메뉴 건너뛰기




Volumn 20, Issue 6, 2013, Pages 2043-2051

Robust measurement, monitoring and analysis of partial discharges in transformers and other HV apparatus

Author keywords

Acoustical; High voltage insulation; IEC 60270; Noise rejection; On line monitoring; On site diagnostics; Partial discharge; Separation; UHF

Indexed keywords

ACOUSTIC NOISE; ACOUSTICS; PATTERN RECOGNITION; RISK ASSESSMENT; SEPARATION; SOURCE SEPARATION; VOLTAGE MEASUREMENT;

EID: 84898430903     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2013.6678852     Document Type: Article
Times cited : (27)

References (24)
  • 2
    • 65949097315 scopus 로고    scopus 로고
    • IEEE Guide for partial discharge testing of shielded power cable systems in a field environment
    • IEEE 400.3, Inc. New York, USA
    • IEEE 400.3 "IEEE Guide for partial discharge testing of shielded power cable systems in a field environment", The Institute of Electrical and Electronics Engineers, Inc. New York, USA, 2006.
    • (2006) The Institute of Electrical and Electronics Engineers
  • 4
    • 84898443795 scopus 로고    scopus 로고
    • Recommended practice for partial discharge measurement in liquid-filled power transformers and shunt reactors
    • IEEE C57.113, New York, USA
    • IEEE C57.113 "Recommended Practice for partial discharge measurement in liquid-filled power transformers and shunt reactors", IEEE Inc., New York, USA, 2010.
    • (2010) IEEE Inc.
  • 5
    • 84898472777 scopus 로고    scopus 로고
    • Modern de-noising strategies for PD measurements on transformers under challenging onsite conditions
    • Joint Colloquium, Paper PS1-O- 14, Kyoto, Japan
    • A. Kraetge, K. Rethmeier, S. Hoek and M. Krueger "Modern de-noising strategies for PD measurements on transformers under challenging onsite conditions" Cigré SC A2 and D1, Joint Colloquium, Paper PS1-O- 14, Kyoto, Japan, 2011.
    • (2011) Cigré SC A2 and D1
    • Kraetge, A.1    Rethmeier, K.2    Hoek, S.3    Krueger, M.4
  • 6
  • 7
    • 77950574017 scopus 로고    scopus 로고
    • Phase-resolved rise-time-based discrimination of partial discharges
    • M. Florkowski and B. Florkowska "Phase-resolved rise-time-based discrimination of partial discharges," IET Generation, Transmission & Distribution, Vol.3, No.1, pp.115-124, 2009.
    • (2009) IET Generation, Transmission & Distribution , vol.3 , Issue.1 , pp. 115-124
    • Florkowski, M.1    Florkowska, B.2
  • 9
    • 80052724797 scopus 로고    scopus 로고
    • Experience with UHF partial discharge detection and location in power transformers
    • M.D. Judd "Experience with UHF partial discharge detection and location in power transformers," IEEE Electr. Insul. Conf. (EIC), pp. 201-205, 2011.
    • (2011) IEEE Electr. Insul. Conf. (EIC) , pp. 201-205
    • Judd, M.D.1
  • 11
    • 84930594523 scopus 로고    scopus 로고
    • Improved noise suppression by real-time pulse-waveform analysis of PD pulses and pulse-shaped disturbances
    • Cape Town, South Africa, Paper No. A-57
    • K. Rethmeier, A. Obralic, A. Kraetge, M. Krüger, W. Kalkner and R. Plath "Improved Noise Suppression by real-time pulse-waveform analysis of PD pulses and pulse-shaped disturbances", Int'l. Sympos. on High Voltage Eng. (ISH), Cape Town, South Africa, Paper No. A-57, 2009.
    • (2009) Int'L. Sympos. on High Voltage Eng. (ISH)
    • Rethmeier, K.1    Obralic, A.2    Kraetge, A.3    Krüger, M.4    Kalkner, W.5    Plath, R.6
  • 13
    • 77957345101 scopus 로고    scopus 로고
    • Advanced approach for automatic PRPD pattern recognition in monitoring of HV assets
