-
1
-
-
77956640312
-
New endotracheal tubes designed to prevent ventilator-associated pneumonia: Do they make a difference?
-
Deem S, Treggiari MM. New endotracheal tubes designed to prevent ventilator-associated pneumonia: Do they make a difference? Respir Care 2010;55:1046-55.
-
(2010)
Respir Care
, vol.55
, pp. 1046-1055
-
-
Deem, S.1
Treggiari, M.M.2
-
2
-
-
0036924301
-
Epidemiology and outcomes of ventilator-associated pneumonia in a large US database
-
DOI 10.1378/chest.122.6.2115
-
Rello J, Ollendorf DA, Oster G, Vera-Llonch M, Bellm L, Redman R et al. Epidemiology and outcomes of ventilator-associated pneumonia in a large us database. Chest 2002;122:2115-21. (Pubitemid 36051151)
-
(2002)
Chest
, vol.122
, Issue.6
, pp. 2115-2121
-
-
Rello, J.1
Ollendorf, D.A.2
Oster, G.3
Vera-Llonch, M.4
Bellm, L.5
Redman, R.6
Kollef, M.H.7
-
3
-
-
33847396955
-
Prevention measures for ventilator-associated pneumonia: A new focus on the endotracheal tube
-
DOI 10.1097/QCO.0b013e328014daac, PII 0000143220070400000014
-
Ramirez P, Ferrer M, Torres A. Prevention measures for ventilator-associated pneumonia: a new focus on the endotracheal tube. Curr Opin Infect Dis 2007;20:190-7. (Pubitemid 46340803)
-
(2007)
Current Opinion in Infectious Diseases
, vol.20
, Issue.2
, pp. 190-197
-
-
Ramirez, P.1
Ferrer, M.2
Torres, A.3
-
4
-
-
78649330714
-
Variables affecting leakage past endotracheal tube cuffs: A bench study
-
Pitts R, Fisher D, Sulemanji D, Kratohvil J, Jiang Y, Kacmarek R. Variables affecting leakage past endotracheal tube cuffs: A bench study. Intensive Care Med 2010;36:2066-73.
-
(2010)
Intensive Care Med
, vol.36
, pp. 2066-2073
-
-
Pitts, R.1
Fisher, D.2
Sulemanji, D.3
Kratohvil, J.4
Jiang, Y.5
Kacmarek, R.6
-
5
-
-
36849046753
-
Influence of an endotracheal tube with polyurethane cuff and subglottic secretion drainage on pneumonia
-
DOI 10.1164/rccm.200705-761OC
-
Lorente L, Lecuona M, Jimenez A, Mora ML, Sierra A. Influence of an endotracheal tube with polyurethane cuff and subglottic secretion drainage on pneumonia. Am J Respir Crit Care Med 2007;176:1079-83. (Pubitemid 350223753)
-
(2007)
American Journal of Respiratory and Critical Care Medicine
, vol.176
, Issue.11
, pp. 1079-1083
-
-
Lorente, L.1
Lecuona, M.2
Jimenez, A.3
Mora, M.L.4
Sierra, A.5
-
6
-
-
40949155070
-
Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: A pilot study
-
DOI 10.1016/j.jtcvs.2007.08.052, PII S0022522307015760
-
Poelaert J, Depuydt P, De Wolf A, Van de Velde S, Herck I, Blot S. Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: A pilot study. J Thorac Cardiovasc Surg 2008;135:771-6. (Pubitemid 351417923)
-
(2008)
Journal of Thoracic and Cardiovascular Surgery
, vol.135
, Issue.4
, pp. 771-776
-
-
Poelaert, J.1
Depuydt, P.2
De Wolf, A.3
Van De, V.S.4
Herck, I.5
Blot, S.6
-
7
-
-
79953876852
-
A polyurethane cuffed endotracheal tube is associated with decreased rates of ventilator-associated pneumonia
-
Miller MA, Arndt JL, Konkle MA, Chenoweth CE, Iwashyna TJ, Flaherty KR et al. A polyurethane cuffed endotracheal tube is associated with decreased rates of ventilator-associated pneumonia. J Crit Care 2011;26:280-6.
-
(2011)
J Crit Care
, vol.26
, pp. 280-286
-
-
Miller, M.A.1
Arndt, J.L.2
Konkle, M.A.3
Chenoweth, C.E.4
Iwashyna, T.J.5
Flaherty, K.R.6
-
8
-
-
0032814036
-
Prospective evaluation of the Sedation-Agitation Scale for adult critically ill patients
-
DOI 10.1097/00003246-199907000-00022
-
Riker RR, Picard JT, Fraser GL. Prospective evaluation of the Sedation-Agitation Scale for adult critically ill patients. Crit Care Med 1999;27:1325-9. (Pubitemid 29379371)
-
(1999)
Critical Care Medicine
, vol.27
, Issue.7
, pp. 1325-1329
-
-
Riker, R.R.1
Picard, J.T.2
Fraser, G.L.3
-
9
-
-
34547145165
-
G*Power 3: A flexible Statistical power analysis program for the social, behavorial, and biomedical sciences
-
Faul F, Erdfelder E, Lang AG, Buchner A. G*Power 3: A flexible Statistical power analysis program for the social, behavorial, and biomedical sciences. Behav Res Methods 2007;39:175-91.
