메뉴 건너뛰기




Volumn 9, Issue 3, 2014, Pages

Rapid parametric mapping of the longitudinal relaxation time T1 using two-dimensional variable flip angle magnetic resonance imaging at 1.5 Tesla, 3 Tesla, and 7 Tesla

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BRAIN MAPPING; CASE REPORT; COMPARATIVE STUDY; CONTROLLED STUDY; FEASIBILITY STUDY; FEMALE; HUMAN; IMAGE ANALYSIS; MAGNETIC FIELD; MALE; MULTIPLE SCLEROSIS; NEUROIMAGING; NUCLEAR MAGNETIC RESONANCE IMAGING; PARAMETRIC TEST; RELAXATION TIME; SIMULATION; TWO DIMENSIONAL VARIABLE FLIP ANGLE NUCLEAR MAGNETIC RESONANCE IMAGING; BRAIN; CYTOLOGY; IMAGE PROCESSING; IMAGE QUALITY; MIDDLE AGED; MONTE CARLO METHOD; PATHOLOGY; PROCEDURES; TIME;

EID: 84897988542     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0091318     Document Type: Article
Times cited : (41)

References (45)
  • 1
    • 79952501096 scopus 로고    scopus 로고
    • Diagnostic criteria for multiple sclerosis: 2010 revisions to the McDonald criteria
    • Polman CH, Reingold SC, Banwell B, Clanet M, Cohen JA, et al. (2011) Diagnostic criteria for multiple sclerosis: 2010 revisions to the McDonald criteria. Ann Neurol 69: 292-302.
    • (2011) Ann Neurol , vol.69 , pp. 292-302
    • Polman, C.H.1    Reingold, S.C.2    Banwell, B.3    Clanet, M.4    Cohen, J.A.5
  • 2
    • 33750579981 scopus 로고    scopus 로고
    • Multiple sclerosis: New insights and trends
    • Inglese M (2006) Multiple sclerosis: new insights and trends. AJNR Am J Neuroradiol 27: 954-957.
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 954-957
    • Inglese, M.1
  • 3
    • 33747423677 scopus 로고    scopus 로고
    • Multiple sclerosis: The role of MR imaging
    • Ge Y (2006) Multiple sclerosis: the role of MR imaging. AJNR Am J Neuroradiol 27: 1165-1176.
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 1165-1176
    • Ge, Y.1
  • 4
    • 84863425466 scopus 로고    scopus 로고
    • Refining the mismatch concept in acute stroke: Lessons learned from PET and MRI
    • Sobesky J (2012) Refining the mismatch concept in acute stroke: lessons learned from PET and MRI. J Cereb Blood Flow Metab 32: 1416-1425.
    • (2012) J Cereb Blood Flow Metab , vol.32 , pp. 1416-1425
    • Sobesky, J.1
  • 5
    • 84880391350 scopus 로고    scopus 로고
    • Neuroimaging standards for research into small vessel disease and its contribution to ageing and neurodegeneration
    • Wardlaw JM, Smith EE, Biessels GJ, Cordonnier C, Fazekas F, et al. (2013) Neuroimaging standards for research into small vessel disease and its contribution to ageing and neurodegeneration. Lancet Neurol 12: 822-838.
    • (2013) Lancet Neurol , vol.12 , pp. 822-838
    • Wardlaw, J.M.1    Smith, E.E.2    Biessels, G.J.3    Cordonnier, C.4    Fazekas, F.5
  • 6
    • 84878566112 scopus 로고    scopus 로고
    • Clinical application of multi-contrast 7-T MR imaging in multiple sclerosis: Increased lesion detection compared to 3 T confined to grey matter
    • de Graaf WL, Kilsdonk ID, Lopez-Soriano A, Zwanenburg JJ, Visser F, et al. (2013) Clinical application of multi-contrast 7-T MR imaging in multiple sclerosis: increased lesion detection compared to 3 T confined to grey matter. Eur Radiol 23: 528-540.
    • (2013) Eur Radiol , vol.23 , pp. 528-540
    • De Graaf, W.L.1    Kilsdonk, I.D.2    Lopez-Soriano, A.3    Zwanenburg, J.J.4    Visser, F.5
  • 7
    • 84865584896 scopus 로고    scopus 로고
    • Multiple sclerosis lesions and irreversible brain tissue damage: A comparative ultrahigh-field strength magnetic resonance imaging study
    • Sinnecker T, Mittelstaedt P, Dorr J, Pfueller CF, Harms L, et al. (2012) Multiple sclerosis lesions and irreversible brain tissue damage: a comparative ultrahigh-field strength magnetic resonance imaging study. Arch Neurol 69: 739-745.
