Volumn 15, Issue 2, 2013, Pages 143-149

Evaluating the accuracy and large inaccuracy of two continuous glucose monitoring systems

Author keywords

[No Author keywords available]

Indexed keywords

INSULIN;

EID: 84873147427     PISSN: 15209156     EISSN: 15578593     Source Type: Journal    
DOI: 10.1089/dia.2012.0245     Document Type: Article
Times cited : (40)

References (29)
  • 2
    • 78751517198 scopus 로고    scopus 로고
    • Elimination of hypoglycemia from the lives of people affected by diabetes
    • Cryer PE: Elimination of hypoglycemia from the lives of people affected by diabetes. Diabetes 2011;60:24-27
    • (2011) Diabetes , vol.60 , pp. 24-27
    • Cryer, P.E.1
  • 3
    • 79959616082 scopus 로고    scopus 로고
    • Closed-Loop insulin delivery: From bench to clinical practice
    • Hovorka R: Closed-Loop insulin delivery: From bench to clinical practice. Nat Rev Endocrinol 2011;7:385-395
    • (2011) Nat Rev Endocrinol , vol.7 , pp. 385-395
    • Hovorka, R.1
  • 8
    • 48649083317 scopus 로고    scopus 로고
    • Fully automated closed-Loop insulin delivery versus sermautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas
    • Weinzimer SA, Steil GM, Swan KL, Dziura J, Kurtz N, Tamborlane WV: Fully automated closed-Loop insulin delivery versus sermautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Diabetes Care 2008;31:934-939
    • (2008) Diabetes Care , vol.31 , pp. 934-939
    • Weinzimer, S.A.1    Steil, G.M.2    Swan, K.L.3    Dziura, J.4    Kurtz, N.5    Tamborlane, W.V.6
  • 10
    • 77954901769 scopus 로고    scopus 로고
    • MDLogic Artificial Pancreas System: A pilot study in adults with type 1 diabetes
    • Atlas E, Nimri R, Miller S, Grunberg EA, Phillip M: MDLogic Artificial Pancreas System: A pilot study in adults with type 1 diabetes. Diabetes Care 2010;33:1072-1076
    • (2010) Diabetes Care , vol.33 , pp. 1072-1076
    • Atlas, E.1    Nimri, R.2    Miller, S.3    Grunberg, E.A.4    Phillip, M.5
  • 13
    • 77649182178 scopus 로고    scopus 로고
    • Time lag characterization of two continuous glucose monitoring systems
    • Garg SK, Voelmle M, Gottlieb PA: Time lag characterization of two continuous glucose monitoring systems. Diabetes Res Clin Pract 2010;87:348-353
    • (2010) Diabetes Res Clin Pract , vol.87 , pp. 348-353
    • Garg, S.K.1    Voelmle, M.2    Gottlieb, P.A.3
  • 17
    • 79957996738 scopus 로고    scopus 로고
    • FreeStyle Navigator continuous glucose monitoring system with TRUstart algorithm, a 1-hour warm-up time
    • Geoffrey M, Brazg R, Richard W: FreeStyle Navigator continuous glucose monitoring system with TRUstart algorithm, a 1-hour warm-up time. J Diabetes Sci Technol 2011; 5:99-106
    • (2011) J Diabetes Sci Technol , vol.5 , pp. 99-106
    • Geoffrey, M.1    Brazg, R.2    Richard, W.3
  • 18
    • 0023205574 scopus 로고
    • Evaluating clinical accuracy of systems for self-monitoring of blood glucose
    • Clarke W, Cox D, Gonder-Frederick L, Carter W, Pohl S: Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 1987;10:622-628
    • (1987) Diabetes Care , vol.10 , pp. 622-628
    • Clarke, W.1    Cox, D.2    Gonder-Frederick, L.3    Carter, W.4    Pohl, S.5
  • 19
    • 70349240850 scopus 로고    scopus 로고
    • Statistical tools to analyze continuous glucose monitor data
    • Clarke W, Kovatchev B: Statistical tools to analyze continuous glucose monitor data. Diabetes Technol Ther 2009; 11(SUPPL1):S45-S54
    • (2009) Diabetes Technol Ther , vol.11 , Issue.SUPPL. 1
    • Clarke, W.1    Kovatchev, B.2
  • 21
    • 0033855803 scopus 로고    scopus 로고
    • A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose
    • Parkes JL, Slatin SL, Pardo S, Ginsberg BH: A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care 2000;23:1143-1148
    • (2000) Diabetes Care , vol.23 , pp. 1143-1148
