메뉴 건너뛰기




Volumn 9, Issue 4, 2014, Pages

Persistence of microbial contamination on transvaginal ultrasound probes despite low-level disinfection procedure

Author keywords

[No Author keywords available]

Indexed keywords

ALCOHOL; BACTERIAL DNA; CHLORHEXIDINE GLUCONATE; MENTHOL; MIRISTALKONIUM CHLORIDE; PROPYLENE GLYCOL; QUATERNARY AMMONIUM DERIVATIVE; VIRUS DNA; WATER; DISINFECTANT AGENT;

EID: 84898854773     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0093368     Document Type: Article
Times cited : (53)

References (31)
  • 1
    • 0037717068 scopus 로고    scopus 로고
    • Healthcare Infection Control Practices Advisory Committee (HICPAC) Available: Accessed 2013 May 7
    • Rutala WA, Weber DJ, and the Healthcare Infection Control Practices Advisory Committee (HICPAC) (2008) Guideline for disinfection and sterilization in healthcare facilities. Available: http://www.cdc.gov/hicpac/pdf/guidelines/ disinfection-nov-2008.pdf. Accessed 2013 May 7.
    • (2008) Guideline for Disinfection and Sterilization in Healthcare Facilities
    • Rutala, W.A.1    Weber, D.J.2
  • 2
    • 84898864091 scopus 로고    scopus 로고
    • Guidelines for Cleaning and Preparing Endocavitary Ultrasound Transducers Between Patients
    • American Institute of Ultrasound in Medicine
    • American Institute of Ultrasound in Medicine (2003) Guidelines for Cleaning and Preparing Endocavitary Ultrasound Transducers Between Patients. Ultrasound Obstet Gynecol 7: 94.
    • (2003) Ultrasound Obstet Gynecol , vol.7 , pp. 94
  • 3
    • 84866975101 scopus 로고    scopus 로고
    • Decontamination of transvaginal ultrasound probes: Review of national practice and need for national guidelines
    • Gray RA, Williams PL, Dubbins PA, Jenks PJ (2012) Decontamination of transvaginal ultrasound probes: review of national practice and need for national guidelines. Clin Radiol 67: 1069-77.
    • (2012) Clin Radiol , vol.67 , pp. 1069-1077
    • Gray, R.A.1    Williams, P.L.2    Dubbins, P.A.3    Jenks, P.J.4
  • 4
    • 84998080775 scopus 로고    scopus 로고
    • Establishing a protocol for the cleaning and sterilisation/disinfection of ultrasound transducers
    • Backhouse S (2003) Establishing a protocol for the cleaning and sterilisation/disinfection of ultrasound transducers. BMUS Bulletin 11: 37-39.
    • (2003) BMUS Bulletin , vol.11 , pp. 37-39
    • Backhouse, S.1
  • 6
    • 0031966062 scopus 로고    scopus 로고
    • Nosocomial outbreak of Klebsiella pneumoniae producing SHV-5 extended- spectrum β-lactamase, originating from a contaminated ultrasonography coupling gel
    • Gaillot O, Maruéjouls C, Abachin E, Lecuru F, Arlet G, et al. (1998) Nosocomial outbreak of Klebsiella pneumoniae producing SHV-5 extended-Spectrum β-lactamase, originating from a contaminated ultrasonography coupling gel. J Clin Microbiol 36: 1357-60. (Pubitemid 28208027)
    • (1998) Journal of Clinical Microbiology , vol.36 , Issue.5 , pp. 1357-1360
    • Gaillot, O.1    Maruejouls, C.2    Abachin, E.3    Lecuru, F.4    Arlet, G.5    Simonet, M.6    Berche, P.7
  • 7
    • 84873081432 scopus 로고    scopus 로고
    • Infectious risk of endovaginal and transrectal ultrasonography: Systematic review and meta-analysis
    • Leroy S (2013) Infectious risk of endovaginal and transrectal ultrasonography: systematic review and meta-analysis. J Hosp Infect 83: 99-106.
    • (2013) J Hosp Infect , vol.83 , pp. 99-106
    • Leroy, S.1
  • 9
    • 0031752884 scopus 로고    scopus 로고
    • Ultrasound instruments as possible vectors of staphylococcal infection
    • DOI 10.1016/S0195-6701(98)90028-7
    • Ohara T, Itoh Y, Itoh K (1998) Ultrasound instruments as possible vectors of staphylococcal infection. J Hosp Infect 40: 73-7. (Pubitemid 28438975)
    • (1998) Journal of Hospital Infection , vol.40 , Issue.1 , pp. 73-77
    • Ohara, T.1    Itoh, Y.2    Itoh, K.3
  • 12
    • 75949113756 scopus 로고    scopus 로고
    • Evaluation of ultraviolet C for disinfection of endocavitary ultrasound transducers persistently contaminated despite probe covers