-
(2007)
Behav Res Methods
, vol.39
, pp. 175-191
-
-
Faul, F.1
Erdfelder, E.2
Lang, A.G.3
Buchner, A.4
-
10
-
-
33644598324
-
A low-volume, low-pressure tracheal tube cuff reduces pulmonary aspiration
-
Young PJ, Pakeerathan S, Blunt MC, Subramanya S. A low-volume, low-pressure tracheal tube cuff reduces pulmonary aspiration. Crit Care Med 2006;34:632-9.
-
(2006)
Crit Care Med
, vol.34
, pp. 632-639
-
-
Young, P.J.1
Pakeerathan, S.2
Blunt, M.C.3
Subramanya, S.4
-
11
-
-
0242677653
-
Fluid leakage past tracheal tube cuffs: Evaluation of the new Microcuff endotracheal tube
-
DOI 10.1007/s00134-003-1933-6
-
Dullenkopf A, Gerber A, Weiss M. Fluid leakage past tracheal tube cuffs: Evaluation of the new microcuff endotracheal tube. Intensive Care Med 2003;29:1849-53. (Pubitemid 37373839)
-
(2003)
Intensive Care Medicine
, vol.29
, Issue.10
, pp. 1849-1853
-
-
Dullenkopf, A.1
Gerber, A.2
Weiss, M.3
-
12
-
-
38549158409
-
Effect of positive expiratory pressure and type of tracheal cuff on the incidence of aspiration in mechanically ventilated patients in an intensive care unit
-
DOI 10.1097/01.CCM.0000297888.82492.31, PII 0000324620080200000006
-
Lucangelo U, Zin WA, Antonaglia V, Petrucci L, Viviani M, Buscema G et al. Effect of positive expiratory pressure and type of tracheal cuff on the incidence of aspiration in mechanically ventilated patients in an intensive care unit. Crit Care Med 2008;36:409-13. (Pubitemid 351158612)
-
(2008)
Critical Care Medicine
, vol.36
, Issue.2
, pp. 409-413
-
-
Lucangelo, U.1
Zin, W.A.2
Antonaglia, V.3
Petrucci, L.4
Viviani, M.5
Buscema, G.6
Borelli, M.7
Berlot, G.8
-
13
-
-
80051494477
-
Comparison of a novel lycra endotracheal tube cuff to standard polyvinyl chloride cuff and polyurethane cuff for fluid leak prevention
-
Kolobow T, Cressoni M, Epp M, Corti I, Cadringher P, Zanella A. Comparison of a novel lycra endotracheal tube cuff to standard polyvinyl chloride cuff and polyurethane cuff for fluid leak prevention. Respir Care 2011;56:1095-9.
-
(2011)
Respir Care
, vol.56
, pp. 1095-1099
-
-
Kolobow, T.1
Cressoni, M.2
Epp, M.3
Corti, I.4
Cadringher, P.5
Zanella, A.6
-
14
-
-
79953827556
-
Mechanical influences on fluid leakage past the tracheal tube cuff in a benchtop model
-
Ouanes I, Lyazidi A, Danin PE, Rana N, Di Bari A, Abroug F et al. Mechanical influences on fluid leakage past the tracheal tube cuff in a benchtop model. Intensive Care Med 2011;37:695-700.
-
(2011)
Intensive Care Med
, vol.37
, pp. 695-700
-
-
Ouanes, I.1
Lyazidi, A.2
Danin, P.E.3
Rana, N.4
Di Bari, A.5
Abroug, F.6
-
15
-
-
77954537962
-
Tracheal fluid leakage in benchtop trials: Comparison of static versus dynamic ventilation model with and without lubrication
-
Dave MH, Koepfer N, Madjdpour C, Frotzler A, Weiss M. Tracheal fluid leakage in benchtop trials: Comparison of static versus dynamic ventilation model with and without lubrication. J Anesth 2010;24:247-52.
-
(2010)
J Anesth
, vol.24
, pp. 247-252
-
-
Dave, M.H.1
Koepfer, N.2
Madjdpour, C.3
Frotzler, A.4
Weiss, M.5
-
16
-
-
79953826042
-
Fluid leakage across tracheal tube cuff, effect of different cuff material, shape, and positive expiratory pressure: A bench-top study
-
Zanella A, Scaravilli V, Isgro S, Milan M, Cressoni M, Patroniti N et al. Fluid leakage across tracheal tube cuff, effect of different cuff material, shape, and positive expiratory pressure: A bench-top study. Intensive Care Med 2011;37:343-7.
-
(2011)
Intensive Care Med
, vol.37
, pp. 343-347
-
-
Zanella, A.1
Scaravilli, V.2
Isgro, S.3
Milan, M.4
Cressoni, M.5
Patroniti, N.6
-
17
-
-
58449129399
-
Rapid pressure compensation by automated cuff pressure controllers worsens sealing in tracheal tubes
-
Weiss M, Doell C, Koepfer N, Madjdpour C, Woitzek K, Bernet V. Rapid pressure compensation by automated cuff pressure controllers worsens sealing in tracheal tubes. Br J Anaesth 2009;102:273-8.
-
(2009)
Br J Anaesth
, vol.102
, pp. 273-278
-
-
Weiss, M.1
Doell, C.2
Koepfer, N.3
Madjdpour, C.4
Woitzek, K.5
Bernet, V.6
|