1
-
-
0028265272
-
The laryngeal mask airway in pediatric patients: Factors affecting ease of use during insertion and emergence
-
O'Neill B, Templeton JJ, Caramico L, Schreiner MS,. The laryngeal mask airway in pediatric patients: factors affecting ease of use during insertion and emergence. Anesthesia and Analgesia 1994; 78: 659-62.
-
(1994)
Anesthesia and Analgesia
, vol.78
, pp. 659-662
-
-
O'Neill, B.1
Templeton, J.J.2
Caramico, L.3
Schreiner, M.S.4
-
2
-
-
67649616881
-
Comparison of different techniques of laryngeal mask placement in children
-
Ghai B, Wig J,. Comparison of different techniques of laryngeal mask placement in children. Current Opinion in Anesthesiology 2009; 22: 400-4.
-
(2009)
Current Opinion in Anesthesiology
, vol.22
, pp. 400-404
-
-
Ghai, B.1
Wig, J.2
-
3
-
-
49849091610
-
Randomized trial of endotracheal tube versus laryngeal mask airway in simulated prehospital pediatric arrest
-
Chen L, Hsiao AL,. Randomized trial of endotracheal tube versus laryngeal mask airway in simulated prehospital pediatric arrest. Pediatrics 2008; 122: e294-7.
-
(2008)
Pediatrics
, vol.122
-
-
Chen, L.1
Hsiao, A.L.2
-
5
-
-
0035000358
-
The laryngeal mask airway in infants and children
-
Park C, Bahk JH, Ahn WS, Do SH, Lee KH,. The laryngeal mask airway in infants and children. Canadian Journal of Anesthesia 2001; 48: 413-7.
-
(2001)
Canadian Journal of Anesthesia
, vol.48
, pp. 413-417
-
-
Park, C.1
Bahk, J.H.2
Ahn, W.S.3
Do, S.H.4
Lee, K.H.5
-
8
-
-
0030478568
-
Jaw thrusting as a clinical test to assess the adequate depth of anaesthesia for insertion of the laryngeal mask
-
Drage MP, Nunez J, Vaughan RS, Asai T,. Jaw thrusting as a clinical test to assess the adequate depth of anaesthesia for insertion of the laryngeal mask. Anaesthesia 1996; 51: 1167-70.
-
(1996)
Anaesthesia
, vol.51
, pp. 1167-1170
-
-
Drage, M.P.1
Nunez, J.2
Vaughan, R.S.3
Asai, T.4
-
9
-
-
84873660011
-
Comparison of 2 cuff inflation methods before insertion of laryngeal mask airway for safe use without cuff manometer in children
-
Kim MS, Bai SJ, Oh JT, Youm SM, Lee JR,. Comparison of 2 cuff inflation methods before insertion of laryngeal mask airway for safe use without cuff manometer in children. American Journal of Emergency Medicine 2013; 31: 346-52.
-
(2013)
American Journal of Emergency Medicine
, vol.31
, pp. 346-352
-
-
Kim, M.S.1
Bai, S.J.2
Oh, J.T.3
Youm, S.M.4
Lee, J.R.5
-
10
-
-
77949291302
-
Reduced air leakage by adjusting the cuff pressure in pediatric laryngeal mask airways during spontaneous ventilation
-
Hockings L, Heaney M, Chambers NA, Erb TO, von Ungern-Sternberg BS,. Reduced air leakage by adjusting the cuff pressure in pediatric laryngeal mask airways during spontaneous ventilation. Pediatric Anesthesia 2010; 20: 313-7.
-
(2010)
Pediatric Anesthesia
, vol.20
, pp. 313-317
-
-
Hockings, L.1
Heaney, M.2
Chambers, N.A.3
Erb, T.O.4
Von Ungern-Sternberg, B.S.5
-
11
-
-
60349089722
-
The i-gel, a single-use supraglottic airway device with a non-inflatable cuff and an esophageal vent: An observational study in children
-
Beylacq L, Bordes M, Semjen F, Cros AM,. The i-gel, a single-use supraglottic airway device with a non-inflatable cuff and an esophageal vent: an observational study in children. Acta Anaesthesiologica Scandinavica 2009; 53: 376-9.
-
(2009)
Acta Anaesthesiologica Scandinavica
, vol.53
, pp. 376-379
-
-
Beylacq, L.1
Bordes, M.2
Semjen, F.3
Cros, A.M.4
-
12
-
-
68049139570
-
Prospective, randomized comparison of ProSeal and Classic laryngeal mask airways in anaesthetized neonates and infants
-
Micaglio M, Bonato R, De Nardin M, et al. Prospective, randomized comparison of ProSeal and Classic laryngeal mask airways in anaesthetized neonates and infants. British Journal of Anaesthesia 2009; 103: 263-7.
-
(2009)
British Journal of Anaesthesia
, vol.103
, pp. 263-267
-
-
Micaglio, M.1
Bonato, R.2
De Nardin, M.3
-
14
-
-
84882452716
-
A comparison of three supraglottic airway devices used by healthcare professionals during paediatric resuscitation simulation
-
Schunk D, Ritzka M, Graf B, Trabold B,. A comparison of three supraglottic airway devices used by healthcare professionals during paediatric resuscitation simulation. Emergency Medicine Journal 2013; 30: 754-7.
-
(2013)
Emergency Medicine Journal
, vol.30
, pp. 754-757
-
-
Schunk, D.1
Ritzka, M.2
Graf, B.3
Trabold, B.4
-
15
-
-
84863720692
-
A clinical evaluation of the i-gel supraglottic airway device in children
-
Hughes C, Place K, Berg S, Mason D,. A clinical evaluation of the i-gel supraglottic airway device in children. Pediatric Anesthesia 2012; 22: 765-71.
-
(2012)
Pediatric Anesthesia
, vol.22
, pp. 765-771
-
-
Hughes, C.1
Place, K.2
Berg, S.3
Mason, D.4
-
16
-
-
78549276233
-
Comparison of the LMA Supreme vs the i-gel in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation
-
Teoh WH, Lee KM, Suhitharan T, Yahaya Z, Teo MM, Sia AT,. Comparison of the LMA Supreme vs the i-gel in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation. Anaesthesia 2010; 65: 1173-9.
-
(2010)
Anaesthesia
, vol.65
, pp. 1173-1179
-
-
Teoh, W.H.1
Lee, K.M.2
Suhitharan, T.3
Yahaya, Z.4
Teo, M.M.5
Sia, A.T.6
-
17
-
-
51349105384
-
Lower cuff pressures improve the seal of pediatric laryngeal mask airways
-
Licina A, Chambers NA, Hullett B, Erb TO, von Ungern-Sternberg BS,. Lower cuff pressures improve the seal of pediatric laryngeal mask airways. Pediatric Anesthesia 2008; 18: 952-6.
-
(2008)
Pediatric Anesthesia
, vol.18
, pp. 952-956
-
-
Licina, A.1
Chambers, N.A.2
Hullett, B.3
Erb, T.O.4
Von Ungern-Sternberg, B.S.5
-
18
-
-
0036096923
-
Higher airway seal does not imply adequate positioning of laryngeal mask airways in paediatric patients
-
Inagawa G, Okuda K, Miwa T, Hiroki K,. Higher airway seal does not imply adequate positioning of laryngeal mask airways in paediatric patients. Pediatric Anesthesia 2002; 12: 322-6.
-
(2002)
Pediatric Anesthesia
, vol.12
, pp. 322-326
-
-
Inagawa, G.1
Okuda, K.2
Miwa, T.3
Hiroki, K.4
|