Volumn 37, Issue 5, 2014, Pages 1216-1223

Quantitative estimation of insulin sensitivity in type 1 diabetic subjects wearing a sensor-augmented insulin pump

Author keywords

[No Author keywords available]

Indexed keywords

GLUCOSE; INSULIN; ANTIDIABETIC AGENT; GLUCOSE BLOOD LEVEL;

EID: 84899052258     PISSN: 01495992     EISSN: 19355548     Source Type: Journal    
DOI: 10.2337/dc13-1120     Document Type: Article
Times cited : (43)

References (24)
  • 5
    • 0034527683 scopus 로고    scopus 로고
    • Insulin sensitivity from meal tolerance tests in normal subjects: A minimal model index
    • DOI 10.1210/jc.85.11.4396
    • Caumo A, Bergman RN, Cobelli C. Insulin sensitivity from meal tolerance tests in normal subjects: a minimal model index. J Clin Endocrinol Metab 2000;85:4396-4402 (Pubitemid 32055404)
    • (2000) Journal of Clinical Endocrinology and Metabolism , vol.85 , Issue.11 , pp. 4396-4402
    • Caumo, A.1    Bergman, R.N.2    Cobelli, C.3
  • 7
    • 0032821965 scopus 로고    scopus 로고
    • Insulin sensitivity indices obtained from oral glucose tolerance testing: Comparison with the euglycemic insulin clamp
    • DOI 10.2337/diacare.22.9.1462
    • Matsuda M, DeFronzo RA. Insulin sensitivity indices obtained from oral glucose tolerance testing: comparison with the euglycemic insulin clamp. Diabetes Care 1999;22:1462-1470 (Pubitemid 29418240)
    • (1999) Diabetes Care , vol.22 , Issue.9 , pp. 1462-1470
    • Matsuda, M.1    DeFronzo, R.A.2
  • 8
    • 33846821782 scopus 로고    scopus 로고
    • The BIGTT test: A novel test for simultaneous measurement of pancreatic β-cell function, insulin sensitivity, and glucose tolerance
    • DOI 10.2337/dc06-1240
    • Hansen T, Drivsholm T, Urhammer SA, et al. The BIGTT test: a novel test for simultaneous measurement of pancreatic β-cell function, insulin sensitivity, and glucose tolerance. Diabetes Care 2007;30:257-262 (Pubitemid 46201651)
    • (2007) Diabetes Care , vol.30 , Issue.2 , pp. 257-262
    • Hansen, T.1    Drivsholm, T.2    Urhammer, S.A.3    Palacios, R.T.4    Volund, A.5    Borch-Johnsen, K.6    Pedersen, O.7
  • 9
    • 84899083109 scopus 로고    scopus 로고
    • Method, system and computer program product for evaluation of insulin sensitivity, insulin/carbohydrate ratio, and insulin correction factors in diabetes from self-monitoring data
    • PCT international patent application PCT/US2008/069416. 8 July
    • Breton MD, Kovatchev BP. Method, system and computer program product for evaluation of insulin sensitivity, insulin/carbohydrate ratio, and insulin correction factors in diabetes from self-monitoring data. PCT international patent application PCT/US2008/069416. 8 July 2008
    • (2008)
    • Breton, M.D.1    Kovatchev, B.P.2
  • 10
    • 84883730627 scopus 로고    scopus 로고
    • Diurnal pattern of insulin action in type 1 diabetes: Implications for a closed-loop system
    • Hinshaw L, Dalla Man C, Nandy DK, et al. Diurnal pattern of insulin action in type 1 diabetes: implications for a closed-loop system. Diabetes 2013;62:2223-2229
    • (2013) Diabetes , vol.62 , pp. 2223-2229
    • Hinshaw, L.1    Dalla Man, C.2    Nandy, D.K.3
  • 11
    • 84873147427 scopus 로고    scopus 로고
    • Evaluating the accuracy and large inaccuracy of two continuous glucose monitoring systems
    • Leelarathna L, Nodale M, Allen JM, et al. Evaluating the accuracy and large inaccuracy of two continuous glucose monitoring systems. Diabetes Technol Ther 2013;15:143-149
    • (2013) Diabetes Technol Ther , vol.15 , pp. 143-149
    • Leelarathna, L.1    Nodale, M.2    Allen, J.M.3
  • 12
    • 65949123793 scopus 로고    scopus 로고
    • Effects of type 2 diabetes on insulin secretion, insulin action, glucose effectiveness, and postprandial glucose metabolism
    • Basu A, Dalla Man C, Basu R, Toffolo G, Cobelli C, Rizza RA. Effects of type 2 diabetes on insulin secretion, insulin action, glucose effectiveness, and postprandial glucose metabolism. Diabetes Care 2009;32:866-872
    • (2009) Diabetes Care , vol.32 , pp. 866-872
    • Basu, A.1    Dalla Man, C.2    Basu, R.3    Toffolo, G.4    Cobelli, C.5    Rizza, R.A.6
  • 13
    • 84861405223 scopus 로고    scopus 로고
    • Enhancing the accuracy of subcutaneous glucose sensors: A real-time deconvolution-based approach