    • Paper No. 050, San Diego, USA
    • A. Belkov, W. Koltunowicz, A. Obralic and R. Plath "Advanced Approach for Automatic PRPD Pattern Recognition in Monitoring of HV Assets", IEEE Int'l. Sympos. Electr. Insul. (ISEI), Paper No. 050, San Diego, USA, 2010.
    • (2010) IEEE int'L. Sympos. Electr. Insul. (ISEI)
    • Belkov, A.1    Koltunowicz, W.2    Obralic, A.3    Plath, R.4
  • 14
    • 84886022588 scopus 로고    scopus 로고
    • IEEE guide for the detection and location of acoustic emissions from partial discharges in oil-immersed power transformers and reactors
    • C57.127 (2007), New York, USA
    • C57.127 (2007) "IEEE Guide for the Detection and Location of Acoustic Emissions from Partial Discharges in Oil-Immersed Power Transformers and Reactors", IEEE Inc. New York, USA, 2007
    • (2007) IEEE Inc.
  • 15
    • 84898437303 scopus 로고
    • Parameters affecting the velocity of sound in transformer oil
    • DOI: 10.1109/MPER.1984.5526050 (1984)
    • E. Howells and E.T. Norton, "Parameters affecting the velocity of sound in transformer oil" IEEE Trans. Power App. Syst., DOI: 10.1109/MPER.1984.5526050 (1984) Vol. 5, No. 5, pp. 34-43, 1984
    • (1984) IEEE Trans. Power App. Syst. , vol.5 , Issue.5 , pp. 34-43
    • Howells, E.1    Norton, E.T.2
  • 16
    • 84945715370 scopus 로고
    • Partial discharge - part XIV: Acoustic partial discharge detection - practical application
    • L.E. Lundgaard, "Partial Discharge - Part XIV: Acoustic Partial Discharge Detection - Practical Application", IEEE Electr. Insul. Mag., Vol. 8, No.5, pp. 34-43, 1992.
    • (1992) IEEE Electr. Insul. Mag. , vol.8 , Issue.5 , pp. 34-43
    • Lundgaard, L.E.1
  • 17
    • 0342697882 scopus 로고    scopus 로고
    • Schallemissionsquellen automatisch lokalisieren
    • Carl Hanser Verlag, München, Germany
    • C.U. Große and H.-W. Reinhardt, "Schallemissionsquellen automatisch lokalisieren" J. MP: Materialprüfung, Vol. 41, pp.342, Carl Hanser Verlag, München, Germany, 1999
    • (1999) J. MP: Materialprüfung , vol.41 , pp. 342
    • Große, C.U.1    Reinhardt, H.-W.2
  • 20
    • 84859295093 scopus 로고    scopus 로고
    • Ultra-wide bandwidth measurement of partial discharge current pulses in SF6
    • DOI: 10.1088/0022-3727/45/16/165203, Bristol, UK
    • A.J. Reid and M.D. Judd, "Ultra-wide bandwidth measurement of partial discharge current pulses in SF6"; J. Phys. D: Appl. Phys., Vol 45, No. 16, DOI: 10.1088/0022-3727/45/16/165203, Bristol, UK, 2012.
    • (2012) J. Phys. D: Appl. Phys. , vol.45 , Issue.16
    • Reid, A.J.1    Judd, M.D.2
  • 23
    • 84898447859 scopus 로고    scopus 로고
    • Modern denoising strategies for PD measurements on transformers under challenging on-site conditions
    • Japan, Paper PS1-O-14
    • A. Kraetge, K. Rethmeier, S.M. Hoek and M. Krueger, "Modern denoising strategies for PD measurements on transformers under challenging on-site conditions", CIGRE SC A2 and D1 Colloquium Kyoto, Japan, Paper PS1-O-14, 2001.
    • (2001) CIGRE SC A2 and D1 Colloquium Kyoto
    • Kraetge, A.1    Rethmeier, K.2    Hoek, S.M.3    Krueger, M.4
  • 24
    • 84898464949 scopus 로고    scopus 로고
    • High voltage test techniques - measurement of partial discharges by electromagnetic and acoustic methods
    • 42/309/CD: IEC 62478/Ed1
    • 42/309/CD: IEC 62478/Ed1: "High Voltage Test Techniques - Measurement of Partial Discharges by Electromagnetic and Acoustic Methods" Proposed Horizontal Standard
    • Proposed Horizontal Standard


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.