonia
    • Lorente L, Lecuona M, Jiménez A, Mora ML, Sierra A: Influence of an endotracheal tube with polyurethane cuff and subglottic secretion drainage on pneumonia. Am J Respir Crit Care Med 2007, 176:1079-1083.
    • (2007) Am J Respir Crit Care Med , vol.176 , pp. 1079-1083
    • Lorente, L.1    Lecuona, M.2    Jiménez, A.3    Mora, M.L.4    Sierra, A.5
  • 60
    • 40949155070 scopus 로고    scopus 로고
    • Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: A pilot study
    • Poelaert J, Depuydt P, de Wolf A, van de Velde S, Herck I, Blot S: Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: a pilot study. J Thorac Cardiovasc Surg 2008, 135:771-776.
    • (2008) J Thorac Cardiovasc Surg , vol.135 , pp. 771-776
    • Poelaert, J.1    Depuydt, P.2    de Wolf, A.3    van de Velde, S.4    Herck, I.5    Blot, S.6
  • 62
    • 0036798301 scopus 로고    scopus 로고
    • Automatic regulation of the cuff pressure in endotracheally-intubated patients
    • Farré R, Rotger M, Ferre M, Torres A, Navajas D: Automatic regulation of the cuff pressure in endotracheally-intubated patients. Eur Respir J 2002, 20:1010-1013.
    • (2002) Eur Respir J , vol.20 , pp. 1010-1013
    • Farré, R.1    Rotger, M.2    Ferre, M.3    Torres, A.4    Navajas, D.5
  • 63
    • 1542287471 scopus 로고    scopus 로고
    • Laboratory evaluation of 4 brands of endotracheal tube cuff inflator
    • Blanch PB: Laboratory evaluation of 4 brands of endotracheal tube cuff inflator. Respir Care 2004, 49:166-173.
    • (2004) Respir Care , vol.49 , pp. 166-173
    • Blanch, P.B.1
  • 64
    • 78149470999 scopus 로고    scopus 로고
    • Correlations between controlled endotracheal tube cuff pressure and postprocedural complications: A multicenter study
    • Liu J, Zhang X, Gong W, Li S, Wang F, Fu S, Zhang M, Hang Y: Correlations between controlled endotracheal tube cuff pressure and postprocedural complications: a multicenter study. Anesth Analg 2010, 111:1133-1137.
    • (2010) Anesth Analg , vol.111 , pp. 1133-1137
    • Liu, J.1    Zhang, X.2    Gong, W.3    Li, S.4    Wang, F.5    Fu, S.6    Zhang, M.7    Hang, Y.8
  • 65
    • 79952387220 scopus 로고    scopus 로고
    • Evaluation of an intervention to maintain endotracheal tube cuff pressure within therapeutic range
    • quiz 118
    • Lou SM, Su X, Talbert S, Penoyer DA, Kalita S, Jimenez E, Ludy JE, Bennett M: Evaluation of an intervention to maintain endotracheal tube cuff pressure within therapeutic range. Am J Crit Care 2011, 20:109-117. quiz 118.
    • (2011) Am J Crit Care , vol.20 , pp. 109-117
    • Lou, S.M.1    Su, X.2    Talbert, S.3    Penoyer, D.A.4    Kalita, S.5    Jimenez, E.6    Ludy, J.E.7    Bennett, M.8
  • 69
    • 84861791530 scopus 로고    scopus 로고
    • Comparison of two automated endotracheal cuff pressure regulator devices in intubated critically ill patients: Mechanical and electronic
    • Abstract
    • Brisson H, Bouhamed B, Lu Q, Rouby JJ: Comparison of two automated endotracheal cuff pressure regulator devices in intubated critically ill patients: mechanical and electronic. Intensive Care Med 2011, 37(Suppl 1):296. Abstract.
    • (2011) Intensive Care Med , vol.37 , Issue.SUPPL. 1 , pp. 296
    • Brisson, H.1    Bouhamed, B.2    Lu, Q.3    Rouby, J.J.4
  • 70
    • 34249280606 scopus 로고    scopus 로고
    • Automatic control of tracheal tube cuff pressure in ventilated patients in semirecumbent position: A randomized trial
    • Valencia M, Ferrer M, Farre R, Navajas D, Badia JR, Nicolas JM, Torres A: Automatic control of tracheal tube cuff pressure in ventilated patients in semirecumbent position: a randomized trial. Crit Care Med 2007, 35:1543-1549.
    • (2007) Crit Care Med , vol.35 , pp. 1543-1549
    • Valencia, M.1    Ferrer, M.2    Farre, R.3    Navajas, D.4    Badia, J.R.5    Nicolas, J.M.6    Torres, A.7
  • 72
    • 84885023150 scopus 로고    scopus 로고
    • Continuous control of tracheal cuff pressure for the prevention of ventilator-associated pneumonia in critically ill patients: Where is the evidence?
    • Rouzé A, Nseir S: Continuous control of tracheal cuff pressure for the prevention of ventilator-associated pneumonia in critically ill patients: where is the evidence? Curr Opin Crit Care 2013, 19:440-447.
    • (2013) Curr Opin Crit Care , vol.19 , pp. 440-447
    • Rouzé, A.1    Nseir, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.