    • Guerra S, Facchinetti A, Sparacino G, Nicolao GD, Cobelli C. Enhancing the accuracy of subcutaneous glucose sensors: a real-time deconvolution-based approach. IEEE Trans Biomed Eng 2012;59:1658-1669
    • (2012) IEEE Trans Biomed Eng , vol.59 , pp. 1658-1669
    • Guerra, S.1    Facchinetti, A.2    Sparacino, G.3    Nicolao, G.D.4    Cobelli, C.5
  • 16
    • 70349631804 scopus 로고    scopus 로고
    • Minimal model assessment of hepatic insulin extraction during an oral test from standard insulin kinetic parameters
    • Campioni M, Toffolo G, Basu R, Rizza RA, Cobelli C. Minimal model assessment of hepatic insulin extraction during an oral test from standard insulin kinetic parameters. Am J Physiol Endocrinol Metab 2009;297:E941-E948
    • (2009) Am J Physiol Endocrinol Metab , vol.297
    • Campioni, M.1    Toffolo, G.2    Basu, R.3    Rizza, R.A.4    Cobelli, C.5
  • 17
    • 84865528549 scopus 로고    scopus 로고
    • Modular closed-loop control of diabetes
    • International Artificial Pancreas (iAP) Study Group
    • Patek SD, Magni L, Dassau E, et al.; International Artificial Pancreas (iAP) Study Group. Modular closed-loop control of diabetes. IEEE Trans Biomed Eng 2012;59:2986-2999
    • (2012) IEEE Trans Biomed Eng , vol.59 , pp. 2986-2999
    • Patek, S.D.1    Magni, L.2    Dassau, E.3
  • 18
    • 77949891806 scopus 로고    scopus 로고
    • Safety constraints in an artificial pancreatic beta cell: An implementation of model predictive control with insulin on board
    • Ellingsen C, Dassau E, Zisser H, et al. Safety constraints in an artificial pancreatic beta cell: an implementation of model predictive control with insulin on board. J Diabetes Sci Tech 2009;3:536-544
    • (2009) J Diabetes Sci Tech , vol.3 , pp. 536-544
    • Ellingsen, C.1    Dassau, E.2    Zisser, H.3
  • 19
    • 33845914748 scopus 로고    scopus 로고
    • A system model of oral glucose absorption: Validation on gold standard data
    • DOI 10.1109/TBME.2006.883792, 10
    • Dalla Man C, Camilleri M, Cobelli C. A system model of oral glucose absorption: validation on gold standard data. IEEE Trans Biomed Eng 2006;53:2472-2478 (Pubitemid 46019534)
    • (2006) IEEE Transactions on Biomedical Engineering , vol.53 , Issue.12 , pp. 2472-2478
    • Dalla, M.C.1    Camilleri, M.2    Cobelli, C.3
  • 20
    • 84899058936 scopus 로고    scopus 로고
    • Estimation of insulin sensitivity from CGM and subcutaneous insulin delivery in type 1 diabetes
    • U.S. patent application US 13/661,755. 26 October
    • Cobelli C, Dalla Man C, Schiavon M, Basu A, Kudva Y. Estimation of insulin sensitivity from CGM and subcutaneous insulin delivery in type 1 diabetes. U.S. patent application US 13/661,755. 26 October 2012
    • (2012)
    • Cobelli, C.1    Dalla Man, C.2    Schiavon, M.3    Basu, A.4    Kudva, Y.5
  • 21
    • 69949146908 scopus 로고    scopus 로고
    • In silico preclinical trials: A proof of concept in closed-loop control of type 1 diabetes
    • Kovatchev BP, Breton M, Man CD, Cobelli C. In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes. J Diabetes Sci Tech 2009;3:44-55
    • (2009) J Diabetes Sci Tech , vol.3 , pp. 44-55
    • Kovatchev, B.P.1    Breton, M.2    Man, C.D.3    Cobelli, C.4
  • 22
    • 77949383313 scopus 로고    scopus 로고
    • STAR 3 randomized controlled trial to compare sensor-augmented insulin pump therapy with multiple daily injections in the treatment of type 1 diabetes: Research design, methods, and baseline characteristics of enrolled subjects
    • Davis SN, Horton ES, Battelino T, Rubin RR, Schulman KA, Tamborlane WV. STAR 3 randomized controlled trial to compare sensor-augmented insulin pump therapy with multiple daily injections in the treatment of type 1 diabetes: research design, methods, and baseline characteristics of enrolled subjects. Diabetes Technol Ther 2010;12:249-255
    • (2010) Diabetes Technol Ther , vol.12 , pp. 249-255
    • Davis, S.N.1    Horton, E.S.2    Battelino, T.3    Rubin, R.R.4    Schulman, K.A.5    Tamborlane, W.V.6
  • 23
    • 84899058949 scopus 로고    scopus 로고
    • A method system and device for assessing insulin sensitivity
    • PCT publication US20080319381. 31 December
    • Yodfat O, Shapira G, Gescheit I. A method system and device for assessing insulin sensitivity. PCT publication US20080319381. 31 December 2008
    • (2008)
    • Yodfat, O.1    Shapira, G.2    Gescheit, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.