    • (2012) Arch Neurol , vol.69 , pp. 739-745
    • Sinnecker, T.1    Mittelstaedt, P.2    Dorr, J.3    Pfueller, C.F.4    Harms, L.5
  • 8
    • 47049090970 scopus 로고    scopus 로고
    • Demonstrating the perivascular distribution of MS lesions in vivo with 7-Tesla MRI
    • Tallantyre EC, Brookes MJ, Dixon JE, Morgan PS, Evangelou N, et al. (2008) Demonstrating the perivascular distribution of MS lesions in vivo with 7-Tesla MRI. Neurology 70: 2076-2078.
    • (2008) Neurology , vol.70 , pp. 2076-2078
    • Tallantyre, E.C.1    Brookes, M.J.2    Dixon, J.E.3    Morgan, P.S.4    Evangelou, N.5
  • 9
    • 84866112627 scopus 로고    scopus 로고
    • Distinct lesion morphology at 7-T MRI differentiates neuromyelitis optica from multiple sclerosis
    • Sinnecker T, Dorr J, Pfueller CF, Harms L, Ruprecht K, et al. (2012) Distinct lesion morphology at 7-T MRI differentiates neuromyelitis optica from multiple sclerosis. Neurology 79: 708-714.
    • (2012) Neurology , vol.79 , pp. 708-714
    • Sinnecker, T.1    Dorr, J.2    Pfueller, C.F.3    Harms, L.4    Ruprecht, K.5
  • 10
    • 84868007033 scopus 로고    scopus 로고
    • Lesion morphology at 7 Tesla MRI differentiates Susac syndrome from multiple sclerosis
    • Wuerfel J, Sinnecker T, Ringelstein EB, Jarius S, Schwindt W, et al. (2012) Lesion morphology at 7 Tesla MRI differentiates Susac syndrome from multiple sclerosis. Mult Scler 18: 1592-1599.
    • (2012) Mult Scler , vol.18 , pp. 1592-1599
    • Wuerfel, J.1    Sinnecker, T.2    Ringelstein, E.B.3    Jarius, S.4    Schwindt, W.5
  • 13
    • 0026571435 scopus 로고
    • MP RAGE: A threedimensional, T1-weighted, gradient-echo sequence - Initial experience in the brain
    • Brant-Zawadzki M, Gillan GD, Nitz WR (1992) MP RAGE: a threedimensional, T1-weighted, gradient-echo sequence - initial experience in the brain. Radiology 182: 769-775.
    • (1992) Radiology , vol.182 , pp. 769-775
    • Brant-Zawadzki, M.1    Gillan, G.D.2    Nitz, W.R.3
  • 14
    • 0028558724 scopus 로고
    • Technical note: Use of a double inversion recovery pulse sequence to image selectively grey or white brain matter
    • Redpath TW, Smith FW (1994) Technical note: use of a double inversion recovery pulse sequence to image selectively grey or white brain matter. Br J Radiol 67: 1258-1263.
    • (1994) Br J Radiol , vol.67 , pp. 1258-1263
    • Redpath, T.W.1    Smith, F.W.2
  • 17
    • 84890100659 scopus 로고    scopus 로고
    • Within-lesion differences in quantitative MRI parameters predict contrast enhancement in multiple sclerosis
    • Jurcoane A, Wagner M, Schmidt C, Mayer C, Gracien RM, et al. (2013) Within-lesion differences in quantitative MRI parameters predict contrast enhancement in multiple sclerosis. J Magn Reson Imaging.
    • (2013) J Magn Reson Imaging
    • Jurcoane, A.1    Wagner, M.2    Schmidt, C.3    Mayer, C.4    Gracien, R.M.5
  • 18
    • 0036040136 scopus 로고    scopus 로고
    • White matter and lesion T1 relaxation times increase in parallel and correlate with disability in multiple sclerosis
    • DOI 10.1007/s00415-002-0837-7
    • Parry A, Clare S, Jenkinson M, Smith S, Palace J, et al. (2002) White matter and lesion T1 relaxation times increase in parallel and correlate with disability in multiple sclerosis. J Neurol 249: 1279-1286. (Pubitemid 35025108)
    • (2002) Journal of Neurology , vol.249 , Issue.9 , pp. 1279-1286
    • Parry, A.1    Clare, S.2    Jenkinson, M.3    Smith, S.4    Palace, J.5    Matthews, P.M.6
  • 19
    • 0013367398 scopus 로고
    • Driven-equilibrium single-pulse observation of T1 relaxation. A re-evaluation of a rapid 'new' method for determining NMR spin-lattice relaxation times
    • Homer J, Beevers M (1985) Driven-equilibrium single-pulse observation of T1 relaxation. A re-evaluation of a rapid 'new' method for determining NMR spin-lattice relaxation times. J Magn Reson 63: 287-297.