    • Parkes, J.L.1    Slatin, S.L.2    Pardo, S.3    Ginsberg, B.H.4
  • 22
    • 34247600583 scopus 로고    scopus 로고
    • Accuracy of the 5-Day FreeStyle Navigator continuous glucose monitoring system: Comparison with frequent laboratory reference measurements
    • Weinstein RL, Schwartz SL, Brazg RL, Bugler JR, Peyser TA, McGarraugh GV: Accuracy of the 5-Day FreeStyle Navigator continuous glucose monitoring system: Comparison with frequent laboratory reference measurements. Diabetes Care 2007;30:1125-1130
    • (2007) Diabetes Care , vol.30 , pp. 1125-1130
    • Weinstein, R.L.1    Schwartz, S.L.2    Brazg, R.L.3    Bugler, J.R.4    Peyser, T.A.5    McGarraugh, G.V.6
  • 23
    • 78650760751 scopus 로고    scopus 로고
    • Comparison of the numerical and clinical accuracy of four continuous glucose monitors
    • Kovatchev B, Anderson S, Heinemann L, Clarke W: Comparison of the numerical and clinical accuracy of four continuous glucose monitors. Diabetes Care 2008;31:1160-1164
    • (2008) Diabetes Care , vol.31 , pp. 1160-1164
    • Kovatchev, B.1    Anderson, S.2    Heinemann, L.3    Clarke, W.4
  • 24
    • 77949879803 scopus 로고    scopus 로고
    • New features and performance of a next-Generation SEVEN-Day continuous glucose monitoring system with short lag time
    • Bailey T, Zisser H, Chang A: New features and performance of a next-Generation SEVEN-Day continuous glucose monitoring system with short lag time. Diabetes Technol Ther 2009;11:749-755
    • (2009) Diabetes Technol Ther , vol.11 , pp. 749-755
    • Bailey, T.1    Zisser, H.2    Chang, A.3
  • 26
    • 77249175519 scopus 로고    scopus 로고
    • Overnight closed-Loop insulin delivery with model predictive control: Assessment of hypoglycemia and hyperglycemia risk using simulation studies
    • Wilinska ME, Budiman ES, Taub MB, Elleri D, Allen JM, Acerini CL, Dunger DB, Hovorka R: Overnight closed-Loop insulin delivery with model predictive control: Assessment of hypoglycemia and hyperglycemia risk using simulation studies. J Diabetes Sci Technol 2009;3:1109-1120
    • (2009) J Diabetes Sci Technol , vol.3 , pp. 1109-1120
    • Wilinska, M.E.1    Budiman, E.S.2    Taub, M.B.3    Elleri, D.4    Allen, J.M.5    Acerini, C.L.6    Dunger, D.B.7    Hovorka, R.8
  • 27
    • 3342981187 scopus 로고    scopus 로고
    • Evaluating the accuracy of continuous glucose-monitoring sensors: Continuous glucose-Error grid analysis illustrated by therasense freestyle navigator data
    • Kovatchev BP, Gonder-Frederick LA, Cox DJ, Clarke WL: Evaluating the accuracy of continuous glucose-monitoring sensors: Continuous glucose-Error grid analysis illustrated by TheraSense Freestyle Navigator data. Diabetes Care 2004;27: 1922-1928
    • (2004) Diabetes Care , vol.27 , pp. 1922-1928
    • Kovatchev, B.P.1    Gonder-Frederick, L.A.2    Cox, D.J.3    Clarke, W.L.4
  • 28
    • 84873151563 scopus 로고    scopus 로고
    • Dexcom G4, a next generation continuous glucose monitoring (CGM) system, demonstrates a strong correlation to self-monitored blood glucose (SMBG) [abstract
    • Price DA, Nakamura K, Kamath A, Boock R: Dexcom G4, a next generation continuous glucose monitoring (CGM) system, demonstrates a strong correlation to self-monitored blood glucose (SMBG) [abstract]. Diabetes 2012;61(SUPPL1):A588
    • (2012) Diabetes , vol.61 , Issue.SUPPL. 1
    • Price, D.A.1    Nakamura, K.2    Kamath, A.3    Boock, R.4
  • 29
    • 84873209657 scopus 로고    scopus 로고
    • Consistent performance of Dexcom G4 when calibrated at different rates-of-change (ROC) [abstract
    • Garcia A, Mahalingam A, Kamath A: Consistent performance of Dexcom G4 when calibrated at different rates-of-change (ROC) [abstract]. Diabetes 2012;61(SUPPL1): A586
    • (2012) Diabetes , vol.61 , Issue.SUPPL. 1
    • Garcia, A.1    Mahalingam, A.2    Kamath, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.