    • Kac G, Podglajen I, Si-Mohamed A, Rodi A, Grataloup C, Meyer G (2010) Evaluation of ultraviolet C for disinfection of endocavitary ultrasound transducers persistently contaminated despite probe covers. Infect Control Hosp Epidemiol 31: 165-70.
    • (2010) Infect Control Hosp Epidemiol , vol.31 , pp. 165-170
    • Kac, G.1    Podglajen, I.2    Si-Mohamed, A.3    Rodi, A.4    Grataloup, C.5    Meyer, G.6
  • 13
    • 84878020855 scopus 로고    scopus 로고
    • Transvaginal ultrasound probe contamination by the human papillomavirus in the emergency department
    • Available: Accessed 2013 May 7
    • Ma ST, Yeung AC, Chan PK, Graham CA (2012) Transvaginal ultrasound probe contamination by the human papillomavirus in the emergency department. Emerg Med J. Available: http://emj.bmj.com/content/early/2012/07/02/emermed-2012-201407. long. Accessed 2013 May 7.
    • (2012) Emerg Med J
    • Ma, S.T.1    Yeung, A.C.2    Chan, P.K.3    Graham, C.A.4
  • 14
    • 34548637356 scopus 로고    scopus 로고
    • An investigation of the microbiological contamination of ultrasound equipment
    • Sykes A, Apleby M, Perry J, Gould K (2006) An investigation of the microbiological contamination of ultrasound equipment. Br J Infect Cont 7: 16-20.
    • (2006) Br J Infect Cont , vol.7 , pp. 16-20
    • Sykes, A.1    Apleby, M.2    Perry, J.3    Gould, K.4
  • 15
    • 79957933917 scopus 로고    scopus 로고
    • Evaluation of a new disinfection method for ultrasound probes used for regional anesthesia: Ultraviolet C light
    • Bloc S, Mercadal L, Garnier T, Komly B, Leclerc P, et al.(2011) Evaluation of a new disinfection method for ultrasound probes used for regional anesthesia: ultraviolet C light. J Ultrasound Med. 30: 785-8.
    • (2011) J Ultrasound Med , vol.30 , pp. 785-788
    • Bloc, S.1    Mercadal, L.2    Garnier, T.3    Komly, B.4    Leclerc, P.5
  • 17
    • 0028915024 scopus 로고
    • The use of general primers GP5 and GP6 elongated at their 3′ ends with adjacent highly conserved sequences improves human papillomavirus detection by PCR
    • De Roda Husman AM, Walboomers JMM, van den Brule AJC, Meijer CJLM, Snijders PJF (1995) The use of general primers GP5 and GP6 elongated at their 3′ ends with adjacent highly conserved sequences improves human papillomavirus detection by PCR. J Gen Virol 76: 1057-62.
    • (1995) J Gen Virol , vol.76 , pp. 1057-1062
    • De Roda Husman, A.M.1    Walboomers, J.M.M.2    Van Den Brule, A.J.C.3    Meijer, C.J.L.M.4    Snijders, P.J.F.5
  • 18
    • 1542443907 scopus 로고    scopus 로고
    • Detection of Chlamydia trachomatis in endocervical smears of sexually active women in Manaus-AM, Brazil, by PCR
    • Santos C, Teixeira F, Vicente A, Astolfi-Filho S (2003) Detection of Chlamydia trachomatis in endocervical smears of sexually active women in Manaus-AM, Brazil, by PCR. Braz J Infect Dis 7: 91-5.
    • (2003) Braz J Infect Dis , vol.7 , pp. 91-95
    • Santos, C.1    Teixeira, F.2    Vicente, A.3    Astolfi-Filho, S.4
  • 19
    • 0026740583 scopus 로고
    • Genus- and species-specific identification of Mycoplasmas by 16S rRNA amplification
    • Author's correction (1993) in Appl Environ Microbiol 59: 655
    • Van Kuppeveld FJM, van der Logt JTM, Angulo AF, van Zoest MJ, Quint WGV, et al. (1992) Genus- and species-specific identification of Mycoplasmas by 16S rRNA amplification. Appl Environ Microbiol 58:2606-15. Author's correction (1993) in Appl Environ Microbiol 59: 655.
    • (1992) Appl Environ Microbiol , vol.58 , pp. 2606-2615
    • Van Kuppeveld, F.J.M.1    Van Der Logt, J.T.M.2    Angulo, A.F.3    Van Zoest, M.J.4    Quint, W.G.V.5
  • 21
    • 84868275942 scopus 로고    scopus 로고
    • A review of methods for detect human papillomavirus infection
    • Abreu, et al. Virology Journal 2012, 9: 262. Available: Accessed 2013 May 7
    • Abreu AL, Souza RP, Gimenes F, Consolaro ME (2012) A review of methods for detect human papillomavirus infection Virol J 9: 262 Abreu, et al. Virology Journal 2012, 9: 262. Available: http://www.virologyj.com/content/9/1/262. Accessed 2013 May 7.