    • (1985) J Magn Reson , vol.63 , pp. 287-297
    • Homer, J.1    Beevers, M.2
  • 21
    • 35148865818 scopus 로고    scopus 로고
    • High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI)
    • Deoni SC (2007) High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI). J Magn Reson Imaging 26: 1106-1111.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 1106-1111
    • Deoni, S.C.1
  • 22
    • 0035036729 scopus 로고    scopus 로고
    • 1 measurement in the presence of non-ideal RF pulse shape and RF field nonuniformity
    • DOI 10.1002/mrm.1112
    • Parker GJ, Barker GJ, Tofts PS (2001) Accurate multislice gradient echo T(1) measurement in the presence of non-ideal RF pulse shape and RF field nonuniformity. Magn Reson Med 45: 838-845. (Pubitemid 32402026)
    • (2001) Magnetic Resonance in Medicine , vol.45 , Issue.5 , pp. 838-845
    • Parker, G.J.M.1    Barker, G.J.2    Tofts, P.S.3
  • 24
    • 0023216172 scopus 로고
    • Rapid calculation of T1 using variable flip angle gradient refocused imaging
    • DOI 10.1016/0730-725X(87)90021-X
    • Fram EK, Herfkens RJ, Johnson GA, Glover GH, Karis JP, et al. (1987) Rapid calculation of T1 using variable flip angle gradient refocused imaging. Magn Reson Imaging 5: 201-208. (Pubitemid 17133355)
    • (1987) Magnetic Resonance Imaging , vol.5 , Issue.3 , pp. 201-208
    • Fram, E.K.1    Herfkens, R.J.2    Johnson, G.A.3
  • 26
    • 0034759242 scopus 로고    scopus 로고
    • Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI
    • DOI 10.1002/mrm.1278
    • Sled JG, Pike GB (2001) Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI. Magn Reson Med 46: 923-931. (Pubitemid 33019916)
    • (2001) Magnetic Resonance in Medicine , vol.46 , Issue.5 , pp. 923-931
    • Sled, J.G.1    Bruce, P.G.2
  • 30
    • 0035157986 scopus 로고    scopus 로고
    • Interregional variation of longitudinal relaxation rates in human brain at 3.0 T: Relation to estimated iron and water contents
    • DOI 10.1002/1522-2594(200101)45:1<71::AID-MRM1011
    • Gelman N, Ewing JR, Gorell JM, Spickler EM, Solomon EG (2001) Interregional variation of longitudinal relaxation rates in human brain at 3.0 T: relation to estimated iron and water contents. Magn Reson Med 45: 71-79. (Pubitemid 32044267)
    • (2001) Magnetic Resonance in Medicine , vol.45 , Issue.1 , pp. 71-79
    • Gelman, N.1    Ewing, J.R.2    Gorell, J.M.3    Spickler, E.M.4    Solomon, E.G.5
  • 31
    • 0345167988 scopus 로고    scopus 로고
    • Comparison of Longitudinal Metabolite Relaxation Times in Different Regions of the Human Brain at 1.5 and 3 Tesla
    • DOI 10.1002/mrm.10640
    • Ethofer T, Mader I, Seeger U, Helms G, Erb M, et al. (2003) Comparison of longitudinal metabolite relaxation times in different regions of the human brain at 1.5 and 3 Tesla. Magn Reson Med 50: 1296-1301. (Pubitemid 37494031)
    • (2003) Magnetic Resonance in Medicine , vol.50 , Issue.6 , pp. 1296-1301
    • Ethofer, T.1    Mader, I.2    Seeger, U.3    Helms, G.4    Erb, M.5    Grodd, W.6    Ludolph, A.7    Klose, U.8
  • 33
    • 84874586472 scopus 로고    scopus 로고
    • Characterization of phase-based methods used for transmission field uniformity mapping: A magnetic resonance study at 3.0 T and 7.0 T
    • Carinci F, Santoro D, von Samson-Himmelstjerna F, Lindel TD, Dieringer MA, et al. (2013) Characterization of phase-based methods used for transmission field uniformity mapping: a magnetic resonance study at 3.0 T and 7.0 T. PLoS One 8: e57982.
