메뉴 건너뛰기




Volumn , Issue , 2011, Pages 201-205

Experience with UHF partial discharge detection and location in power transformers

Author keywords

condition monitoring; fault location; partial discharge; sensors; transformers; UHF

Indexed keywords

FARADAY CAGE; GAS INSULATED EQUIPMENT; INTERNAL STRUCTURE; LINE OF SIGHT; MODELING TECHNIQUE; ONLINE MONITORING; PARTIAL DISCHARGE DETECTION; SPATIAL RESOLUTION; THREE DIMENSIONS; TIME-DIFFERENCES; TIME-OF-FLIGHT METHOD; UHF; UHF PD-DETECTION; ULTRA-HIGH FREQUENCY;

EID: 80052724797     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EIC.2011.5996146     Document Type: Conference Paper
Times cited : (37)

References (12)
  • 2
    • 0032121519 scopus 로고    scopus 로고
    • The application of ultra-high-frequency partial discharge measurements to gas-insulated substations
    • July
    • R. Kurrer and K. Feser, "The application of ultra-high-frequency partial discharge measurements to gas-insulated substations", IEEE Trans. Power Delivery, Vol. 13, No. 3, pp. 777-782, July 1998.
    • (1998) IEEE Trans. Power Delivery , vol.13 , Issue.3 , pp. 777-782
    • Kurrer, R.1    Feser, K.2
  • 3
    • 80052722235 scopus 로고    scopus 로고
    • CIGRE Task Force 15/33.03.05, Partial discharge detection system for GIS: Sensitivity verification for the UHF method and the acoustic method, April
    • CIGRE Task Force 15/33.03.05, "Partial discharge detection system for GIS: Sensitivity verification for the UHF method and the acoustic method", Electra, No. 183, pp. 74-87, April 1999.
    • (1999) Electra , Issue.183 , pp. 74-87
  • 6
    • 0036759963 scopus 로고    scopus 로고
    • Recognition of discharge sources using UHF PD signatures
    • Sep/Oct
    • K. Raja, F. Devaux and S. Lelaidier, "Recognition of discharge sources using UHF PD signatures", IEEE Electrical Insulation Magazine, Vol. 18, No. 5, pp. 8-14, Sep/Oct 2002.
    • (2002) IEEE Electrical Insulation Magazine , vol.18 , Issue.5 , pp. 8-14
    • Raja, K.1    Devaux, F.2    Lelaidier, S.3
  • 7
    • 17644409075 scopus 로고    scopus 로고
    • Partial discharge monitoring for power transformers using UHF sensors Part 2: Field Experience
    • May/June
    • M. D. Judd, L. Yang and I. B. B. Hunter, "Partial discharge monitoring for power transformers using UHF sensors Part 2: Field Experience", IEEE Insulation Magazine, Vol. 21, No. 3, pp. 5-13, May/June 2005.
    • (2005) IEEE Insulation Magazine , vol.21 , Issue.3 , pp. 5-13
    • Judd, M.D.1    Yang, L.2    Hunter, I.B.B.3
  • 8
    • 81355141861 scopus 로고    scopus 로고
    • Life management techniques for power transformers
    • CIGRE WG A2.18
    • CIGRE WG A2.18, "Life Management Techniques for Power Transformers", CIGRE (Paris) Technical Brochure 227, 2003.
    • (2003) CIGRE (Paris) Technical Brochure , vol.227
  • 9
    • 80052712121 scopus 로고    scopus 로고
    • Recommendations for condition monitoring and condition assessment facilities for transformers
    • CIGRE WG A2.27
    • CIGRE WG A2.27, "Recommendations for condition monitoring and condition assessment facilities for transformers", CIGRE (Paris) Technical Brochure 343, 2008.
    • (2008) CIGRE (Paris) Technical Brochure , vol.343
  • 11
    • 17744364920 scopus 로고    scopus 로고
    • Propagation characteristics of UHF signals in transformers for locating partial discharge sources
    • August
    • L. Yang and M. D. Judd, "Propagation characteristics of UHF signals in transformers for locating partial discharge sources", Proc. 13th Int. Symp. on High Voltage Engineering (Delft), August 2003.
    • (2003) Proc. 13th Int. Symp. on High Voltage Engineering (Delft)
    • Yang, L.1    Judd, M.D.2
  • 12
    • 80052769775 scopus 로고    scopus 로고
    • www.youtube.com/HFDiagnostics


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.