    • (2012) Virol J , vol.9 , pp. 262
    • Abreu, A.L.1    Souza, R.P.2    Gimenes, F.3    Consolaro, M.E.4
  • 22
    • 79958067825 scopus 로고    scopus 로고
    • Mycoplasma genitalium: An emerging cause of sexually transmitted disease in women
    • doi: 10.1371/journal.ppat.1001324
    • Mc Gowin CL, Anderson-Smits C (2011) Mycoplasma genitalium: an emerging cause of sexually transmitted disease in women. PLoS Pathog 7(5): e1001324. doi: 10.1371/journal.ppat.1001324.
    • (2011) PLoS Pathog , vol.7 , Issue.5
    • Mc Gowin, C.L.1    Anderson-Smits, C.2
  • 23
    • 0344013533 scopus 로고    scopus 로고
    • Genital mycoplasmas
    • Judlin F (2003) Genital mycoplasmas. Gynecol Obstet Fertil 31: 054-9.
    • (2003) Gynecol Obstet Fertil , vol.31 , pp. 054-059
    • Judlin, F.1
  • 25
    • 84876182365 scopus 로고    scopus 로고
    • Ultrasound probes as a possible vector of bacterial transmission
    • Koibuchi H, Kotani K, Taniguchi N (2013) Ultrasound probes as a possible vector of bacterial transmission. Med Ultrason 15: 41-44.
    • (2013) Med Ultrason , vol.15 , pp. 41-44
    • Koibuchi, H.1    Kotani, K.2    Taniguchi, N.3
  • 26
    • 34247565518 scopus 로고    scopus 로고
    • Outbreak of Pseudomonas aeruginosa Infections After Transrectal Ultrasound-Guided Prostate Biopsy
    • DOI 10.1016/j.urology.2007.01.047, PII S0090429507001100
    • Gillespie JL, Arnold KE, Noble-Wang J, Jensen B, Arduino M, et al. (2007) Outbreak of Pseudomonas aeruginosa infections after transrectal ultrasound-guided prostate biopsy. Urology 69: 912-4. (Pubitemid 46670230)
    • (2007) Urology , vol.69 , Issue.5 , pp. 912-914
    • Gillespie, J.L.1    Arnold, K.E.2    Noble-Wang, J.3    Jensen, B.4    Arduino, M.5    Hageman, J.6    Srinivasan, A.7
  • 27
    • 0034769124 scopus 로고    scopus 로고
    • Multiresistant Pseudomonas aeruginosa outbreak associated with contaminated transrectal ultrasound [4]
    • DOI 10.1053/jhin.2001.1056
    • Paz A, Bauer H, Potasman I (2001) Multiresistant Pseudomonas aeruginosa associated with contaminated transrectal ultrasound. J Hosp Infect 49: 148-9. (Pubitemid 32982693)
    • (2001) Journal of Hospital Infection , vol.49 , Issue.2 , pp. 148-149
    • Paz, A.1    Bauer, H.2    Potasman, I.3
  • 29
    • 77953692434 scopus 로고    scopus 로고
    • Burkholderia cepacia infection of the prostate caused by inoculation of contaminated ultrasound gel during tranrectal biopsy of the prostate
    • Organ M, Grantmyre J, Hutchinson J (2010) Burkholderia cepacia infection of the prostate caused by inoculation of contaminated ultrasound gel during tranrectal biopsy of the prostate. Can Urol Assoc J 4: E58-E60.
    • (2010) Can Urol Assoc J , vol.4
    • Organ, M.1    Grantmyre, J.2    Hutchinson, J.3
  • 30
    • 78649982094 scopus 로고    scopus 로고
    • An outbreak of Achromobacter xylosoxidans associated with ultrasound gel during transrectal ultrasound guided prostate biopsy
    • Olshtain-Pops K, Block C, Temper V, Hidalgo-Grass C, et al. (2011) An outbreak of Achromobacter xylosoxidans associated with ultrasound gel during transrectal ultrasound guided prostate biopsy. J Urol 185: 144-7.
    • (2011) J Urol , vol.185 , pp. 144-147
    • Olshtain-Pops, K.1    Block, C.2    Temper, V.3    Hidalgo-Grass, C.4
  • 31
    • 84879664990 scopus 로고    scopus 로고
    • Infectious complications following transrectal ultrasound-guided prostate biopsy: New challenges in the era of multidrug-resistant Escherichia coli
    • In press
    • Williamson DA, Barrett LK, Rogers BA, Freeman JT, Hadway P, et al. (2013) Infectious complications following transrectal ultrasound-guided prostate biopsy: new challenges in the era of multidrug-resistant Escherichia coli. Clin Infect Dis. In press.
    • (2013) Clin Infect Dis
    • Williamson, D.A.1    Barrett, L.K.2    Rogers, B.A.3    Freeman, J.T.4    Hadway, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.