    • (2013) PLoS One , vol.8
    • Carinci, F.1    Santoro, D.2    Von Samson-Himmelstjerna, F.3    Lindel, T.D.4    Dieringer, M.A.5
  • 34
    • 0025832805 scopus 로고
    • Rapid in vivo proton shimming
    • Schneider E, Glover G (1991) Rapid in vivo proton shimming. Magn Reson Med 18: 335-347.
    • (1991) Magn Reson Med , vol.18 , pp. 335-347
    • Schneider, E.1    Glover, G.2
  • 36
    • 0345742631 scopus 로고    scopus 로고
    • 2, Relaxation Times Measurement
    • DOI 10.1002/mrm.10661
    • Deoni SC, Peters TM, Rutt BK (2004) Determination of optimal angles for variable nutation proton magnetic spin-lattice, T1, and spin-spin, T2, relaxation times measurement. Magn Reson Med 51: 194-199. (Pubitemid 38095718)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.1 , pp. 194-199
    • Deoni, S.C.L.1    Peters, T.M.2    Rutt, B.K.3
  • 38
    • 0002931369 scopus 로고
    • Mapping of the radiofrequency field
    • Insko EK, Bolinger L (1993) Mapping of the radiofrequency field. J Magn Reson A 103: 82-85.
    • (1993) J Magn Reson a , vol.103 , pp. 82-85
    • Insko, E.K.1    Bolinger, L.2
  • 39
    • 70349281577 scopus 로고    scopus 로고
    • Delayed gadolinium-enhanced MR imaging of articular cartilage: Three-dimensional T1 mapping with variable flip angles and B1 correction
    • Andreisek G, White LM, Yang Y, Robinson E, Cheng HL, et al. (2009) Delayed gadolinium-enhanced MR imaging of articular cartilage: three-dimensional T1 mapping with variable flip angles and B1 correction. Radiology 252: 865-873.
    • (2009) Radiology , vol.252 , pp. 865-873
    • Andreisek, G.1    White, L.M.2    Yang, Y.3    Robinson, E.4    Cheng, H.L.5
  • 40
    • 33644813235 scopus 로고    scopus 로고
    • Rapid high-resolution T(1) mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity
    • Cheng HL, Wright GA (2006) Rapid high-resolution T(1) mapping by variable flip angles: accurate and precise measurements in the presence of radiofrequency field inhomogeneity. Magn Reson Med 55: 566-574.
    • (2006) Magn Reson Med , vol.55 , pp. 566-574
    • Cheng, H.L.1    Wright, G.A.2
  • 41
    • 0031714439 scopus 로고    scopus 로고
    • 1 in the presence of RF- field inhomogeneities and flip-angle miscalibration
    • DOI 10.1002/mrm.1910400412
    • Venkatesan R, Lin W, Haacke EM (1998) Accurate determination of spindensity and T1 in the presence of RF-field inhomogeneities and flip-angle miscalibration. Magn Reson Med 40: 592-602. (Pubitemid 28440027)
    • (1998) Magnetic Resonance in Medicine , vol.40 , Issue.4 , pp. 592-602
    • Venkatesan, R.1    Lin, W.2    Haacke, E.M.3
  • 42
    • 0031416189 scopus 로고    scopus 로고
    • Adiabatic pulses
    • DOI 10.1002/(SICI)1099-1492(199712)10:8<423::AID-N
    • Tannus A, Garwood M (1997) Adiabatic pulses. NMR Biomed 10: 423-434. (Pubitemid 28110737)
    • (1997) NMR in Biomedicine , vol.10 , Issue.8 , pp. 423-434
    • Tannus, A.1    Garwood, M.2
  • 45
    • 33744544773 scopus 로고    scopus 로고
    • Parallel imaging in cardiovascular MRI: Methods and applications
    • DOI 10.1002/nbm.1051
    • Niendorf T, Sodickson DK (2006) Parallel imaging in cardiovascular MRI: methods and applications. NMR Biomed 19: 325-341. (Pubitemid 43811106)
    • (2006) NMR in Biomedicine , vol.19 , Issue.3 , pp. 325-341
    • Niendorf, T.1    Sodickson, D.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.